CodeSystem-DCM

Sourcefhir.dicom#2023.3.20230704:null (v4.0.1)
resourceTypeCodeSystem
idDCM
canonicalhttp://dicom.nema.org/resources/ontology/DCM
version2023.3.20230704
statusactive
publisherFHIR Project on behalf of DICOM
nameDICOMTerminologyDefinitions
titleDICOM Controlled Terminology Definitions
date2023-07-17T14:13:00+10:00
experimentalfalse
descriptionDICOM Code Definitions (Coding Scheme Designator "DCM" Coding Scheme Version 2023.3.20230704
copyrightThese codes are excerpted from Digital Imaging and Communications in Medicine (DICOM) Standard, Part 16: Content Mapping Resource, Copyright © 2011 by the National Electrical Manufacturers Association.
caseSensitivetrue
valueSethttp://dicom.nema.org/resources/ValueSet/all
contentcomplete
Usages

This case-sensitive code system http://dicom.nema.org/resources/ontology/DCM defines the following codes:

Code Display Definition
ANN Annotation A device, process or method that produces annotations.
AR Autorefraction An acquisition device, process or method that measures autorefraction.
ARCHIVE Archive A device, process or method that stores images and other objects for a prolonged period of time.
AS Angioscopy An acquisition device, process or method that records images during angioscopy.
ASMT Content Assessment Result A device, process or method that produces assessments of the content of other instances, e.g., for quality or suitability.
AU Audio An acquisition device, process or method that records audio.
BDUS Ultrasound Bone Densitometry An acquisition device, process or method that performs ultrasound bone densitometry.
BI Biomagnetic imaging An acquisition device, process or method that performs biomagnetic imaging.
BMD Bone Mineral Densitometry An acquisition device, process or method that performs bone mineral densitometry by X-Ray, including dual-energy X-Ray absorptiometry (DXA) and morphometric X-Ray absorptiometry (MXA).
CAD Computer Assisted Detection/Diagnosis An image processing device, process or method that performs computer assisted detection or diagnosis.
CAPTURE Image Capture An acquisition device, process or method that performs image capture, includes video capture.
CD Color flow Doppler An acquisition device, process or method that performs color flow Doppler.
CF Cinefluorography An acquisition device, process or method that performs cinefluorography.
COMP Computation Server A device, process or method that performs computation as a service; includes radiotherapy planning.
CP Culposcopy An acquisition device, process or method that records images during culposcopy.
CR Computed Radiography An acquisition device, process or method that performs computed radiography.
CS Cystoscopy An acquisition device, process or method that records images during cystoscopy.
CT Computed Tomography An acquisition device, process or method that performs computed tomography.
CTPROTOCOL CT Protocol A device, process or method that produces CT device acquisition protocols.
DD Duplex Doppler An acquisition device, process or method that performs duplex Doppler.
DF Digital fluoroscopy An acquisition device, process or method that performs digital fluoroscopy.
DG Diaphanography An acquisition device, process or method that performs diaphanography.
DM Digital microscopy An acquisition device, process or method that performs digital microscopy.
DMS Dermoscopy An acquisition device, process or method that performs imaging of the surface of the skin using epiluminescence microscopy.
DOC Document A device, process or method that produces documents. i.e., representations of documents as images, whether by scanning or other means.
DOCD Document Digitizer Equipment A device, process or method that digitizes hardcopy documents and imports them.
DS Digital Subtraction Angiography An acquisition device, process or method that performs digital subtraction angiography.
DSS Department System Scheduler A department-based information system (for instance, Radiology or Laboratory) that provides functions related to the management of orders received from external systems or through the department system’s user interface. This definition matches that of the DSS/OF Actor in the IHE Scheduled Workflow (SWF) Profile.
DX Digital Radiography An acquisition device, process or method that performs digital radiography.
EC Echocardiography An acquisition device, process or method that performs echocardiography.
ECG Electrocardiography An acquisition device, process or method that performs electrocardiography.
EEG Electroencephalography An acquisition device, process or method that performs electroencephalography.
EMG Electromyography An acquisition device, process or method that performs electromyography.
EOG Electrooculography An acquisition device, process or method that performs electrooculography.
EPS Cardiac Electrophysiology An acquisition device, process or method that performs cardiac electrophysiology.
ES Endoscopy An acquisition device, process or method that records images during endoscopy.
F Female Female sex.
FA Fluorescein angiography An acquisition device, process or method that performs fluorescein angiography.
FC Female changed to Male Female sex changed to Male sex.
FID Spatial Fiducials A device, process or method that identifies features or landmarks used to establish spatial correlation between objects or frames of reference.
FILMD Film Digitizer A device, process or method that performs film digitization.
FP Female Pseudohermaphrodite Female Pseudohermaphrodite.
FS Fundoscopy An acquisition device, process or method that records images during fundoscopy.
GM General Microscopy An acquisition device, process or method that performs general microscopy.
H Hermaphrodite Hermaphrodite.
HC Hard Copy A device, process or method that creates images to be printed as hard copy.
HD Hemodynamic Waveform An acquisition device, process or method that records hemodynamic waveforms.
IO Intra-oral Radiography An acquisition device, process or method that performs intra-oral radiography.
IOL Intraocular Lens Calculation A device, process or method that encodes calculations for an intraocular lens.
IVOCT Intravascular Optical Coherence Tomography An acquisition device, process or method that performs intravascular optical coherence tomography
IVUS Intravascular Ultrasound An acquisition device, process or method that performs intravascular ultrasound.
KER Keratometry An acquisition device, process or method that performs keratometry.
KO Key Object Selection A device, process or method that creates Key Object Selection objects.
LEN Lensometry An acquisition device, process or method that performs lensometry.
LOG Procedure Logging A device, process or method that performs procedure Logging; includes cath lab logging.
LP Laparoscopy An acquisition device, process or method that records images during laparoscopy.
LS Laser surface scan An acquisition device, process or method that performs laser surface scanning.
M Male Male sex.
M3D 3D Manufacturing Modeling System A device, process or method that produces data (models) for use in 3D manufacturing.
MA Magnetic resonance angiography An acquisition device, process or method that performs magnetic resonance angiography.
MC Male changed to Female Male sex changed to Female sex.
MCD Media Creation Device A device, process or method that creates DICOM interchange media.
MEDIM Portable Media Importer Equipment A device, process or method that retrieves and imports objects from Interchange Media.
MG Mammography An acquisition device, process or method that performs mammography.
MP Male Pseudohermaphrodite Male Pseudohermaphrodite.
MR Magnetic Resonance An acquisition device, process or method that performs magnetic resonance imaging.
MS Magnetic resonance spectroscopy An acquisition device, process or method that performs magnetic resonance spectroscopy.
NEARLINE Nearline Instances need to be retrieved from relatively slow media such as optical disk or tape.
NM Nuclear Medicine An acquisition device, process or method that performs nuclear medicine imaging.
OAM Ophthalmic Axial Measurements An acquisition device, process or method that measures the axial length of the eye.
OCT Optical Coherence Tomography An acquisition device, process or method that uses an interferometric, non-invasive optical tomographic technique to image 2D slices and 3D volumes of tissue using visible and near visible frequencies.
OFFLINE Offline Instances need to be retrieved by manual intervention.
ONLINE Online Instances are immediately available.
OP Ophthalmic photography An acquisition device, process or method that performs ophthalmic photography.
OPM Ophthalmic Mapping An acquisition device, process or method that measures corneal topography, corneal or retinal thickness, and other similar parameters that are typically displayed as maps.
OPR Ophthalmic Refraction An acquisition device, process or method that measures the refractive characteristics of the eye.
OPT Ophthalmic Tomography An acquisition device, process or method that performs tomography of the eye that is based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded.
OPTBSV Ophthalmic Tomography B-scan Volume Analysis An acquisition device, process or method that performs B-scan volume analysis of tomography images of the eye based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded.
OPTENF Ophthalmic Tomography En Face An acquisition device, process or method that creates en face tomography images of the eye based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded.
OPV Ophthalmic Visual Field An acquisition device, process or method that measures visual fields and perform visual perimetry.
OSS Optical Surface Scanner An acquisition device, process or method that performs optical surface scanning.
OT Other Modality Other Modality device.
PA Photoacoustic An acquisition device, process or method that performs imaging by means of tissue excitation through the absorption of short light pulses and detection of the resultant acoustic emission.
PLAN Plan A device, process or method that produces treatment plans, e.g., delivery instructions for RT.
POS Position Sensor A device or sensor measuring the orientation of the patient’s body.
PR Presentation State A device, process or method that creates Presentation State objects.
PRINT Hard Copy Print Server Hard Copy Print Server; includes printers with embedded DICOM print server.
PT Positron emission tomography An acquisition device, process or method that performs positron emission tomography (PET).
PX Panoramic X-Ray An acquisition device, process or method that performs panoramic X-Rays.
REG Registration An image processing device, process or method that creates Registration objects.
RESP Respiratory Waveform A device, process or method that produces waveforms of electrical signals from the patient’s respiratory system.
RF Radiofluoroscopy An acquisition device, process or method that performs radiofluoroscopy.
RG Radiographic imaging An acquisition device, process or method that performs radiographic imaging (conventional film/screen).
RT Radiation Therapy Device A device, process or method that delivers radiation therapy; includes linear accelerator, proton therapy.
RTDOSE Radiotherapy Dose A device, process or method that records radiotherapy dose.
RTIMAGE Radiotherapy Image An acquisition device, process or method that performs radiotherapy imaging; includes portal imaging.
RTPLAN Radiotherapy Plan A device, process or method that produces radiotherapy plans.
RTRECORD Radiotherapy Treatment Record A device, process or method that records radiotherapy treatment records.
RTSTRUCT Radiotherapy Structure Set A device, process or method that produces Radiotherapy Structure Sets.
RWV Real World Value Map A device, process or method that produces mappings between image pixel values and some real-world values.
SEG Segmentation An image processing device, process or method that performs segmentation.
SM Slide Microscopy An acquisition device, process or method that performs slide microscopy.
SMR Stereometric Relationship A device, process or method that records relationships between stereometric image pairs.
SR Structured Report Document A device, process or method that creates Structured Report documents.
SRF Subjective Refraction An acquisition device, process or method that records subjective refraction.
ST Single-photon emission computed tomography An acquisition device, process or method that performs single-photon emission computed tomography (SPECT).
STAIN Automated Slide Stainer A device, process or method that applies, in an automated manner, a stain, or reagent, to microscopy slides in preparation for imaging.
TEXTUREMAP Texture Map A device, process or method that produces texture maps.
TG Thermography An acquisition device, process or method that performs thermography.
U Unknown Sex Unknown Sex.
UNAVAILABLE Unavailable Instances cannot be retrieved.
US Ultrasound An acquisition device, process or method that performs ultrasound.
VA Visual Acuity An acquisition device, process or method that measures visual acuity.
VF Videofluorography An acquisition device, process or method that measures videofluorography.
VIDD Video Tape Digitizer Equipment A device, process or method that digitizes video tape and imports it.
WSD Workstation A networked computer equipped with a display and software for performing specific types of work, generally intended to be operated by a single user.
XA X-Ray Angiography An acquisition device, process or method that performs X-Ray angiography.
XC External-camera Photography An acquisition device, process or method that performs photography with an external camera.
109001 Digital timecode (NOS) A signal transmitted for the purpose of interchange of the current time, not specific to any source or methodology.
109002 ECG-based gating signal, processed A signal that is generated for each detection of a heart beat.
109003 IRIG-B timecode A signal transmitted by the Inter-Range Instrumentation Group for the purpose of synchronizing time clocks.
109004 X-Ray Fluoroscopy On Signal A signal that indicates that X-Ray source has been activated for fluoroscopy use.
109005 X-Ray On Trigger A signal that indicated that the X-Ray source has been activated for image recording.
109006 Differential signal An electrical signal derived from two electrodes.
109007 His bundle electrogram An electrophysiological recording from the HIS nerve bundle.
109008 Monopole signal An electrical signal from one electrode relative to an indifferent potential.
109009 Pacing (electrical) stimulus, voltage The voltage stimulus during cardiac pacing.
109010 Radio frequency ablation, power The power injected during RF ablation procedure.
109011 Voltage measurement by basket catheter Electrophysiological signals acquired using a multi-splined catheter each equipped with multiple electrodes.
109012 Voltage measurement by mapping catheter Electrophysiological signals acquired using a steerable catheter.
109013 Voltage measurement A voltage measurement not otherwise specified.
109014 35% of thermal CO A signal point that is 35% of the peak thermal cardiac output signal.
109015 70% of thermal CO A signal point that is 70% of the peak thermal cardiac output signal.
109016 A wave peak pressure The peak pressure of each heart beat in the atrium caused by the atrial contraction.
109017 A wave pressure, average The average of several A wave pressure measurements.
109018 Beat detected (accepted) An identified cardiac beat used in the determination of a measurement.
109019 Beat detected (rejected) An identified cardiac beat not used in the determination of a measurement.
109020 Diastolic pressure, average The average of several diastolic pressure measurements
109021 Diastolic pressure nadir The lowest pressure value excluding any undershoot artifact.
109022 End diastole The moment at the end of the diastolic phase of the cardiac cycle.
109023 End of expiration The moment at the end of respiratory expiration.
109024 End of inspiration The moment at the end of respiratory inspiration.
109025 Max dp/dt The maximum positive rate of change of pressure.
109026 Max neg dp/dt The maximum negative rate of change of pressure.
109027 Mean blood pressure The average blood pressure value, generally over 2 or more seconds
109028 Peak of thermal cardiac output bolus The peak change in blood temperature during a thermal cardiac output measurement.
109029 Start of expiration The moment respiratory expiration begins.
109030 Start of inspiration The moment of respiratory inspiration begins.
109031 Start of thermal cardiac output bolus The first discernible blood temperature change following the injectate during a thermal cardiac output measurement.
109032 Systolic pressure, average The average of several systolic blood pressure measurements.
109033 Systolic peak pressure The highest systolic blood pressure value excluding any overshoot artifact
109034 V wave peak pressure The peak pressure of each heart beat in the atrium caused by the filling of the atrium.
109035 V wave pressure, average The average of several V wave pressure measurements.
109036 Valve close The moment at which a heart valve closes.
109037 Valve open The moment at which a heart valve opens.
109038 Ablation off The moment when RF ablation current is turned off.
109039 Ablation on The moment when RF ablation current is turned on.
109040 HIS bundle wave The moment in the cardiac cycle when the HIS bundle nerves depolarize.
109041 P wave The surface electrocardiogram of the atrial contraction.
109042 Q wave The first negative deflection of the electrocardiogram cause by ventricular depolarization.
109043 R wave The first positive deflection the electrocardiogram cause by ventricular depolarization.
109044 S wave The first negative deflection after the R wave.
109045 Start of atrial contraction The beginning of the atrial contraction.
109046 Start of atrial contraction (subsequent) The beginning of the second atrial contraction of two consecutive beats.
109047 Stimulation at rate 1 interval The stimulation interval during cardiac stimulation first used in a pacing train.
109048 Stimulation at rate 2 interval The stimulation interval different from the first stimulation interval used in a pacing train.
109049 Stimulation at rate 3 interval A stimulation interval different from and subsequent to the second interval in a pacing train.
109050 Stimulation at rate 4 interval Describes a stimulation interval different from and subsequent to the third interval in a pacing train.
109051 T wave The electrocardiogram deflection caused by ventricular repolarization.
109052 V wave The peak pressure of each heart beat monitored in the atrium caused by the filling of the atrium.
109053 V wave of next beat The second V wave measurement of two consecutive beats.
109054 Patient State A description of the physiological condition of the patient.
109055 Protocol Stage The exercise level during a progressive cardiac stress test.
109056 Stress Protocol A series of physiological challenges designed to progressively increase the work of the heart.
109057 Catheterization Procedure Phase A subpart of a cardiac catheterization procedure
109058 Contrast Phase The subpart of a cardiac catheterization procedure in which a radio-opaque contrast medium is injected into the patient.
109059 Physiological challenges Physical changes administered to a patient in order to elicit an physiological response.
109060 Procedure Step Number Enumeration of a subpart of a catheterization procedure.
109061 EP Procedure Phase A subpart of en electrophysiological procedure.
109063 Pulse train definition A means of defining a series of cardiac stimulation pulses.
109070 End of systole
109071 Indicator mean transit time Time for a median particle to travel from point of injection to point of detection.
109072 Tau The time constant of isovolumic pressure fall.
109073 V max myocardial Maximum velocity of myocardial contractility.
109080 Real time acquisition Total time for the acquisition is shorter than cardiac cycle, no gating is applied.
109081 Prospective gating Certain thresholds have been set for a gating window that defines the acceptance of measurement data during the acquisition.
109082 Retrospective gating Certain thresholds have been set for a gating window that defines the acceptance of measurement data after the acquisition.
109083 Paced There is a constant RR interval, which makes thresholding not required; see Cardiac Synchronization Technique (0018,9037).
109091 Cardiac Stress State Imaging after injection of tracer during increased cardiac workload or increased myocardial blood flow, achieved by either exercise or pharmacologic means.
109092 Reinjection State Imaging after injection of additional tracer under resting conditions.
109093 Redistribution State Imaging after allowing a moderate amount of time for tracer to move from its initial sites of uptake.Example: For Thallium imaging this would correspond to imaging 2-6 hours after injection.
109094 Delayed Redistribution State Imaging after allowing an extended amount of time for tracer to move from its initial sites of uptake.Example: For Thallium imaging this would correspond to imaging more than 6 hours after injection.
109095 Peak stress state Peak Cardiac stress state
109096 Recovery state Recovery from cardiac stress
109101 Acquisition Equipment Equipment that originally acquired the data stored within composite instances.
109102 Processing Equipment Equipment that has processed composite instances to create new composite instances.
109103 Modifying Equipment Equipment that has modified existing composite instances (without creating new composite instances).
109104 De-identifying Equipment Equipment that has modified an existing composite instance to remove patient identifying information.
109105 Frame Extracting Equipment Equipment that has processed composite instances to create new composite instances by extracting selected frames from the original instance.
109106 Enhanced Multi-frame Conversion Equipment Equipment that has processed composite instances to create new composite instances by converting classic single frame images to enhanced multi-frame image, or vice versa and updating other instances to maintain referential integrity.
109110 Voice The sound of a human's speech, recorded during a procedure.
109111 Operator's narrative The voice of a device operator, recorded during a procedure.
109112 Ambient room environment The ambient sound recorded during a procedure, which may or may not include voice and other types of sound.
109113 Doppler audio The Doppler waveform recorded as an audible signal.
109114 Phonocardiogram The sound of the human heart beating.
109115 Physiological audio signal Any sound made by the human body.
109116 Arterial Pulse Waveform A digitized signal from the patient arterial system collected through pulse oximetry or other means.
109117 Respiration Waveform A digitized signal from the patient respiratory system representing respiration.
109120 On admission to unit The occasion on which a procedure was performed on admission to a specialist unit.
109121 On discharge The occasion on which a procedure was performed on discharge from hospital as an in-patient.
109122 On discharge from unit The occasion on which a procedure was performed on discharge from a specialist unit.
109123 Pre-intervention The occasion on which a procedure was performed immediately prior to non-surgical intervention. E.g, percutaneous angioplasty, biopsy.
109124 Post-intervention The occasion on which a procedure was performed immediately after to non-surgical intervention. E.g, percutaneous angioplasty, biopsy.
109125 At last appointment The occasion on which a procedure was performed at the most recent outpatient visit.
109132 Joint position method The active or passive joint positioning during acquisition.
109133 Physical force A physical force applied during acquisition.
109134 Prior to voiding Prior to voiding urine from the bladder.
109135 Post voiding Post voiding urine from the bladder.
109136 Neutral musculoskeletal position Neutral musculoskeletal position.
109137 During voiding During voiding urine from the bladder.
109200 America Kennel Club America Kennel Club.
109201 America's Pet Registry Inc. America's Pet Registry Inc.
109202 American Canine Association American Canine Association.
109203 American Purebred Registry American Purebred Registry.
109204 American Rare Breed Association American Rare Breed Association.
109205 Animal Registry Unlimited Animal Registry Unlimited.
109206 Animal Research Foundation Animal Research Foundation.
109207 Canadian Border Collie Association Canadian Border Collie Association.
109208 Canadian Kennel Club Canadian Kennel Club.
109209 Canadian Livestock Records Association Canadian Livestock Records Association.
109210 Canine Federation of Canada Canine Federation of Canada.
109211 Continental Kennel Club Continental Kennel Club.
109212 Dog Registry of America Dog Registry of America.
109213 Federation of International Canines Federation of International Canines.
109214 International Progressive Dog Breeders' Alliance International Progressive Dog Breeders' Alliance.
109215 National Kennel Club National Kennel Club.
109216 North American Purebred Dog Registry North American Purebred Dog Registry.
109217 United All Breed Registry United All Breed Registry.
109218 United Kennel Club United Kennel Club.
109219 Universal Kennel Club International Universal Kennel Club International.
109220 Working Canine Association of Canada Working Canine Association of Canada.
109221 World Kennel Club World Kennel Club.
109222 World Wide Kennel Club World Wide Kennel Club.
109701 Overall image quality evaluation Evaluation of overall image quality as described in section 7.3.2 of .
109702 Grayscale resolution evaluation Visual verification of sufficient grayscale resolution based on 8 and 10-bit markers as described in section 7.3.3 of .
109703 Luminance response evaluation Visual evaluation of luminance response using the TG18-CT test pattern as described in section 7.3.4 of .
109704 Luminance uniformity evaluation Visual detection of luminance non-uniformities as described in section 7.3.5 of .
109705 Chromaticity evaluation Visual verification of color uniformity as described in section 7.3.6 of .
109706 Pixel faults evaluation Visual detection of defective pixels on dark (TG18-UN80) and bright (TG18-UN10) images as described in section 7.3.7 of .
109707 Veiling glare evaluation Visual evaluation of veiling glare by looking at low contrast objects on 2 test patterns as described in section 7.3.8 of .
109708 Geometrical image evaluation Visual evaluation of geometry, phase/clock correction and clipping as described in section 7.3.9 of .
109709 Angular viewing evaluation Visual evaluation of viewing angle as described in section 7.3.10 of .
109710 Clinical evaluation Visual evaluation of the appearance of clinical images as described in section 7.3.11 of .
109801 TG18-QC Pattern AAPM TG18-QC Pattern used for evaluation of resolution, luminance, distortion, artifacts.See .
109802 TG18-BR Pattern AAPM TG18-BR Pattern used for the evaluation of the display of low-contrast, fine-detail image structuresSee .
109803 TG18-PQC Pattern AAPM TG18-PQC Pattern used for evaluation of resolution, luminance, contrast transfer for prints.See .
109804 TG18-CT Pattern AAPM TG18-CT Pattern used for evaluation of luminance response.See .
109805 TG18-LN8-01 Pattern The 1st image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109806 TG18-LN8-02 Pattern The 2nd image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109807 TG18-LN8-03 Pattern The 3rd image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109808 TG18-LN8-04 Pattern The 4th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109809 TG18-LN8-05 Pattern The 5th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109810 TG18-LN8-06 Pattern The 6th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109811 TG18-LN8-07 Pattern The 7th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109812 TG18-LN8-08 Pattern The 8th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109813 TG18-LN8-09 Pattern The 9th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109814 TG18-LN8-10 Pattern The 10th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration series.See .
109815 TG18-LN8-11 Pattern The 11th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109816 TG18-LN8-12 Pattern The 12th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109817 TG18-LN8-13 Pattern The 13th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109818 TG18-LN8-14 Pattern The 14th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109819 TG18-LN8-15 Pattern The 15th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109820 TG18-LN8-16 Pattern The 16th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109821 TG18-LN8-17 Pattern The 17th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See .
109822 TG18-LN8-18 Pattern The 18th image in the AAPM TG18-LN8- set used for DICOM grayscale calibration.See .
109823 TG18-LN12-01 Pattern The 1st image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109824 TG18-LN12-02 Pattern The 2 nd image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109825 TG18-LN12-03 Pattern The 3rd image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109826 TG18-LN12-04 Pattern The 4th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109827 TG18-LN12-05 Pattern The 5th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109828 TG18-LN12-06 Pattern The 6th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109829 TG18-LN12-07 Pattern The 7th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109830 TG18-LN12-08 Pattern The 8th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109831 TG18-LN12-09 Pattern The 9th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109832 TG18-LN12-10 Pattern The 10th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109833 TG18-LN12-11 Pattern The 11th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109834 TG18-LN12-12 Pattern The 12th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109835 TG18-LN12-13 Pattern The 13th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109836 TG18-LN12-14 Pattern The 14th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109837 TG18-LN12-15 Pattern The 15th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109838 TG18-LN12-16 Pattern The 16th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109839 TG18-LN12-17 Pattern The 17th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109840 TG18-LN12-18 Pattern The 18th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See .
109841 TG18-UN10 Pattern The AAPM TG18-UN10 Pattern used for evaluation of luminance and color uniformity, and angular response.See .
109842 TG18-UN80 Pattern The AAPM TG18-UN80 Pattern used for evaluation of luminance and color uniformity, and angular response.See .
109843 TG18-UNL10 Pattern The AAPM TG18-UNL10 Pattern is the AAPM TG-18 UN10 Pattern with added defining lines.See .
109844 TG18-UNL80 Pattern The AAPM TG18-UNL80 Pattern is the AAPM TG-18 UN80 Pattern with added defining lines.See .
109845 TG18-AD Pattern The AAPM TG18-AD Pattern used for visual evaluation of the reflection of ambient light from the display.See .
109846 TG18-MP Pattern The AAPM TG18-MP Pattern used for evaluation of Luminance response (bit-depth resolution).See .
109847 TG18-RH10 Pattern The AAPM TG18-RH10 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 10% luminance level.See .
109848 TG18-RH50 Pattern The AAPM TG18-RH50 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 50% luminance level.See .
109849 TG18-RH89 Pattern The AAPM TG18-RH89 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 89% luminance level.See .
109850 TG18-RV10 Pattern The AAPM TG18-RV10 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 10% luminance level.See .
109851 TG18-RV50 Pattern The AAPM TG18-RV50 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 50% luminance level.See .
109852 TG18-RV89 Pattern The AAPM TG18-RV89 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 89% luminance level.See .
109853 TG18-PX Pattern The AAPM TG18-PX Pattern used for the assessment of display resolution.See .
109854 TG18-CX Pattern The AAPM TG18-CX Pattern used to assess display resolution and resolution uniformity.See .
109855 TG18-LPH10 Pattern The AAPM TG18-LPH10 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 10% background level of the maximum pixel value.See .
109856 TG18-LPH50 Pattern The AAPM TG18-LPH50 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 50% positive contrast against 10% background level of the maximum pixel value.See .
109857 TG18-LPH89 Pattern The AAPM TG18-LPH89 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 89% background level of the maximum pixel value.See .
109858 TG18-LPV10 Pattern The AAPM TG18-LPV10 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 10% background level of the maximum pixel value.See .
109859 TG18-LPV50 Pattern The AAPM TG18-LPV50 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 50% background level of the maximum pixel value.See .
109860 TG18-LPV89 Pattern The AAPM TG18-LPV89 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 89% background level of the maximum pixel value.See .
109861 TG18-AFC Pattern The AAPM TG18-AFC Pattern used to assess display noise.See
109862 TG18-NS10 Pattern The AAPM TG18-NS10 Pattern is AAPM TG18-RV10/RH10 with only difference being the absence of the single line at the center of the measurement area.See .
109863 TG18-NS50 Pattern The AAPM TG18-NS50 Pattern is AAPM TG18-RV50/RH50 with only difference being the absence of the single line at the center of the measurement area.See .
109864 TG18-NS89 Pattern The AAPM TG18-NS89 Pattern is AAPM TG18-RV89/RH89 with only difference being the absence of the single line at the center of the measurement area.See .
109865 TG18-GV Pattern The TG18-GV Pattern used to assess display veiling.See .
109866 TG18-GVN Pattern The TG18-GVN Pattern used to assess display veiling. This pattern is identical to AAPM TG18-GV Pattern except that the large-diameter white circle is replaced with a black circle, creating a completely black pattern except for the presence of low-contrast targets.See .
109867 TG18-GQ Pattern The TG18-GQ Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GV except that is lacks the central low-contrast objects.See .
109868 TG18-GQN Pattern TG18-GQN Pattern used for the quantitative assessment of veiling glare. This pattern is identical to AAPM TG18-GQ Pattern except that the large-diameter white circle is replaced with a black circle, creating a completely black pattern except for the presence of low-contrast targets.See .
109869 TG18-GQB Pattern The TG18-GQB Pattern used for the quantitative assessment of veiling glare. This pattern is identical to AAPM TG18-GQ Pattern except eliminating the central black circle.See .
109870 TG18-GA03 Pattern The TG18-GA03 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 3.See .
109871 TG18-GA05 Pattern The TG18-GA05 Pattern This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 5.See .
109872 TG18-GA08 Pattern The TG18-GA08 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 8.See .
109873 TG18-GA10 Pattern The TG18-GA10 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 10.See .
109874 TG18-GA15 Pattern The TG18-GA15 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 15.
109875 TG18-GA20 Pattern The TG18-GA20 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 20.See .
109876 TG18-GA25 Pattern The TG18-GA25 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 25.See .
109877 TG18-GA30 Pattern The TG18-GA30 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 30.See .
109878 TG18-CH Image The AAPM TG18-CH Image is a reference anatomical PA chest image.See .
109879 TG18-KN Image The AAPM TG18-KN Image is a reference anatomical knee image.See .
109880 TG18-MM1 Image The AAPM TG18-MM1 Image is a reference anatomical mammogram image.See .
109881 TG18-MM2 Image The AAPM TG18-MM2 Image is a reference anatomical mammogram image.See .
109901 OIQ Pattern The IEC OIQ Pattern is used as an alternative to the TG18-QC Pattern.See .
109902 ANG Pattern The IEC ANG Pattern used for angular viewing evaluation.See .
109903 GD Pattern The IEC GD Pattern used for geometrical image evaluation.See .
109904 BN01 Pattern The IEC BN01 Pattern is used as an alternative to the TG18-LN-01 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109905 BN02 Pattern The IEC BN02 Pattern is used as an alternative to the TG18-LN-02 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109906 BN03 Pattern The IEC BN03 Pattern is used as an alternative to the TG18-LN-03 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109907 BN04 Pattern The IEC BN04 Pattern is used as an alternative to the TG18-LN-04 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109908 BN05 Pattern The IEC BN05 Pattern is used as an alternative to the TG18-LN-05 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109909 BN06 Pattern The IEC BN06 Pattern is used as an alternative to the TG18-LN-06 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109910 BN07 Pattern The IEC BN07 Pattern is used as an alternative to the TG18-LN-07 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109911 BN08 Pattern The IEC BN08 Pattern is used as an alternative to the TG18-LN-08 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109912 BN09 Pattern The IEC BN09 Pattern is used as an alternative to the TG18-LN-09 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109913 BN10 Pattern The IEC BN10 Pattern is used as an alternative to the TG18-LN-10 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109914 BN11 Pattern The IEC BN11 Pattern is used as an alternative to the TG18-LN-11 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109915 BN12 Pattern The IEC BN12 Pattern is used as an alternative to the TG18-LN-12 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109916 BN13 Pattern The IEC BN13 Pattern is used as an alternative to the TG18-LN-13 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109917 BN14 Pattern The IEC BN14 Pattern is used as an alternative to the TG18-LN-14 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109918 BN15 Pattern The IEC BN15 Pattern is used as an alternative to the TG18-LN-15 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109919 BN16 Pattern The IEC BN16 Pattern is used as an alternative to the TG18-LN-16 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109920 BN17 Pattern The IEC BN17 Pattern is used as an alternative to the TG18-LN-17 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109921 BN18 Pattern The IEC BN18 Pattern is used as an alternative to the TG18-LN-18 Pattern, to avoid the use of a cone or baffle with LCDs.See .
109931 DIN Grayscale Pattern Test image "Bild 2" for the gray-scale reproduction of imaging devices.See .
109932 DIN Geometry Pattern Test image "Bild 3" for the geometrical imaging properties of imaging devices.See .
109933 DIN Resolution Pattern Test image "Bild 5" for displaying the spatial and contrast resolution as well as the line structure of imaging devices.See .
109941 White Pattern An alternative to AAPM TG18-UN80, specified at 100% of maximum pixel value.
109943 SMPTE Pattern A standard display test pattern.See .A pattern is available at .
109991 CRT Display A Display Device that displays images on a Cathode Ray Tube.
109992 Liquid Crystal Display A Display Device that displays images on a Liquid Crystal Display.
109993 Plasma Display A Display Device that displays images on a Plasma Display.
109994 OLED A Display Device that displays images on an Organic Light Emitting Diode based display.
109995 DLP Rear Projection System A Display Device that projects images on a surface from behind using a Digital Light Processing Projector.
109996 DLP Front Projection System A Display Device that projects images on a surface from in front using a Digital Light Processing Projector.
109997 CRT Rear Projection System A Display Device that projects images on a surface from behind using a Cathode Ray Tube.
109998 CRT Front Projection System A Display Device that projects images on a surface from in front using a Cathode Ray Tube.
109999 Other Projection System A Display Device that projects images on a surface from an unspecified direction using an unspecified means.
110001 Image Processing Image processing work item.
110002 Quality Control Quality control work item.
110003 Computer Aided Diagnosis Computer aided diagnosis work item.
110004 Computer Aided Detection Computer aided detection work item.
110005 Interpretation The work item task is to prepare a report that contains the interpretation of an imaging study.
110006 Transcription Transcription work item.
110007 Report Verification Report verification work item.
110008 Print Print work item.
110009 No subsequent Workitems There will be no more work items scheduled.
110010 Film Film type of output.
110011 Dictation Dictation type of output.
110012 Transcription Transcription type of output.
110013 Media Import The procedure to read DICOM instances from DICOM interchange media, coerce identifying Attributes into the local namespace if necessary, and make the instances available.
110020 Sheet Film Digitized Digitization of Sheet Film.
110021 Cine Film Digitized Digitization of Cine Film.
110022 Video Tape Digitized Digitization of Video Tape.
110023 Paper Digitized Digitization of pages of a paper document (Units may be specified as Pages, Documents).
110024 CD Imported Importation of CD.
110025 DVD Imported Importation of DVD.
110026 MOD Imported Importation of MOD.
110027 Studies Imported Importation of DICOM Studies.
110028 Instances Imported Importation of DICOM Composite Instances.
110030 USB Disk Emulation A device that connects using the USB hard drive interface. These may be USB-Sticks, portable hard drives, and other technologies.
110031 Email Email and email attachments used as a media for data transport.
110032 CD CD-R, CD-ROM, and CD-RW media used for data transport.
110033 DVD DVD, DVD-RAM, and other DVD formatted media used for data transport.
110034 Compact Flash Media that comply with the Compact Flash standard.
110035 Multi-media Card Media that comply with the Multi-media Card standard.
110036 Secure Digital Card Media that comply with the Secure Digital Card standard.
110037 URI URI Identifier for network or other resource, see RFC3968.
110038 Paper Document Any paper or similar document.
110100 Application Activity Audit event: Application Activity has taken place.
110101 Audit Log Used Audit event: Audit Log has been used.
110102 Begin Transferring DICOM Instances Audit event: Storage of DICOM Instances has begun.
110103 DICOM Instances Accessed Audit event: DICOM Instances have been created, read, updated, or deleted -audit event.
110104 DICOM Instances Transferred Audit event: Storage of DICOM Instances has been completed.
110105 DICOM Study Deleted Audit event: Entire Study has been deleted.
110106 Export Audit event: Data has been exported out of the system.
110107 Import Audit event: Data has been imported into the system.
110108 Network Entry Audit event: System has joined or left network.
110109 Order Record Audit event: Order has been created, read, updated or deleted.
110110 Patient Record Audit event: Patient Record has been created, read, updated, or deleted.
110111 Procedure Record Audit event: Procedure Record has been created, read, updated, or deleted.
110112 Query Audit event: Query has been made.
110113 Security Alert Audit event: Security Alert has been raised.
110114 User Authentication Audit event: User Authentication has been attempted.
110119 Station AE Title Application Entity Title of a device.
110120 Application Start Audit event: Application Entity has started.
110121 Application Stop Audit event: Application Entity has stopped.
110122 Login Audit event: User login has been attempted.
110123 Logout Audit event: User logout has been attempted.
110124 Attach Audit event: Node has been attached.
110125 Detach Audit event: Node has been detached.
110126 Node Authentication Audit event: Node Authentication has been attempted.
110127 Emergency Override Started Audit event: Emergency Override has started.
110128 Network Configuration Audit event: Network configuration has been changed.
110129 Security Configuration Audit event: Security configuration has been changed.
110130 Hardware Configuration Audit event: Hardware configuration has been changed.
110131 Software Configuration Audit event: Software configuration has been changed.
110132 Use of Restricted Function Audit event: A use of a restricted function has been attempted.
110133 Audit Recording Stopped Audit event: Audit recording has been stopped.
110134 Audit Recording Started Audit event: Audit recording has been started.
110135 Object Security Attributes Changed Audit event: Security attributes of an object have been changed.
110136 Security Roles Changed Audit event: Security roles have been changed.
110137 User security Attributes Changed Audit event: Security attributes of a user have been changed.
110138 Emergency Override Stopped Audit event: Emergency Override has Stopped.
110139 Remote Service Operation Started Audit event: Remote Service Operation has Begun.
110140 Remote Service Operation Stopped Audit event: Remote Service Operation has Stopped.
110141 Local Service Operation Started Audit event: Local Service Operation has Begun.
110142 Local Service Operation Stopped Audit event: Local Service Operation Stopped.
110143 Authentication Decision Audit event: An authentication decision has been made.
110144 Authorization Decision Audit event: An authorization decision has been made.
110145 Session start Audit event: A persistent session has started.
110146 Session stop Audit event: A persistent session has stopped.
110147 Access Control Decision Audit event: An access control decision has been made.
110150 Application Audit participant role ID of software application.
110151 Application Launcher Audit participant role ID of software application launcher, i.e., the entity that started or stopped an application.
110152 Destination Role ID Audit participant role ID of the receiver of data.
110153 Source Role ID Audit participant role ID of the sender of data.
110154 Destination Media Audit participant role ID of media receiving data during an export.
110155 Source Media Audit participant role ID of media providing data during an import.
110180 Study Instance UID ParticipantObjectID type: Study Instance UID.
110181 SOP Class UID ParticipantObjectID type: SOP Class UID.
110182 Node ID ID of a node that is a participant object of an audit message.
110190 Issuer of Identifier System, organization, agency, or department that has assigned an instance identifier (such as placer or filler number, patient or provider identifier, etc.).
110500 Doctor canceled procedure Procedure order canceled by requesting physician or other authorized physician.
110501 Equipment failure Equipment failure prevented completion of procedure.
110502 Incorrect procedure ordered Procedure discontinued due to incorrect procedure being ordered.
110503 Patient allergic to media/contrast Procedure discontinued due to patient allergy to media/contrast (reported or reaction).
110504 Patient died Procedure discontinued due to death of Patient.
110505 Patient refused to continue procedure Procedure discontinued due to patient refusal to continue procedure.
110506 Patient taken for treatment or surgery Procedure discontinued due to patient being taken for treatment or surgery.
110507 Patient did not arrive Patient did not arrive for procedure.
110508 Patient pregnant Procedure discontinued due to patient pregnancy (reported or determined).
110509 Change of procedure for correct charging Procedure discontinued to restart with new procedure code for correct charging.
110510 Duplicate order Procedure discontinued due to duplicate orders received for same procedure.
110511 Nursing unit cancel Procedure order canceled by nursing unit.
110512 Incorrect side ordered Procedure discontinued due to incorrect side (laterality) being ordered.
110513 Discontinued for unspecified reason Procedure discontinued for unspecified reason.
110514 Incorrect worklist entry selected Procedure discontinued due to incorrect patient or procedure step selected from modality worklist.
110515 Patient condition prevented continuing Patient condition prevented continuation of procedure.
110516 Equipment change Procedure step is discontinued to change to other equipment or modality.
110518 Patient Movement A movement of the patient preventing continuation of procedure or affecting result quality.
110519 Operator Error An error of the operator preventing continuation of procedure or affecting result quality.
110521 Objects incorrectly formatted One or more of the objects is malformed.
110522 Object Types not supported Receiving System is unable to accept the object type.
110523 Object Set incomplete One or more objects associated with the object set is missing.
110524 Media Failure The contents of the Media could not be accessed properly.
110526 Resource pre-empted Procedure discontinued due to necessary equipment, staff or other resource becoming (temporarily) unavailable to the procedure.
110527 Resource inadequate Procedure discontinued due to necessary equipment, staff or other resource being inadequate to complete the procedure.
110528 Discontinued Procedure Step rescheduled A new Procedure Step has been scheduled to replace the Discontinued Procedure Step.
110529 Discontinued Procedure Step rescheduling recommended It is recommended that a new Procedure Step be scheduled to replace the Discontinued Procedure Step.
110530 Workitem assignment rejected by assigned resource The resource to which a workitem has been assigned has rejected the assignment.
110531 Insufficient quality for interpretation Reporting not possible due to lack of quality of the images provided.
110532 Interpretation requires specialist expertise The nature of the clinical problem means that reporting of the study requires a subject matter expert.
110533 Workitem expired The expiration date/time of the workitem has been exceeded.
110700 Ventral Diencephalon Ventral structures of the diencephalon that cannot readily be distinguished on MR imaging, including the hypothalamus, mammillary body, subthalamic nuclei, substantia nigra, red nucleus, lateral geniculate nucleus, medial geniculate nucleus, zona incerta, cerebral peduncle, lenticular fasciculus, medial lemniscus, and optic tract.See and .
110701 White Matter T1 Hypointensity Area(s) of reduced intensity on T1 weighted images relative to the surrounding white matter.These may be indicative of age-related or neurodegenerative white matter lesions, and may be co-located with areas of white matter T2 hyperintensity, but the concept is specifically confined to the MR appearance on T1 weighted images.
110702 White Matter T2 Hyperintensity Area(s) of increased intensity on T2 weighted images relative to the surrounding white matter.These may be indicative of age-related or neurodegenerative white matter lesions, and may be co-located with areas of white matter T1 hypointensity, but the concept is specifically confined to the MR appearance on T2 weighted images.
110703 superior longitudinal fasciculus I The dorsal component of the SLF originating from the medial and dorsal parietal cortex and ending in the dorsal and medial part of the frontal lobe.See Makris N, et al. "Segmentation of Subcomponents within the Superior Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral Cortex 15, no. 6 (June 1, 2005): 854-69. doi:10.1093/cercor/bhh186.
110704 superior longitudinal fasciculus II The major component of the SLF, derived from the caudal-inferior parietal region corresponding to the angular gyrus in the human and terminating within the dorsolateral frontal region.See Makris N, et al. "Segmentation of Subcomponents within the Superior Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral Cortex 15, no. 6 (June 1, 2005): 854-69. doi:10.1093/cercor/bhh186.
110705 superior longitudinal fasciculus III The ventral component of the SLF, originating from the supramarginal gyrus and terminating predominantly in the ventral premotor and prefrontal areas.See Makris N, et al. "Segmentation of Subcomponents within the Superior Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study." Cerebral Cortex 15, no. 6 (June 1, 2005): 854-69. doi:10.1093/cercor/bhh186.
110706 Perilesional White Matter White matter that surrounds a lesion of interest.
110800 Spin Tagging Perfusion MR Signal Intensity Signal intensity of a Spin tagging Perfusion MR image. Spin tagging is a technique for the measurement of blood perfusion, based on magnetically labeled arterial blood water as an endogenous tracer.
110801 Contrast Agent Angio MR Signal Intensity Signal intensity of a Contrast Agent Angio MR image.
110802 Time Of Flight Angio MR Signal Intensity Signal intensity of a Time-of-flight (TOF) MR image. Time-of-flight (TOF) is based on the phenomenon of flow-related enhancement of spins entering into an imaging slice. As a result of being unsaturated, these spins give more signal that surrounding stationary spins.
110803 Proton Density Weighted MR Signal Intensity Signal intensity of a Proton Density Weighted MR image. All MR images have intensity proportional to proton density. Images with very little T1 or T2 weighting are called 'PD-weighted'.
110804 T1 Weighted MR Signal Intensity Signal intensity of T1 Weighted MR image. A T1 Weighted MR image is created typically by using short TE and TR times.
110805 T2 Weighted MR Signal Intensity Signal intensity of a T2 Weighted MR image. T2 Weighted image contrast state is approached by imaging with a TR long compared to tissue T1 (to reduce T1 contribution to image contrast) and a TE between the longest and shortest tissue T2s of interest.
110806 T2* Weighted MR Signal Intensity Signal intensity of a T2* Weighted MR image. The T2* phenomenon results from molecular interactions (spin spin relaxation) and local magnetic field non-uniformities, which cause the protons to precess at slightly different frequencies.
110807 Field Map MR Signal Intensity Signal intensity of a Field Map MR image. A Field Map MR image provides a direct measure of the B0 inhomogeneity at each point in the image.
110808 Fractional Anisotropy Coefficient reflecting the fractional anisotropy of the tissues, derived from a diffusion weighted MR image. Fractional anisotropy is proportional to the square root of the variance of the Eigen values divided by the square root of the sum of the squares of the Eigen values.
110809 Relative Anisotropy Coefficient reflecting the relative anisotropy of the tissues, derived from a diffusion weighted MR image.
110810 Volumetric Diffusion Dxx Component Dxx Component of the diffusion tensor, quantifying the molecular mobility along the X axis.
110811 Volumetric Diffusion Dxy Component Dxy Component of the diffusion tensor, quantifying the correlation of molecular displacements in the X and Y directions.
110812 Volumetric Diffusion Dxz Component Dxz Component of the diffusion tensor, quantifying the correlation of molecular displacements in the X and Z directions.
110813 Volumetric Diffusion Dyy Component Dyy Component of the diffusion tensor, quantifying the molecular mobility along the Y axis.
110814 Volumetric Diffusion Dyz Component Dyz Component of the diffusion tensor, quantifying the correlation of molecular displacements in the Y and Z directions.
110815 Volumetric Diffusion Dzz Component Dzz Component of the diffusion tensor, quantifying the molecular mobility along the Z axis.
110816 T1 Weighted Dynamic Contrast Enhanced MR Signal Intensity Signal intensity of a T1 Weighted Dynamic Contrast Enhanced MR image. A T1 Weighted Dynamic Contrast Enhanced MR image reflects the dynamics of diffusion of the exogenous contrast media from the blood pool into the extra vascular extracellular space (EES) of the brain at a rate determined by the blood flow to the tissue, the permeability of the Brain Blood Barrier (BBB), and the surface area of the perfusing vessels.
110817 T2 Weighted Dynamic Contrast Enhanced MR Signal Intensity Signal intensity of a T2 Weighted Dynamic Contrast Enhanced MR image. A T2 Weighted Dynamic Contrast Enhanced MR image reflects the T2 of tissue decrease as the Gd contrast agent bolus passes through the brain.
110818 T2* Weighted Dynamic Contrast Enhanced MR Signal Intensity Signal intensity of a T2* Weighted Dynamic Contrast Enhanced MR image. A T2* Weighted Dynamic Contrast Enhanced MR image reflects the T2* of tissue decrease as the Gd contrast agent bolus passes through the brain.
110819 Blood Oxygenation Level Signal intensity of a Blood Oxygenation Level image. Used in Photoacoustic Imaging and functional MR. In functional MR BOLD imaging it is used for detecting brain activation and is sensitive to blood oxygenation (but also to cerebral blood flow and volume).
110820 Nuclear Medicine Projection Activity Accumulated decay event counts in a nuclear medicine projection image.
110821 Nuclear Medicine Tomographic Activity Accumulated decay event counts in a Nuclear Medicine Tomographic image (including PET).
110822 Spatial Displacement X Component Spatial Displacement along axis X of a non linear deformable spatial registration image. The X axis is defined in reference to the patient's orientation, and is increasing to the left hand side of the patient.
110823 Spatial Displacement Y Component Spatial Displacement along axis Y of a non linear deformable spatial registration image. The Y axis is defined in reference to the patient's orientation, and is increasing to the posterior side of the patient.
110824 Spatial Displacement Z Component Spatial Displacement along axis Z of a Non linear deformable spatial registration image. The Z axis is defined in reference to the patient's orientation, and is increasing toward the head of the patient.
110825 Hemodynamic Resistance Measured resistance to the flow of blood.
110826 Indexed Hemodynamic Resistance Measured resistance to the flow of blood.
110827 Tissue Velocity Velocity of tissue based on Doppler measurements.
110828 Flow Velocity Velocity of blood flow based on Doppler measurements.
110829 Flow Variance Statistical variance of blood velocity relative to mean.
110830 Elasticity Scalar value related to the elastic properties of the tissue.
110831 Perfusion Scalar value related to the volume of blood perfusing into tissue.
110832 Speed of sound Speed of sound in tissue.
110833 Ultrasound Attenuation Reduction in strength of ultrasound signal as the wave.
110834 RGB R Component Red component of a true color image (RGB).
110835 RGB G Component Green component of a true color image (RGB).
110836 RGB B Component Blue component of a true color image (RGB).
110837 YBR FULL Y Component Y (Luminance) component of a YBR FULL image, as defined in JPEG 2000.
110838 YBR FULL CB Component CB (Blue chrominance) component of a YBR FULL image, as defined in JPEG 2000.
110839 YBR FULL CR Component CR (Red chrominance) component of a YBR FULL image, as defined in JPEG 2000.
110840 YBR PARTIAL Y Component Y (Luminance) component of a YBR PARTIAL image, as defined in JPEG 2000.
110841 YBR PARTIAL CB Component CB (Blue chrominance) component of a YBR PARTIAL image, as defined in JPEG 2000.
110842 YBR PARTIAL CR Component CR (Red chrominance) component of a YBR PARTIAL image, as defined in JPEG 2000.
110843 YBR ICT Y Component Y (Luminance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000.
110844 YBR ICT CB Component CB (Blue chrominance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000.
110845 YBR ICT CR Component CR (Red chrominance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000.
110846 YBR RCT Y Component Y (Luminance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000.
110847 YBR RCT CB Component CB (Blue chrominance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000.
110848 YBR RCT CR Component CR (Red chrominance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000.
110849 Echogenicity The ability of a material to create an ultrasound return echo.
110850 X-Ray Attenuation Decrease in the number of photons in an X-Ray beam due to interactions with the atoms of a material substance. Attenuation is due primarily to two processes, absorption and scattering.
110851 X-Ray Attenuation Coefficient Coefficient that describes the fraction of a beam of X-Rays or gamma rays that is absorbed or scattered per unit thickness of the absorber. This value basically accounts for the number of atoms in a cubic cm volume of material and the probability of a photon being scattered or absorbed from the nucleus or an electron of one of these atoms.
110852 MR signal intensity Signal intensity of an MR image, not otherwise specified.
110853 Binary Segmentation Binary value denoting that the segmented property is present.
110854 Fractional Probabilistic Segmentation Probability, defined as a percentage, that the segmented property occupies the spatial area defined by the voxel.
110855 Fractional Occupancy Segmentation Percentage of the voxel area occupied by the segmented property.
110856 Linear Displacement Spatial dimension, denoting a linear displacement.
110857 Photon Energy Dimension denoting the energy (frequency or wavelength) of photons.
110858 Time Dimension used to sequence events, to compare the duration of events and the intervals between events.
110859 Angle Spatial dimension, denoting an angle.
110860 Left-Right Axis A spatial dimension axis running along a line between the patient's left and right side.
110861 Head-Foot Axis A spatial dimension axis running along a line between the patient's head and foot.
110862 Anterior-Posterior Axis A spatial dimension axis running along a line between the patient's anterior and posterior sides.
110863 Apex-Base Axis A spatial dimension axis running along a line between the apex and base of an organ, object, or chamber.
110864 Anterior-Inferior Axis A spatial dimension axis running along a line between the anterior and inferior sides of an organ, object, or chamber.
110865 Septum-Wall Axis A spatial dimension axis running along a line between the septum and wall of a chamber.
110866 Right To Left Orientation of a spatial dimension where increasing values run from the right to the left side of the patient.
110867 Left To Right Orientation of a spatial dimension where increasing values run from the left to the right side of the patient.
110868 Head To Foot Orientation of a spatial dimension where increasing values run from the head to the foot of the patient.
110869 Foot To Head Orientation of a spatial dimension where increasing values run from the foot to the head of the patient.
110870 Anterior To Posterior Orientation of a spatial dimension where increasing values run from the anterior to the posterior side of the patient.
110871 Posterior To Anterior Orientation of a spatial dimension where increasing values run from the posterior to the anterior side of the patient.
110872 Apex To Base Orientation of a spatial dimension where increasing values run from the apex to the base.
110873 Base To Apex Orientation of a spatial dimension where increasing values run from the base to the apex.
110874 Anterior To Inferior Orientation of a spatial dimension where increasing values run from the anterior to the inferior.
110875 Inferior To Anterior Orientation of a spatial dimension where increasing values run from the inferior to the anterior.
110876 Septum To Wall Orientation of a spatial dimension where increasing values run from the septum of a chamber to the opposite wall.
110877 Wall To Septum Orientation of a spatial dimension where increasing values run from the opposite wall to the septum of a chamber.
110901 Image Position (Patient) X The x coordinate of the upper left hand corner (center of the first voxel transmitted) of the image, with respect to the patient-based coordinate system.
110902 Image Position (Patient) Y The y coordinate of the upper left hand corner (center of the first voxel transmitted) of the image, with respect to the patient-based coordinate system.
110903 Image Position (Patient) Z The z coordinate of the upper left hand corner (center of the first voxel transmitted) of the image, with respect to the patient-based coordinate system.
110904 Image Orientation (Patient) Row X The x value of the first row direction cosine with respect to the patient, with respect to the patient-based coordinate system.
110905 Image Orientation (Patient) Row Y The y value of the first row direction cosine with respect to the patient, with respect to the patient-based coordinate system.
110906 Image Orientation (Patient) Row Z The z value of the first row direction cosine with respect to the patient, with respect to the patient-based coordinate system.
110907 Image Orientation (Patient) Column X The x value of the first column direction cosine with respect to the patient, with respect to the patient-based coordinate system.
110908 Image Orientation (Patient) Column Y The y value of the first column direction cosine with respect to the patient, with respect to the patient-based coordinate system.
110909 Image Orientation (Patient) Column Z The z value of the first column direction cosine with respect to the patient, with respect to the patient-based coordinate system.
110910 Pixel Data Rows Number of rows in the pixel data of the image.
110911 Pixel Data Columns Number of columns in the pixel data of the image.
111000 Algorithm Family The family of algorithm(s) that best describes the software algorithm used.
111001 Algorithm Name The name assigned by a manufacturer to a specific software algorithm.
111002 Algorithm Parameters The input parameters used by a manufacturer to configure the behavior of a specific software algorithm.
111003 Algorithm Version The software version identifier assigned by a manufacturer to a specific software algorithm.
111004 Analysis Performed The type of correlation applied to detection results.
111005 Assessment Category Assignment of intermediate or overall interpretation results to a general category.
111006 Breast composition Assessment of annotating tissues in breast; generally including fatty, mixed or dense
111007 Breast Outline including Pectoral Muscle Tissue Purpose of reference for an SCOORD Content Item that is an outline of the breast that includes the pectoral muscle tissue
111008 Calcification Distribution The type of distribution associated with detected calcifications.
111009 Calcification Type Identification of the morphology of detected calcifications.
111010 Center The central point of a finding or feature.
111011 Certainty of Feature The likelihood that the feature analyzed is in fact the type of feature identified.
111012 Certainty of Finding The likelihood that the finding detected is in fact the type of finding identified.
111013 Certainty of Impression The certainty that a device places on an impression, where 0 equals no certainty and 100 equals certainty.
111014 Clockface or region A location identifier based on clockface numbering or anatomic subregion.
111015 Composite Feature An item that is an inferred correlation relating two or more individual findings or features.
111016 Composite type The inferred relationship between the findings or features making up a composite feature.
111017 CAD Processing and Findings Summary General assessment of whether or not CAD processing was successful, and whether any findings resulted.
111018 Content Date The date the data creation started.
111019 Content Time The time the data creation started.
111020 Depth A location identifier based on a feature's inferred distance from the surface of the associated anatomy.
111021 Description of Change A textual description of the change that occurred over time in a qualitative characteristic of a feature.
111022 Detection Performed The type of finding sought after by a specific algorithm applied to one image.
111023 Differential Diagnosis/Impression A general change that occurred within an imaged area between a prior imaging procedure and the current imaging procedure.
111024 Failed Analyses A group of analysis algorithms that were attempted, but failed.
111025 Failed Detections A group of detection algorithms that were attempted, but failed.
111026 Horizontal Pixel Spacing For projection radiography, the horizontal physical distance measured at the front plane of an Image Receptor housing between the center of each pixel (spacing between the centers of adjacent columns). For tomographic images, the horizontal physical distance in the patient between the center of each pixel.
111027 Image Laterality Laterality of (possibly paired) body part contained in an image.
111028 Image Library A container that references all image data used as evidence to produce a report.
111029 Image Quality Rating A numeric value in the range 0 to 100, inclusive, where 0 is worst quality and 100 is best quality.
111030 Image Region Purpose of reference for an SCOORD Content Item that identifies a specific region of interest within an image
111031 Image View The projection of the anatomic region of interest on an image receptor.
111032 Image View Modifier Modifier for Image View.
111033 Impression Description Free-form text describing the overall or an individual impression.
111034 Individual Impression/​Recommendation A container for a group of related results from interpretation of one or more images and associated clinical information.
111035 Lesion Density The X-Ray attenuation of a lesion relative to the expected attenuation of an equal volume of fibroglandular breast tissue.
111036 Mammography CAD Report A structured report containing the results of computer-aided detection or diagnosis applied to breast imaging and associated clinical information.
111037 Margins The characteristic of the boundary, edges or border of a detected lesion.
111038 Number of calcifications The quantity of calcifications detected within an identified group or cluster.
111039 Object type A non-lesion object identified within one or more images.
111040 Original Source Purpose of reference for a COMPOSITE Content Item that identifies it as the original source of evidence for another Content Item in the report
111041 Outline The outline of a finding or feature.
111042 Pathology The inferred type of disease associated with an identified feature.
111043 Patient Orientation Column The patient orientation relative to the image plane, specified by a value that designates the anatomical direction of the positive column axis (top to bottom).
111044 Patient Orientation Row The patient orientation relative to the image plane, specified by a value that designates the anatomical direction of the positive row axis (left to right).
111045 Pectoral Muscle Outline Purpose of reference for an SCOORD Content Item that is an outline of the pectoral muscle tissue only
111046 Percent Fibroglandular Tissue Percent of breast area that is mammographically dense, excluding pectoralis muscle.
111047 Probability of cancer The likelihood that an identified finding or feature is cancerous.
111048 Quadrant location A location identifier based on the division of an area into four regions.
111049 Qualitative Difference A qualitative characteristic of a feature that has changed over time.
111050 Quality Assessment The effect of the quality of an image on its usability.
111051 Quality Control Standard The quality control standard used to make a quality assessment.
111052 Quality Finding A specific quality related deficiency detected within an image.
111053 Recommended Follow-up Recommended type of follow-up to an imaging procedure, based on interpreted results.
111054 Recommended Follow-up Date Recommended follow-up date to an imaging procedure, based on interpreted results.
111055 Recommended Follow-up Interval Recommended follow-up interval to an imaging procedure, based on interpreted results.
111056 Rendering Intent The recommendation of the producer of a Content Item regarding presentation of the Content Item by recipients of the report.
111057 Scope of Feature An indication of how widespread the detection of a feature is within the analyzed image data.
111058 Selected Region Description A textual description of the contents of a selected region identified within an image.
111059 Single Image Finding An item that was detected on one image.
111060 Study Date Date on which the acquisition of the study information was started.
111061 Study Time Time at which the acquisition of the study information was started.
111062 Successful Analyses A group of analysis algorithms that were attempted and completed successfully.
111063 Successful Detections A group of detection algorithms that were attempted and completed successfully.
111064 Summary of Detections An overall indication of whether the CAD detection algorithms applied were completed successfully.
111065 Summary of Analyses An overall indication of whether the CAD analysis algorithms applied were completed successfully.
111066 Vertical Pixel Spacing For projection radiography, the vertical physical distance measured at the front plane of an Image Receptor housing between the center of each pixel (spacing between the centers of adjacent rows). For tomographic images, the vertical physical distance in the patient between the center of each pixel.
111069 Crosstable A radiographic projection that has been with the patient lying on a table with the X-Ray source on one side of the table and the detector on the other.
111071 CAD Operating Point One of a number of discrete points on the Receiver-Operator Characteristics (ROC) curve that reflects the expected sensitivity and specificity of a CAD algorithm, where zero indicates the highest specificity, lowest sensitivity operating point. The value should not exceed the Maximum CAD Operating Point.
111072 Maximum CAD Operating Point The maximum value of CAD Operating Point for the specific CAD algorithm used.
111081 CAD Operating Point Description The intended interpretation of a CAD Operating Point.
111086 False Markers per Image The number of false CAD markers per image. Correlates to inverse of Image Specificity.
111087 False Markers per Case The number of false markers per collection of images that are CAD processed as a group. Correlates to inverse of Case Specificity.
111088 Case Sensitivity The percentage of cancers that should be detected by a CAD algorithm where CAD marks the cancers in at least one view.
111089 Lesion Sensitivity The percentage of cancers that should be detected by a CAD algorithm where CAD marks the cancers in each view.
111090 Case Specificity The percentage of cases (collections of images CAD processed as a group) without cancer that have no CAD findings whatsoever. Correlates to inverse of False Markers per Case.
111091 Image Specificity The percentage of images without cancer that have no CAD findings whatsoever. Correlates to inverse of False Markers per Image.
111092 Recommended CAD Operating Point The CAD operating point that is recommended for initial display by the creator of the structured report.
111093 CAD Operating Point Table A list of CAD operating points including their corresponding characteristics.
111099 Selected region A specific area of interest noted within an image.
111100 Breast geometry The surface shape of all or a portion of breast related anatomy.
111101 Image Quality Image quality incorporates the following clinical image evaluation parameters: assessment of positioning, compression, artifacts, exposure, contrast, sharpness, and labeling.
111102 Non-lesion A finding or feature that is identified as a non-anatomic foreign object.
111103 Density A space-occupying lesion identified in a single image or projection
111104 Individual Calcification A single identified calcification
111105 Calcification Cluster Multiple calcifications identified as occupying a small area of tissue (less than 2 cc)
111111 Cooper's ligament changes Straightening or thickening of Cooper's ligaments.
111112 Mass in the skin An abnormality noted at imaging within the dermis of the breast.
111113 Mass on the skin An abnormality noted at imaging on the epidermis of the breast.
111120 Post Procedure Mammograms for Marker Placement An assessment category to indicate that images have been acquired to assess marker placement following a breast interventional procedure.
111121 Follow-up post biopsy as directed by clinician An indication that the patient should seek post procedural follow-up directives from a clinical health care provider.
111122 Known biopsy proven malignancy - take appropriate action A recommendation on a patient with known cancer to take steps appropriate to the diagnosis.
111123 Marker placement Positioning of a radiopaque marker.
111124 Personal history of breast cancer with mastectomy Patient has previous diagnosis of breast cancer resulting in mastectomy.
111125 Known biopsy proven malignancy Patient has had biopsy containing proven malignancy.
111126 Image detected mass Patient has a finding of mass reported on a prior imaging study.
111127 Targeted A breast imaging procedure performed on a specific area of the breast.
111128 Survey A breast imaging procedure performed on the entire breast.
111129 Clustered microcysts A cluster of tiny anechoic foci each smaller than 2-3 mm in diameter with thin (less than 0.5 mm) intervening septations and no discrete solid components.
111130 Complicated cyst A fluid filled mass most commonly characterized by homogeneous low-level internal echoes on ultrasound.
111135 Additional projections Views not inclusive of MLO and CC (BI-RADS®).
111136 Spot magnification view(s) A spot or coned down compression of the breast providing a reduction in the thickness and a magnification of the localized area of interest and improved separation of breast tissue.
111137 Ultrasound
111138 Old films for comparison Obtain previous mammography studies to compare to present study.
111139 Ductography A medical procedure used for the sampling of mammary duct tissue
111140 Normal interval follow-up Follow up study at 12 months for women ≥ 40 years of age having a prior negative study and no mitigating risk factors for breast cancer.
111141 Any decision to biopsy should be based on clinical assessment Any decision to perform tissue acquisition should be based on clinical assessment.
111142 Follow-up at short interval (1-11 months) Follow-up at short interval (1-11 months).
111143 Biopsy should be considered Tissue acquisition should be considered.
111144 Needle localization and biopsy Breast tissue acquisition following the identification of an area of concern with the placement of a needle or needle-wire assembly.
111145 Histology using core biopsy Pathologic analysis of breast tissue and lesions using core tissue samples.
111146 Suggestive of malignancy - take appropriate action Lesions that do not have the characteristic morphologies of breast cancer but have a definite probability of being malignant. There is a sufficient concern to urge a biopsy.
111147 Cytologic analysis Cellular analysis of specimen.
111148 Biopsy should be strongly considered Tissue acquisition should be strongly considered.
111149 Highly suggestive of malignancy - take appropriate action Lesions have a high probability of being cancer, which require additional action.
111150 Presentation Required: Rendering device is expected to present The producer of a report intends for a recipient of the report to present or display the associated Content Item.
111151 Presentation Optional: Rendering device may present The producer of a report considers the presentation or display of the associated Content Item by a recipient to be optional.
111152 Not for Presentation: Rendering device expected not to present The producer of a report intends for a recipient of the report NOT to present or display the associated Content Item.
111153 Target content items are related temporally The associated Content Items are identified as being the same finding or feature at different points in time.
111154 Target content items are related spatially The associated Content Items are identified as being the same finding or feature on different projections taken at the same point in time.
111155 Target content items are related contra-laterally The associated Content Items are identified as being related side-to-side.
111156 Feature detected on the only image There is one image in the interpreted data.
111157 Feature detected on only one of the images There is more than one image of the same modality in the interpreted data.
111158 Feature detected on multiple images There is more than one image of the same modality in the interpreted data.
111159 Feature detected on images from multiple modalities The interpreted data contains images from multiple modalities.
111168 Scar tissue The fibrous tissue replacing normal tissues destroyed by disease or injury
111170 J Wire A medical appliance used for localization of non palpable breast lesions to insure that the proper area is removed in a surgical biopsy
111171 Pacemaker A medical appliance used for regulating cardiac rhythms
111172 Paddle A compression device used for obtaining mammographic images
111173 Collimator A device used for restricting an X-Ray beam
111174 ID Plate An area designated on a radiographic film for facility and patient ID information
111175 Other Marker Site specific markers.
111176 Unspecified The value of the concept is not specified
111177 View and Laterality Marker is missing Image quality deficiency according to MQSA.
111178 View and Laterality Marker does not have both view and laterality Image quality deficiency according to MQCM.
111179 View and Laterality Marker does not have approved codes Image quality deficiency according to MQCM.
111180 View and Laterality Marker is not near the axilla Image quality deficiency according to MQCM.
111181 View and Laterality Marker overlaps breast tissue Image quality deficiency according to MQCM.
111182 View and Laterality Marker is partially obscured Image quality deficiency according to MQCM.
111183 View and Laterality Marker is incorrect Image quality deficiency.
111184 View and Laterality Marker is off image Image quality deficiency.
111185 Flash is not near edge of film Image quality deficiency according to MQCM.
111186 Flash is illegible, does not fit, or is lopsided Image quality deficiency according to MQSA.
111187 Flash doesn't include patient name and additional patient id Image quality deficiency according to MQCM.
111188 Flash doesn't include date of examination Image quality deficiency according to MQCM.
111189 Flash doesn't include facility name and location Image quality deficiency according to MQSA.
111190 Flash doesn't include technologist identification Image quality deficiency according to MQCM.
111191 Flash doesn't include cassette/screen/detector identification Image quality deficiency according to MQCM.
111192 Flash doesn't include mammography unit identification Image quality deficiency according to MQCM.
111193 Date sticker is missing Image quality deficiency according to MQCM.
111194 Technical factors missing Image quality deficiency according to MQCM.
111195 Collimation too close to breast Image quality deficiency according to MQCM.
111196 Inadequate compression Image quality deficiency according to MQCM.
111197 MLO Insufficient pectoral muscle Image quality deficiency according to MQCM.
111198 MLO No fat is visualized posterior to fibroglandular tissues Image quality deficiency according to MQCM.
111199 MLO Poor separation of deep and superficial breast tissues Image quality deficiency according to MQCM.
111200 MLO Evidence of motion blur Image quality deficiency according to MQCM.
111201 MLO Inframammary fold is not open Image quality deficiency according to MQCM.
111202 CC Not all medial tissue visualized Image quality deficiency according to MQCM.
111203 CC Nipple not centered on image Image quality deficiency according to MQCM.
111204 CC Posterior nipple line does not measure within 1 cm of MLO Image quality deficiency according to MQCM.
111205 Nipple not in profile Image quality deficiency.
111206 Insufficient implant displacement incorrect Image quality deficiency according to MQCM.
111207 Image artifact(s) Signals that do not faithfully reproduce actual anatomic structures because of distortion or of addition or deletion of information.
111208 Grid artifact(s) Feature(s) arising from the acquisition unit's anti-scatter grid mechanism. For two-dimensional systems, such features include those of mechanically damaged or incorrectly positioned grids. For moving or Bucky grids, artifacts may result from intentional grid motion that is inadequate in duration or velocity uniformity.
111209 Positioning Inadequate arrangement of the anatomy of interest with respect to the X-Ray field and image detector sensitive area. Examples: 1) positioning is "cutoff" when the projection of anatomy of interest falls outside the sensitive area of the detector; 2) "cone cut", in which the X-Ray field does not adequately cover the anatomy of interest; 3) detector's sensitive surface is too small to cover the projection of the anatomy of interest; 4) improper angular orientation or "rotation" of anatomy of interest with respect to the X-Ray source, or detector; 5) projection of other anatomy or clothing over the anatomy of interest in the image.
111210 Motion blur Unacceptable image blur resulting from motion of the anatomy of interest during exposure or the inadequately compensated motion of X-Ray source with respect to the image detector during exposure.
111211 Under exposed Inadequate number of quanta reached the detector during exposure. Reasons for under exposed images include low kVp, low mAs product, excess Source Image Distance. Under exposed images have inadequate signal and higher noise in the areas of interest.
111212 Over exposed An excess number of quanta reached the detector during exposure. Reasons for over exposed images include high kVp, high mAs product, short Source Image Distance. Over exposed images have high signal and lower noise in the areas of interest. Over exposed area may demonstrate lack of contrast from over saturation of the detector.
111213 No image No evidence of a patient exposure.
111214 Detector artifact(s) Superposed features or flaws of the detector.
111215 Artifact(s) other than grid or detector artifact Features or discontinuities arising from causes other than the anti-scatter grid and image detector.
111216 Mechanical failure Failure of the device to operate according to mechanical design specifications.
111217 Electrical failure Failure of a device to operate according to electrical design specifications.
111218 Software failure Attributable to software used in generation or handling of image.
111219 Inappropriate image processing Images processed inappropriately, not following appropriate protocol.
111220 Other failure Failure that is not mechanical or electrical or otherwise described.
111221 Unknown failure Unidentified or unknown cause of failure.
111222 Succeeded The attempted process was completely successful.
111223 Partially Succeeded The attempted process succeeded in some ways, but failed in others.
111224 Failed The attempted process completely failed.
111225 Not Attempted No process was performed.
111233 Individual Impression/​Recommendation Analysis Analysis of a related group of findings or features detected during image data inspection, to produce a summary impression and/or recommendation.
111234 Overall Impression/​Recommendation Analysis Analysis of all groups of findings or features, to produce a single impression and/or recommendation.
111235 Unusable - Quality renders image unusable Quality of an image renders it unusable for the intended purpose.
111236 Usable - Does not meet the quality control standard Quality of an image is usable for the intended purpose, but does not meet the quality control standard.
111237 Usable - Meets the quality control standard Quality of an image is usable for the intended purpose and meets the quality control standard.
111238 Mammography Quality Control Manual 1999, ACR An image quality control standard specified by the American College of Radiology.
111239 Title 21 CFR Section 900, Subpart B An image quality control standard in the US Code of Federal Regulations.
111240 Institutionally defined quality control standard An image quality control standard specified or adopted by the institution responsible for the document.
111241 All algorithms succeeded; without findings No findings resulted upon successful completion of all attempted computer-aided detection and/or analysis.
111242 All algorithms succeeded; with findings One or more findings resulted upon successful completion of all attempted computer-aided detection and/or analysis.
111243 Not all algorithms succeeded; without findings No findings resulted from the attempted computer-aided detection and/or analysis, but one or more failures occurred in the process.
111244 Not all algorithms succeeded; with findings One or more findings resulted from the attempted computer-aided detection and/or analysis, but one or more failures occurred in the process.
111245 No algorithms succeeded; without findings All of the attempted computer-aided detection and/or analysis failed, so there could be no findings.
111248 Adenolipoma A benign tumor having glandular characteristics but composed of fat, with the presence of normal mammary ducts
111249 Ductal hyperplasia
111250 Adenomyoepithelioma Neoplasms composed of myoepithelial cells
111251 Normal axillary node Axillary node that is normal in appearance with no associated pathology.
111252 Axillary node with calcifications Axillary node containing calcifications.
111253 Axillary node hyperplasia Excessive proliferation of normal tissue arrangement of the axillary node.
111254 Asynchronous involution
111255 Benign cyst with blood Cyst with benign morphology containing blood.
111256 Benign Calcifications Calcifications having typically benign morphology. They are not of intermediate or high probability of concern for malignancy.
111257 Intracystic papilloma Growing within a cystic adenoma, filling the cavity with a mass of branching epithelial processes
111258 Ductal adenoma Adenoma located in mammary duct, present as discrete sclerotic nodules, solitary or multiple.
111259 Diabetic fibrous mastopathy The occurrence of fibrous tumor-forming stromal proliferation in patients with diabetes mellitus.
111260 Extra abdominal desmoid A deep seated firm tumor frequently occurring on the chest consisting of collagenous tissue that infiltrates surround muscle; frequently recurs but does not metastasize
111262 Epidermal inclusion cyst A cyst formed of a mass of epithelial cells, as a result of trauma has been pushed beneath the epidermis. The cyst is lined with squamous epithelium and contains concentric layers or keratin
111263 Fibroadenomatoid hyperplasia Excessive proliferation of fibroadenoma tissue.
111264 Fibroadenolipoma A lipoma with an abundant stroma of fibrous tissue.
111265 Foreign body (reaction)
111269 Galactocele Retention cyst caused by occlusion of a lactiferous duct
111271 Hemangioma - nonparenchymal, subcutaneous A congenital anomaly that leads to a proliferation of blood vessels leading to a mass that resembles a neoplasm, not located in parenchymal areas but subcutaneous
111273 Hyperplasia, usual
111277 Juvenile papillomatosis A form of fibrocystic disease in young woman with florid and sclerosing adenosis that microscopically may suggest carcinoma.
111278 Lactating adenoma Enlarging masses during lactation. A circumscribed benign tumor composed primarily of glandular structures with scanty stroma, with prominent secretory changes in the duct
111279 Lactational change Changes related to the process of lactation.
111281 Large duct papilloma A papilloma pertaining to large mammary duct.
111283 Myofibroblastoma Solitary or multiple tumors of muscles and fibrous tissues, or tumors composed of myofibroblasts
111284 Microglandular adenosis Irregular clusters of small tubules are present in adipose or fibrous tissue, resembling tubular carcinoma but lacking stromal fibroblastic proliferation.
111285 Multiple Intraductal Papillomas Papilloma typically involving an aggregate of adjacent ducts in the periphery of the breast, likely representing involvement of several foci of one or two duct systems.
111286 No abnormality No abnormality.
111287 Normal breast tissue Normal breast tissue.
111288 Neurofibromatosis Condition in which there are tumors of various sizes on peripheral nerves. They may be neuromas or fibromas
111290 Oil cyst (fat necrosis cyst) A cyst resulting from the loss of the epithelial lining of a sebaceous dermoid or lacteal cyst.
111291 Post reduction mammoplasty Breast tissue with characteristics of a benign nature, following breast reduction surgery.
111292 Pseudoangiomatous stromal hyperplasia A benign stromal lesion composed of intermixed stromal and epithelial elements. The lobular and duct structures of the breast parenchyma are separated by an increased amount of stroma, non specific proliferative epithelial changes include hyperplasia of duct and lobular epithelium often with accentuation of myoepithelial cells and aprocine metaplasia with or without cyst formation.
111293 Radial scar An nonencapsulated stellate lesion consisting of a fibroelastic core and radiating bands of fibrous connective tissue containing lobules manifesting adenosis and ducts with papillary or diffuse intraductal hyperplasia
111294 Sclerosing adenosis Prominent interductal fibrosis of the terminal ductules
111296 Silicone granuloma Nodular inflammatory lesions due to the presence of silicone in the breast tissue.
111297 Nipple Characteristic The morphologic status of the nipple.
111298 Virginal hyperplasia Spontaneous excessive proliferation of breast tissue, usually found in younger women.
111299 Peripheral duct papillomas Papilloma(s) pertaining the peripheral ducts.
111300 Axillary node with lymphoma Axillary node with lymphoid tissue neoplasm.
111301 Axillary nodal metastases Metastatic disease to the axillary node.
111302 Angiosarcoma A malignant neoplasm occurring most often in breast and skin, believed to originate from endothelial cells of blood vessels, microscopically composed of closely packed round or spindle shaped cells, some of which line small spaces resembling vascular clefts
111303 Blood vessel (vascular) invasion Histological changes to the vascular system related to an invasive process.
111304 Carcinoma in children Carcinoma of the breast found in patients less than 20 years of age.
111305 Carcinoma in ectopic breast A carcinoma found in supernumerary breasts and aberrant breast tissue.
111306 Carcinoma with endocrine differentiation A carcinoma that synthesizes substances, including hormones, not considered to be normal products of the breast.
111307 Basal cell carcinoma of nipple A basal cell carcinoma that arises in the nipple of the breast.
111308 Carcinoma with metaplasia
111309 Cartilaginous and osseous change Tissue changes to bones and cartilage.
111310 Carcinoma in pregnancy and lactation Carcinoma of the breast presenting during pregnancy or lactation.
111311 Carcinosarcoma A malignant neoplasm that contains elements of carcinoma and sarcoma, so extensively intermixed as to indicate neoplasia of epithelial and mesenchymal tissue
111312 Intraductal comedocarcinoma with necrosis Comedocarcinoma of a duct with areas of necrotic tissue.
111313 Intraductal carcinoma, low grade A non-invasive carcinoma restricted to the glandular lumen characterized by less aggressive malignant cytologic features and behavior.
111314 Intraductal carcinoma micro-papillary
111315 Intracystic papillary carcinoma A malignant neoplasm characterized by the formation of numerous, irregular, finger-like projections of fibrous stroma that is covered with a surface layer of neoplastic epithelial cells found in a cyst.
111316 Invasive and in-situ carcinoma Carcinoma with both characteristics of localized and spreading disease.
111317 Invasive lobular carcinoma
111318 Leukemic infiltration Mammary infiltrates as a secondary manifestation in patients with established leukemia.
111320 Lympathic vessel invasion Histological changes to the lymphatic system related to an invasive process.
111321 Lymphoma A heterogeneous group of neoplasms arising in the reticuloendoethelial and lymphatic systems
111322 Occult carcinoma presenting with axillary lymph node metastases A small carcinoma, either asymptomatic or giving rise to metastases without symptoms due to the primary carcinoma presenting with metastatic disease in the axillary lymph nodes.
111323 Metastatic cancer to the breast A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a non-mammary malignant neoplasm.
111324 Metastatic cancer to the breast from the colon A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a neoplasm in the colon.
111325 Metastatic cancer to the breast from the lung A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a neoplasm in the lung.
111326 Metastatic melanoma to the breast A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a melanoma.
111327 Metastatic cancer to the breast from the ovary A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a neoplasm in the ovary.
111328 Metastatic sarcoma to the breast A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a sarcoma.
111329 Multifocal intraductal carcinoma Multiple foci of non-invasive carcinoma restricted to the glandular lumen.
111330 Metastatic disease to axillary node A malignant lesion in an axillary node arising from a non-axillary neoplasm.
111331 Malignant fibrous histiocytoma
111332 Multifocal invasive ductal carcinoma Multiple sites of ductal carcinoma.
111333 Metastasis to an intramammary lymph node A malignant lesion in a intramammary lymph node arising from a non-intramammary lymph node neoplasm.
111334 Malignant melanoma of nipple A malignant melanoma of the skin that arises in the nipple of the breast.
111335 Neoplasm of the mammary skin
111336 Papillary carcinoma in-situ
111338 Recurrent malignancy Recurrent malignancy.
111340 Squamous cell carcinoma of the nipple Squamous cell carcinoma to the terminal portion of the alveolar.
111341 Intraductal carcinoma, high grade A non-invasive carcinoma restricted to the glandular lumen characterized by more aggressive malignant cytologic features and behavior.
111342 Invasive cribriform carcinoma
111343 Angular margins An indication that some or all of the margin of a lesion has sharp corners, often forming acute angles.
111344 Fine pleomorphic calcification Calcifications that vary in sizes and shapes and are usually smaller than0.5 mm in diameter.
111345 Macrocalcifications Coarse calcifications that are 0.5 mm or greater in size.
111346 Calcifications within a mass An indicator that calcifications are imbedded within a mass.
111347 Calcifications outside of a mass An indicator that calcifications are imaged outside of a mass finding.
111350 Breast background echotexture Tissue composition of the breast noted on sonography.
111351 Homogeneous fat echotexture Fat lobules and uniformly echogenic bands of supporting structures comprise the bulk of breast tissue.
111352 Homogeneous fibroglandular echotexture A uniformly echogenic layer of fibroglandular tissue is seen beneath a thin layer of subcutaneous fat.
111353 Heterogeneous echotexture The breast texture is characterized by multiple small areas of increased and decreased echogenicity.
111354 Orientation Referential relationship of the finding to the imaging device as noted on sonography.
111355 Parallel The long axis of a lesion parallels the skin line ("wider-than-tall" or in a horizontal orientation).
111356 Not parallel The anterior-posterior or vertical dimension is greater than the transverse or horizontal dimension.
111357 Lesion boundary The lesion boundary describes the transition zone between the mass and the surrounding tissue.
111358 Abrupt interface The sharp demarcation between the lesion and surrounding tissue can be imperceptible or a distinct well-defined echogenic rim of any thickness.
111359 Echogenic halo There is no sharp demarcation between the mass and the surrounding tissue, which is bridged by an echogenic transition zone.
111360 Echo pattern An imaging characteristic of resonance noted during sonography.
111361 Anechoic Without internal echoes.
111362 Hyperechoic Having increased echogenicity relative to fat or equal to fibroglandular tissue.
111363 Complex Mass contains both anechoic and echogenic components.
111364 Hypoechoic Defined relative to fat; masses are characterized by low-level echoes throughout.
111365 Isoechoic Having the same echogenicity as fat (a complicated cyst or fibroadenoma may be isoechoic or hypoechoic).
111366 Posterior acoustic features The attenuation characteristics of a mass with respect to its acoustic transmission.
111367 No posterior acoustic features No posterior shadowing or enhancement.
111368 Posterior enhancement Increased posterior echoes.
111369 Posterior shadowing Decreased posterior echoes; edge shadows are excluded.
111370 Combined posterior enhancement and shadowing More than one pattern of posterior attenuation, both shadowing and enhancement.
111371 Identifiable effect on surrounding tissues Sonographic appearance of adjacent structures relative to a mass finding.
111372 Vascularity Characterization of vascularization in region of interest.
111373 Vascularity not present Vascularity not evident, such as on ultrasound.
111374 Vascularity not assessed Vascularity not evaluated.
111375 Vascularity present in lesion Vascularity on imaging is seen within a lesion.
111376 Vascularity present immediately adjacent to lesion Vascularity on imaging is seen immediately adjacent to a lesion.
111377 Diffusely increased vascularity in surrounding tissue Vascularity on imaging is considered diffusely elevated within the surrounding breast tissue.
111380 Correlation to other Findings Relationship of the new anomaly to other clinical or imaging anomalies.
111381 Correlates to physical examination findings An indication that the current imaging finding relates to a finding from a clinical breast examination.
111382 Correlates to mammography findings An indication that the current imaging finding relates to a finding from a mammography study.
111383 Correlates to MRI findings An indication that the current imaging finding relates to a finding from a breast MRI study.
111384 Correlates to ultrasound findings An indication that the current imaging finding relates to a finding from a breast ultrasound study.
111385 Correlates to other imaging findings An indication that the current imaging finding relates to a finding from an imaging study.
111386 No correlation to other imaging findings An indication that the current imaging finding has no relation to findings from any other imaging study.
111387 No correlation to clinical findings An indication that the current imaging finding has no relation to any other clinical findings.
111388 Malignancy Type Classification of the cancer as invasive, DCIS, or other.
111389 Invasive breast carcinoma A malignancy that has spread beyond an area of focus.
111390 Other malignancy type A breast cancer with malignant pathology findings that are not classified as invasive or in situ.
111391 Menstrual Cycle Phase A specific timeframe during menses.
111392 1st week In the first week of the menstrual cycle phase, that is, one week following menses.
111393 2nd week In the second week of the menstrual cycle phase, that is, two weeks following menses.
111394 3rd week In the third week of the menstrual cycle phase, that is, three weeks following menses.
111395 Estimated Timeframe An estimated period of time.
111396 < 3 months ago An event occurred less than 3 months ago.
111397 4 months to 1 year ago An event occurred between 4 months and 1 year ago.
111398 > 1 year ago An event occurred longer than 1 year ago.
111399 Timeframe uncertain The timing of an event is not recalled.
111400 Breast Imaging Report Report title for the diagnostic report for one or more breast imaging or intervention procedures.
111401 Reason for Procedure Concept name for the description of why a procedure has been performed.
111402 Clinical Finding A finding during clinical examination (i.e., history and physical examination) such as pain, palpable mass or discharge.
111403 Baseline screening mammogram First screening mammogram taken for patient that is used as a comparison baseline for further examinations.
111404 First mammogram ever First mammogram taken for a patient without regard to whether it was for screening or a diagnostic procedure.
111405 Implant type Concept name for the material of which a breast prosthetic device is constructed.
111406 Number of similar findings A numeric count of findings classified as similar in nature.
111407 Implant finding Concept name for the status of a breast prosthetic device as noted by imaging.
111408 Film Screen Mammography Mammogram using traditional X-Ray film.
111409 Digital Mammography Mammogram using a digital image acquisition system.
111410 Surgical consult Referred for evaluation by a surgeon.
111411 Mammography CAD Computer aided detection and/or computer aided diagnosis for mammography.
111412 Narrative Summary Concept name for a text-based section of a report.
111413 Overall Assessment A title for a report section that summarizes all interpretation results for a report with one overriding assessment.
111414 Supplementary Data Concept name for a collection of supporting evidence for a report.
111415 Additional evaluation requested from prior study Prior study indicates that additional imaging be performed to further evaluate a suspicious or questionable anatomic region.
111416 Follow-up at short interval from prior study The prior study recommended a follow-up breast imaging study in 1 to 11 months (generally in 6 months).
111417 History of breast augmentation, asymptomatic Prior breast augmentation (breast enlargement) and is not presenting with any symptoms.
111418 Review of an outside study Review or second opinion made on an image performed outside of the facility.
111419 Additional evaluation requested from abnormal screening study Additional breast imaging performed at the time of the patient's screening mammogram.
111420 History of benign breast biopsy Patient has had previous benign breast biopsies.
111421 Personal history of breast cancer with breast conservation therapy Patient has had a prior surgery such as a lumpectomy or quadrantectomy to remove malignant breast tissue, but breast tissue remains.
111423 Physical Examination Results The results of a physical examination performed on the patient, possibly including the results of inspection, palpation, auscultation, or percussion.
111424 Comparison to previous studies The result of assessing the current imaging study in comparison to previous imaging studies.
111425 Intraluminal filling defect An abnormality observed during ductography where the ductal system within the breast fills in an abnormal pattern. Ductography is an imaging study in which a radio opaque contrast media is introduced into the ductal system of the breast through the nipple and images of the ductal system are obtained.
111426 Multiple filling defect During ductography an observation of more than one filling abnormality within the breast ductal system.
111427 Abrupt duct termination An abnormality observed during ductography where the ductal system within the breast terminates in an unusual fashion.
111428 Extravasation Abnormal flowage of contrast media within the breast noted on ductography.
111429 Duct narrowing An abnormality observed during ductography where the ductal system within the breast appears narrow.
111430 Cyst fill During ductography an observation of the contrast media filling a cyst within the breast.
111431 Instrument Approach The area and line within the anatomy through which a needle or instrument passes during an interventional procedure.
111432 Inferolateral to superomedial The line within the anatomy from the lower outer to the upper inner aspect.
111433 Inferomedial to superolateral The line within the anatomy from the lower inner to the upper outer aspect.
111434 Superolateral to inferomedial The line within the anatomy from the upper outer to the lower inner aspect.
111435 Superomedial to inferolateral The line within the anatomy from the upper inner to the lower outer aspect.
111436 Number of passes The number of times a biopsy instrument is passed through an area of interest.
111437 Number of specimens The number of biopsy specimens obtained from an interventional procedure.
111438 Needle in target An indicator of whether or not a biopsy or localizing needle in an interventional procedure is seen to be in the area of interest.
111439 Number of needles around target The number of localizing needles placed around the area of interest in an interventional procedure.
111440 Incision made An indicator of whether or not an incision was made in the anatomy during an interventional procedure.
111441 Microclip placed An indicator of whether or not a radio opaque microclip was placed in the anatomy during an interventional procedure.
111442 Confirmation of target An indicator of the degree of success of an interventional procedure.
111443 Target completely contained in the specimen An indicator that during an interventional procedure the area of interest was fully excised and is noted in the resultant biopsy specimen.
111444 Target partially obtained in the specimen An indicator that during an interventional procedure the area of interest was partially excised and is noted in the resultant biopsy specimen.
111445 Target not in the specimen An indicator that following an interventional procedure the area of interest is not seen in the resultant biopsy specimen.
111446 Calcifications seen in the core An indicator that following an interventional procedure the targeted calcifications are noted in the resultant biopsy specimen.
111447 Lesion completely removed An indicator that during an interventional procedure the area of interest was fully excised and is noted in the resultant biopsy specimen.
111448 Lesion partially removed An indicator that during an interventional procedure the area of interest was partially excised and is noted in the resultant biopsy specimen.
111449 Fluid obtained An indicator that during an interventional procedure fluid was successfully aspirated.
111450 Light brown color Color that is a light shade of brown.
111451 Dark red color Color that is a dark shade of red.
111452 Dark brown color Color that is a dark shade of brown.
111453 Bright red color Color that is a bright shade of red.
111454 Blood tinged color Color that is tinged with the color of blood.
111455 Occult blood test result An indicator of whether or not the fluid obtained during an interventional procedure contains red blood cells.
111456 Action on fluid An indicator of whether or not fluid during an interventional procedure was sent for cytological analysis or simply discarded.
111457 Sent for analysis An indicator that fluid obtained during an interventional procedure was sent to a laboratory for analysis.
111458 Discarded An indicator that fluid obtained during an interventional procedure was discarded.
111459 Mass with calcifications A radiopaque density noted during diagnostic imaging that has associated calcific densities.
111460 Complex cyst A fluid-filled sac with greater than normal characteristics.
111461 Intracystic lesion A tumor within a cyst.
111462 Solid mass A tumor or lesion.
111463 Supplementary Data for Intervention Supporting evidence for interpretation results of an interventional procedure.
111464 Procedure Modifier A descriptor that further qualifies or characterizes a type of procedure.
111465 Needle Gauge Needle size (diameter) characterization.
111466 Severity of Complication An indicator of the gravity of a problem experienced by a patient, related to a procedure that was performed.
111467 Needle Length Distance from the hub or bushing to the tip of the needle.
111468 Pathology Results The collection of observations and findings from pathologic analysis.
111469 Sampling DateTime The date and time that the sample was collected from the patient.
111470 Uninvolved Indicates that the margin of the biopsy specimen was not involved with the tumor.
111471 Involved Indicates that the margin of the biopsy specimen was involved with the tumor.
111472 Nipple involved Indicates whether the nipple was involved in an interventional procedure or pathologic analysis.
111473 Number of nodes removed Indicates the number of lymph nodes removed.
111474 Number of nodes positive Indicates the number of lymph nodes removed that contain cancer cells.
111475 Estrogen receptor The result of a test for the presence of a protein that binds with estrogen.
111476 Progesterone receptor The result of a test for the presence of a protein that binds with progesterone.
111477 S Phase Indicates the percentage of cells in S phase. Cell division is defined by phases; the S phase is the stage during which DNA replicates.
111478 Non-bloody discharge (from nipple) The visible emission of non-bloody fluid from the nipple.
111479 Difficult physical/clinical examination The inability to discern normal versus abnormal breast tissue during palpation.
111480 Cancer elsewhere An indication that a patient has or had a malignant occurrence in an area of the body other than the breast.
111481 Saline implant A salt water filled prosthetic device implanted in the breast.
111482 Polyurethane implant A polymer based (plastic) prosthetic device implanted in the breast.
111483 Percutaneous silicone injection The introduction of polymeric organic silicon based material through the skin, as for breast augmentation or reconstruction.
111484 Combination implant A prosthetic device that contains more than one material implanted in the breast.
111485 Pre-pectoral implant A breast implant placed in front of the pectoralis major muscle.
111486 Retro-pectoral implant A breast implant placed behind the pectoralis major muscle.
111487 Mammographic (crosshair) Using X-Ray technique and a superimposed set of crossed lines for detection or placement.
111488 Mammographic (grid) Using X-Ray technique and a superimposed aperture for detection or placement.
111489 Palpation guided Using physical touch for detection or placement.
111490 Vacuum assisted The performance of a biopsy procedure using a vacuum device attached to the biopsy needle.
111491 Abnormal discharge Unusual or unexpected emission of fluid.
111492 No complications Having experienced no adverse medical conditions related to or resulting from an interventional procedure.
111494 Stage 0 TNM grouping of tumor stage, from AJCC, where primary tumor is Tis, regional lymph node is N0, and distant metastasis is M0.
111495 Stage I TNM grouping of tumor stage, from AJCC, where primary tumor is T1, regional lymph node is N0, and distant metastasis is M0.
111496 Stage IIA TNM grouping of tumor stage, from AJCC, where primary tumor is T0 or T1, with regional lymph node N1 and distant metastasis is M0, or T2 with N0 and M0.
111497 Stage IIB TNM grouping of tumor stage, from AJCC, where primary tumor is T2, with regional lymph node N1 and distant metastasis is M0, or T3 with N0 and M0.
111498 Stage IIIA TNM grouping of tumor stage, from AJCC, where primary tumor is T0, T1 or T2, with regional lymph node N2 and distant metastasis is M0, or T3 with N1 or N2 and M0.
111499 Stage IIIB TNM grouping of tumor stage, from AJCC, where primary tumor is T4, regional lymph node is N0, N1 or N2, and distant metastasis is M0.
111500 Stage IIIC TNM grouping of tumor stage, from AJCC, where primary tumor is any T value, regional lymph node is N3, and distant metastasis is M0.
111501 Stage IV TNM grouping of tumor stage, from AJCC, where primary tumor is any T value, regional lymph node is any N value, and distant metastasis is M1.
111502 Bloom-Richardson Grade Histologic tumor grade (sometimes called Scarff-Bloom-Richardson grade) is based on the arrangement of the cells in relation to each other -- whether they form tubules, how closely they resemble normal breast cells (nuclear grade) and how many of the cancer cells are in the process of dividing (mitotic count).
111503 Normal implants Breast prosthetic devices are intact, not leaking, and are in a normal shape and form.
111504 Asymmetric implants Breast prosthetic devices are not symmetric, equal, corresponding in form, or are in one breast (unilateral).
111505 Calcified implant Fibrous or calcific contracture of the tissue capsule that forms around a breast prosthetic device.
111506 Distorted implant Breast prosthetic device is twisted out of normal shape or form.
111507 Silicone-laden lymph nodes Silicone from breast prosthetic device found in lymphatic tissue.
111508 Free silicone Silicone found in breast tissue outside of the prosthetic capsule or implant membrane.
111509 Herniated implant Protrusion of part of the structure normally encapsulating the content of the breast prosthetic device.
111510 Explantation Evidence of removal of a breast prosthetic device.
111511 Relevant Patient Information for Breast Imaging Historical patient health information of interest to the breast health clinician.
111512 Medication History Information regarding usage by the patient of certain medications, such as hormones.
111513 Relevant Previous Procedures Interventional or non-interventional procedures previously performed on the patient, such as breast biopsies.
111514 Relevant Indicated Problems Abnormal conditions experienced by the patient that serve as the reason for performing a procedure, such as a physical breast examination.
111515 Relevant Risk Factors Personal, familial, and other health factors that may indicate an increase in the patient's chances of developing a health condition or disease, such as breast cancer.
111516 Medication Type A classification of a medicinal substance, such as hormonal contraceptive or antibiotic.
111517 Relevant Patient Information Historical patient health information for general purpose use.
111518 Age when first menstrual period occurred The age of the patient at the first occurrence of menses.
111519 Age at First Full Term Pregnancy The age of the patient at the time of her first full term pregnancy.
111520 Age at Menopause The age of the patient at the cessation of menses.
111521 Age when hysterectomy performed The age of the patient at the time her uterus was removed.
111522 Age when left ovary removed The age of the patient at the time she had her left ovary removed.
111523 Age when right ovary removed The age of the patient at the time she had her right ovary removed.
111524 Age Started The age of a patient on the first occurrence of an event, such as the first use of a medication.
111525 Age Ended The age of a patient on the last occurrence of an event, such as the last use of a medication.
111526 DateTime Started The date and time of the first occurrence of an event, such as the first use of a medication.
111527 DateTime Ended The date and time of the last occurrence of an event, such as the last use of a medication.
111528 Ongoing An indicator of whether an event is still in progress, such as the use of a medication or substance, or environmental exposure.
111529 Brand Name Product name of a device or substance, such as medication, to identify it as the product of a single firm or manufacturer.
111530 Risk Factor modifier A descriptor that further qualifies or characterizes a risk factor.
111531 Previous Procedure A prior non-interventional study or interventional procedure performed on a patient.
111532 Pregnancy Status Describes the pregnancy state of a referenced subject.
111533 Indicated Problem A symptom experienced by a patient that is used as the reason for performing a study or procedure.
111534 Role of person reporting The function of the individual who is reporting information on a patient, which could be a specific health care related profession, the patient him/herself, or a relative or friend.
111535 DateTime problem observed The date and time that a symptom was noted.
111536 DateTime of last evaluation The date and time of the most recent evaluation of an indicated problem.
111537 Family Member with Risk Factor A patient's biological relative who exhibits a health factor that may indicate an increase in the patient's chances of developing a particular disease or medical problem.
111538 Age at Occurrence The age at which an individual experienced a specific event, such as breast cancer.
111539 Menopausal phase The current stage of an individual in her gynecological development.
111540 Side of Family An indicator of paternal or maternal relationship.
111541 Maternal Relating to biological female parentage.
111542 Unspecified gynecological hormone A gynecological hormone for which the specific type is not specified.
111543 Breast feeding history An indicator of whether or not a patient ever provided breast milk to her offspring.
111544 Average breast feeding period The average length of time that a patient provided breast milk to her offspring.
111545 Substance Use History Information regarding usage by the patient of certain legal or illicit substances.
111546 Used Substance Type A classification of a substance, such as alcohol or a legal or illicit drug.
111547 Environmental Exposure History Information regarding exposure of the patient to potentially harmful environmental factors.
111548 Environmental Factor A classification of a potentially harmful substance or gas in a subject's environment, such as asbestos, lead, or carcinogens.
111549 Previous Reports Previous Structured Reports that could have relevant information for a current imaging service request.
111550 Personal breast cancer history An indication that a patient has had a previous malignancy of the breast.
111551 History of endometrial cancer Indicates a previous occurrence of cancer of the lining of the uterus.
111552 History of ovarian cancer Indicates a previous occurrence of cancer of the lining of the ovary.
111553 History of high risk lesion on previous biopsy Indicates a prior diagnosis of pre-cancerous cells or tissue removed for pathologic evaluation.
111554 Post menopausal patient A female patient whose menstrual periods have ceased.
111555 Late child bearing (after 30) A female patient whose first child was born after the patient was 30 years old.
111556 BRCA1 breast cancer gene The first level genetic marker indicating risk for breast cancer.
111557 BRCA2 breast cancer gene The second level genetic marker indicating risk for breast cancer.
111558 BRCA3 breast cancer gene The third level genetic marker indicating risk for breast cancer.
111559 Weak family history of breast cancer A patient's biological aunt, grandmother, or female cousin was diagnosed with breast cancer. Definition from BI-RADS®.
111560 Intermediate family history of breast cancer A patient's biological mother or sister was diagnosed with breast cancer after they had gone through menopause. Definition from BI-RADS®.
111561 Very strong family history of breast cancer A patient's biological mother or sister was diagnosed with breast cancer before they had gone through menopause, or more than one of the patient's first-degree relatives (biological mother or sister) were diagnosed with breast cancer after they had gone through menopause. Definition from BI-RADS®.
111562 Family history of prostate cancer Previous diagnosis of a malignancy of the prostate gland in a biological relative.
111563 Family history unknown The health record of a patient's biological relatives is not known.
111564 Nipple discharge cytology The study of cells obtained from fluid emitted from the breast.
111565 Uterine malformations A developmental abnormality resulting in an abnormal shape of the uterus.
111566 Spontaneous Abortion A naturally occurring premature expulsion from the uterus of the products of conception - the embryo or a nonviable fetus.
111567 Gynecologic condition An ailment/abnormality or state of the female reproductive tract.
111568 Gynecologic surgery A surgical operation performed on any portion of the female reproductive tract.
111569 Previous LBW or IUGR birth Prior pregnancy with a low birth weight baby or a fetus with Intrauterine Growth Restriction or Retardation.
111570 Previous fetal malformation/syndrome History of at least one prior pregnancy with fetal anatomic abnormality(s).
111571 Previous RH negative or blood dyscrasia at birth History of delivering a Rhesis Isoimmunization affected child(ren) or a child(ren) with another blood disorder.
111572 History of multiple fetuses History of at least one pregnancy that contained more than one fetus.
111573 Current pregnancy, known or suspected malformations/syndromes At least one fetus of this pregnancy has an anatomic abnormality(s) that is known to exist, or a "marker" is present that suggests the abnormality(s) may be present.
111574 Family history, fetal malformation/syndrome Biological relatives have previously conceived a fetus with an anatomic abnormality(s).
111575 High A subjective descriptor for an elevated amount of exposure, use, or dosage, incurring high risk of adverse effects.
111576 Medium A subjective descriptor for a moderate amount of exposure, use, or dosage, incurring medium risk of adverse effects.
111577 Low A subjective descriptor for a limited amount of exposure, use, or dosage, incurring low risk of adverse effects.
111578 Dose frequency A measurement of the rate of occurrence of which a patient takes a certain medication.
111579 Rate of exposure The quantity per unit of time that a patient was or is being exposed to an environmental irritant.
111580 Volume of use The quantity per unit of time that a medication or substance was or is being used.
111581 Relative dose amount A qualitative descriptor for the amount of a medication that was or is being taken.
111582 Relative amount of exposure A qualitative descriptor for the amount of present or past exposure to an environmental irritant.
111583 Relative amount of use A qualitative descriptor for the amount of a medication or substance that was or is being used.
111584 Relative dose frequency A qualitative descriptor for the frequency with which a medication was or is being taken.
111585 Relative frequency of exposure A qualitative descriptor for the frequency of present or past exposure to an environmental irritant.
111586 Relative frequency of use A qualitative descriptor for the frequency with which a medication or substance was or is being used.
111587 No known exposure Patient is not known to have been exposed to or used the substance or medication.
111590 Recall for technical reasons Patient returns for additional images to improve the quality of the most recent study.
111591 Recall for imaging findings Patient returns for additional images to clarify findings from the most recent study.
111592 Recall for patient symptoms/ clinical findings Patient returns for additional images to clarify symptoms or signs reported by the patient or a healthcare professional at the time of the most recent study.
111593 LBW or IUGR Number of births with low birth weight or intrauterine growth restriction.
111601 Green filter Filter that transmits green light while blocking the other colors, typically centered at 510-540 nm
111602 Red filter Filter that transmits red light while blocking the other colors, typically centered at 630-680 nm
111603 Blue filter Filter that transmits blue while blocking the other colors, typically centered at 460-480 nm
111604 Yellow-green filter A filter of 560nm that is used for retinal imaging and can provide good contrast and good visibility of the retinal vasculature
111605 Blue-green filter A filter of 490nm that is used for retinal imaging because of excessive scattering of some retinal structures at very short wavelengths
111606 Infrared filter Filter that transmits the infrared spectrum, which is light that lies outside of the visible spectrum, with wavelengths longer than those of red light, while blocking visible light
111607 Polarizing filter A filter that reduces reflections from non-metallic surfaces such as glass or water by blocking light waves that are vibrating at selected angles to the filter.
111609 No filter No filter used.
111621 Field 1 for Joslin 3 field Joslin NM-1 is a 45 degree field focused centrally between the temporal margin of optic disc and the center of the macula: Center the camera on the papillomacular bundle midway between the temporal margin of the optic disc and the center of the macula. The horizontal centerline of the image should pass directly through the center of the disc.
111622 Field 2 for Joslin 3 field Joslin NM-2 is a 45 degree field focused superior temporal to the optic disc: Center the camera laterally approximately one-half disc diameter temporal to the center of the macula. The lower edge of the field is tangent to a horizontal line passing through the upper edge of the optic disc. The image is taken temporal to the macula but includes more retinal nasal and superior to the macula than standard field 2.
111623 Field 3 for Joslin 3 field Joslin NM-3 is a 45 degree field focused nasal to the optic disc: This field is nasal to the optic disc and may include part of the optic disc. The horizontal centerline of the image should pass tangent to the lower edge of the optic disc.
111625 Diffuse direct illumination A broad or "soft" light supplied from a single source.
111626 Scheimpflug Camera A slit reflected light microscope, which has the ability to form an image of the back scattered light from the eye in a sagittal plane. Scheimpflug cameras are able to achieve a wide depth of focus by employing the "Sheimpflug principle" where the lens and image planes are not parallel with each other. Rotating Sheimplug cameras are able to generate three-dimensional images and calculate measurements of the anterior chamber of the eye.
111627 Scotopic light Lighting condition approximately 0.04 lux.
111628 Mesopic light Lighting condition approximately 4 lux.
111629 Photopic light Lighting condition approximately 40 lux.
111630 Dynamic light Acquisition preceded by intense light.
111631 Average Glandular Dose Calculated from values of entrance exposure in air, the X-Ray beam quality (half-value layer), and compressed breast thickness, is the energy deposited per unit mass of glandular tissue averaged over all the glandular tissue in the breast.
111632 Anode Target Material The primary material in the anode of an X-Ray source.
111633 Compression Thickness The average thickness of the body part examined when compressed, if compression has been applied during X-Ray exposure.
111634 Half Value Layer Thickness of Aluminum required to reduce the X-Ray output at the patient entrance surface by a factor of two.
111635 X-Ray Grid An anti-scatter device based on radiation absorbing strips above the detector.
111636 Entrance Exposure at RP Exposure measurement in air at the reference point that does not include back scatter, according to MQCM 1999.
111637 Accumulated Average Glandular Dose Average Glandular Dose to a single breast accumulated over multiple images.
111638 Patient Equivalent Thickness Value of the control variable used to parametrize the Automatic Exposure Control (AEC) closed loop.
111640 Virtual grid A processing algorithm used to reduce the effect of X-Ray scatter on image quality, similar to the use of a physical X-Ray anti-scatter grid.
111641 Fixed grid A physical X-Ray anti-scatter grid that does not move during exposure.
111642 Focused grid A physical X-Ray anti-scatter grid with radiation absorbing strips that are focused toward the focal spot, to eliminate grid cutoff.
111643 Reciprocating grid A physical X-Ray anti-scatter grid that is designed to move during exposure, to eliminate the appearance of grid lines on the image.
111644 Parallel grid A physical X-Ray anti-scatter grid with radiation absorbing strips that are parallel to each other and that is used only with long source to image distances.
111645 Crossed grid A physical X-Ray anti-scatter grid with crossed radiation absorbing strips used for more complete cleanup of scatter radiation.
111646 No grid No physical X-Ray anti-scatter grid was used due to low scatter conditions.
111647 Compression Force The compression force applied to the body part during exposure.
111648 Compression Pressure The average compression pressure applied to the body part during exposure.
111649 Compression Contact Area The area of the body part to which compression has been applied during exposure.
111671 Spectacle Prescription Report The spectacle prescription for a patient.
111672 Add Near Refractive measurements of the eye to correct for inability to focus at near while wearing the distance prescription.
111673 Add Intermediate Refractive measurements of the eye to correct for inability to focus at intermediate distance while wearing the distance prescription.
111674 Add Other Refractive measurements of the eye to correct for inability to focus at the specified distance while wearing the distance prescription.
111675 Horizontal Prism Power The power of a prism to bend light in the horizontal direction, in prism diopters.
111676 Horizontal Prism Base Direction of the base of a horizontal prism -- either in (toward the nose), or out (away from the nose).
111677 Vertical Prism Power The power of a prism to bend light in the vertical direction, in prism diopters.
111678 Vertical Prism Base Direction of the base of a vertical prism -- either up, or down.
111679 Distance Pupillary Distance Distance in mm between the pupils when the patient's object of regard is in the distance.
111680 Near Pupillary Distance Distance in mm between the pupils when the patient's object of regard is at near.
111681 SMILE Small Incision Lenticule Extraction. Refractive surgery procedure where a thin lenticule is cleaved from the corneal stroma using a femtosecond laser and then extracted through a small incision in the corneal periphery.
111685 Autorefraction Visual Acuity A patient's vision with the correction measured by an autorefractor in place.
111686 Habitual Visual Acuity A patient's vision with whichever vision correction the patient customarily wears.
111687 Prescription Visual Acuity A patient's vision with the final spectacle prescription in place.
111688 Right Eye Rx The spectacle prescription for the right eye.
111689 Left Eye Rx The spectacle prescription for the left eye.
111690 Macular Grid Thickness and Volume Report A macular grid thickness and volume report for a patient. The macular grid is an analytic tool described in .
111691 Number of Images Used for Macular Measurements Number of images used for the macular grid measurement.
111692 Number of Samples Used per Image Number of samples used per Image for analysis.
111693 Analysis Quality Rating A numeric rating of the quality of the entire analysis with respect to grading and diagnostic purposes.Higher numbers indicate greater quality.
111694 Image Set Quality Rating A numeric rating of the quality of an entire image set with respect to grading and diagnostic purposes.Higher numbers indicate greater quality.
111695 Interfering Tears or Drops Tear film or drops affecting test quality.
111696 Visual Fixation Quality During Acquisition The assessment of the centricity and persistence of the visual fixation (direction of gaze) during the acquisition.
111697 Visual Fixation Quality Problem The reason why the patient's visual fixation was not steady or was indeterminate.
111698 Ophthalmic Macular Grid Problem The reason why the macular grid measurements may be questionable.
111700 Specimen Container Identifier Identifier of container (box, block, microscope slide, etc.) for the specimen under observation.
111701 Processing type Type of processing that tissue specimen underwent.
111702 DateTime of processing Date and time of processing step.
111703 Processing step description Description of the individual step in the tissue processing sequence.
111704 Sampling Method Method of sampling used to derive specimen from its parent.
111705 Parent Specimen Identifier Identifier of the parent specimen that gave rise to the current specimen.
111706 Issuer of Parent Specimen Identifier Assigning authority for parent specimen's identifier.
111707 Parent specimen type Parent specimen type that gave rise to current specimen.
111708 Position Frame of Reference Description of coordinate system and origin reference point on parent specimen, or parent specimen container, or image used for localizing the sampling site or location within container or image.
111709 Location of sampling site Reference to image of parent specimen localizing the sampling site; may include referenced Presentation State object.
111710 Location of sampling site X offset Location of sampling site of specimen (nominal center) relative to the Position Frame of Reference.
111711 Location of sampling site Y offset Location of sampling site of specimen (nominal center) relative to the Position Frame of Reference.
111712 Location of sampling site Z offset Location of sampling site of specimen (nominal center) relative to the Position Frame of Reference.
111718 Location of Specimen Description of specimen location, either in absolute terms or relative to the Position Frame of Reference.
111719 Location of Specimen X offset Location of specimen (nominal center) relative to the Position Frame of Reference in the X dimension.
111720 Location of Specimen Y offset Location of specimen (nominal center) relative to the Position Frame of Reference in the Y dimension.
111721 Location of Specimen Z offset Location of specimen (nominal center) relative to the Position Frame of Reference in the Z dimension.
111723 Visual Marking of Specimen Description of visual distinguishing identifiers.
111724 Issuer of Specimen Identifier Assigning authority for specimen identifier.
111726 Dissection with entire specimen submission Dissection of specimen with submission of all its sections for further processing or examination.
111727 Dissection with representative sections submission Dissection of specimen with submission of representative sections for further processing or examination.
111729 Specimen storage A workflow step, during which tissue specimens are stored in a climate-controlled environment.
111741 Transmission illumination Transmission illumination method for specimen microscopy.
111742 Reflection illumination Reflection illumination method for specimen microscopy.
111743 Epifluorescence illumination Epifluorescence illumination method for specimen microscopy.
111744 Brightfield illumination Brightfield illumination method for specimen microscopy.
111745 Darkfield illumination Darkfield illumination method for specimen microscopy.
111746 Oblique illumination Oblique illumination method for specimen microscopy.
111747 Phase contrast illumination Phase contrast illumination method for specimen microscopy.
111748 Differential interference contrast Differential interference contrast method for specimen microscopy.
111749 Total internal reflection fluorescence Total internal reflection fluorescence method for specimen microscopy.
111750 Ultrasound Contact A method of obtaining ophthalmic axial measurements that uses ultrasound, and that requires applanation of the cornea.
111751 Ultrasound Immersion A method of obtaining ophthalmic axial measurements that uses ultrasound, and that requires immersion of the patient's eye in fluid as he lies in a supine position.
111752 Optical A method of obtaining ophthalmic axial measurements that uses light.
111753 Manual Keratometry Measurements taken of the corneal curvature using a manual keratometer.
111754 Auto Keratometry Measurements taken of the corneal curvature using an automated keratometer.
111755 Simulated Keratometry Simulated Keratometry measurements derived from corneal topography.
111756 Equivalent K-reading Corneal power measurements using Scheimpflug camera.
111757 Keratometry Measurements SOP Instance Keratometry Measurements DICOM SOP Instance.
111758 Total Cornea Power Measurement Method Method of determining the total cornea power from measuring the curvature of both anterior and posterior surface of the cornea.
111759 Posterior Cornea Surface Measurement Method Method of measuring the curvature of posterior surface of the cornea and determining its refractive power.
111760 Haigis The Haigis IOL calculation formula.Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 2000;238:765-73.
111761 Haigis-L The Haigis-L IOL calculation formula.Haigis W. Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg. 2008 Oct;34(10):1658-63.
111762 Holladay 1 The Holladay 1 IOL calculation formula.Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruiz RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988; 14:17-24.
111763 Holladay 2 The Holladay 2 IOL calculation formula.
111764 Hoffer Q The Hoffer Q IOL calculation formula. Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 1993;19:700-12. Errata. J Cataract Refract Surg 1994;20:677 and 2007;33:2-3.
111765 Olsen The Olsen IOL calculation formula. Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol. Scand. 2007: 85: 472-485.
111766 SRKII The SRKII IOL calculation formula. Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II formula and other second generation formulas. J Cataract Refract Surg. 1988 Mar;14(2):136-41.
111767 SRK-T The SRK-T IOL calculation formula.Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 1990;16:333-40. Erratum 1990;16:528.
111768 ACD Constant The "ACD Constant" used in IOL calculation.
111769 Haigis a0 The "Haigis a0" constant used in IOL calculation.
111770 Haigis a1 The "Haigis a1" constant used in IOL calculation.
111771 Haigis a2 The "Haigis a2" constant used in IOL calculation.
111772 Hoffer pACD Constant The "Hoffer pACD Constant" used in IOL calculation.
111773 Surgeon Factor The "Surgeon Factor" constant used in IOL calculation.
111776 Front Of Cornea To Front Of Lens Anterior chamber depth defined as the front of the cornea to the front of the lens.
111777 Back Of Cornea To Front Of Lens Anterior chamber depth defined as the back of the cornea to the front of the lens.
111778 Single or Anterior Lens Refers to the anterior lens when there are two lenses in the eye. The distance, in mm, from the anterior surface of the lens to the posterior surface of the lens.
111779 Posterior Lens Refers to the posterior lens when there are two lenses in the eye. The distance, in mm, from the anterior surface of the lens to the posterior surface of the lens.
111780 Measurement From This Device Value obtained from measurements taken by the device creating this SOP Instance.
111781 External Data Source Value obtained by data transfer from an external source - not from measurements taken by the device providing the value.
111782 Axial Measurements SOP Instance Axial Measurements DICOM SOP Instance.
111783 Refractive Measurements SOP Instance Refractive Measurements DICOM SOP Instance.
111784 Autorefraction Measurements SOP Instance Autorefraction Measurements DICOM SOP Instance.
111786 Standard Deviation of measurements used Standard Deviation is a simple measure of the variability of data.
111787 Signal to Noise Ratio Signal to Noise Ratio of the data samples taken to create a measurement.
111791 Spherical projection Projection from 2D image pixels to 3D Cartesian coordinates based on a spherical mathematical model.
111792 Surface contour mapping Mapping from 2D image pixels to 3D Cartesian coordinates based on measurements of the retinal surface.
111800 Visual Field 24-2 Test Pattern Test pattern, nominally covering an area within 24° of fixation. Consists of 54 test points a minimum of 3° from each meridian and placed 6° apart.The "-2" distinguishes this from another 24° pattern (no longer supported).
111801 Visual Field 10-2 Test Pattern Test pattern, nominally covering an area within 10° of fixation. Consists of 68 test points a minimum of 1° from each meridian and placed 2° apart.The "-2" in this case indicates its point layout to be similar to the 30-2 and 24-2.
111802 Visual Field 30-2 Test Pattern Test pattern consisting of test point locations within 30° of fixation. Consists of 76 test points a minimum of 3° from each meridian and placed 6° apart.The "-2" distinguishes this from another 30° pattern (no longer supported).
111803 Visual Field 60-4 Test Pattern Test pattern consisting of 60 test point locations between 30° and 60° of fixation a minimum of 6° from each meridian and placed 12° apart.The "-4" distinguishes this from a similar 60° pattern having 4 additional points.
111804 Visual Field Macula Test Pattern Test pattern consisting of 16 test point locations within 10° of fixation a minimum of 1° from each meridian and placed 2° apart.
111805 Visual Field Central 40 Point Test Pattern Test pattern consisting of 40 test point locations within 30° of fixation that spread out radially from fixation.
111806 Visual Field Central 76 Point Test Pattern Test pattern consisting of 76 test point locations within 30° of fixation a minimum of 3° from each meridian and placed 6° apart.
111807 Visual Field Peripheral 60 Point Test Pattern Test pattern consisting of 60 test point locations between 30° and 60° of fixation a minimum of 6° from each meridian and placed 12° apart.
111808 Visual Field Full Field 81 Point Test Pattern Test pattern consisting of 81 test point locations within 60° of fixation that spread out radially from fixation.
111809 Visual Field Full Field 120 Point Test Pattern Test pattern consisting of 120 test point locations within 60° of fixation that spread out radially from fixation, concentrated in the nasal hemisphere.
111810 Visual Field G Test Pattern Test pattern for Glaucoma and general visual field assessment with 59 test locations of which 16 test locations are in the macular area (up to 10° eccentricity) and where the density of test location is reduced with eccentricity. The test can be extended with the inclusion of 14 test locations between 30° and 60° eccentricity, 6 of which are located at the nasal step.
111811 Visual Field M Test Pattern Test pattern for the macular area. Orthogonal test pattern with 0.7° spacing within the central 4° of eccentricity and reduced density of test locations between 4 and 10, 5° of eccentricity. 81 test locations over all. The test can be extended to include the test locations of the Visual Field G Test Pattern between 10, 5° and 60°.
111812 Visual Field 07 Test Pattern Full field test pattern with 48 test locations from 0-30° and 82 test locations from 30-70°. Reduced test point density with increased eccentricity. Can be combined with screening and threshold strategies.
111813 Visual Field LVC Test Pattern Low Vision Central. Orthogonal off-center test pattern with 6° spacing. 75 test locations within the central 30°. Corresponds with the 32/30-2 excluding the 2 locations at the blind spot, including a macular test location. The LVC is linked with a staircase threshold strategy starting at 0 dB intensity and applies stimulus area V.
111814 Visual Field Central Test Pattern General test corresponding to the 30-2 but excluding the 2 test locations in the blind spot area, hence with 74 instead of 76 test locations.
111815 Visual Field SITA-Standard Test Strategy Swedish Interactive Thresholding Algorithm (SITA). Strategy gains testing efficiency through use of visual field and information theory models.In: Bengtsson B, Olsson J, Heijl A, Rootzen H. A new generation of algorithms for computerized threshold perimetry, SITA. Acta Ophthalmologica Scandinavica, 1997, 75: 368-375.
111816 Visual Field SITA-SWAP Test Strategy Adaptation of SITA testing methods to Blue-Yellow testing.
111817 Visual Field SITA-Fast Test Strategy Similar to SITA-Standard but with less strict criteria for closing test points. Intended for patients who must be tested in the shortest possible time.In: Bengtsson B, Hejl A. SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmologica Scandinavica, 1998, 76: 431-437.
111818 Visual Field Full Threshold Test Strategy Threshold test algorithm that determines a patient's sensitivity at each test point in the threshold test pattern by adjusting intensity by 4 dB steps until the patient changes their response, and then adjusts the intensity in the opposite direction by 2 dB steps until the patient changes their response again. The last stimulus seen by the patient is recognized as the threshold for that point.The starting values are determined by first thresholding a "primary" point in each quadrant then using the results of each primary point to determine the starting values for neighboring points.
111819 Visual Field FastPac Test Strategy Similar to the Full Threshold algorithm except that it steps by 3 dB and only crosses the threshold only once.In: Flanagan JG, Wild JM, Trope GE. Evaluation of FASTPAC, a new strategy for threshold estimation with the Humphrey Field Analyzer, in a glaucomatous population. Ophthalmology, 1993, 100: 949-954.
111820 Visual Field Full From Prior Test Strategy Identical to Full Threshold except that starting values are determined by the results of a previous test performed using the same test pattern and the Full Threshold test strategy.
111821 Visual Field Optima Test Strategy Similar to FastPac except that the steps are pseudo-dynamic (differ based on the intensity of the last presentation).
111822 Visual Field Two-Zone Test Strategy Suprathreshold testing strategy, in which each point is initially tested using stimulus that is 6 dB brighter than the expected hill of vision. If the patient does not respond, the stimulus is presented a second time at the same brightness. If the patient sees either presentation, the point is marked as "seen"; otherwise it is marked as "not seen".
111823 Visual Field Three-Zone Test Strategy An extension of the two-zone strategy in which test points where the second stimulus is not seen are presented with a third stimulus at maximum brightness.
111824 Visual Field Quantify-Defects Test Strategy An extension of the two-zone strategy, in which test points where the second stimulus is not seen receive threshold testing to quantify the depth of any detected scotomas.
111825 Visual Field TOP Test Strategy Tendency Oriented Perimetry. Fast thresholding algorithm. Test strategy makes use of the interaction between neighboring test locations to reduce the test time compared to normal full threshold strategy by 60-80%.In: Morales J, Weitzman ML, Gonzalez de la Rosa M. Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry. Ophthalmology, 2000, 107: 134-142.
111826 Visual Field Dynamic Test Strategy Dynamic strategy is a fast thresholding strategy reducing test duration by adapting the dB step sizes according to the frequency-of-seeing curve of the threshold. Reduction of test time compared to normal full threshold strategy 30-50%.
111827 Visual Field Normal Test Strategy Traditional full threshold staircase strategy. Initial intensities are presented, based on anchor point sensitivities in each quadrant and based on already known neighboring sensitivities. In a first run, thresholds are changed in 4dB steps until the first response reversal. Then the threshold is changed in 2 dB steps until the second response reversal. The threshold is calculated as the average between the last seen and last not-seen stimulus, supposed to correspond with the 50% point in the frequency-of-seeing curve.
111828 Visual Field 1-LT Test Strategy One level screening test: Each test location is tested with a single intensity. The result is shown as seen or not-seen. The intensity can either be a 0 dB stimulus or a predefined intensity.
111829 Visual Field 2-LT Test Strategy Two level screening test: Each test location is initially tested 6 dB brighter than the age corrected normal value.
111830 Visual Field LVS Test Strategy Low Vision Strategy is a full threshold normal strategy with the exception that it starts at 0 dB intensity and applies stimulus area V.
111831 Visual Field GATE Test Strategy German Adaptive Threshold Estimation is a fast strategy based on a modified 4-2 staircase algorithm, using prior visual fields to calculate the starting intensity. In: Chiefer U, Pascual JP, Edmunds B, Feudner E, Hoffmann EM, Johnson CA, Lagreze WA, Pfeiffer N, Sample PA, Staubach F, Weleber RG, Vonthein R, Krapp E, Paetzold J. Comparison of the new perimetric GATE strategy with conventional full-threshold and SITA standard strategies. Investigative Ophthalmology and Visual Science, 2009, 51: 488-494.
111832 Visual Field GATEi Test Strategy Similar to GATE. The i stands for initial. If there was no prior visual field test to calculate the starting values, an anchor point method is used to define the local start values.
111833 Visual Field 2LT-Dynamic Test Strategy A test started as two level screening test. In the course of the test, the threshold of relative defects and/or normal test locations has been quantified using the dynamic threshold strategy.
111834 Visual Field 2LT-Normal Test Strategy A test started as two level screening test. In the course of the test, the threshold of relative defects and/or normal test locations has been quantified using the normal full threshold strategy.
111835 Visual Field Fast Threshold Test Strategy Takes neighborhood test point results into account and offers stimuli with an adapted value to save time.
111836 Visual Field CLIP Test Strategy Continuous Luminance Incremental Perimetry, which measures at first the individual reaction time of the patient and threshold values in every quadrant. The starting value for the main test is slightly below in individual threshold.
111837 Visual Field CLASS Strategy A supra threshold screening strategy. The starting stimuli intensities depend on the classification of the patient's visual hill by measuring the central (fovea) or peripheral (15° meridian) threshold. The result of each dot slightly underestimates the sensitivity value (within 5 dB).
111838 Age corrected Mode for determining the starting luminance for screening test points - the starting luminance s is chosen based on the age of the patient.
111839 Threshold related Mode for determining the starting luminance for screening test points - the starting luminance is chosen based on the results of thresholding a set of "primary" test points (one in each quadrant).
111840 Single luminance Mode for determining the starting luminance for screening test points - in this case, all starting luminance is set to the same value.
111841 Foveal sensitivity related Mode for determining the starting luminance for screening test points - the starting luminance is chosen based on the result of the foveal threshold value.
111842 Related to non macular sensitivity Mode for determining the starting luminance for screening test points - the starting luminance is chosen based on the result of four threshold values measured near the 15° meridian (one in each quadrant).
111843 Automated Optical Real time evaluation of the camera image to recognize blinks and fixation losses with influence on the test procedure. Blinks that interfere with stimuli presentation cause the automated repetition of such stimulus presentations. Fixation losses can be used to delay the stimulus presentation until correct fixation is regained.
111844 Blind Spot Monitoring A method of monitoring the patient's fixation by periodically presenting stimulus in a location on the background surface that corresponds to the patient's blind spot.
111845 Macular Fixation Testing A method of monitoring the patient's fixation by presenting the stimulus to the patient's macula.
111846 Observation by Examiner A method of monitoring the patient's fixation by observation from the examiner of the patient.
111847 Outside normal limits Analysis Results are outside normal limits.
111848 Borderline Analysis Results are borderline.
111849 Abnormally high sensitivity Analysis Results identify abnormally high sensitivity.
111850 General reduction in sensitivity Analysis Results identify general reduction in sensitivity.
111851 Borderline and general reduction in sensitivity Analysis Results identify Borderline and general reduction in sensitivity.
111852 Visual Field Index Index of a patient's remaining visual field normalized for both age and generalized defect.
111853 Visual Field Loss Due to Diffuse Defect Estimate of the portion of a patient's visual field loss that is diffuse (i.e., spread evenly across all portions of the visual field).
111854 Visual Field Loss Due to Local Defect Estimate of the portion of a patient's visual field loss that is local (i.e., not spread evenly across all portions of the visual field).
111855 Glaucoma Hemifield Test Analysis An analysis of asymmetry between zones of the superior and inferior visual field. It is designed to be specific for defects due to glaucoma.
111856 Optical Fixation Measurements The data output of an optical fixation monitoring process, consisting of a list of positive and negative numbers indicating the quality of patient fixation over the course of a visual field test. The value 0 represents the initial fixation. Negative numbers indicate a measuring error (i.e., the patient blinked). Positive numbers quantify the degree of eccentricity from initial fixation.
111860 Haigis Toric The Haigis Toric IOL calculation formula.Haigis, Wolfgang. Toric Iol Power Calculation. 2014.
111861 Haigis-L Toric The Haigis-L Toric IOL calculation formula.Haigis W, Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg, 2008. 34(10): 1658-63. doi:10.1016/j.jcrs.2008.06.029
111862 Barrett Toric The Barrett Toric IOL calculation formula.Abulafia, A., et al., Prediction of refractive outcomes with toric intraocular lens implantation. J Cataract Refract Surg, 2015. 41(5): p. 936-44. doi:10.1016/j.jcrs.2014.08.036
111863 Barrett True-K The Barrett True-K IOL calculation formula.Abulafia, A., et al., Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg, 2016. 42(3): p. 363-9. doi:10.1016/j.jcrs.2015.11.039
111864 Barrett True-K Toric The Barrett True-K Toric IOL calculation formula.Barrett G.D., Barrett True-K toric calculator.
111865 Barrett Universal II The Barrett Universal II IOL calculation formula.Barrett, G.D., An improved universal theoretical formula for intraocular lens power prediction. J Cataract Refract Surg, 1993. 19: p. 713-720. doi:10.1016/S0886-3350(13)80339-2
111866 Barrett Lens Factor The "Barrett Lens Factor" constant used in IOL calculation.
111867 Barrett Design Factor The "Barrett Design Factor" constant used in IOL calculation.
111900 Macula centered An image of at least 15° angular subtend that is centered on the macula.
111901 Disc centered An image of at least 15° angular subtend that is centered on the optic disc.
111902 Lesion centered An image of any angular subtend that is centered on a lesion located in any region of the fundus.
111903 Disc-macula centered An image of at least 15° angular subtend centered midway between the disc and macula and containing at least a portion of the disc and both the disc and the macula.
111904 Mid-peripheral-superior An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the superior-temporal and superior-nasal quadrants of the fundus.
111905 Mid-peripheral-superior temporal An image of at least 15° angular subtend positioned between the central zone and the equator in the superior-temporal quadrant of the fundus.
111906 Mid-peripheral-temporal An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the superior-temporal and inferior-temporal quadrants of the fundus.
111907 Mid-peripheral-inferior temporal An image of at least 15° angular subtend positioned between the central zone and the equator in the inferior-temporal quadrant of the fundus.
111908 Mid-peripheral-inferior An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the inferior-temporal and inferior-nasal quadrants of the fundus.
111909 Mid-peripheral-inferior nasal An image of at least 15° angular subtend positioned between the central zone and the equator in the inferior-nasal quadrant of the fundus.
111910 Mid-peripheral-nasal An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the superior-nasal and inferior-nasal quadrants of the fundus.
111911 Mid-peripheral-superior nasal An image of at least 15° angular subtend positioned between the central zone and the equator in the superior-nasal quadrant of the fundus.
111912 Peripheral-superior An image of at least 15° angular subtend positioned between the equator and the ora serrata, and spanning both the superior temporal and superior nasal quadrants of the fundus.
111913 Peripheral-superior temporal An image of at least 15° angular subtend positioned between the equator and ora serrata in the superior-temporal quadrant of the fundus.
111914 Peripheral-temporal An image of at least 15° angular subtend positioned between the equator and ora serrata, and spanning both the superior-temporal and inferior-temporal quadrants of the fundus.
111915 Peripheral-inferior temporal An image of at least 15° angular subtend positioned between the equator and ora serrata in the inferior-temporal quadrant of the fundus.
111916 Peripheral-inferior An image of at least 15° angular subtend positioned between the equator and ora serrata, and spanning both the inferior-temporal and inferior-nasal quadrants of the fundus.
111917 Peripheral-inferior nasal An image of at least 15° angular subtend positioned between the equator and ora serrata in the inferior-nasal quadrant of the fundus.
111918 Peripheral-nasal An image of at least 15° angular subtend positioned between the equator and ora serrata, and spanning both the superior-nasal and inferior-nasal quadrants of the fundus.
111919 Peripheral-superior nasal An image of at least 15° angular subtend positioned between the equator and ora serrata in the superior-nasal quadrant of the fundus.
111920 Time domain Identifies the use of physical signals with respect to time to capture information.
111921 Spectral domain Identifies the use of physical signals with respect to multiple frequencies to capture information.
111922 No corneal compensation No compensation algorithm for corneal birefringence.
111923 Corneal birefringence compensation Algorithm to compensate for variability in corneal birefringence.
111924 Retinal topography Measurement of the retinal surface contour relative to an assigned datum plane.
111925 Retinal nerve fiber layer thickness Measurement approximating the distance related to the structure between the internal limiting membrane (ILM) and the outer boarder of the retinal nerve fiber layer (RNFL).
111926 Ganglion cell complex thickness Measurement approximating the distance related to the structure between the ILM and the outer border of the inner plexiform layer (IPL), called the ganglion cell complex (GCC).
111927 Total retinal thickness (ILM to IS-OS) Measurement approximating the distance related to the structure between the ILM and the inner-outer segment junction (IS-OS).
111928 Total retinal thickness (ILM to RPE) Measurement approximating the distance related to the structure between the ILM and the retinal pigment epithelium (RPE).
111929 Total retinal thickness (ILM to BM) Measurement approximating the distance related to the structure between the ILM and the Bruch's membrane (BM).
111930 Absolute ophthalmic thickness Thickness of a component of the posterior segment of the eye.
111931 Thickness deviation category from normative data Ophthalmic Thickness map based upon statistical significance category (such as percentile) from normative data.
111932 Thickness deviation from normative data Ophthalmic Thickness map based upon deviation (such as microns) from normative data.
111933 Related ophthalmic thickness map Ophthalmic Thickness Map related to another Ophthalmic Thickness Map or another SOP Instance.
111934 Disc-Fovea An anatomic point centered midway between the disc and fovea centralis.
111935 p>5% Assuming the null hypothesis is true, the conditional percent probability of observing this result is not statistically significant.
111936 p<5% Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 95% unlikely to happen by chance.
111937 p<2% Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 98% unlikely to happen by chance.
111938 p<1% Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 99% unlikely to happen by chance.
111939 p<0.5% Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 99.5% unlikely to happen by chance.
111940 Corneal axial power map A two dimensional representation of the axial curvature of the cornea. Axial curvature is calculated from the reciprocal of the distance from a point on a meridian normal at the point to the corneal topographer axis. Also known as sagittal curvature.
111941 Corneal instantaneous power map A two dimensional representation of the instantaneous curvature of the cornea. Instantaneous curvature is calculated from the reciprocal of the distance from a point on a meridian normal at the point to the center of curvature of that point. Also called tangential curvature.
111942 Corneal refractive power map A two dimensional representation of the refractive power of the cornea. Corneal refractive power is calculated using Snell's Law.
111943 Corneal elevation map A two dimensional representation of the elevation of the cornea. Elevation is calculated as the distance from a point on the corneal surface to a point on a reference surface along a line parallel to the corneal topographer axis. For the purpose of visualization the reference surface is usually a sphere or an ellipse.
111944 Corneal wavefront map A two dimensional representation of a wavefront aberration surface of the cornea. Wavefront aberration surface is calculated from the corneal elevation data fit with either the Zernike polynomial series or the Fourier Series. Maps generally display total aberrations and selectable higher order aberrations.
111945 Elevation-based corneal tomographer A device that measures corneal anterior surface shape using elevation-based methods (stereographic and light slit-based). Rasterstereography images a grid pattern illuminating the fluorescein dyed tear film with 2 cameras to produce 3D. Slit-based devices scan the cornea, usually by rotation about the instrument axis centered on the cornea vertex.
111946 Reflection-based corneal topographer A reflection-based device that projects a pattern of light onto the cornea and an image of the reflection of that pattern from the tear film is recorded in one video frame. Light patterns include the circular mire pattern (Placido disc) and spot matrix patterns. Sequential scanning of light spots reflected from the corneal surface is also used requiring multiple video frames for recording.
111947 Interferometry-based corneal tomographer An Interference-based device that projects a beam of light onto and through the cornea. Light reflected from within the cornea is combined with a reference beam giving rise to an interference pattern. Appropriately scanned, this imaging is used to construct 3-dimensional images of the cornea from anterior to posterior surfaces.
112000 Chest CAD Report A structured report containing the results of computer-aided detection or diagnosis applied to chest imaging and associated clinical information.
112001 Opacity The shadow of an absorber that attenuates the X-Ray beam more effectively than do surrounding absorbers. In a radiograph, any circumscribed area that appears more nearly white (of lesser photometric density) than its surround [Fraser and Pare].
112002 Series Instance UID A unique identifier for a series of DICOM SOP instances.
112003 Associated Chest Component A named anatomic region within the chest cavity.
112004 Abnormal interstitial pattern A collection of opacities detected within the continuum of loose connective tissue throughout the lung, that is not expected in a diagnostically normal radiograph.
112005 Radiographic anatomy A type of anatomy that is expected to be detectable on a radiographic (X-Ray based) image.
112006 Distribution Descriptor Characteristic of the extent of spreading of a finding or feature.
112007 Border definition Characteristic of the clarity of the boundary or edges of a finding or feature.
112008 Site involvement The part(s) of the anatomy affected or encompassed by a finding or feature.
112009 Type of Content Characteristic of the matter or substance within a finding or feature.
112010 Texture Descriptor Characteristic of the surface or consistency of a finding or feature.
112011 Positioner Primary Angle Position of the X-Ray beam about the patient from the RAO to LAO direction where movement from RAO to vertical is positive.
112012 Positioner Secondary Angle Position of the X-Ray beam about the patient from the caudal to cranial direction where movement from caudal to vertical is positive.
112013 Location in Chest The zone, lobe or segment within the chest cavity in which a finding or feature is situated.
112014 Orientation Descriptor Vertical refers to orientation parallel to the superior-inferior (cephalad-caudad) axis of the body, with horizontal being perpendicular to this, and an oblique orientation having projections in both the horizontal and vertical.
112015 Border shape Characteristic of the shape formed by the boundary or edges of a finding or feature.
112016 Baseline Category Indicates whether a finding was considered a target lesion, non-target lesion, or non-lesion during evaluation of a baseline series, according to a method such as RECIST.
112017 Cavity extent as percent of volume The extent of a detected cavity, represented as the percent of the surrounding volume that it occupies.
112018 Calcification extent as percent of surface The extent of a detected calcification, represented as the percent of the surrounding surface that it occupies.
112019 Calcification extent as percent of volume The extent of a detected calcification, represented as the percent of the surrounding volume that it occupies.
112020 Response Evaluation A heading for the reporting of response evaluation for treatment of solid tumors.
112021 Response Evaluation Method The system applied in the reporting of response evaluation for treatment of solid tumors.
112022 RECIST Response Evaluation Criteria In Solid Tumors.
112023 Composite Feature Modifier A term that further specifies the name of an item that is an inferred correlation relating two or more individual findings or features.
112024 Single Image Finding Modifier A term that further specifies the name of an item that was detected on one image.
112025 Size Descriptor A qualitative descriptor for the extent of a finding or feature.
112026 Width Descriptor A qualitative descriptor for the thickness of tubular structures, such as blood vessels.
112027 Opacity Descriptor A characteristic that further describes the nature of an opacity.
112028 Abnormal Distribution of Anatomic Structure The type of adverse affect that a finding or feature is having on the surrounding anatomy.
112029 WHO Response evaluation method as defined in chapter 5, "Reporting of Response" of the WHO Handbook for Reporting Results for Cancer Treatment.
112030 Calcification Descriptor Identification of the morphology of detected calcifications.
112031 Attenuation Coefficient A quantitative numerical statement of the relative attenuation of the X-Ray beam at a specified point. Coefficient that describes the fraction of a beam of X-Rays or gamma rays that is absorbed or scattered per unit thickness of the absorber. This value basically accounts for the number of atoms in a cubic cm volume of material and the probability of a photon being scattered or absorbed from the nucleus or an electron of one of these atoms. Usually expressed in Hounsfield units [referred to as CT Number in Fraser and Pare].
112032 Threshold Attenuation Coefficient An X-Ray attenuation coefficient that is used as a threshold.
112033 Abnormal opacity An opacity that is not expected in a diagnostically normal radiograph.
112034 Calculation Description A textual description of the mathematical method of calculation that resulted in a calculated value.
112035 Performance of Pediatric and Adult Chest Radiography, ACR American College of Radiology. ACR Standard for the Performance of Pediatric and Adult Chest Radiography. In: Standards. Reston, Va: 2001:95-98.
112036 ACR Position Statement American College of Radiology. ACR Position Statement for Quality Control and Improvement, Safety, Infection Control, and Patient Concerns. In: Practice Guidelines and Technical Standards. Reston, Va: 2001:iv.
112037 Non-lesion Modifier A descriptor for a non-lesion object finding or feature, used to indicate whether the object was detected as being internal or external to the patient's body.
112038 Osseous Modifier A concept modifier for an Osseous Anatomy, or bone related, finding.
112039 Tracking Identifier A text label used for tracking a finding or feature, potentially across multiple reporting objects, over time. This label shall be unique within the domain in which it is used. Corresponds to Tracking ID (0062,0020).
112040 Tracking Unique Identifier A unique identifier used for tracking a finding or feature, potentially across multiple reporting objects, over time. Corresponds to Tracking UID (0062,0021).
112041 Target Lesion Complete Response Disappearance of all target lesions.
112042 Target Lesion Partial Response At least a 30% decrease in the sum of the Longest Diameter of target lesions, taking as reference the baseline sum Longest Diameter.
112043 Target Lesion Progressive Disease At least a 20% increase in the sum of the Longest Diameter of target lesions, taking as reference the smallest sum Longest Diameter recorded since the treatment started, or the appearance of one or more new lesions.
112044 Target Lesion Stable Disease Neither sufficient shrinkage to qualify for Partial Response nor sufficient increase to qualify for Progressive Disease, taking as reference the smallest sum Longest Diameter since the treatment started.
112045 Non-Target Lesion Complete Response Disappearance of all non-target lesions and normalization of tumor marker level.
112046 Non-Target Lesion Incomplete Response or Stable Disease Persistence of one or more non-target lesions and/or maintenance of tumor marker level above the normal limits.
112047 Non-Target Lesion Progressive Disease Appearance of one or more new lesions and/or unequivocal progression of existing non-target lesions.
112048 Current Response The current response evaluation for treatment of solid tumors, according to a method such as RECIST.
112049 Best Overall Response Best response recorded from the start of the treatment until disease progression/recurrence, taking as reference for Progressive Disease the smallest measurements recorded since the treatment started, according to a method such as RECIST.
112050 Anatomic Identifier A text identifier of an anatomic feature when a multiplicity of features of that type may be present, such as "Rib 1", "Rib 2" or thoracic vertebrae "T1" or "T2".
112051 Measurement of Response A measured or calculated evaluation of response.
112052 Bronchovascular Of or relating to a bronchial (lung) specific channel for the conveyance of a body fluid.
112053 Osseous Of, relating to, or composed of bone.
112054 Secondary pulmonary lobule The smallest unit of lung surrounded by connective tissue septa; the unit of lung subtended by any bronchiole that gives off three to five terminal bronchioles [Fraser and Pare].
112055 Agatston scoring method A method of calculating an overall calcium score, reflecting the calcification of coronary arteries, based on the maximum X-Ray attenuation coefficient and the area of calcium deposits.
112056 Volume scoring method A method of calculating an overall calcium score, reflecting the calcification of coronary arteries, based on the volume of each calcification, typically expressed in mm3.
112057 Mass scoring method A method of calculating an overall calcium score, reflecting the calcification of coronary arteries, based on the total mass of calcification, typically expressed in mg.
112058 Calcium score A measure often arrived at through calculation of findings from CT examination, which is a common predictor of significant stenosis of the coronary arteries.
112059 Primary complex The combination of a focus of pneumonia due to a primary infection with granulomas in the draining hilar or mediastinal lymph nodes [Fraser and Pare].
112060 Oligemia General or local decrease in the apparent width of visible pulmonary vessels, suggesting less than normal blood flow (reduced blood flow) [Fraser and Pare].
112061 Abnormal lines (1D) Linear opacity of very fine width, i.e., a nearly one dimensional opacity.
112062 Abnormal lucency Area of abnormal very low X-Ray attenuation, typically lower than aerated lung when occurring in or projecting over lung, or lower than soft tissue when occurring in or projecting over soft tissue.
112063 Abnormal calcifications A calcific opacity within the lung that may be organized, but does not display the trabecular organization of true bone [Fraser and Pare].
112064 Abnormal texture Relatively homogeneous, extended, pattern of abnormal opacity in the lung, typically low in contrast.
112065 Reticulonodular pattern A collection of innumerable small, linear, and nodular opacities that together produce a composite appearance resembling a net with small superimposed nodules. The reticular and nodular elements are dimensionally of similar magnitude [Fraser and Pare].
112066 Beaded septum sign Irregular septal thickening that suggests the appearance of a row of beads; usually a sign of lymphangitic carcinomatosis, but may also occur rarely in sarcoidosis [Fraser and Pare].
112067 Nodular pattern A collection of innumerable, small discrete opacities ranging in diameter from 2-10 mm, generally uniform in size and widespread in distribution, and without marginal spiculation [Fraser and Pare].
112068 Pseudoplaque An irregular band of peripheral pulmonary opacity adjacent to visceral pleura that simulates the appearance of a pleural plaque and is formed by coalescence of small nodules [Fraser and Pare] .
112069 Signet-ring sign A ring of opacities (usually representing a dilated, thick-walled bronchus) in association with a smaller, round, soft tissue opacity (the adjacent pulmonary artery) suggesting a "signet ring" [Fraser and Pare].
112070 Air bronchiologram Equivalent of air bronchogram, but in airways assumed to be bronchioles because of peripheral location and diameter [Fraser and Pare].
112071 Air bronchogram Radiographic shadow of an air-containing bronchus; presumed to represent an air-containing segment of the bronchial tree (identity often inferred) [Fraser and Pare].
112072 Air crescent Air in a crescentic shape in a nodule or mass, in which the air separates the outer wall of the lesion from an inner sequestrum, which most commonly is a fungus ball of Aspergillusspecies [Fraser and Pare].
112073 Halo sign Ground-glass opacity surrounding the circumference of a nodule or mass. May be a sign of invasive aspergillosis or hemorrhage of various causes [Fraser and Pare].
112074 Target Lesion at Baseline Flag denoting that this lesion was identified, at baseline, as a target lesion intended for tracking over time [RECIST].
112075 Non-Target Lesion at Baseline Flag denoting that this lesion was not identified, at baseline, as a target lesion, and was not intended for tracking over time [RECIST].
112076 Non-Lesion at Baseline Flag denoting that this finding was identified, at baseline, as a category other than a lesion, and was not intended for tracking over time [RECIST].
112077 Vasoconstriction Local or general reduction in the caliber of visible pulmonary vessels, presumed to result from decreased flow occasioned by contraction of muscular pulmonary arteries [Fraser and Pare].
112078 Vasodilation Local or general increase in the width of visible pulmonary vessels resulting from increased pulmonary blood flow [Fraser and Pare].
112079 Architectural distortion A manifestation of lung disease in which bronchi, pulmonary vessels, a fissure or fissures, or septa of secondary pulmonary lobules are abnormally displaced [Fraser and Pare].
112080 Mosaic perfusion A patchwork of regions of varied attenuation, interpreted as secondary to regional differences in perfusion [Fraser and Pare].
112081 Pleonemia Increased blood flow to the lungs or a portion thereof, manifested by a general or local increase in the width of visible pulmonary vessels [Fraser and Pare].
112082 Interface The common boundary between the shadows of two juxtaposed structures or tissues of different texture or opacity (edge, border) [Fraser and Pare].
112083 Line A longitudinal opacity no greater than 2 mm in width [Fraser and Pare].
112084 Lucency The shadow of an absorber that attenuates the primary X-Ray beam less effectively than do surrounding absorbers. In a radiograph, any circumscribed area that appears more nearly black (of greater photometric density) than its surround [Fraser and Pare].
112085 Midlung window A midlung region, characterized by the absence of large blood vessels and by a paucity of small blood vessels, that corresponds to the minor fissure and adjacent peripheral lung [Fraser and Pare].
112086 Carina angle The angle formed by the right and left main bronchi at the tracheal bifurcation [Fraser and Pare].
112087 Centrilobular structures The pulmonary artery and its immediate branches in a secondary lobule; HRCT depicts these vessels in certain cases; a.k.a. core structures or lobular core structures [Fraser and Pare].
112088 Anterior junction line A vertically oriented linear or curvilinear opacity approximately 1-2 mm wide, commonly projected on the tracheal air shadow [Fraser and Pare].
112089 Posterior junction line A vertically oriented, linear or curvilinear opacity approximately 2 mm wide, commonly projected on the tracheal air shadow, and usually slightly concave to the right [Fraser and Pare].
112090 Azygoesophageal recess interface A space in the right side of the mediastinum into which the medial edge of the right lower lobe extends [Fraser and Pare].
112091 Paraspinal line A vertically oriented interface usually seen in a frontal chest radiograph to the left of the thoracic vertebral column [Fraser and Pare].
112092 Posterior tracheal stripe A vertically oriented linear opacity ranging in width from 2-5 mm, extending from the thoracic inlet to the bifurcation of the trachea, and visible only on lateral radiographs of the chest [Fraser and Pare].
112093 Right tracheal stripe A vertically oriented linear opacity approximately 2-3 mm wide extending from the thoracic inlet to the right tracheobronchial angle [Fraser and Pare].
112094 Stripe A longitudinal composite opacity measuring 2-5 mm in width; acceptable when limited to anatomic structures within the mediastinum [Fraser and Pare].
112095 Hiatus A gap or passage through an anatomical part or organ; especially: a gap through which another part or organ passes.
112096 Rib Scalene Tubercle A small rounded elevation or eminence on the first rib for the attachment of the scalenus anterior.
112097 Vertebral Intervertebral Notch A groove that serves for the transmission of the vertebral artery.
112098 Subscapular Fossa The concave depression of the anterior surface of the scapula.
112099 Scapular Spine A sloping ridge dividing the dorsal surface of the scapula into the supraspinatous fossa (above), and the infraspinatous fossa (below).
112100 Scapular Supraspinatus Fossa The portion of the dorsal surface of the scapula above the scapular spine.
112101 Scapular Infraspinatus Fossa The portion of the dorsal surface of the scapula below the scapular spine.
112102 Aortic knob The portion of the aortic arch that defines the transition between its ascending and descending limbs.
112103 Arch of the Azygos vein Section of Azygos vein near the fourth thoracic vertebra, where it arches forward over the root of the right lung, and ends in the superior vena cava, just before that vessel pierces the pericardium.
112104 Air-fluid level A local collection of gas and liquid that, when traversed by a horizontal X-Ray beam, creates a shadow characterized by a sharp horizontal interface between gas density above and liquid density below [Fraser and Pare].
112105 Corona radiata A circumferential pattern of fine linear spicules, approximately 5 mm long, extending outward from the margin of a solitary pulmonary nodule through a zone of relative lucency [Fraser and Pare].
112106 Honeycomb pattern A number of closely approximated ring shadows representing air spaces 5-10 mm in diameter with walls 2-3 mm thick that resemble a true honeycomb; implies "end-stage" lung [Fraser and Pare].
112107 Fleischner's line(s) A straight, curved, or irregular linear opacity that is visible in multiple projections; usually situated in the lower half of the lung; vary markedly in length and width [Fraser and Pare].
112108 Intralobular lines Fine linear opacities present in a lobule when the intralobular interstitium is thickened. When numerous, they may appear as a fine reticular pattern [Fraser and Pare].
112109 Kerley A line Essentially straight linear opacity 2-6 cm in length and 1-3 mm in width, usually in an upper lung zone [Fraser and Pare].
112110 Kerley B line A straight linear opacity 1.5-2 cm in length and 1-2 mm in width, usually at the lung base [Fraser and Pare].
112111 Kerley C lines A group of branching, linear opacities producing the appearing of a fine net, at the lung base [Fraser and Pare].
112112 Parenchymal band Elongated opacity, usually several millimeters wide and up to about 5 cm long, often extending to the pleura, which may be thickened and retracted at the site of contact [Fraser and Pare].
112113 Reticular pattern A collection of innumerable small linear opacities that together produce an appearance resembling a net [Fraser and Pare].
112114 Septal line(s) Usually used in the plural, a generic term for linear opacities of varied distribution produced when the interstitium between pulmonary lobules is thickened [Fraser and Pare].
112115 Subpleural line A thin curvilinear opacity, a few millimeters or less in thickness, usually less than 1 cm from the pleural surface and paralleling the pleura [Fraser and Pare].
112116 Tramline shadow Parallel or slightly convergent linear opacities that suggest the planar projection of tubular structures and that correspond in location and orientation to elements of the bronchial tree [Fraser and Pare].
112117 Tubular shadow Paired, parallel, or slightly convergent linear opacities presumed to represent the walls of a tubular structure seen en face; used if the anatomic nature of a shadow is obscure [Fraser and Pare].
112118 Density The opacity of a radiographic shadow to visible light; film blackening; the term should never be used to mean an "opacity" or "radiopacity" [Fraser and Pare].
112119 Dependent opacity Subpleural increased attenuation in dependent lung. The increased attenuation disappears when the region of lung is nondependent; a.k.a. dependent increased attenuation [Fraser and Pare].
112120 Ground glass opacity Hazy increased attenuation of lung, but with preservation of bronchial and vascular margins; caused by partial filling of air spaces, interstitial thickening, partial collapse of alveoli, normal expiration, or increased capillary blood volume [Fraser and Pare].
112121 Infiltrate Any ill-defined opacity in the lung [Fraser and Pare].
112122 Micronodule Discrete, small, round, focal opacity of at least soft tissue attenuation and with a diameter no greater than 7 mm [Fraser and Pare].
112123 Phantom tumor (pseudotumor) A shadow produced by a local collection of fluid in one of the interlobar fissures, usually elliptic in one radiographic projection and rounded in the other, resembling a tumor [Fraser and Pare].
112124 Shadow Any perceptible discontinuity in film blackening attributed to the attenuation of the X-Ray beam by a specific anatomic absorber or lesion on or within the body of the patient; to be employed only when more specific identification is not possible [Fraser and Pare].
112125 Small irregular opacities Term used to define a reticular pattern specific to pneumoconioses [Fraser and Pare].
112126 Small rounded opacities Term used to define a nodular pattern specific to pneumoconioses [Fraser and Pare].
112127 Tree-in-bud sign Nodular dilation of centrilobular branching structures that resembles a budding tree and represents exudative bronchiolar dilation [Fraser and Pare].
112128 Granular pattern Any extended, finely granular pattern of pulmonary opacity within which normal anatomic details are partly obscured [Fraser and Pare].
112129 Miliary pattern A collection of tiny discrete opacities in the lungs, each measuring 2 mm or less in diameter, generally uniform in size and widespread in distribution [Fraser and Pare].
112130 Mosaic pattern Generalized pattern of relatively well defined areas in the lung having different X-Ray attenuations due to a longstanding underlyingpulmonary disease.
112131 Extremely small A qualitative descriptor of a size that is dramatically less than typical.
112132 Very small A qualitative descriptor of a size that is considerably less than typical.
112133 Too small A qualitative descriptor of a size that is so small as to be abnormal versus expected size.
112134 Elliptic Shaped like an ellipse (oval).
112135 Lobulated A border shape that is made up of, provided with, or divided into lobules (small lobes, curved or rounded projections or divisions).
112136 Spiculated Radially orientated border shape.
112137 Sharply defined The border of a shadow (opacity) is sharply defined [Fraser and Pare].
112138 Distinctly defined The border of a shadow (opacity) is distinctly defined [Fraser and Pare].
112139 Well demarcated The border of a shadow (opacity) is well distinct from adjacent structures [Fraser and Pare].
112140 Sharply demarcated The border of a shadow (opacity) is sharply distinct from adjacent structures [Fraser and Pare].
112141 Poorly demarcated The border of a shadow (opacity) is poorly distinct from adjacent structures [Fraser and Pare].
112142 Circumscribed A shadow (opacity) possessing a complete or nearly complete visible border [Fraser and Pare].
112143 Air Inspired atmospheric gas. The word is sometimes used to describe gas within the body regardless of its composition or site [Fraser and Pare].
112144 Soft tissue Material having X-Ray attenuation properties similar to muscle.
112145 Calcium Material having X-Ray attenuation properties similar to calcium, a silver-white bivalent metallic element occurring in plants and animals.
112146 Acinar A pulmonary opacity 4-8 mm in diameter, presumed to represent anatomic acinus, or a collection of opacities in the lung, each measuring 4-8 mm in diameter, and together producing an extended, homogeneous shadow [Fraser and Pare].
112147 Air space The gas-containing portion of the lung parenchyma, including the acini and excluding the interstitium [Fraser and Pare].
112148 Fibronodular Sharply defined, approximately circular opacities occurring singly or in clusters, usually in the upper lobes [Fraser and Pare].
112149 Fluffy A shadow (opacity) that is ill-defined, lacking clear-cut margins [Fraser and Pare].
112150 Linear A shadow resembling a line; any elongated opacity of approximately uniform width [Fraser and Pare].
112151 Profusion The number of small opacities per unit area or zone of lung. In the International Labor Organization (ILO) classification of radiographs of the pneumoconioses, the qualifiers 0 through 3 subdivide the profusion into 4 categories. The profusion categories may be further subdivided by employing a 12-point scale [Fraser and Pare].
112152 Silhouette sign The effacement of an anatomic soft tissue border by either a normal anatomic structure or a pathologic state such as airlessness of adjacent lung or accumulation of fluid in the contiguous pleural space; useful in detecting and localizing an opacity along the axis of the X-Ray beam [Fraser and Pare].
112153 Subpleural Situated or occurring between the pleura and the body wall.
112154 Bat's wing distribution Spatial arrangement of opacities that bears vague resemblance to the shape of a bat in flight; bilaterally symmetric [Fraser and Pare].
112155 Butterfly distribution Spatial arrangement of opacities that bears vague resemblance to the shape of a butterfly in flight; bilaterally symmetric [Fraser and Pare].
112156 Centrilobular Referring to the region of the bronchioloarteriolar core of a secondary pulmonary lobule [Fraser and Pare].
112157 Coalescent The joining together of a number of opacities into a single opacity [Fraser and Pare].
112158 Lobar Of or relating to a lobe (a curved or rounded projection or division).
112159 Hyper-acute Extremely or excessively acute, as a qualitative measure of severity.
112160 Homogeneous Of uniform opacity or texture throughout [Fraser and Pare].
112161 Inhomogeneous Lack of homogeneity in opacity or texture.
112162 Target Discrete opacity centrally within a larger opacity, as a calcification descriptor.
112163 Fibrocalcific Pertaining to sharply defined, linear, and/or nodular opacities containing calcification(s) [Fraser and Pare].
112164 Flocculent Calcifications made up of loosely aggregated particles, resembling wool.
112165 Difference in border shape A change in the shape formed by the boundary or edges of a finding or feature.
112166 Difference in border definition A change in the clarity of the boundary or edges of a finding or feature.
112167 Difference in distribution A change in the extent of spreading of a finding or feature.
112168 Difference in site involvement A change in the part(s) of the anatomy affected or encompassed by a finding or feature.
112169 Difference in Type of Content A change in the matter or substance within a finding or feature.
112170 Difference in Texture A change in the surface or consistency of a finding or feature.
112171 Fiducial mark A location in image space, which may or may not correspond to an anatomical reference, which is often used for registering data.
112172 Portacath Connected to an injection chamber placed under the skin in the upper part of the chest. When it is necessary to inject some drug, a specific needle is put in the chamber through the skin and a silicon membrane. The advantage of a portacath is that it may be left in place several months contrarily of "classical" catheters.
112173 Chest tube A tube inserted into the chest wall from outside the body, for drainage. Sometimes used for collapsed lung. Usually connected to a receptor placed lower than the insertion site.
112174 Central line A tube placed into the subclavian vein to deliver medication directly into the venous system.
112175 Kidney stent A stent is a tube inserted into another tube. Kidney stent is a tube that is inserted into the kidney, ureter, and bladder, to help drain urine. Usually inserted through a scoping device presented through the urethra.
112176 Pancreatic stent A stent is a tube inserted into another tube. Pancreatic stent is inserted through the common bile duct to the pancreatic duct, to drain bile.
112177 Nipple ring A non-lesion object that appears to be a circular band, attached to the body via pierced nipple.
112178 Coin A non-lesion object that appears to be a flat round piece of metal.
112179 Minimum Attenuation Coefficient The least quantity assignable, admissible, or possible; the least of a set of X-Ray attenuation coefficients.
112180 Maximum Attenuation Coefficient The greatest quantity or value attainable or attained; the largest of a set of X-Ray attenuation coefficients.
112181 Mean Attenuation Coefficient The value that is computed by dividing the sum of a set of X-Ray attenuation coefficients by the number of values .
112182 Median Attenuation Coefficient The value in an ordered set of X-Ray attenuation coefficients, below and above which there is an equal number of values.
112183 Standard Deviation of Attenuation Coefficient For a set of X-Ray attenuation coefficients: 1) a measure of the dispersion of a frequency distribution that is the square root of the arithmetic mean of the squares of the deviation of each of the class frequencies from the arithmetic mean of the frequency distribution; 2) a parameter that indicates the way in which a probability function or a probability density function is centered around its mean and that is equal to the square root of the moment in which the deviation from the mean is squared.
112184 Performance of Pediatric and Adult Thoracic CT American College of Radiology. ACR Standard for the Performance of Pediatric and Adult Thoracic Computed Tomography (CT). In: Standards. Reston, Va: 2001:103-107.
112185 Performance of CT for Detection of Pulmonary Embolism in Adults American College of Radiology. ACR Standard for the Performance of Computed Tomography for the Detection of Pulmonary Embolism in Adults. In: Standards. Reston, Va: 2001:109-113.
112186 Performance of High-Resolution CT of the Lungs in Adults American College of Radiology. ACR Standard for the Performance of High-Resolution Computed Tomography (HRCT) of the Lungs in Adults. In: Standards. Reston, Va: 2001:115-118.
112187 Unspecified method of calculation The method of calculation of a measurement or other type of numeric value is not specified.
112188 Two-dimensional method The calculation method was performed in two-dimensional space.
112189 Three-dimensional method The calculation method was performed in three-dimensional space.
112191 Breast tissue density The relative density of parenchymal tissue as a proportion of breast volume.
112192 Volume of parenchymal tissue The volume of parenchymal tissue.
112193 Volume of breast The volume of the breast.
112194 Mass of parenchymal tissue The mass of parenchymal tissue.
112195 Mass of breast The mass of the breast.
112196 Area of Vascular Calcification A measured or calculated area of vascular calcification.
112197 Volume of Vascular Calcification A measured or calculated volume of vascular calcification.
112198 Percentage of Vascular Calcification A measured or calculated percentage of vascular calcification.
112199 Mass of Vascular Calcification A measured or calculated mass of vascular calcification.
112200 Average calcification distance in a calcification cluster The average nearest neighbor distance of all individual microcalcifications in a cluster.
112201 Standard deviation distance of calcifications in a cluster The standard deviation of nearest neighbor distance of all individual microcalcifications in a cluster.
112220 Colon CAD Report A structured report containing the results of computer-aided detection or diagnosis applied to colon imaging and associated clinical information.
112222 Colon Overall Assessment Overall interpretation of the colon using C-RADS categorization system.
112224 Image Set Properties Characteristics of a set of images.
112225 Slice Thickness Nominal slice thickness, in mm.
112226 Spacing between slices Distance between contiguous images, measured from the center-to-center of each image.
112227 Frame of Reference UID Uniquely identifies groups of composite instances that have the same coordinate system that conveys spatial and/or temporal information.
112228 Recumbent Patient Position with respect to gravity Patient orientation with respect to downward direction (gravity).
112229 Identifying Segment Distinguishes a part of a segmentation.
112232 Polyp stalk width The diameter of a polyp stalk measured perpendicular to the axis of the stalk.
112233 Distance from anus The length of the path following the centerline of the colon from the anus to the area of interest.
112238 Anatomic non-colon A location in the body that is outside the colon.
112240 C0 - Inadequate Study/Awaiting Prior Comparisons An inadequate study or a study that is awaiting prior comparisons. The study may have inadequate preparation and cannot exclude lesions greater than or equal to ten millimeters owing to presence of fluid or feces. The study may have inadequate insufflation where one or more colonic segments collapsed on both views. Based on "CT Colonography Reporting and Data System: A Consensus Proposal", Radiology, July 2005; 236:3-9.
112241 C1 - Normal Colon or Benign Lesion The study has a normal colon or benign lesion, with the recommendation to continue routine screening. The study has no visible abnormalities of the colon. The study has no polyps greater than six millimeters. The study may have lipoma, inverted diverticulum, or nonneoplastic findings, such as colonic diverticula. Based on "CT Colonography Reporting and Data System: A Consensus Proposal", Radiology, July 2005; 236:3-9.
112242 C2 - Intermediate Polyp or Indeterminate Finding The study has an intermediate polyp or indeterminate finding and surveillance or colonoscopy is recommended. There may be intermediate polyps between six and nine millimeters and there are less than three in number. The study may have an intermediate finding and cannot exclude a polyp that is greater than or equal to six millimeters in a technically adequate study. Based on "CT Colonography Reporting and Data System: A Consensus Proposal", Radiology, July 2005; 236:3-9.
112243 C3 - Polyp, Possibly Advanced Adenoma The study has a polyp, possibly advanced adenoma, and a follow-up colonoscopy is recommended. The study has a polyp greater than or equal to ten millimeters or the study has three or more polyps that are each between six to nine millimeters. Based on "CT Colonography Reporting and Data System: A Consensus Proposal", Radiology, July 2005; 236:3-9.
112244 C4 - Colonic Mass, Likely Malignant The study has a colonic mass, likely malignant, and surgical consultation is recommended. The lesion compromises bowel lumen and demonstrates extracolonic invasion. Based on "CT Colonography Reporting and Data System: A Consensus Proposal", Radiology, July 2005; 236:3-9.
112248 ACR Guideline, Performance of Adult CT Colonography American College of Radiology Practice Guideline for the Performance of Computed Tomography (CT) Colonography in Adults. In: Practice Guidelines and Technical Standards.Reston, Va: American College of Radiology;2006:371-376.
112249 ACR Standard, CT medical physics performance monitoring American College of Radiology Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment. In: Practice Guidelines and Technical Standards.Reston, Va: American College of Radiology;2006:945-948.
112300 AP+45 View Orientation Modifier indicates that the view orientation of the imaging plane is rotated +45° along the cranial-caudal axis.
112301 AP-45 View Orientation Modifier indicates that the view orientation of the imaging plane is rotated -45° along the cranial-caudal axis.
112302 Anatomical axis of femur The axis following the shaft of the femur.
112303 Acetabular Center of Rotation Center of Rotation of the natural Acetabulum.
112304 Femur Head Center of Rotation Center of Rotation of the natural femur head.
112305 Acetabular Cup Shell Prosthetic component implanted into the acetabulum. Provides hold for the insert that is mounted inside the cup.
112306 Acetabular Cup Insert Prosthetic pelvic joint component. Inserted into the cup, takes in the femoral head replacement.
112307 Acetabular Cup Monoblock Prosthetic pelvic joint cup including insert.
112308 Femoral Head Ball Component Component for Femoral Head Prosthesis where the conic intake for the stem neck can be exchanged.Combined with a Femoral Head Cone Taper Component.
112309 Femoral Head Cone Taper Component Exchangeable neck intake for composite femoral head prosthesis.Combined with a Femoral Head Ball Component.
112310 Femoral Stem Prosthesis Implanted into the femoral bone to provide force transmission between joint replacement and bone. On the proximal end a conic neck holds the femoral head replacement.
112311 Femoral Stem Distal Component Distal half of a modular stem prosthesis system.Combined with a Stem Proximal Component.
112312 Femoral Stem Proximal Component Proximal half of a modular stem prosthesis system.Combined with a Stem Distal Component.
112313 Femoral Stem Component Stem prosthetic component with a modular insert for an exchangeable neck component.Combined with a Neck Component.
112314 Neck Component Prosthetic Neck to be combined with a Stem Component.
112315 Monoblock Stem Prosthetic Stem and Femoral Head in one piece.
112316 Prosthetic Shaft Augment A proximal attachment to the shaft used to compensate for bone deficiencies or bone loss.
112317 Femoral Head Resurfacing Component Artificial femur head surface needed for the partial replacement of the femoral head where only the surface is replaced.
112318 Pinning Fixation using a pin.
112319 Sewing Fixation sewing several objects together.
112320 Bolting Fixation using a bolt.
112321 Wedging Fixation due to forcing an object into a narrow space.
112325 Distal Centralizer Attachment to the distal end of a cemented stem assuring that the stem is in a central position inside the drilled femoral canal before cementation.
112340 Generic 2D Planning Planning by an unspecified 2D method.
112341 Generic 3D Planning Planning by an unspecified 3D method.
112342 Generic Planning for Hip Replacement Planning of a Hip Replacement, by an unspecified method.
112343 Generic Planning for Knee Replacement Planning of Knee Replacement, by an unspecified method.
112344 Müller Method Planning for Hip Replacement Planning of Hip Replacement according to the procedure of M. E. Müller [Eggli et. al.1998].
112345 Implantation Plan A Report containing the results of an Implantation Planning Activity.
112346 Selected Implant Component A selection of one Implant Component.
112347 Component ID Identification ID of an Implant Component.
112348 Implant Template An implant template describing the properties (2D/3D geometry and other data) of one Implant Component.
112350 Component Connection A connection of two Connected Implantation Plan Components.
112351 Mating Feature Set ID ID of a Mating Feature Set in an Implant Component.
112352 Mating Feature ID ID of the Mating Feature in a Mating Feature Set in an Implant Component.
112353 Spatial Registration The Spatial Registration of one or more Implant Components.
112354 Patient Image Patient Images used for an implantation planning activity.
112355 Assembly A collection of Component Connections of Implant Components.
112356 User Selected Fiducial Fiducials that are selected by the user and may or may not belong to anatomical landmarks.
112357 Derived Fiducial Fiducials that represent geometric characteristics, such as center of rotation, and are derived from other fiducials.
112358 Information used for planning All parameters and data that were used for the planning activity.
112359 Supporting Information A description of the plan as encapsulated PDF SOP Instance.
112360 Implant Component List A list of all Implant Components selected for an implantation.
112361 Patient Data Used During Planning Reference to objects containing patient data that is used for planning.
112362 Degrees of Freedom Specification A specification of the values from one or more Degrees of Freedom.
112363 Degree of Freedom ID ID of one Degree of Freedom.
112364 Related Patient Data Not Used During Planning Reference to objects containing patient data that were not used for planning but are somehow related.
112365 Related Implantation Reports Implantation Reports that are somehow related.
112366 Implant Assembly Template Implant Assembly Template.
112367 Planning Information for Intraoperative Usage Information that is intended to be used intra-operatively.
112368 Implantation Patient Positioning Position of the patient on the operating room table.
112369 Fiducial Intent Intended use of the fiducial.
112370 Component Type Type of an Implant Component.
112371 Manufacturer Implant Template Implant Template released by the Manufacturer.
112372 Derived Planning Images Images that are created by a planning application.
112373 Other Derived Planning Data Data that is created by a planning application.
112374 Connected Implantation Plan Component One Implant Component that is connected to another Implant Component.
112375 Planning Method The method used for planning.
112376 Degree of Freedom Exact Translational Value Defines the exact value that was planned for translation.
112377 Degree of Freedom Minimum Translational Value Defines the minimum value that was planned for translation.
112378 Degree of Freedom Maximum Translational Value Defines the maximum value that was planned for translation.
112379 Degree of Freedom Exact Rotational Translation Value Defines the exact value that was planned for rotation.
112380 Degree of Freedom Minimum Rotational Value Defines the minimum value that was planned for rotation.
112381 Degree of Freedom Maximum Rotational Value Defines the maximum value that was planned for rotation.
112700 Peri-operative Photographic Imaging Procedure step protocol for photographic imaging of surgical procedures, including photography of specimens collected.
112701 Gross Specimen Imaging Procedure step protocol for imaging gross specimens, typically with a photographic camera (modality XC), and planning further dissection.
112702 Slide Microscopy Procedure step protocol for imaging slide specimens.
112703 Whole Slide Imaging Procedure step protocol for imaging slide specimens using a whole slide scanner.
112704 WSI 20X RGB Procedure step protocol for imaging slide specimens using a whole slide scanner with a 20X nominal objective lens, in full color, with a single imaging focal plane across the image.
112705 WSI 40X RGB Procedure step protocol for imaging slide specimens using a whole slide scanner with a 40X nominal objective lens, in full color, with a single imaging focal plane across the image.
112706 Illumination Method Technique of illuminating specimen.
112707 Number of focal planes Number of focal planes for a microscopy image acquisition.
112708 Focal plane Z offset Nominal distance above a reference plane (typically a slide glass substrate top surface) of the focal plane.
112709 Magnification selection Microscope magnification based on nominal objective lens power.
112710 Illumination wavelength Nominal center wavelength for an imaging spectral band.
112711 Illumination spectral band Name (coded) for an imaging spectral band.
112712 Optical filter type Type of filter inserted into the optical imaging path.
112713 Tissue selection method Technique for identifying tissue to be imaged versus area of slide not to be imaged.
112714 Multiple planes Imaging performed at multiple imaging (focal) planes.
112715 5X Nominal 5 power objective lens, resulting in a digital image at approximately 2 um/pixel spacing.
112716 10X Nominal 10 power objective lens, resulting in a digital image at approximately 1 um/pixel spacing.
112717 20X Nominal 20 power microscope objective lens, resulting in a digital image at approximately 0.5 um/pixel spacing.
112718 40X Nominal 40 power microscope objective lens, with a combined condenser and objective lens numerical aperture of approximately 1.3, resulting in a digital image at approximately 0.25 um/pixel spacing.
112719 Nominal empty tile suppression Equipment-specific nominal or default method for identifying tiles without tissue imaged for suppression from inclusion in image object.
112720 High threshold empty tile suppression Equipment-specific high threshold method for identifying tiles without tissue imaged for suppression from inclusion in image object.
112721 No empty tile suppression Tiles without tissue imaged are not suppressed from inclusion in image object.
113000 Of Interest Of Interest.
113001 Rejected for Quality Reasons Rejected for Quality Reasons.
113002 For Referring Provider For Referring Provider.
113003 For Surgery For Surgery.
113004 For Teaching For Teaching.
113005 For Conference For Conference.
113006 For Therapy For Therapy.
113007 For Patient For Patient.
113008 For Peer Review For Peer Review.
113009 For Research For Research.
113010 Quality Issue Quality Issue.
113011 Document Title Modifier Document Title Modifier.
113012 Key Object Description Key Object Description.
113013 Best In Set A selection that represents the "best" chosen from a larger set of items.
113014 Study A study is a collection of one or more series of medical images, presentation states, and/or SR documents that are logically related for the purpose of diagnosing a patient. A study may include composite instances that are created by a single modality, multiple modalities or by multiple devices of the same modality. [From ]
113015 Series A distinct logical set used to group composite instances. All instances within a Series are of the same modality, in the same Frame of Reference (if any), and created by the same equipment. [See ]
113016 Performed Procedure Step An arbitrarily defined unit of service that has actually been performed (not just scheduled). [From ]
113017 Stage-View An image or set of images illustrating a specific stage (phase in a stress echo study protocol) and view (combination of the transducer position and orientation at the time of image acquisition).
113018 For Printing For Printing.
113020 For Report Attachment Selection of information objects for attachment to the clinical report of the Current Requested Procedure.
113021 For Litigation List of objects that are related to litigation and should be specially handled.
113022 Collection of Presentation States This Key Object Selection Document references Presentation State instances that are related, which may or may not share a value of Presentation Display Collection UID (0070,1101) or Presentation Sequence Collection UID (0070,1102).
113026 Double exposure Double exposure.
113030 Manifest A list of objects that have been exported out of one organizational domain into another domain. Typically, the first domain has no direct control over what the second domain will do with the objects.
113031 Signed Manifest A signed list of objects that have been exported out of one organizational domain into another domain, referenced securely with either Digital Signatures or MACs. Typically, the first domain has no direct control over what the second domain will do with the objects.
113032 Complete Study Content The list of objects that constitute a study at the time that the list was created.
113033 Signed Complete Study Content The signed list of objects that constitute a study at the time that the list was created, referenced securely with either Digital Signatures or MACs.
113034 Complete Acquisition Content The list of objects that were generated in a single procedure step.
113035 Signed Complete Acquisition Content The signed list of objects that were generated in a single procedure step, referenced securely with either Digital Signatures or MACs.
113036 Group of Frames for Display A list of frames or single-frame or entire multi-frame instances that together constitute a set for some purpose, such as might be displayed together in the same viewport, as distinct from another set that might be displayed in a separate viewport.
113037 Rejected for Patient Safety Reasons List of objects whose use is potentially harmful to the patient.
113038 Incorrect Modality Worklist Entry List of objects that were acquired using an incorrect modality worklist entry, and that should not be used, since they may be incorrectly identified.
113039 Data Retention Policy Expired List of objects that have expired according to a defined data retention policy.
113040 Lossy Compression Lossy compression has been applied to an image.
113041 Apparent Diffusion Coefficient Values are derived by calculation of the apparent diffusion coefficient. This concept may be used for the diffusion coefficient of various different models, e.g., mono-exponential (ADCm), kurtosis (ADCk), stretched-exponential (ADCs).The "apparent" appellation is because the diffusion images from which the ADC is computed may also be affected by T2 contrast (T2 "shine-through"), so this concept is distinguished from a "pure" diffusion coefficient that is not so affected.
113042 Pixel by pixel addition Values are derived by the pixel by pixel addition of two images.
113043 Diffusion weighted Values are derived by calculation of the diffusion weighting.
113044 Diffusion Anisotropy Values are derived by calculation of the diffusion anisotropy.
113045 Diffusion Attenuated Values are derived by calculation of the diffusion attenuation.
113046 Pixel by pixel division Values are derived by the pixel by pixel division of two images.
113047 Pixel by pixel mask Values are derived by the pixel by pixel masking of one image by another.
113048 Pixel by pixel Maximum Values are derived by calculating the pixel by pixel maximum of two or more images.
113049 Pixel by pixel mean Values are derived by calculating the pixel by pixel mean of two or more images.
113050 Metabolite Maps from spectroscopy data Values are derived by calculating from spectroscopy data pixel values localized in two dimensional space based on the concentration of specific metabolites (i.e, at specific frequencies).
113051 Pixel by pixel Minimum Values are derived by calculating the pixel by pixel minimum of two or more images.
113052 Mean Transit Time The time required for blood to pass through a region of tissue.
113053 Pixel by pixel multiplication Values are derived by the pixel by pixel multiplication of two images.
113054 Negative Enhancement Integral The area described by the baseline and the signal loss due to passage of contrast bolus in tissue in a perfusion experiment. Abbreviated NEI or N1.
113055 Regional Cerebral Blood Flow The absolute flow rate of blood perfusing a region of the brain as volume per mass per unit of time. The mass divisor may be approximated by a measurement of volume assuming a tissue density of 1.
113056 Regional Cerebral Blood Volume The absolute volume of blood perfusing a region of brain as volume per mass. The mass divisor may be approximated by a measurement of volume assuming a tissue density of 1.
113057 R-Coefficient Correlation Coefficient, r.
113058 Proton Density Values are derived by calculating proton density values.
113059 Signal Change The relative change in signal.
113060 Signal to Noise The ratio of the desired signal to the level of noise.
113061 Standard Deviation Values are derived by calculating the standard deviation of two or more images.
113062 Pixel by pixel subtraction Values are derived by the pixel by pixel subtraction of two images.
113063 T1 The time constant for the decay of longitiudinal magnetization caused by spin-lattice relaxation. The inverse of the longitudinal relaxation rate constant, i.e., T1 = 1/R1.
113064 T2* The time constant for the decay of transverse magnetization caused by a combination of spin-spin relaxation and magnetic field inhomogeneity. The inverse of the transverse relaxation rate constant, i.e., T2* = 1/R2*.
113065 T2 The time constant for the decay of transverse magnetization caused by spin-spin relaxation. The inverse of the transverse relaxation rate constant, i.e., T2 = 1/R2.
113066 Time Course of Signal The time course of signal.
113067 Temperature encoded Values are derived by calculating values based on temperature encoding.
113068 Student's T-Test Values are derived by calculating the value of the Student's T-Test statistic from multiple image samples.
113069 Time To Peak The time from the start of the contrast agent injection to the maximum enhancement value.
113070 Velocity encoded Values are derived by calculating values based on velocity encoded.
113071 Z-Score Values are derived by calculating the value of the Z-Score statistic from multiple image samples.
113072 Multiplanar reformatting Values are derived by reformatting in a flat plane other than that originally acquired.
113073 Curved multiplanar reformatting Values are derived by reformatting in a curve plane other than that originally acquired.
113074 Volume rendering Values are derived by volume rendering of acquired data.
113075 Surface rendering Values are derived by surface rendering of acquired data.
113076 Segmentation Values are derived by segmentation (classification into tissue types) of acquired data.
113077 Volume editing Values are derived by selectively editing acquired data (removing values from the volume), such as in order to remove obscuring structures or noise.
113078 Maximum intensity projection Values are derived by maximum intensity projection of acquired data.
113079 Minimum intensity projection Values are derived by minimum intensity projection of acquired data.
113080 Glutamate and glutamine For single-proton MR spectroscopy, the resonance peak corresponding to glutamate and glutamine.
113081 Choline/Creatine Ratio For single-proton MR spectroscopy, the ratio between the Choline and Creatine resonance peaks.
113082 N-acetylaspartate /Creatine Ratio For single-proton MR spectroscopy, the ratio between the N-acetylaspartate and Creatine resonance peaks.
113083 N-acetylaspartate /Choline Ratio For single-proton MR spectroscopy, the ratio between the N-acetylaspartate and Choline resonance peaks.
113084 Tmax The time delay to the maximum of the residue function after deconvolution.Shih LC, Saver JL, Alger JR, Starkman S, Leary MC, Vinuela F, et al. Perfusion-Weighted Magnetic Resonance Imaging Thresholds Identifying Core, Irreversibly Infarcted Tissue. Stroke. 2003 Jun 1;34(6):1425-30. doi:10.1161/01.STR.0000072998.70087.E9. Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magnetic Resonance in Medicine. 1996;36(5):715-25. doi:10.1002/mrm.1910360510.
113085 Spatial resampling Values are derived by spatial resampling of acquired data.
113086 Edge enhancement Values are derived by edge enhancement.
113087 Smoothing Values are derived by smoothing.
113088 Gaussian blur Values are derived by Gaussian blurring.
113089 Unsharp mask Values are derived by unsharp masking.
113090 Image stitching Values are derived by stitching two or more images together.
113091 Spatially-related frames extracted from the volume Spatially-related frames in this image are representative frames from the referenced 3D volume data.
113092 Temporally-related frames extracted from the set of volumes Temporally-related frames in this image are representative frames from the referenced 3D volume data.
113093 Polar to Rectangular Scan Conversion Conversion of a polar coordinate image to rectangular (Cartesian) coordinate image.
113094 Creatine and Choline For single-proton MR spectroscopy, the resonance peak corresponding to creatine and choline.
113095 Lipid and Lactate For single-proton MR spectroscopy, the resonance peak corresponding to lipid and lactate.
113096 Creatine+Choline/ Citrate Ratio For single-proton MR spectroscopy, the ratio between the Choline and Creatine resonance peak and the Citrate resonance peak.
113097 Multi-energy proportional weighting Image pixels created through proportional weighting of multiple acquisitions at distinct X-Ray energies.
113098 Magnetization Transfer Ratio Magnetization Transfer Ratio (MTR) is the ratio of magnetization transfer, Mo - Ms/Mo, where Ms represents the magnitude of signal of tissues with the saturation pulse used to saturate macromolecular protons on, and Mo is the magnitude of signal without saturation.See Dousset V, Grossman RI, Ramer KN, Schnall MD, Young LH, Gonzalez-Scarano F, et al. Experimental allergic encephalomyelitis and multiple sclerosis: lesion characterization with magnetization transfer imaging. Radiology. 1992 Feb 1;182(2):483-91. http://dx.doi.org/10.1148/radiology.182.2.1732968
113100 Basic Application Confidentiality Profile De-identification using a profile defined in that requires removing all information related to the identity and demographic characteristics of the patient, any responsible parties or family members, any personnel involved in the procedure, the organizations involved in ordering or performing the procedure, additional information that could be used to match instances if given access to the originals, such as UIDs, dates and times, and Private Attributes, when that information is present in the non-Pixel Data Attributes, including graphics or overlays.
113101 Clean Pixel Data Option Additional de-identification according to an option defined in that requires any information burned in to the Pixel Data corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed.
113102 Clean Recognizable Visual Features Option Additional de-identification according to an option defined in that requires that sufficient removal or distortion of the Pixel Data shall be applied to prevent recognition of an individual from the instances themselves or a reconstruction of a set of instances.
113103 Clean Graphics Option Additional de-identification according to an option defined in that requires that any information encoded in graphics, text annotations or overlays corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed.
113104 Clean Structured Content Option Additional de-identification according to an option defined in that requires that any information encoded in SR Content Items or Acquisition Context Sequence Items corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed.
113105 Clean Descriptors Option Additional de-identification according to an option defined in that requires that any information that is embedded in text or string Attributes corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed.
113106 Retain Longitudinal Temporal Information Full Dates Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that any dates and times be retained,.
113107 Retain Longitudinal Temporal Information Modified Dates Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that any dates and times be modified in a manner that preserves temporal relationships.
113108 Retain Patient Characteristics Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that any physical characteristics of the patient, which are descriptive rather than identifying information per se, be retained.
113109 Retain Device Identity Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that any information that identifies a device be retained.
113110 Retain UIDs Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that UIDs be retained.
113111 Retain Safe Private Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that Private Attributes that are known not to contain identity information be retained.
113112 Retain Institution Identity Option Retention of information that would otherwise be removed during de-identification according to an option defined in that requires that any information that identifies an institution be retained.
113130 Predecessor containing group of imaging subjects Images used as the source for an image processing operation that extracts data for a single subject from an image containing data for multiple subjects (e.g., a group of animals imaged simultaneously).
113131 Extraction of individual subject from group An image processing operation that extracts data for a single subject from an image containing data for multiple subjects (e.g., a group of animals imaged simultaneously).
113132 Single subject selected from group A single subject that has been selected from amongst multiple subjects (e.g., a group of animals imaged simultaneously).
113201 Trace Sum of the diffusion tensor eigenvalues.I.e.: Tr = λ1+ λ2+ λ3, where λ1 ≥ λ2 ≥ λ3.Reference: Winston GP. The physical and biological basis of quantitative parameters derived from diffusion MRI. Quantitative Imaging in Medicine and Surgery. 2012;2(4) :254-265. doi:10.3978/j.issn.2223-4292.2012.12.05. ()
113202 Mean Diffusivity Average of the diffusion tensor eigenvalues in all directions.I.e.: MD = (λ1+ λ2+ λ3) /3Reference: Winston GP. The physical and biological basis of quantitative parameters derived from diffusion MRI. Quantitative Imaging in Medicine and Surgery. 2012;2(4) :254-265. doi:10.3978/j.issn.2223-4292.2012.12.05. ()
113203 Radial Diffusivity Average of the two non-principal (i.e., perpendicular) diffusion tensor eigenvalues(also known as transverse diffusivity, perpendicular diffusivity).I.e.: DR= (λ2+ λ3) /2Reference: Winston GP. The physical and biological basis of quantitative parameters derived from diffusion MRI. Quantitative Imaging in Medicine and Surgery. 2012;2(4) :254-265. doi:10.3978/j.issn.2223-4292.2012.12.05. ()
113204 Axial Diffusivity Diffusion tensor eigenvalue of the principal axis (also known as longitudinal diffusivity, parallel diffusivity).I.e.: DA = λ1Reference: Winston GP. The physical and biological basis of quantitative parameters derived from diffusion MRI. Quantitative Imaging in Medicine and Surgery. 2012;2(4) :254-265. doi:10.3978/j.issn.2223-4292.2012.12.05. ()
113205 Mean Kurtosis MK = diffusional kurtosis averaged over all gradient directionsReference: Tabesh A, Jensen JH, Ardekani BA, Helpern JA. Estimation of Tensors and Tensor-Derived Measures in Diffusional Kurtosis Imaging. Magnetic Resonance in Medicine. 2011;65(3) :823-836. doi:10.1002/mrm.22655. ()Reference: Liu C, Mang SC, Moseley ME. In VivoGeneralized Diffusion Tensor Imaging (GDTI) Using Higher-Order Tensors (HOT). Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 2010;63(1) :243-252. doi:10.1002/mrm.22192. ()
113206 Apparent Kurtosis Coefficient AKC = diffusional kurtosis in a given directionReference: Liu C, Mang SC, Moseley ME. In VivoGeneralized Diffusion Tensor Imaging (GDTI) Using Higher-Order Tensors (HOT). Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 2010;63(1) :243-252. doi:10.1002/mrm.22192. ()
113207 Radial Kurtosis KR = diffusional kurtosis perpendicular to the direction of the highest diffusion (also known as transverse kurtosis, perpendicular kurtosis)Reference: Tabesh A, Jensen JH, Ardekani BA, Helpern JA. Estimation of Tensors and Tensor-Derived Measures in Diffusional Kurtosis Imaging. Magnetic Resonance in Medicine. 2011;65(3) :823-836. doi:10.1002/mrm.22655. ()
113208 Axial Kurtosis KA = diffusional kurtosis in the direction of the highest diffusion (also known as longitudinal kurtosis, parallel kurtosis)Reference: Tabesh A, Jensen JH, Ardekani BA, Helpern JA. Estimation of Tensors and Tensor-Derived Measures in Diffusional Kurtosis Imaging. Magnetic Resonance in Medicine. 2011;65(3) :823-836. doi:10.1002/mrm.22655. ()
113209 Fractional Kurtosis Anisotropy FKA = fractional kurtosis of diffusion in tissuesReference: Liu C, Mang SC, Moseley ME. In VivoGeneralized Diffusion Tensor Imaging (GDTI) Using Higher-Order Tensors (HOT). Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine. 2010;63(1) :243-252. doi:10.1002/mrm.22192. ()
113211 Deterministic Tracking Algorithm Tracking based on local directionalityReference: Descoteaux M, Deriche R, Knösche TR, Anwander A. Deterministic and probabilistic tractography based on complex fibre orientation distributions. IEEE Trans Med Imaging.2009; 28(2) :269-86 ()
113212 Probabilistic Tracking Algorithm Tracking using local fiber orientation likelihood derive global connectivity likelihoodReference: Descoteaux M, Deriche R, Knösche TR, Anwander A. Deterministic and probabilistic tractography based on complex fibre orientation distributions. IEEE Trans Med Imaging.2009; 28(2) :269-86 ()
113213 Global Tracking Algorithm Tracking allfibers simultaneously, searching for a global optimum.Reference: Reisert M, Mader I, Anastasopoulos C, Weigel M, Schnell S, Kiselev V. Global fiber reconstruction becomes practical. NeuroImage. 2011 Jan 15;54(2) :955-62. ()
113214 FACT Fiber Assessment by Continuous TrackingReference: Mori S, Crain BJ, Chacko VP, van Zijl PC. Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging. Ann Neurol . 1999 Feb;45(2) :265-9 ()Reference: Descoteaux M, Deriche R, Knösche TR, Anwander A. Deterministic and probabilistic tractography based on complex fibre orientation distributions. IEEE Trans Med Imaging.2009; 28(2) :269-86 ()
113215 Streamline Streamline tracking techniques (STT)Reference: Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A. In vivo fiber tractography using DT-MRI data. Magn Reson Med. 2000 Oct;44(4) :625-32 ()
113216 TEND Tensor DeflectionReference: Lazar M, Weinstein DM, Tsuruda JS, Hasan KM, Arfanakis K, Meyerand ME, Badie B, Rowley HA, Haughton V, Field A, Alexander AL. White matter tractography using diffusion tensor deflection. Hum Brain Mapp.2003 Apr;18(4) :306-21. ()
113217 Bootstrap Tracking Algorithm Non-parametric estimation of fiber tracking dispersionReference: Lazar M, Alexander AL. Bootstrap white matter tractography (BOOT-TRAC). Neuroimage. 2005 Jan 15;24(2) :524-32. Epub 2004 Nov 24. ()Reference: Jones DK, Pierpaoli C. Confidence mapping in diffusion tensor magnetic resonance imaging tractography using a bootstrap approach. Magn Reson Med.2005 May;53(5) :1143-9. ()
113218 Euler Integration method, 1st orderReference: Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A. In vivo fiber tractography using DT-MRI data. Magn Reson Med. 2000 Oct;44(4) :625-32 ()Reference: Descoteaux M, Deriche R, Knösche TR, Anwander A. Deterministic and probabilistic tractography based on complex fibre orientation distributions. IEEE Trans Med Imaging.2009; 28(2) :269-86 ()
113219 Runge-Kutta Integration method, 2nd or 4th orderReference: Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A. In vivo fiber tractography using DT-MRI data. Magn Reson Med. 2000 Oct;44(4) :625-32 ()
113221 HARDI High Angular Resolution Diffusion ImagingReference: Tuch DS, Reese TG, Wiegell MR, Makris N, Belliveau JW, Wedeen VJ. High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity. Magn Reson Med.2002 Oct;48(4) :577-82. ()Reference: Descoteaux M, Deriche R, Knösche TR, Anwander A. Deterministic and probabilistic tractography based on complex fibre orientation distributions. IEEE Trans Med Imaging.2009; 28(2) :269-86 ()
113222 DKI Diffusion(al) Kurtosis ImagingReference: Jensen JH, Helpern JA, Ramani A, Lu H, Kaczynski K. Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging. Magn Reson Med. 2005 Jun;53(6) :1432-40. ()
113223 DTI Diffusion Tensor ImagingReference: Winston GP. The physical and biological basis of quantitative parameters derived from diffusion MRI. Quantitative Imaging in Medicine and Surgery. 2012;2(4) :254-265. doi:10.3978/j.issn.2223-4292.2012.12.05. ()
113224 DSI Diffusion Spectrum ImagingReference: Wedeen VJ, Wang RP, Schmahmann JD, Benner T, Tseng WY, Dai G, Pandya DN, Hagmann P, D'Arceuil H, de Crespigny AJ. Diffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibers. Neuroimage. 2008 Jul 15;41(4) :1267-77. doi:10.1016/j.neuroimage.2008.03.036. ()Reference: Hagmann P, Jonasson L, Maeder P, Thiran JP, Wedeen VJ, Meuli R. Understanding diffusion MR imaging techniques: from scalar diffusion-weighted imaging to diffusion tensor imaging and beyond. Radiographics.2006 Oct;26 Suppl 1:S205-23. ()
113225 LSDI Line Scan Diffusion Imaging sequenceReference: Gudbjartsson H, Maier SE, Mulkern RV, Mórocz IA, Patz S, Jolesz FA. Line scan diffusion imaging. Magn Reson Med.1996 Oct;36(4) :509-19. ()
113226 Single Shot EPI An Echo Planar Imaging sequence in which the entire range of phase encoding steps is acquired in one repetition.Reference: Turner R, Le Bihan D, Chesnick AS. Echo-planar imaging of diffusion and perfusion. Magn Reson Med.1991 Jun;19(2) :247-53. ()
113227 Multi Shot EPI An Echo Planar Imaging sequence in which separate parts of the range of phase encoding steps are acquired in multiple repetitions.Reference: Robson MD, Anderson AW, Gore JC. Diffusion-weighted multiple shot echo planar imaging of humans without navigation. Magn Reson Med.1997 Jul;38(1) :82-8. ()
113228 Parallel Imaging A imaging sequence that uses a subset of k-space data from an array of receiver coils, e.g., Sensitivity Encoding.Reference: Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med.1999 Nov;42(5) :952-62. ()Reference: Deshmane A, Gulani V, Griswold MA, Seiberlich N. Parallel MR imaging. J Magn Reson Imaging. 2012 Jul;36(1) :55-72. ()
113231 Single Tensor Modeling anisotropic diffusion in a volume with a tensor following a Gaussian distribution (six degrees of freedom)Reference: Basser PJ, Mattiello J, LeBihan D. Estimation of the effective self-diffusion tensor from the NMR spin echo. J Magn Reson B.1994 Mar;103(3) :247-54. ()Reference: Hagmann P1, Jonasson L, Maeder P, Thiran JP, Wedeen VJ, Meuli R. Understanding diffusion MR imaging techniques: from scalar diffusion-weighted imaging to diffusion tensor imaging and beyond. Radiographics.2006 Oct;26 Suppl 1:S205-23. ()
113232 Multi Tensor Modeling anisotropic diffusion in a volume by fitting of multiple tensorsReference: Ozarslan E, Mareci TH. Generalized diffusion tensor imaging and analytical relationships between diffusion tensor imaging and high angular resolution diffusion imaging. Magn Reson Med.2003 Nov;50(5) :955-65. ()Reference: Pasternak O, Assaf Y, Intrator N, Sochen N. Variational multiple-tensor fitting of fiber-ambiguous diffusion-weighted magnetic resonance imaging voxels. Magn Reson Imaging.2008 Oct;26(8) :1133-44. doi:10.1016/j.mri.2008.01.006. ()
113233 Model Free Reconstruction of anisotropic diffusion in a volume without imposing an underlying statistical model (data-driven approach)Reference: Wedeen VJ, Hagmann P, Tseng WY, Reese TG, Weisskoff RM. Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging. Magn Reson Med.2005 Dec;54(6) :1377-86. ()Reference: Hagmann P, Jonasson L, Maeder P, Thiran JP, Wedeen VJ, Meuli R. Understanding diffusion MR imaging techniques: from scalar diffusion-weighted imaging to diffusion tensor imaging and beyond. Radiographics.2006 Oct;26 Suppl 1:S205-23. ()
113234 CHARMED Composite Hindered and Restricted Model of DiffusionReference: Assaf Y, Basser PJ. Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain. Neuroimage.2005 Aug 1;27(1) :48-58. ()
113236 DOT Diffusion Orientation TransformReference: Ozarslan E, Shepherd TM, Vemuri BC, Blackband SJ, Mareci TH. Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT). Neuroimage. 2006 Jul 1;31(3) :1086-103. Epub 2006 Mar 20. ()
113237 PAS Persistent Angular StructureReference: Jansons KM, Alexander DC. Persistent Angular Structure: new insights from diffusion MRI data. Dummy version. Inf Process Med Imaging.2003 Jul;18:672-83. ()
113238 Spherical Deconvolution A method to estimate the distribution of fiber orientations by deconvolution of the diffusion-weighted signal attenuation measured over the surface of a sphere expressed as the convolution over the sphere of a response function.Reference: Tournier JD, Calamante F, Gadian DG, Connelly A. Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolution. NeuroImage. 2004 Nov;23(3) :1176-85. ()
113240 Source image diffusion b-value The diffusion sensitization factor (b value) used during acquisition of the source image used for a diffusion model.
113241 Model fitting method The method used to fit a set of data to a mathematical model.
113250 Mono-exponential diffusion model Mono-exponential (single compartment) Apparent Diffusion Coefficient (ADC) model.
113251 Bi-exponential (IVIM) diffusion model Bi-exponential intravoxel incoherent motion (IVIM) model.
113252 Kurtosis diffusion model .
113253 Gamma distribution model .
113254 Stretched exponential diffusion model .
113255 Truncated Gaussian diffusion model .
113260 Log of ratio of two samples Model fitting by using the log of the ratio of the two samples.
113261 Least squares fit of multiple samples Model fitting by least squares method from more than two samples.
113265 Levenberg-Marquardt Model fitting by Levenberg-Marquardt method.
113266 Trust-Region Model fitting by Trust-Region method.
113267 Fixed-Dp Model fitting by Fixed-Dp method.
113268 Segmented-Unconstrained Model fitting by Segmented-Unconstrained method.
113269 Segmented-Constrained Model fitting by Segmented-Constrained method.
113270 Bayesian-Probability Model fitting by Bayesian-Probability method.
... ... ...
113285 Voxelwise selection of b-value Diffusion modeling by voxelwise selection of b-values.
113288 Volume Ratio Coefficient reflecting the anisotropy of the tissues, derived from a diffusion weighted MR image. It represents the volume of an ellipsoid whose semimajor axes are the three eigenvalues of the diffusion tensor divided by the volume of a sphere whose radius is the mean diffusivity.
113289 Diffusion Coefficient The pure diffusion coefficient, i.e., one that is not affected by T2 contrast effects.
113290 Mono-exponential Apparent Diffusion Coefficient The diffusion coefficient of a mono-exponential diffusion model (ADCm).
113291 Slow Diffusion Coefficient The slow diffusion coefficient (Ds) of a bi-exponential intravoxel incoherent motion (IVIM) diffusion model.
113292 Fast Diffusion Coefficient The fast diffusion coefficient (Df) of a bi-exponential intravoxel incoherent motion (IVIM) diffusion model.
113293 Fast Diffusion Coefficient Fraction The fast diffusion fraction of a bi-exponential intravoxel incoherent motion (IVIM) diffusion model.
113294 Kurtosis Diffusion Coefficient The diffusion coefficient of a kurtosis diffusion model (ADCk).
113295 Gamma Distribution Scale Parameter The scale (theta) parameter of a gamma distribution diffusion model.
113296 Gamma Distribution Shape Parameter The shape (k) parameter of a gamma distribution diffusion model.
113297 Gamma Distribution Mode The mode (maximum value of probability density function) of a gamma distribution diffusion model. Computed as (k-1)*theta, for k >= 1.
113298 Distributed Diffusion Coefficient The distributed diffusion coefficient of a stretched-exponential diffusion model (ADCs).
113299 Anomalous Exponent Parameter The anomalous exponent (stretching, alpha) parameter of a stretched-exponential diffusion model. This describes the deviation of the signal attenuation from mono-exponential behavior
113500 Radiopharmaceutical Radiation Dose Report The procedure report is a Radiopharmaceutical Radiation Dose report
113502 Radiopharmaceutical Administration Information pertaining to the administration of a radiopharmaceutical
113503 Radiopharmaceutical Administration Event UID Unique identification of a single radiopharmaceutical administration event.
113505 Intravenous Extravasation Symptoms Initial signs or symptoms of extravasation
113506 Estimated Extravasation Activity The estimated percentage of administered activity lost at the injection site. The estimation includes extravasation, paravenous administration and leakage at the injection site.
113507 Administered activity The calculated activity at the Radiopharmaceutical Start Time when the radiopharmaceutical is administered to the patient. The residual activity (i.e., radiopharmaceutical not administered) , if measured, is reflected in the calculated value. The estimated extravasation is not reflected in the calculated value.
113508 Pre-Administration Measured Activity Radioactivity measurement of radiopharmaceutical before or during the administration.
113509 Post-Administration Measured Activity Radioactivity measurement of radiopharmaceutical after the administration.
113510 Drug Product Identifier Registered drug establishment code for product, coding scheme example is NDC or RxNorm
113511 Radiopharmaceutical Dispense Unit Identifier The human readable identification of the specific radiopharmaceutical dispensed quantity or dose ("dose" as unit of medication delivery, not radiation dose measure) to be administered to the patient.
113512 Radiopharmaceutical Lot Identifier Identifies the vial, batch or lot number from which the individual dispense radiopharmaceutical quantity (dose) is produced. The Radiopharmaceutical Dispense Unit Identifier records the identification for each individual dose.
113513 Reagent Vial Identifier Identifies the lot or unit serial number for the reagent component for the radiopharmaceutical.
113514 Radionuclide Vial Identifier Identifies the lot or unit serial number for the radionuclide component for the radiopharmaceutical.
113516 Prescription Identifier Administered Product's Prescription Number
113517 Organ Dose Information Information pertaining to the estimated absorbed radiation dose to an organ.
113518 Organ Dose The absorbed radiation dose to organ
113520 MIRD Pamphlet 1 Reference authorityMIRD Pamphlet No.1 (rev) ,Society of Nuclear Medicine, 1976
113521 ICRP Publication 53 Reference authorityICRP, 1988. Radiation Dose to Patients from Radiopharmaceuticals. ICRP Publication 53. Ann. ICRP 18 (1-4).
113522 ICRP Publication 80 Reference authorityICRP, 1998. Radiation Dose to Patients from Radiopharmaceuticals (Addendum to ICRP Publication 53). ICRP Publication 80. Ann. ICRP 28 (3).
113523 ICRP Publication 106 Reference authorityICRP, 2008. Radiation Dose to Patients from Radiopharmaceuticals - Addendum 3 to ICRP Publication 53. ICRP Publication 106. Ann. ICRP 38 (1-2).
113526 MIRDOSE Reference authorityStabin MG, Sparks RB, Crowe E (1994)MIRDOSE: personal computer software for internal dose assessment in nuclear medicine [Computer program]
113527 OLINDA-EXM Reference authorityStabin MG, Sparks RB, Crowe E (2005) OLINDA/EXM: The Second-Generation Personal Computer Software for Internal Dose Assessment in Nuclear Medicine [Computer program]
113528 Package Insert Reference authorityThe reported organ dose is based on radiopharmaceutical's package insert.
113529 Institutionally Approved Estimates Reference authorityThe reported organ dose is based on Institutionally approved estimates from the Radioactive Drug Research Committee (RDRC) of the institution itself.
113530 Investigational New Drug Reference authorityThe reported organ dose is based on an Investigation new drug.
113540 Activity Measurement Device The type of device that performed the activity measurement.
113541 Dose Calibrator The device that measures the radiation activity of the radiopharmaceutical
113542 Infusion System Radiopharmaceutical Infusion System
113543 Generator Radioisotope Generator
113550 Fasting Duration The number hours the patient has gone without food.
113551 Hydration Volume The amount of fluids the patient has consumed before the procedure.
113552 Recent Physical Activity A description of physical activity the patient performed before the start of the procedure, such as that which may affect imaging agent biodistribution.
113560 Acute unilateral renal blockage Blockage in one of the tubes (ureters) that drain urine from the kidneys
113561 Low Thyroid Uptake 5% or less Thyroid Uptake of Iodine
113562 High Thyroid Uptake 25% or higher Thyroid Uptake of Iodine
113563 Severely Jaundiced The patient exhibits symptoms severe of jaundice and/or has a Bilirubin >10 mg/dL.
113568 Extravasation visible in image Extravasation or paravenous administration of the product is visible in the images.
113570 Cockroft-Gault Formula estimation of GFR The measurement method of the Glomerular Filtration Rate is Cockroft-Gault Formula
113571 CKD-EPI Formula estimation of GFR The measurement method of the Glomerular Filtration Rate is CKD-EPI Formula
113572 Glomerular Filtration Rate (MDRD) The measurement method of the Glomerular Filtration Rate is MDRD
113573 Glomerular Filtration Rate non-black (MDRD) The measurement method of the Glomerular Filtration Rate is non-black MDRD
113574 Glomerular Filtration Rate black (MDRD) The measurement method of the Glomerular Filtration Rate is black (MDRD)
113575 Glomerular Filtration Rate female (MDRD) The measurement method of the Glomerular Filtration Rate is female (MDRD)
113576 Glomerular Filtration Rate Cystatin-based formula The measurement method of the Glomerular Filtration Rate is Cystatin-based formula
113577 Glomerular Filtration Rate Creatinine-based formula (Schwartz) The measurement method of the Glomerular Filtration Rate is Creatinine-based formula (Schwartz)
113601 Small: < 32.0 cm lateral thickness Small body thickness for calcium scoring adjustment. Lateral thickness is measured from skin-to-skin, at the level of the proximal ascending aorta, from an A/P localizer image.
113602 Medium: 32.0-38.0 cm lateral thickness Medium body thickness for calcium scoring adjustment. Lateral thickness is measured from skin-to-skin, at the level of the proximal ascending aorta, from an A/P localizer image.
113603 Large: > 38.0 cm lateral thickness Large body thickness for calcium scoring adjustment. Lateral thickness is measured from skin-to-skin, at the level of the proximal ascending aorta, from an A/P localizer image.
113605 Irradiation Event Label A human-readable label identifying an irradiation event.
113606 Label Type The type of a human-readable label.
113607 Series Number A number that identifies a Series. Corresponds to Series Number (0020,0011) of the .
113608 Acquisition Number A number that identifies an Acquisition. Corresponds to Acquisition Number (0020,0012) of the .
113609 Instance Number A number that identifies an Instance. Corresponds to Instance Number (0020,0013) of the .
113611 Stationary Acquisition Acquisition where the X-Ray source does not move in relation to the patient.
113612 Stepping Acquisition Acquisition where the X-Ray source moves laterally in relation to the patient.
113613 Rotational Acquisition Acquisition where the X-Ray source moves angularly in relation to the patient.
113620 Plane A Primary plane of a Biplane acquisition equipment.
113621 Plane B Secondary plane of a Biplane acquisition equipment.
113622 Single Plane Single plane acquisition equipment.
113630 Continuous Continuous X-Ray radiation is applied during an irradiation event.
113631 Pulsed Pulsed X-Ray radiation is applied during an irradiation event.
113650 Strip filter Filter with uniform thickness.
113651 Wedge filter Filter with variation in thickness from one edge to the opposite edge.
113652 Butterfly filter Filter with two triangular sections.
113653 Flat filter Filter with uniform thickness that is for spectral filtering only.
113661 Outline of lobulations A polyline defining the outline of a lobulated finding.
113662 Inner limits of fuzzy margin A polyline defining the inner limits of a finding with fuzzy margin.
113663 Outer limits of fuzzy margin A polyline defining the outer limits of a finding with fuzzy margin.
113664 Outline of spiculations A polyline defining the outline of the spiculations of a finding.
113665 Linear spiculation A polyline segment graphically indicating the location and direction of a spiculation of a finding.
113666 Pixelated spiculations A collection of points indicating the pixel locations of the spiculations of a finding.
113669 Orthogonal location arc Connected line segments indicating the center of location of a finding on an orthogonal view.
113670 Orthogonal location arc inner margin Connected line segments indicating the inner margin of the location of a finding on an orthogonal view.
113671 Orthogonal location arc outer margin Connected line segments indicating the outer location of a finding on an orthogonal view.
113680 Quality Control Intent This procedure is intended to gather data that is used for calibration or other quality control purposes.
113681 Phantom An artificial subject of an imaging study.
113682 ACR Accreditation Phantom - CT A phantom acceptable for the ACR Computed Tomography Accreditation program.
113683 ACR Accreditation Phantom - MR A phantom acceptable for the ACR Magnetic Resonance Imaging Accreditation program.
113684 ACR Accreditation Phantom - Mammography A phantom acceptable for the ACR Mammography Accreditation program.
113685 ACR Accreditation Phantom - Stereotactic Breast Biopsy A phantom acceptable for the ACR Stereotactic Breast Biopsy Accreditation program.
113686 ACR Accreditation Phantom - ECT A phantom acceptable for the ACR SPECT Accreditation program (but not for PET).
113687 ACR Accreditation Phantom - PET A phantom acceptable for the ACR PET Accreditation program (but not for SPECT).
113688 ACR Accreditation Phantom - ECT/PET A SPECT phantom with a PET faceplate acceptable for both the ACR SPECT and PET Accreditation programs.
113689 ACR Accreditation Phantom - PET Faceplate A PET faceplate (made to fit an existing flangeless or flanged ECT phantom) acceptable for the ACR PET Accreditation program.
113690 IEC Head Dosimetry Phantom A phantom used for CTDI measurement in head modes according to IEC 60601-2-44, Ed.2.1 (Head 16 cm diameter Polymethyl methacrylate PMMA).
113691 IEC Body Dosimetry Phantom A phantom used for CTDI measurement in body modes according to IEC 60601-2-44, Ed.2.1 (Body 32cm diameter Polymethyl methacrylate PMMA).
113692 NEMA XR21-2000 Phantom A phantom in accordance with NEMA standard XR-21-2000.
113701 X-Ray Radiation Dose Report X-Ray Radiation Dose Report.
113702 Accumulated X-Ray Dose Data X-Ray dose data accumulated over multiple irradiation events.
113704 Projection X-Ray Imaging using a point X-Ray source with a diverging beam projected onto a 2 dimensional detector.
113705 Scope of Accumulation Entity over which dose accumulation values are integrated.
113706 Irradiation Event X-Ray Data X-Ray dose data for a single Irradiation Event.
113710 Niobium or Niobium compound Material containing Niobium or a Niobium compound
113711 Europium or Europium compound Material containing Europium or a Europium compound
113720 Calibration Protocol Describes the method used to derive the calibration factor.
113721 Irradiation Event Type Denotes the type of irradiation event recorded.
113722 Dose Area Product Total Total calculated Dose Area Product (in the scope of the including report).
113723 Calibration DateTime Last calibration DateTime for the integrated dose meter or dose calculation.
113724 Calibration Responsible Party Individual or organization responsible for calibration.
113725 Dose (RP) Total Total Dose related to Reference Point (RP). (in the scope of the including report).
113726 Fluoro Dose Area Product Total Total calculated Dose Area Product applied in Fluoroscopy Modes (in the scope of the including report).
113727 Acquisition Dose Area Product Total Total calculated Dose Area Product applied in Acquisition Modes (in the scope of the including report).
113728 Fluoro Dose (RP) Total Dose applied in Fluoroscopy Modes, related to Reference Point (RP). (in the scope of the including report).
113729 Acquisition Dose (RP) Total Dose applied in Acquisition Modes, related to Reference Point (RP). (in the scope of the including report).
113730 Total Fluoro Time Total accumulated clock time of Fluoroscopy in the scope of the including report (i.e., the sum of the Irradiation Duration values for accumulated fluoroscopy irradiation events).
113731 Total Number of Radiographic Frames Accumulated Count of exposure pulses (single or multi-frame encoded) created from irradiation events performed with high dose (acquisition).
113732 Fluoro Mode Mode of application of X-Rays during Fluoroscopy.
113733 KVP Applied X-Ray Tube voltage at peak of X-Ray generation, in kilovolts; Mean value if measured over multiple peaks (pulses).
113734 X-Ray Tube Current Mean value of applied Tube Current.
113735 Exposure Time Cumulative time the patient has received X-Ray exposure during the irradiation event
113736 Exposure Mean value of X-Ray Current Time product.
113737 Distance Source to Reference Point Distance to the Reference Point (RP) defined according to IEC 60601-2-43 or equipment defined.
113738 Dose (RP) Dose applied at the Reference Point (RP).
113739 Positioner Primary End Angle Positioner Primary Angle at the end of an irradiation event. For further definition see (112011, DCM, "Positioner Primary Angle").
113740 Positioner Secondary End Angle Positioner Secondary Angle at the end of an irradiation event. For further definition see (112012, DCM, "Positioner Secondary Angle").
113742 Irradiation Duration Clock time from the start of loading time of the first pulse until the loading time trailing edge of the final pulse in the same irradiation event.Loading time is defined in IEC 60601-1-3:2008, 3.37, and described in IEC 60601-2-54:2009, 203.4.101.3.
113743 Patient Orientation Orientation of the Patient with respect to Gravity.
113744 Patient Orientation Modifier Enhances or modifies the Patient orientation specified in Patient Orientation.
113745 Patient Table Relationship Orientation of the Patient with respect to the Head of the Table.
113748 Distance Source to Isocenter Distance from the X-Ray Source to the Equipment C-Arm Isocenter.(Center of Rotation).
113750 Distance Source to Detector Measured or calculated distance from the X-Ray source to the detector plane in the center of the beam.
113751 Table Longitudinal Position Table Longitudinal Position with respect to an arbitrary reference chosen by the equipment. Table longitudinal motion is positive towards the left of the patient assuming the patient is positioned HEAD FIRST SUPINE.
113752 Table Lateral Position Table Lateral Position with respect to an arbitrary reference chosen by the equipment. Table lateral motion is positive towards the head of the patient assuming the patient is positioned HEAD FIRST.
113753 Table Height Position Table Height Position with respect to an arbitrary chosen reference by the equipment in (mm). Table motion downwards is positive.
113754 Table Head Tilt Angle Angle of the head-feet axis of the table in degrees relative to the horizontal plane. Positive values indicate that the head of the table is upwards.
113755 Table Horizontal Rotation Angle Rotation of the table in the horizontal plane (clockwise when looking from above the table).
113756 Table Cradle Tilt Angle Angle of the left-right axis of the table in degrees relative to the horizontal plane. Positive values indicate that the left of the table is upwards.
113757 X-Ray Filter Material X-Ray absorbing material used in the filter.
113758 X-Ray Filter Thickness Minimum The minimum thickness of the X-Ray absorbing material used in the filters.
113759 Table Longitudinal End Position Table Longitudinal Position at the end of an irradiation event.
113760 Table Lateral End Position Table Lateral Position at the end of an irradiation event.
113761 Table Height End Position Table Height Position at the end of an irradiation event.
113763 Calibration Uncertainty Uncertainty of the 'actual' value.
113764 Acquisition Plane Identification of Acquisition Plane with Biplane systems.
113766 Focal Spot Size Nominal Size of Focal Spot of X-Ray Tube.
113767 Average X-Ray Tube Current Average X-Ray Tube Current averaged over time for pulse or for continuous Fluoroscopy.
113768 Number of Pulses Number of pulses applied by X-Ray systems during an irradiation event (acquisition run or pulsed fluoro).
113769 Irradiation Event UID Unique identification of a single irradiation event.
113770 Column Angulation Angle of the X-Ray beam in degree relative to an orthogonal axis to the detector plane.
113771 X-Ray Filters Devices used to modify the energy or energy distribution of X-Rays.
113772 X-Ray Filter Type Type of filter(s) inserted into the X-Ray beam.
113773 X-Ray Filter Thickness Maximum The maximum thickness of the X-Ray absorbing material used in the filters.
113780 Reference Point Definition System provided definition of the Reference Point used for Dose calculations.
113788 Collimated Field Height Distance between the collimator blades in pixel column direction as projected at the detector plane.
113789 Collimated Field Width Distance between the collimator blades in pixel row direction as projected at the detector plane.
113790 Collimated Field Area Collimated field area at image receptor. Area for compatibility with IEC 60601-2-43.
113791 Pulse Rate Pulse rate applied by equipment during Fluoroscopy.
113792 Distance Source to Table Plane Measured or calculated distance from the X-Ray source to the table plane in the center of the beam.
113793 Pulse Width (Average) X-Ray pulse width.
113794 Dose Measurement Device Calibrated device to perform dose measurements.
113795 Acquired Image Image acquired during a specified event.
113800 DLP to E conversion via MC computation Effective Dose evaluation from the product of Dose Length Product (DLP) and the Effective Dose Conversion Factor (E/DLP in units of mSv/mGy-cm), where the ratio is derived by means of Monte Carlo computations.
113801 CTDIfreeair to E conversion via MC computation Effective Dose evaluation from the product of the Mean CTDIfreeair and the ratio E/CTDIfreeair (mSv/mGy), where the ratio is derived by means of Monte Carlo computations.
113802 DLP to E conversion via measurement Effective Dose evaluation from the product of Dose Length Product (DLP) and the Effective Dose Conversion Factor (E/DLP in units of mSv/mGy-cm), where the ratio is derived by means of dosimetric measurements with an anthropomorphic phantom.
113803 CTDIfreeair to E conversion via measurement Effective Dose evaluation from the product of the Mean CTDIfreeair and the ratio E/CTDIfreeair (mSv/mGy), where the ratio is derived by means of dosimetric measurements with an anthropomorphic phantom.
113804 Sequenced Acquisition The CT acquisition was performed by acquiring single or multi detector data while rotating the source about the gantry while the table is not moving. Additional slices are acquired by incrementing the table position and again rotating the source about the gantry while the table is not moving.
113805 Constant Angle Acquisition The CT acquisition was performed by holding the source at a constant angle and moving the table to obtain a projection image.
113806 Stationary Acquisition The CT acquisition was performed by holding the table at a constant position and acquiring multiple slices over time at the same location.
113807 Free Acquisition The CT acquisition was performed while rotating the source about the gantry while the table movement is under direct control of a human operator or under the control of an analysis application.
113808 ICRP Pub 60 Reference authority1990 Recommendations of the International Commission on Radiological Protection (ICRP Publication 60, published as the Annals of the ICRP Vol. 21, No. 1-3, Pergamon Press,1991).
113809 Start of X-Ray Irradiation Start DateTime of the first X-Ray Irradiation Event of the accumulation within a Study.
113810 End of X-Ray Irradiation End DateTime of the last X-Ray Irradiation Event of the accumulation within a Study.
113811 CT Accumulated Dose Data X-Ray dose accumulated over multiple CT irradiation events.
113812 Total Number of Irradiation Events Total number of events during the defined scope of accumulation.
113813 CT Dose Length Product Total The total dose length product for the defined scope of accumulation.
113814 CT Effective Dose Total The total Effective Dose at the defined scope of accumulation.
113815 Patient Model Identification of the reference-patient model used when Effective Dose is evaluated via Monte Carlo calculations or from a Dose Length Product conversion factor based on Monte Carlo calculations.
113816 Condition Effective Dose measured References the physical phantom and the type of dosimeter used when measurements are done to establish Effective Dose Conversion Factors (E/DLP) or ratios E/CTDIfreeair.
113817 Effective Dose Phantom Type Type of Effective Dose phantom used.
113818 Dosimeter Type Type of dosimeter used.
113819 CT Acquisition General description of the CT Irradiation event.
113820 CT Acquisition Type Method of the CT acquisition.
113821 X-Ray Filter Aluminum Equivalent Thickness of an equivalent filter in mm in Aluminum.
113822 CT Acquisition Parameters General description of the acquisition parameters.
113823 Number of X-Ray Sources Number of X-Ray sources.
113824 Exposure Time Total time the patient has received X-Ray exposure during the irradiation event.
113825 Scanning Length Length of the table travel during the entire tube loading, according to IEC 60601-2-44Scanning Length might be longer than the programmed acquisition length (Length of Reconstructable Volume)
113826 Nominal Single Collimation Width The value of the nominal width referenced to the location of the isocenter along the z axis of a single row of acquired data in mm.
113827 Nominal Total Collimation Width The value of the nominal width referenced to the location of the isocenter along the z axis of the total collimation in mm over the area of active X-Ray detection.
113828 Pitch Factor For Spiral scanning: Pitch Factor = (Table Feed per Rotation (mm)) /(Nominal Total Collimation Width (mm))For Sequenced scanning: Pitch Factor = (Table Feed per single Sequenced scan (mm)) /(Nominal Total Collimation Width (mm)).
113829 CT Dose General description of CT dose values.
113830 Mean CTDIvol "Mean CTDIvol" refers to the average value of the CTDIvol associated with this acquisition.
113831 CT X-Ray Source Parameters Identification, tube-potential, tube-current, and exposure-time parameters associated with an X-Ray source during an acquisition.
113832 Identification of the X-Ray Source Identifies the particular X-Ray source (in a multi-source CT system) for which the set of X-Ray source parameter values is reported.
113833 Maximum X-Ray Tube Current Maximum X-Ray tube current.
113834 Exposure Time per Rotation The exposure time for one rotation of the source around the object in s.
113835 CTDIw Phantom Type A label describing the type of phantom used for CTDIW measurement according to IEC 60601-2-44 (Head 16 cm diameter PMMA, Body 32 cm diameter PMMA).
113836 CTDIfreeair Calculation Factor The CTDIfreeair Calculation Factor is the CTDIfreeair per mAs, expressed in units of mGy/mAs. The CTDIfreeair Calculation Factor may be used in one method calculating Dose.
113837 Mean CTDIfreeair The average value of the free-in-air CTDI associated with this acquisition.
113838 DLP Dose Length Product (DLP), expressed in mGy-cm, is an index characterizing the product of the CTDIvol and the length scanned. For Spiral scanning, DLP = CTDIvol ✕ Scanning Length. For Sequenced scanning, DLP = CTDIvol ✕ Nominal Total Collimation Width ✕ Cumulative Exposure Time / Exposure Time per Rotation. For Stationary and Free scanning, DLP = CTDIvol ✕ Nominal Total Collimation Width.
113839 Effective Dose Effective dose in mSv.
113840 Effective Dose Conversion Factor Effective Dose per DLP, reference value for Effective Dose calculation, expressed in mSv/mGY.cm.
113841 ICRP Pub 103 Effective Dose Reference authority2007 Recommendations of the International Commission on Radiological Protection (ICRP Publication 103, published as the Annals of the ICRP Vol. 37, No. 2-4, Elsevier, 2007).
113842 X-Ray Modulation Type The type of exposure modulation used for the purpose of limiting the dose.
113845 Exposure Index Measure of the detector response to radiation in the relevant image region of an image acquired with a digital X-Ray imaging system as defined in IEC 62494-1.
113846 Target Exposure Index The target value used to calculate the Deviation Index as defined in IEC 62494-1.
113847 Deviation Index A scaled representation of the accuracy of the Exposure Index compared to the Target Exposure Index as defined in IEC 62494-1.
113850 Irradiation Authorizing The clinician responsible for determining that the irradiating procedure was appropriate for the indications.
113851 Irradiation Administering The person responsible for the administration of radiation.
113852 Irradiation Event An irradiation event is the loading of X-Ray equipment caused by a single continuous actuation of the equipment's irradiation switch, from the start of the loading time of the first pulse until the loading time trailing edge of the final pulse. Any automatic on-off switching of the irradiation source during the event is not treated as separate events, rather the event includes the time between start and stop of irradiation as triggered by the user.
113853 Irradiation Event UID Unique Identifier of an Irradiation Event.
113854 Source of Dose Information Method by which dose-related details of an Irradiation Event were obtained.
113855 Total Acquisition Time Total accumulated acquisition clock time in the scope of the including report (i.e., the sum of the Irradiation Duration values for accumulated acquisition irradiation events).
113856 Automated Data Collection Direct recording of data by a relevant system.
113857 Manual Entry Recording of data by a human operator, including manual transcription of electronic data.
113858 MPPS Content The data is taken from an MPPS SOP Instance.
113859 Irradiating Device A device exposing a patient to ionizing radiation.
113860 15cm from Isocenter toward Source 15cm from the isocenter towards the X-Ray source; See IEC 60601-2-43.
113861 30cm in Front of Image Input Surface 30cm in front (towards the tube) of the input surface of the image receptor; See FDA Federal Performance Standard for Diagnostic X-Ray Systems §1020.32(d) (3).
113862 1cm above Tabletop 1cm above the patient tabletop or cradle; See FDA Federal Performance Standard for Diagnostic X-Ray Systems §1020.32(d) (3).
113863 30cm above Tabletop 30cm above the patient tabletop of cradle; See FDA Federal Performance Standard for Diagnostic X-Ray Systems §1020.32(d) (3).
113864 15cm from Table Centerline 15cm from the centerline of the X-Ray table and in the direction of the X-Ray source; See FDA Federal Performance Standard for Diagnostic X-Ray Systems §1020.32(d) (3).
113865 Entrance exposure to a 4.2 cm breast thickness Standard breast means a 4.2 centimeter (cm) thick compressed breast consisting of 50 percent glandular and 50 percent adipose tissue.See Department of Health and Human Services, Food and Drug Administration. Mammography quality standards; final rule. Federal Register. Oct. 28, 1997; 68(208):55852-55994.
113866 Copied From Image Attributes The data is copied from information present in the image Attributes.
113867 Computed From Image Attributes The data is computed from information present in the image Attributes.
113868 Derived From Human-Readable Reports The data is derived from human-readable reports.
113870 Person Name The name of a specific person.
113871 Person ID An identification number or code for a specific person.
113872 Person ID Issuer The organization that issued a Person ID.
113873 Organization Name The name of an organization.
113874 Person Role in Organization The role played by a person in an organization.
113875 Person Role in Procedure The role played by a person in a procedure.
113876 Device Role in Procedure The role played by a device in a procedure.
113877 Device Name The name used to refer to a device; usually locally unique.
113878 Device Manufacturer Manufacturer of a device.
113879 Device Model Name Model Name of a device.
113880 Device Serial Number Serial Number of a device.
113890 All Planes All planes of a multi-plane acquisition equipment.
113893 Length of Reconstructable Volume The length from which images may be reconstructed (i.e., excluding any overranging performed in a spiral acquisition that is required for data interpolation).Value is distinct from (1113825, DCM, "Scanning Length"), which is the actual length of the table travel during the entire tube loading, according to IEC 60601-2-44, and includes overranging. Also distinct from any actual Reconstructed Volume, which may depend on the slice thickness chosen for a particular reconstruction.
113895 Top Z Location of Reconstructable Volume The Z location that is the top (highest Z value) of the Reconstructable Volume. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference.
113896 Bottom Z Location of Reconstructable Volume The Z location that is the bottom (lowest Z value) of the Reconstructable Volume. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference.
113897 Top Z Location of Scanning Length The Z location that is the top (highest Z value) of the scanning length. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference.
113898 Bottom Z Location of Scanning Length The Z location that is the bottom (lowest Z value) of the scanning length. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference.
113899 Exposed Range The range along the z axis of the total volume irradiated, per IEC 60601-2-44, Ed. 3, 203.115(b).The start and stop of loading corresponding to the outer edge of the full width half maximum of the free-in-air dose profile for the beam collimation used.
113900 Dose Check Alert Details Report section about cumulative dose alerts during an examination.
113901 DLP Alert Value Configured Flag denoting whether a DLP Alert Value was configured.
113902 CTDIvol Alert Value Configured Flag denoting whether a CTDIvol Alert Value was configured.
113903 DLP Alert Value Cumulative Dose Length Product value configured to trigger an alert.
113904 CTDIvol Alert Value Cumulative CTDIvol value configured to trigger an alert.
113905 Accumulated DLP Forward Estimate A forward estimate of the accumulated DLP plus the estimated DLP for the next Protocol Element Group.
113906 Accumulated CTDIvol Forward Estimate A forward estimate at a given location of the accumulated CTDIvol plus the estimated CTDIvol for the next Protocol Element Group.
113907 Reason for Proceeding Reason provided for proceeding with a procedure that is projected to exceed a configured dose value.
113908 Dose Check Notification Details Report section about dose notifications during a protocol element.
113909 DLP Notification Value Configured Flag denoting whether a DLP Notification Value was configured.
113910 CTDIvol Notification Value Configured Flag denoting whether a CTDIvol Notification Value was configured.
113911 DLP Notification Value Dose Length Product value configured to trigger a notification for a given protocol element.
113912 CTDIvol Notification Value CTDIvol value configured to trigger a notification for a given protocol element.
113913 DLP Forward Estimate A forward estimate of the DLP for the next Protocol Element Group.
113914 CTDIvol Forward Estimate A forward estimate of the CTDIvol for the next Protocol Element Group.
113915 Alternative dose alert behavior active Flag denoting whether alternative dose alert behavior has been active for CT guided interventional procedure according to the NEMA Dose Check Standard .
113921 Radiation Exposure The amount of ionizing radiation to which the patient was exposed.
113922 Radioactive Substance Administered Type, amount and route of radioactive substance administered.
113923 Radiation Exposure and Protection Information Exposure to ionizing radiation and associatedpreventive measures used to reduce the exposure of parts of the body like lead apron or eye, thyroid gland or gonad protection.
113930 Size Specific Dose Estimate The Size-Specific Dose Estimate is a patient dose estimate that takes into account the size of the patient, such as described in or .
113931 Measured Lateral Dimension The side-to-side (left to right) dimension of the body part being scanned (per ).
113932 Measured AP Dimension The thickness of the body part being scanned, in the antero-posterior dimension (per ).
113933 Derived Effective Diameter The diameter of the patient at a given location along the Z-axis of the patient, assuming that the patient has a circular cross-section (per ).
113934 AAPM 204 Lateral Dimension The Size Specific Dose Estimation is computed using Table 1B (32cm phantom) or Table 2B (16cm phantom) of .
113935 AAPM 204 AP Dimension The Size Specific Dose Estimation is computed using Table 1C (32cm phantom) or Table 2C (16cm phantom) of .
113936 AAPM 204 Sum of Lateral and AP Dimension The Size Specific Dose Estimation is computed using Table 1A (32cm phantom) or Table 2A (16cm phantom) of .
113937 AAPM 204 Effective Diameter Estimated From Patient Age The Size Specific Dose Estimation is computed using Table 1D (32cm phantom) or Table 2D (16cm phantom) using an effective diameter estimated from the patient's age using Table 3 of .
113940 System Calculated Values calculated from other existing parameters.
113941 In Detector Plane A segmented region of the detector surface within the irradiated area (but might not be near the center of the detector).
113942 X-Ray Reading Device A device that creates digital images from X-Ray detectors (Direct, Indirect or Storage).
113943 X-Ray Source Data Available Parameters related to the X-Ray source (generator, tube, etc) are available to the recording application.
113944 X-Ray Mechanical Data Available Parameters related to the X-Ray Mechanical System (Stand, Table) are available to the recording application.
113945 X-Ray Detector Data Available Parameters related to the X-Ray Detector are available to the recording application.
113946 Projection Eponymous Name Describes the radiographic method of patient, tube and detector positioning to achieve a well described projection or view.
113947 Detector Type Type of Detector used to acquire data.
113948 Direct Detector Detector that directly transforms the input signal to pixel values.
113949 Indirect Detector Detector that transforms an intermediate signal into pixel values.
113950 Storage Detector Storage detector that stores a signal that is later transformed by a reader into pixel values.
113951 Film Film that is scanned to create pixel values.
113952 Table Mount The cassette/detector is mounted in the patient table.
113953 Unmounted Detector The cassette/detector is not mounted..
113954 Upright Stand Mount The cassette/detector is mounted in an upright stand.
113955 C-Arm Mount The cassette/detector is mounted on a c-arm.
113956 CR/DR Mechanical Configuration Method of mounting or positioning a CR/DR cassette or detector.
113957 Fluoroscopy-Guided Projection Radiography System An integrated projection radiography system capable of fluoroscopy.
113958 Integrated Projection Radiography System A projection radiography system where the X-Ray detector, X-Ray Source and gantry components are integrated and the managing system is able to access details of each component.
113959 Cassette-based Projection Radiography System A projection radiography system where the X-Ray detector, X-Ray Source and gantry components are not integrated.
113961 Reconstruction Algorithm Description of the algorithm used when reconstructing the image from the data acquired during the acquisition process.
113962 Filtered Back Projection An algorithm for reconstructing an image from multiple projections by back-projecting the measured values along the line of the projection and filtering the result to reduce blurring.
113963 Iterative Reconstruction An algorithm for reconstructing an image from multiple projections by starting with an assumed reconstructed image, computing projections from the image, comparing the original projection data and updating the reconstructed image based upon the difference between the calculated and the actual projections.
113964 At Surface of Patient A point at the surface of the patient within the irradiated area where the X-Ray beam enters the patient (i.e. towards the tube).
113965 100cm from X-Ray Source 100cm from the X-Ray source along the central ray of the X-Ray beam.
113970 Procedure Step To This Point The period of time from the start of a Procedure Step until the time point established by the context of the reference.
113980 Water Equivalent Diameter The diameter of a cylinder of water having the same X-Ray attenuation as the patient for a specified reconstructed slice (e.g., as described in ).
113981 Water Equivalent Diameter Representative Value The Water Equivalent Diameter is a value at a single location sufficiently representative of the body region.
113982 Water Equivalent Diameter Integrated Across Scan Range The Water Equivalent Diameter integrates values for a sample of reconstructed slices across the entire scan range.
113983 Water Equivalent Diameter From Raw Data The Water Equivalent Diameter value is derived from Raw Data rather than reconstructed slices.See .
113984 Water Equivalent Diameter From Localizer The Water Equivalent Diameter value is derived from a Localizer image.See .
113985 Series or Instance used for Water Equivalent Diameter estimation Unique identifier of the Series or Instance(s) used for Water Equivalent Diameter estimation, whether it be a Series of reconstructed single slice images or one or more Enhanced Multi-frame images or a Raw Data Series or Instance.
113986 Z value of location of Water Equivalent Diameter estimation The Z location used for Water Equivalent Diameter estimation at a single location whether it be computed using a reconstructed slice or Localizer or Raw Data. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference.
113987 AAPM 220 A report describing methods of calculation of diameters of cylinders of water having the same X-Ray attenuation as reconstructed CT slices of patients described in .
113988 Estimated from Water Equivalent Diameter The Size Specific Dose Estimate is calculated from a single Water Equivalent Diameter value using a conversion factor as described in .
113989 Arithmetic Average of SSDE(z) The Size Specific Dose Estimate is an arithmetic average of SSDE(z), calculated from Dw(z) at several z-positions over the reconstruction length. The z-positions may or may not correspond to reconstructed slices. See .
113990 Arithmetic Average of Dw(z) The Water Equivalent Diameter is an arithmetic average of Dw(z) at several z-positions over the reconstruction length. The z-positions may or may not correspond to reconstructed slices. See .
113991 Dw Conversion Factor Coefficients The a and b coefficients of an exponential function as described in . The function generates a conversion factor based on a Water Equivalent Diameter value (Dw). Multiplying the Dw value by the conversion factor produces a Size Specific Dose Estimate.
113992 Water Equivalent Diameter From Limited FOV Images The Water Equivalent Diameter is derived from reconstructed images that do not cover the full FOV.
113993 Size Specific Dose Estimate At Longitudinal Position Z Estimate of the average absorbed dose to the material contained in an axial plane at longitudinal position z of the object scanned. See .
113994 Longitudinal Position Z The patient relative longitudinal position at which other value(s) have been estimated.
113995 Water Equivalent Diameter At Longitudinal Position Z Diameter of a cylinder of water having the same averaged absorbed dose as the material contained in an axial plane at longitudinal position z of the object scanned, calculable for a material of any composition, and quantifying the attenuation of any material in terms of the attenuation of water. See .
114000 Not a number Measurement not available: Not a number (per IEEE 754).
114001 Negative Infinity Measurement not available: Negative Infinity (per IEEE 754).
114002 Positive Infinity Measurement not available: Positive Infinity (per IEEE 754).
114003 Divide by zero Measurement not available: Divide by zero (per IEEE 754).
114004 Underflow Measurement not available: Underflow (per IEEE 754).
114005 Overflow Measurement not available: Overflow (per IEEE 754).
114006 Measurement failure Measurement not available: Measurement failure.
114007 Measurement not attempted Measurement not available: Measurement not attempted.
114008 Calculation failure Measurement not available: Calculation failure.
114009 Value out of range Measurement not available: Value out of range.
114010 Value unknown Measurement not available: Value unknown.
114011 Value indeterminate Measurement not available: Value indeterminate.
114201 Time of flight Measures the time-of-flight of a light signal between the camera and the subject for each point of the image.
114202 Interferometry Interferometry is a family of techniques in which waves are superimposed in order to extract depth information about the scanned object.
114203 Laser scanning Laser scanning describes the general method to sample or scan a surface using laser technology.
114204 Pattern projection Projecting a narrow band of light onto a three-dimensionally shaped surface produces a line of illumination that appears distorted from other perspectives than that of the projector. It can be used for an exact geometric reconstruction of the surface shape.
114205 Shape from shading A technique for estimating the surface normal of an object by observing that object under different lighting conditions.
114206 Shape from motion A technique for estimating the surface normal of an object by observing that object under different motions.
114207 Confocal imaging An optical imaging technique used to increase optical resolution and contrast of a micrograph by using point illumination and a spatial pinhole to eliminate out-of-focus light in specimens that are thicker than the focal plane. It enables the reconstruction of 3D structures from the obtained images.
114208 Point Cloud Algorithmic Point cloud that was calculated by an algorithm.
114209 Turntable Scan Method Scanning the object from different views by placing it on a rotating table.
114210 High resolution Higher resolution with a longer acquisition time.
114211 Fast mode Lower resolution with a shorter acquisition time.
114213 Iterative Closest Point An algorithm employed to minimize the difference between two clouds of points. It iteratively revises the transformation (translation, rotation) needed to minimize the distance between the points of two point clouds.
114215 Freehand Human controlled minimization of the distance between the points of two point clouds.
114216 Checkerboard Scanning the object from different views by placing it in front of a checkerboard pattern.
120999 Device Description Description in free form text describing the device.
121000 Unique Device Identifiers Unique Device Identifiers (UDIs) of the entire equipment.
121001 Quotation Mode Type of source for observations quoted from an external source.
121002 Quoted Source Reference to external source of quoted observations.
121003 Document Documentary source of quoted observations.
121004 Verbal Verbal source of quoted observations.
121005 Observer Type Type of observer that created the observations.
121006 Person Human observer created the observations.
121007 Device Automated device created the observations.
121008 Person Observer Name Name of human observer that created the observations.
121009 Person Observer's Organization Name Organization or institution with which the human observer is affiliated for the context of the current observation.
121010 Person Observer's Role in the Organization Organizational role of human observer for the context of the current observation.
121011 Person Observer's Role in this Procedure Procedural role of human observer for the context of the current observation.
121012 Device Observer UID Unique identifier of automated device that created the observations.
121013 Device Observer Name Institution-provided identifier of automated device that created the observations.
121014 Device Observer Manufacturer Manufacturer of automated device that created the observations.
121015 Device Observer Model Name Manufacturer-provided model name of automated device that created the observations.
121016 Device Observer Serial Number Manufacturer-provided serial number of automated device that created the observations.
121017 Device Observer Physical Location During Observation Location of automated device that created the observations whilst the observations were being made.
121018 Procedure Study Instance UID Unique identifier for the Study or Requested Procedure.
121019 Procedure Study Component UID Unique identifier for the Performed Procedure Step.
121020 Placer Number Identifier for the Order (or Service Request) assigned by the order placer system.
121021 Filler Number Identifier for the Order (or Service Request) assigned by the order filler system.
121022 Accession Number A departmental Information System generated number that identifies the Imaging Service Request.
121023 Procedure Code Type of procedure scheduled or performed.
121024 Subject Class Type of observation subject.
121025 Patient A patient is the subject of observations.
121026 Fetus Fetus of patient is the subject of observations.
121027 Specimen Specimen is the subject of observations.
121028 Subject UID Unique Identifier of patient or fetus who is the subject of observations.
121029 Subject Name Name of patient who is the subject of observations.
121030 Subject ID Identifier of patient or fetus who is the subject of observations.
121031 Subject Birth Date Birth Date of patient who is the subject of observations.
121032 Subject Sex Sex of patient who is the subject of observations.
121033 Subject Age Age of patient who is the subject of observations.
121034 Subject Species Species of patient who is the subject of observations.
121035 Subject Breed The breed of the subject.
121036 Mother of fetus Name of mother of fetus that is the subject of observations.
121037 Fetus number
121038 Number of Fetuses
121039 Specimen UID Unique Identifier of specimen that is the subject of observations.
121040 Specimen Accession Number Accession Number of specimen that is the subject of observations
121041 Specimen Identifier Identifier of specimen that is the subject of observations.
121042 Specimen Type Coded category of specimen that is the subject of observations
121043 Slide Identifier Identifier of specimen microscope slide that is the subject of observations
121044 Slide UID Unique Identifier of specimen microscope slide that is the subject of observations
121045 Language The language of the content, being a language that is primarily used for human communication.
121046 Country of Language The country-specific variant of language.
121047 Language of Value The language of the value component of a name-value pair.
121048 Language of Name and Value The language of both the name component and the value component of a name-value pair.
121049 Language of Content Item and Descendants The language of the current Content Item (node in a tree of content) and all its descendants.
121050 Equivalent Meaning of Concept Name A precoordinated coded concept or text meaning for the name component of a name-value pair that is equivalent to the post-coordinated meaning conveyed by the coded name and its concept modifier children.
121051 Equivalent Meaning of Value A precoordinated coded concept or text meaning for the value component of a name-value pair that is equivalent to the post-coordinated meaning conveyed by the coded value and its concept modifier children.
121052 Presence of property Whether or not the property concept being modified is present or absent.
121053 Present
121054 Absent
121055 Path A set of points on an image, that when connected by line segments, provide a polyline from which a linear measurement was inferred.
121056 Area outline A set of points on an image, that when connected by line segments, provide a closed polyline that is the border of a defined region from which an area, or two-dimensional measurement, was inferred.
121057 Perimeter outline A set of points on an image, that when connected by line segments, provide a closed polyline that is a two-dimensional border of a three-dimensional region's intersection with, or projection into the image.
121058 Procedure reported The imaging procedure whose results are reported.
121059 Presence Undetermined Presence or absence of a property is undetermined
121060 History
121061 Device Observer Manufacturer Class UID Manufacturer-provided Class UID(s) of device that created the observations.
121062 Request
121064 Current Procedure Descriptions
121065 Procedure Description A description of the imaging procedure.
121066 Prior Procedure Descriptions
121068 Previous Findings
121069 Previous Finding An observation found on a prior imaging study.
121070 Findings
121071 Finding An observation found on an imaging study.
121072 Impressions
121073 Impression An interpretation in the clinical context of the finding(s) on an imaging study.
121074 Recommendations
121075 Recommendation A recommendation for management or investigation based on the findings and impressions of an imaging study.
121076 Conclusions
121077 Conclusion An interpretation in the clinical context of the finding(s) on an imaging study.
121078 Addendum
121079 Baseline Initial images used to establish a beginning condition that is used for comparison over time to look for changes. [Paraphrases NCI-PT (C1442488, UMLS, "Baseline"), which is defined as "An initial measurement that is taken at an early time point to represent a beginning condition, and is used for comparison over time to look for changes. For example, the size of a tumor will be measured before treatment (baseline) and then afterwards to see if the treatment had an effect. A starting point to which things may be compared."]
121080 Best illustration of finding A selection of composite instances that best illustrates a particular finding.
121081 Physician
121082 Nurse
121083 Technologist
121084 Radiographer
121085 Intern
121086 Resident
121087 Registrar
121088 Fellow A medical practitioner undergoing sub-specialty training.
121089 Attending [Consultant]
121090 Scrub nurse
121091 Surgeon
121092 Sonologist A medical practitioner with sub-specialty training in Ultrasound.
121093 Sonographer
121094 Performing The person responsible for performing the procedure.
121095 Referring The person responsible for referring the patient for the procedure.
121096 Requesting The person responsible for requesting the procedure.
121097 Recording The person responsible for recording the procedure or observation.
121098 Verifying The person responsible for verifying the recorded procedure or observation.
121099 Assisting The person responsible for assisting with the procedure.
121100 Circulating The person responsible for making preparations for and monitoring the procedure.
121101 Standby The person responsible for standing by to assist with the precedure if required.
121102 Other sex Other sex.
121103 Undetermined sex Sex of subject undetermined at time of encoding.
121104 Ambiguous sex Ambiguous sex.
121105 Radiation Physicist Radiation Physicist.
121106 Comment Comment.
121109 Indications for Procedure Indications for Procedure
121110 Patient Presentation Patient condition at the beginning of a healthcare encounter
121111 Summary Summary of a procedure, including most significant findings
121112 Source of Measurement Image or waveform used as source for measurement.
121113 Complications Complications from a procedure
121114 Performing Physician Physician who performed a procedure.
121115 Discharge Summary Summary of patient condition upon Discharge from a healthcare facility.
121116 Proximal Finding Site Proximal Anatomic Location for a differential measurement; may be considered subtype of term (363698007, SCT, "Finding Site").
121117 Distal Finding Site Distal Anatomic Location for a differential measurement; may be considered subtype of term (363698007, SCT, "Finding Site").
121118 Patient Characteristics Patient Characteristics (findings).
121120 Cath Lab Procedure Log Time-stamped record of events that occur during a catheterization procedure.
121121 Room identification Room identification.
121122 Equipment Identification Equipment identification.
121123 Patient Status or Event A recorded Patient Status or an event involving a patient.
121124 Procedure Action Item ID Identification of a step, action, or phase of a procedure.
121125 DateTime of Recording of Log Entry DateTime of Recording of an Entry in an Event Log.
121126 Performed Procedure Step SOP Instance UID SOP Instance UID of a Performed Procedure Step.
121127 Performed Procedure Step SOP Class UID SOP Class UID of a Performed Procedure Step.
121128 Procedure Action Duration Duration of a step, action, or phase of a procedure.
121130 Start Procedure Action Item Beginning of a step, action, or phase of a procedure.
121131 End Procedure Action Item End of a step, action, or phase of a procedure.
121132 Suspend Procedure Action Item Suspension of a step, action, or phase of a procedure.
121133 Resume Procedure Action Item Resumption of a step, action, or phase of a procedure.
121135 Observation DateTime Qualifier Concept modifier for the DateTime of Recording of an Entry in an Event Log.
121136 DateTime Unsynchronized Recorded DateTime had its source in a system clock not synchronized to other recorded DateTimes.
121137 DateTime Estimated Recorded DateTime is estimated.
121138 Image Acquired Event of the acquisition of an image.
121139 Modality Type of device, process or method used to acquire or derive data.
121140 Number of Frames Number of Frames in a multi-frame image.
121141 Image Type Descriptor of an Image.
121142 Acquisition Duration Duration of the acquisition of an image or a waveform.
121143 Waveform Acquired Event of the acquisition of an image.
121144 Document Title Document Title.
121145 Description of Material Description of Material used in a procedure.
121146 Quantity of Material Quantity of Material used in a procedure.
121147 Billing Code Billing Code for materials used in a procedure.
121148 Unit Serial Identifier Unit or Device Serial Identifier.
121149 Lot Identifier Lot Identifier.
121150 Device Code Vendor or local coded value identifying a device.
121151 Lesion Identifier Identification of a Lesion observed during an imaging procedure.
121152 Person administering drug/contrast Person administering drug/contrast.
121153 Lesion Risk Assessment of the risk a coronary lesion presents to the health of a patient.
121154 Intervention attempt identifier Identifier for an attempted Intervention.
121155 Deployment Use of a device to deploy another device.
121156 Percutaneous Entry Action Action of a clinical professional at the site of percutaneous access to a patient's cardiovascular system.
121157 Begin Circulatory Support The action or event of beginning circulatory support for a patient.
121158 End Circulatory Support The action or event of ending circulatory support for a patient.
121160 Oxygen Administration Rate Rate of Oxygen Administration.
121161 Begin Oxygen Administration The action or event of beginning administration of oxygen to a patient.
121162 End oxygen administration The action or event of ending administration of oxygen to a patient.
121163 By ventilator Method of administration of oxygen to a patient by ventilator.
121165 Patient Assessment Performed The action or event of assessing the clinical status of a patient.
121166 Begin Pacing The action or event of beginning pacing support for a patient.
121167 End Pacing The action or event of ending pacing support for a patient.
121168 Begin Ventilation The action or event of beginning ventilation support for a patient.
121169 End Ventilation The action or event of ending ventilation support for a patient.
121171 Tech Note Procedural note originated by a technologist.
121172 Nursing Note Procedural note originated by a nurse.
121173 Physician Note Procedural note originated by a Physician.
121174 Procedure Note General procedural note.
121180 Key Images List of references to images considered significant
121181 DICOM Object Catalog List of references to DICOM SOP Instances.
121190 Referenced Frames Individual frames selected as a subset of a multi-frame image.
121191 Referenced Segment Segment selected as a subset of a segmentation image, specifically the pixels/voxels identified as belonging to the classification of the identified segment.
121192 Device Subject A device is the subject of observations.
121193 Device Subject Name Name or other identifier of a device that is the subject of observations.
121194 Device Subject Manufacturer Manufacturer of a device that is the subject of observations.
121195 Device Subject Model Name Model Name of a device that is the subject of observations.
121196 Device Subject Serial Number Serial Number of a device that is the subject of observations.
121197 Device Subject Physical Location during observation Physical Location of a device that is the subject of observations during those observations.
121198 Device Subject UID Unique Identifier of a device that is the subject of observations.
121200 Illustration of ROI Illustration of a region of interest.
121201 Area Outline
121202 Area of Defined Region
121206 Distance A one dimensional, or linear, numeric measurement.
121207 Height Vertical measurement value.
121208 Inter-Marker Distance Distance between marks on a device of calibrated size.
121210 Path
121211 Path length A one dimensional, or linear, numeric measurement along a polyline.
121213 Perimeter Outline
121214 Referenced Segmentation Frame Frame selected from a segmentation image, specifically the pixels/voxels identified as belonging to the classification of the segment encompassing the identified frame.
121216 Volume estimated from single 2D region A three-dimensional numeric measurement that is approximate, based on a two-dimensional region in a single image.
121217 Volume estimated from three or more non-coplanar 2D regions A three-dimensional numeric measurement that is approximate, based on three or more non-coplanar two-dimensional image regions.
121218 Volume estimated from two non-coplanar 2D regions A three-dimensional numeric measurement that is approximate, based on two non-coplanar two-dimensional image regions.
121219 Volume of bounding three dimensional region A three-dimensional numeric measurement of the bounding region of a three-dimensional region of interest in an image set.
121220 Volume of circumscribed sphere A three-dimensional numeric measurement of the bounding sphere of a three-dimensional region of interest in an image set.
121221 Volume of ellipsoid A three-dimensional numeric measurement of an ellipsoid shaped three-dimensional region of interest in an image set.
121222 Volume of sphere A three-dimensional numeric measurement of a sphere shaped three-dimensional region of interest in an image set.
121223 Arm of angle A line segment that is an arm of a pair of arms that defines an angle, whether or not those line segments share a common vertex.
121224 Acetabular angle The angle on an AP radiograph of the pelvis between a line drawn parallel to the acetabular roof and a line drawn horizontally through the inferior aspect of both triradiate cartilages (Hilgenreiner's line).
121225 Vector An entity that has both a magnitude and a direction.
121226 Approximate spatial location The approximate geometric location on an image or in space where an entity is located.
121227 Line segment length The length of that part of a line (a straight object having no curvature) that is bounded by two distinct end points and contains every point on the line between those two end points, including both of the two end points.
121230 Path Vertex Coordinates of a point on a defined path.
121231 Volume Surface Surface of an identified or measured volume.
121232 Source series for segmentation Series of image instances used as source data for a segmentation.
121233 Source image for segmentation Image instances used as source data for a segmentation.
121242 Distance from nipple Indicates the location of the area of interest as measured from the nipple of the breast.
121243 Distance from skin Indicates the location of the area of interest as measured from the most direct skin point of the breast.
121244 Distance from chest wall Indicates the location of the area of interest as measured from the chest wall.
121290 Patient exposure to ionizing radiation Patient exposure to ionizing radiation (procedure).
121291 Results communicated The act of communicating actionable findings to a responsible receiver.
121301 Simultaneous Doppler Reference is to a Doppler waveform acquired simultaneously with an image.
121302 Simultaneous Hemodynamic Reference is to a Hemodynamic waveform acquired simultaneously with an image.
121303 Simultaneous ECG Reference is to a ECG waveform acquired simultaneously with an image.
121304 Simultaneous Voice Narrative Reference is to a voice narrative recording acquired simultaneously with an image.
121305 Simultaneous Respiratory Waveform A waveform representing chest expansion and contraction due to respiratory activity, measured simultaneously with the acquisition of this Image.
121306 Simultaneous Arterial Pulse Waveform Arterial pulse waveform obtained simultaneously with acquisition of a referencing image.
121307 Simultaneous Phonocardiographic Waveform Phonocardiographic waveform obtained simultaneously with acquisition of a referencing image.
121310 RT treatment plan for the position being verified The referenced instance is an RT treatment plan of some type, which contains treatment positioning information, which has been verified using the information in the referencing instance.
121311 Localizer Image providing an anatomical reference on the patient under examination, for the purpose of defining the location of the ensuing imaging.
121312 Biopsy localizer Image providing an anatomical reference on the patient under examination, for the purpose of planning or documenting a biopsy.
121313 Other partial views Image providing a partial view of the target anatomy, when the target anatomy is too large for a single image.
121314 Other image of biplane pair Image providing a view of the target anatomy in a different imaging plane, typically from a near perpendicular angle.
121315 Other image of stereoscopic pair Image providing a view of the target anatomy in a different imaging plane, typically with a small angular difference.
121316 Images related to standalone object Image related to a non-image information object.
121317 Spectroscopy Image where signals are identified and separated according to their frequencies.
121318 Spectroscopy Data for Water Phase Correction MR spectroscopy data acquired to correct the phase of the diagnostic data for the phase signal of the Water.
121320 Uncompressed predecessor An image that has not already been lossy compressed that is used as the source for creation of a lossy compressed image.
121321 Mask image for image processing operation Image used as the mask for an image processing operation, such as subtraction.
121322 Source image for image processing operation Image used as the source for an image processing operation.
121323 Source series for image processing operation Series used as the source for an image processing operation.
121324 Source Image Image used as the source for a derived or compressed image.
121325 Lossy compressed image Image encoded with a lossy compression transfer syntax.
121326 Alternate SOP Class instance SOP Instance encoded with a different SOP Class but otherwise equivalent data.
121327 Full fidelity image Full fidelity image, uncompressed or lossless compressed.
121328 Alternate Photometric Interpretation image Image encoded with a different photometric interpretation.
121329 Source image for montage Image used as a source for a montage (stitched) image.
121330 Lossy compressed predecessor An image that has previously been lossy compressed that is used as the source for creation of another lossy compressed image.
121331 Equivalent CDA Document HL7 Document Architecture (CDA) Document that contains clinical content equivalent to the referencing Instance.
121332 Complete Rendering for Presentation Instance that contains a displayable complete rendering of the referencing Instance.
121333 Partial Rendering for Presentation Instance that contains a displayable partial rendering of the referencing Instance.
121334 Extended Rendering for Presentation Instance that contains a displayable complete rendering of the referencing Instance, plus additional content such as inline rendering of referenced images.
121335 Source Document Document whose content has been wholly or partially transformed to create the referencing document.
121338 Anatomic image Image showing structural anatomic features.
121339 Functional image Image showing physical or chemical activity.
121340 Spectral filtered image Image providing the same view of the target anatomy acquired using only a specific imaging wavelength, frequency or energy.
121341 Device localizer Image providing an anatomical reference on the patient under examination, for the purpose of documenting the location of device such as a diagnostic or therapeutic catheter.
121342 Dose Image Image providing a graphic view of the distribution of radiation dose.
121346 Acquisition frames corresponding to volume The referenced image is the source of spatially-related frames from which the referencing 3D volume data was derived.
121347 Volume corresponding to spatially-related acquisition frames 3D Volume containing the spatially-related frames in the referencing instance.
121348 Temporal Predecessor Instance acquired prior to the referencing instance in a set of consecutively acquired instances.
121349 Temporal Successor Instance acquired subsequent to the referencing instance in a set of consecutively acquired instances.
121350 Same acquisition at lower resolution Image of the same target area at lower resolution acquired in the same acquisition process.
121351 Same acquisition at higher resolution Image of the same target area at higher resolution acquired in the same acquisition process.
121352 Same acquisition at different focal depth Image of the same target area at different focal depth (Z-plane) acquired in the same acquisition process.
121353 Same acquisition at different spectral band Image of the same target area at different spectral band acquired in the same acquisition process.
121354 Imaged container label Image specifically targeting the container label.
121358 For Processing predecessor Source image from which FOR PRESENTATION images were created.
121360 Replaced report The reference is to a predecessor report that has been replaced by the current report.
121361 Addended report The reference is to a predecessor report to which the current report provides an addendum.
121362 Preliminary report A report that precedes the final report and may contain only limited information; it may be time sensitive, and it is not expected to contain all the reportable findings.
121363 Partial report A report that is not complete.
121370 Composed from prior doses The dose object created was calculated by summation of existing, previously calculated, RT Dose instances.
121371 Composed from prior doses and current plan The dose object created was calculated by summation of existing, previously calculated, RT Dose instances and dose newly calculated by the application. The newly calculated dose may or may not exist as an independent object.
121372 Source dose for composing current dose RT Dose Instances used as source for calculated dose.
121373 RT Pre-Treatment Dose Check An assessment of the dose delivery parameters performed before treatment.
121374 RT Pre-Treatment Consistency Check An assessment of consistency with a previously quality-assured treatment plan performed before treatment.
121375 Assessment By Comparison The basis of the assessment was a comparison object.
121376 Assessment By Rules The basis of the assessment was a set of rules on expected values, ranges and relationships.
121380 Active Ingredient Undiluted Concentration Concentration of the chemically or physically interesting (active) ingredient of a drug or contrast agent as delivered in product form from the manufacturer, typically in mg/ml.
121381 Contrast/Bolus Ingredient Opaque X-Ray absorption of the active ingredient of a contrast agent ingredient is greater than the absorption of water (tissue).
121382 Quantity administered Number of units of substance administered to a patient.
121383 Mass administered Mass of substance administered to a patient.
121384 RT Plan Label Human readable label of the radiotherapy plan.
121385 Current Fraction Number The index of the fraction of the radiotherapy plan to be delivered.
121386 Number of Fractions Planned The total number of prescribed radiotherapy fractions.
121387 Number of Fractions Completed The number of fully completed radiotherapy fractions of the radiotherapy plan to be delivered. Partially completed fractions are not included.
121388 Checked-In Status Whether or not the patient has been checked-in, i.e., are physically present and are waiting to be called in to the treatment room.
121389 Referenced Beam Number The referenced beam number within the radiotherapy plan to be delivered.
121401 Derivation Method of deriving or calculating a measured value.
121402 Normality Assessment of a measurement relative to a normal range of values; may be considered subtype of term (363713009, SCT, "has interpretation").
121403 Level of Significance Significance of a measurement.
121404 Selection Status Status of selection of a measurement for further processing or use.
121405 Population description Description of a population of measurements.
121406 Reference Authority Bibliographic or clinical reference for a Description of a population of measurements.
121407 Normal Range description Description of a normal range of values for a measurement concept.
121408 Normal Range Authority Bibliographic or clinical reference for a Description of a normal range of values.
121410 User chosen value Observation value selected by user for further processing or use, or as most representative.
121411 Most recent value chosen Observation value is the recently obtained, and has been selected for further processing or use.
121412 Mean value chosen Observation value is the mean of several measurements, and has been selected for further processing or use.
121414 Standard deviation of population Standard deviation of a measurement in a reference population.
121415 Percentile Ranking of measurement Percentile Ranking of an observation value with respect a reference population.
121416 Z-Score of measurement Z-score of an observation value with respect a reference population, expressed as the dimensionless quantity (x-m) /s, where (x-m) is the deviation of the observation value (x) from the population mean (m), and s is the standard deviation of the population.
121417 2 Sigma deviation of population 2 Sigma deviation of a measurement in a reference population.
121420 Equation Formula used to compute a derived measurement.
121421 Equation Citation Bibliographic reference to a formula used to compute a derived measurement; reference may be to a specific equation in a journal article.
121422 Table of Values Citation Bibliographic reference to a Table of Values used to look up a derived measurement.
121423 Method Citation Bibliographic reference to a method used to compute a derived measurement.
121424 Table of Values A Table of Values used to look up a derived measurement.
121425 Index Factor (divisor or multiplicand) for normalizing a measurement.
121427 Estimated Measurement obtained by observer estimation, rather than with a measurement tool or by calculation
121428 Calculated Measurement obtained by calculation
121430 Concern Identified issue about a state or process that has the potential to require intervention or management.
121431 DateTime Concern Noted DateTime concern noted (noted by whom is determined by context of use).
121432 DateTime Concern Resolved DateTime the concern was resolved.
121433 DateTime Problem Resolved DateTime the problem was resolved.
121434 Service Delivery Location Place at which healthcare services may be provided.
121435 Service Performer Identification of a healthcare provider who performed a healthcare service; may be either a person or an organization.
121436 Medical Device Used Type or identifier of a medical device used on, in, or by a patient.
121437 Pharmacologic and exercise stress test Cardiac stress test using pharmacologic and exercise stressors
121438 Paced stress test Cardiac stress test using an implanted or external cardiac pacing device
121439 Correction of congenital cardiovascular deformity Procedure for correction of congenital cardiovascular deformity
121701 RT Patient Setup Process of placing patient in the anticipated treatment position, including specification and location of positioning aids, and other treatment delivery accessories.
121702 RT Patient Position Acquisition, single plane MV Acquisition of patient positioning information, using single-plane megavoltage imaging.
121703 RT Patient Position Acquisition, dual plane MV Acquisition of patient positioning information, using dual-plane megavoltage imaging.
121704 RT Patient Position Acquisition, single plane kV Acquisition of patient positioning information, using single-plane kilovoltage imaging.
121705 RT Patient Position Acquisition, dual plane kV Acquisition of patient positioning information, using dual-plane kilovoltage imaging.
121706 RT Patient Position Acquisition, dual plane kV/MV Acquisition of patient positioning information, using dual-plane combination kilovoltage and megavoltage imaging.
121707 RT Patient Position Acquisition, CT kV Acquisition of patient positioning information, using kilovoltage CT imaging.This code encompasses both Cone-Beam CT and conventional CT.
121708 RT Patient Position Acquisition, CT MV Acquisition of patient positioning information, using megavoltage CT imaging.This code encompasses both Cone-Beam CT and conventional CT.
121709 RT Patient Position Acquisition, Optical Acquisition of patient positioning information, using optical imaging.
121710 RT Patient Position Acquisition, Ultrasound Acquisition of patient positioning information, using ultrasound imaging.
121711 RT Patient Position Acquisition, Spatial Fiducials Acquisition of patient positioning information, using spatial fiducials.
121712 RT Patient Position Registration, single plane Registration of intended and actual patient position prior to treatment delivery, using single-plane images.
121713 RT Patient Position Registration, dual plane Registration of intended and actual patient position prior to treatment delivery, using dual-plane images.
121714 RT Patient Position Registration, 3D CT general Registration of intended and actual patient position prior to treatment delivery, using 3D CT images and an unspecified registration approach.
121715 RT Patient Position Registration, 3D CT marker-based Registration of intended and actual patient position prior to treatment delivery, using 3D CT images and a marker-based registration approach.
121716 RT Patient Position Registration, 3D CT volume-based Registration of intended and actual patient position prior to treatment delivery, using 3D CT images and a volume-based registration approach.
121717 RT Patient Position Registration, 3D on 2D reference Registration of intended and actual patient position prior to treatment delivery, using 3D verification images and 2D reference images.
121718 RT Patient Position Registration, 2D on 3D reference Registration of intended and actual patient position prior to treatment delivery, using 2D verification images and 3D reference images.
121719 RT Patient Position Registration, Optical Registration of intended and actual patient position prior to treatment delivery, using optical images.
121720 RT Patient Position Registration, Ultrasound Registration of intended and actual patient position prior to treatment delivery, using ultrasound images.
121721 RT Patient Position Registration, Spatial Fiducials Registration of intended and actual patient position prior to treatment delivery, using spatial fiducials.
121722 RT Patient Position Adjustment Adjustment of patient position such that the patient is correctly positioned for treatment.
121723 RT Patient Position In-treatment-session Review Review of patient positioning information in the process of delivering a treatment session.
121724 RT Treatment Simulation with Internal Verification Simulated radiotherapy treatment delivery using verification integral to the Treatment Delivery System.
121725 RT Treatment Simulation with External Verification Simulated radiotherapy treatment delivery using verification by a external Machine Parameter Verifier.
121726 RT Treatment with Internal Verification Radiotherapy treatment delivery using verification integral to the Treatment Delivery System.
121727 RT Treatment with External Verification Radiotherapy treatment delivery using verification by a external Machine Parameter Verifier.
121728 RT Treatment QA with Internal Verification Quality assurance of a radiotherapy treatment delivery using verification integral to the Treatment Delivery System.
121729 RT Treatment QA with External Verification Quality assurance of a radiotherapy treatment delivery using verification by a external Machine Parameter Verifier.
121730 RT Machine QA Quality assurance of a Treatment Delivery Device.
121731 RT Treatment QA by RT Plan Dose Check Perform Quality Assurance on an RT Plan by evaluating dosimetric content of the current RT Plan.
121732 RT Treatment QA by RT Plan Difference Check Perform Quality Assurance on an RT Plan by comparing the content of previously quality-assessed RT Plans with the current RT Plan.
121733 RT Treatment QA by RT Ion Plan Dose Check Perform Quality Assurance on an RT Ion Plan by evaluating dosimetric content of the current RT Ion Plan.
121734 RT Treatment QA with RT Ion Plan Difference Check Perform Quality Assurance on an RT Ion Plan by comparing the content of previously quality-assessed RT Ion Plans by the current RT Ion Plan.
121735 RT Brachy Treatment Brachytherapy Treatment Delivery.
121740 Treatment Delivery Type Indicates whether the treatment to be delivered is a complete fraction or a continuation of previous incompletely treated fraction.
122001 Patient called to procedure room Patient called to procedure room.
122002 Patient admitted to procedure room Patient admitted to procedure room.
122003 Patient given pre-procedure instruction Patient given pre-procedure instruction.
122004 Patient informed consent given Patient informed consent given.
122005 Patient advance directive given Patient advance directive given.
122006 Nil Per Os (NPO) status confirmed Nil Per Os (NPO) status confirmed.
122007 Patient assisted to table Patient assisted to table.
122008 Patient prepped and draped Patient prepped and draped.
122009 Patient connected to continuous monitoring Patient connected to continuous monitoring.
122010 Patient transferred to holding area Patient transferred to holding area.
122011 Patient transferred to surgery Patient transferred to surgery.
122012 Patient transferred to CCU Patient transferred to CCU.
122020 Patient disoriented Patient disoriented.
122021 Patient reports nausea Patient reports nausea.
122022 Patient reports discomfort Patient reports discomfort.
122023 Patient reports chest pain Patient reports chest pain.
122024 Patient reports no pain Patient reports no pain.
122025 Patient alert Patient alert.
122026 Patient restless Patient restless.
122027 Patient sedated Patient sedated.
122028 Patient asleep Patient asleep.
122029 Patient unresponsive Patient unresponsive.
122030 Patient has respiratory difficulty Patient has respiratory difficulty.
122031 Patient coughed Patient coughed.
122032 Patient disconnected from continuous monitoring Patient disconnected from continuous monitoring.
122033 Hemostasis achieved Hemostasis achieved.
122034 Hemostasis not achieved - oozing Hemostasis not achieved - oozing.
122035 Hemostasis not achieved - actively bleeding Hemostasis not achieved - actively bleeding.
122036 Patient given post-procedure instruction Patient given post-procedure instruction.
122037 Patient discharged from department Patient discharged from department or laboratory.
122038 Patient pronounced dead Patient pronounced dead.
122039 Patient transferred to morgue Patient transferred to morgue.
122041 Personnel Arrived Identified personnel or staff arrived in procedure room.
122042 Personnel Departed Identified personnel or staff departed procedure room.
122043 Page Sent To Page sent to identified personnel or staff.
122044 Consultation With Consultation with identified personnel or staff.
122045 Office called Office of identified personnel or staff was called.
122046 Equipment failure Equipment failure
122047 Equipment brought to procedure room Equipment brought to procedure room.
122048 Equipment ready Equipment ready for procedure.
122049 Equipment removed Equipment removed from procedure room.
122052 Bioptome Device for obtaining biopsy sample.
122053 Valvular Intervention Valvular Intervention.
122054 Aortic Intervention Aortic Intervention.
122055 Septal Defect Intervention Septal Defect Intervention.
122056 Vascular Intervention Vascular Intervention.
122057 Myocardial biopsy Myocardial biopsy.
122058 Arterial conduit angiography Arterial conduit angiography.
122059 Single plane Angiography Single plane Angiography.
122060 Bi-plane Angiography Bi-plane Angiography.
122061 Percutaneous Coronary Intervention Percutaneous Coronary Intervention.
122062 15-Lead ECG 15-Lead electrocardiography
122072 Pre-procedure log Log of events occurring prior to the current procedure.
122073 Current procedure evidence Analysis or measurements for current procedure (purpose of reference to evidence document).
122075 Prior report for current patient Prior report for current patient.
122076 Consumable taken from inventory Identifier of Consumable taken from inventory.
122077 Consumable returned to inventory Identifier of Consumable returned to inventory.
122078 Remaining consumable disposed Identifier of consumable whose remaining content has been disposed.
122079 Consumable unusable Identifier of Consumable determined to be unusable.
122081 Drug start Identifier of Drug whose administration has started.
122082 Drug end Identifier of Drug whose administration has ended.
122083 Drug administered Identifier of Drug administered as part of procedure.
122084 Contrast start Identifier of Contrast agent whose administration has started.
122085 Contrast end Identifier of Contrast agent whose administration has ended.
122086 Contrast administered Identifier of Contrast agent administered.
122087 Infusate start Identifier of Infusate whose administration has started.
122088 Infusate end Identifier of Infusate whose administration has ended.
122089 Device crossed lesion Action of a device traversing a vascular lesion.
122090 Intervention Action Action of a clinical professional performed on a patient for therapeutic purpose.
122091 Volume administered Volume of Drug, Contrast agent, or Infusate administered.
122092 Undiluted dose administered Undiluted dose of Drug, Contrast agent, or Infusate administered.
122093 Concentration Concentration of Drug, Contrast agent, or Infusate administered.
122094 Rate of administration Rate of Drug, Contrast agent, or Infusate administration.
122095 Duration of administration Duration of Drug, Contrast agent, or Infusate administration.
122096 Volume unadministered or discarded Volume of Drug, Contrast agent, or Infusate unadministered or discarded.
122097 Catheter Curve Numeric parameter of Curvature of Catheter.
122098 Transmit Frequency Transmit Frequency.
122099 ST change from baseline Measured change of patient electrocardiographic ST level relative to baseline measurement.
122101 Aneurysm on cited vessel Anatomic term modifier indicating aneurysm on cited vessel is the subject of the finding.
122102 Graft to cited segment, proximal section Anatomic term modifier indicating proximal section of graft to cited vessel is the subject of the finding.
122103 Graft to cited segment, mid section Anatomic term modifier indicating mid section of graft to cited vessel is the subject of the finding.
122104 Graft to cited segment, distal section Anatomic term modifier indicating distal section of graft to cited vessel is the subject of the finding.
122105 DateTime of Intervention DateTime of Intervention.
122106 Duration of Intervention Duration of Intervention.
122107 Baseline Stenosis Measurement Lesion stenosis measured prior to any interventional procedure
122108 Post-Intervention Stenosis Measurement Lesion stenosis measured after an interventional procedure
122109 Baseline TIMI Flow Assessment of perfusion across a coronary lesion measured prior to any interventional procedure.
122110 Post-Intervention TIMI Flow Assessment of perfusion across a coronary lesion measured after an interventional procedure.
122111 Primary Intervention Device Indication that device is the primary (first and/or most significant) device used for interventional therapy of a particular pathology.
122112 Normal Myocardium Normal Myocardium.
122113 Scarred Myocardium Scarred Myocardium.
122114 Thinning Myocardium Thinning Myocardium.
122120 Hemodynamics Report Hemodynamics Report.
122121 Atrial pressure measurements Atrial pressure measurements, report section.
122122 Ventricular pressure measurements Ventricular pressure measurements, report section.
122123 Gradient assessment Gradient assessment, report section.
122124 Blood velocity measurements Blood velocity measurements, report section.
122125 Blood lab measurements Blood lab measurements, report section.
122126 Derived Hemodynamic Measurements Derived Hemodynamic Measurements, report section.
122127 Clinical Context Clinical Context, report section.
122128 Patient Transferred From Location from which the patient was transferred.
122129 PCI during this procedure Indication that the procedure includes a percutaneous coronary intervention.
122130 Dose Area Product Radiation dose times area of exposure.
122131 Degree of Thrombus Finding of probability and/or severity of thrombus.
122132 Severity of Calcification Severity of Calcification, property of lesion.
122133 Lesion Morphology Lesion Morphology; form and/or structural properties of lesion.
122134 Vessel Morphology Vessel Morphology; form and/or structural properties of vessel.
122138 Circulatory Support Technique (device or procedure) of support for patient circulatory system; hemodynamic support.
122139 Reason for Study Reason for Study.
122140 Comparison with Prior Study Done Indication that the current study data has been compared with prior study data.
122141 Electrode Placement Electrocardiographic electrode placement technique.
122142 Acquisition Device Type Acquisition Device Type.
122143 Acquisition Device ID Acquisition Device ID.
122144 Quantitative Analysis Quantitative Analysis, report section.
122145 Qualitative Analysis Qualitative Analysis, report section.
122146 Procedure DateTime The date and time on which a procedure was performed on a patient.
122147 Clinical Interpretation Clinical Interpretation, report section.
122148 Lead ID ECG Lead Identifier.
122149 Beat Number Beat Number; ordinal of cardiac cycle within an acquisition.
122150 Compound Statement Complex coded semantic unit, consisting of several coded components.
122151 Trend Trend (temporal progression) of a clinical condition, finding, or disease.
122152 Statement Coded semantic unit.
122153 Statement Modifier Coded modifier for a semantic unit.
122154 Conjunctive Term Conjunctive term between semantic units.
122157 Probability Probability.
122158 ECG Global Measurements ECG Global Measurements, report section.
122159 ECG Lead Measurements ECG Lead Measurements, report section.
122160 Derived Area, Non-Valve Derived cross-sectional area of a vessel or anatomic feature, other than a cardiac valve.
122161 Pulmonary Flow Rate of blood flow through Pulmonary artery.
122162 Systemic Flow Rate of blood flow through the aorta.
122163 Discharge DateTime DateTime of patient discharge from hospital admission.
122164 Coronary Artery Bypass During This Admission Indication that a Coronary Artery Bypass operation was performed during the current hospital admission.
122165 DateTime of Death DateTime of Death.
122166 Death During This Admission Indication that the patient died during the current hospital admission.
122167 Death During Catheterization Indication that the patient died during the current Catheterization procedure.
122170 Type of Myocardial Infarction Finding of type of Myocardial Infarction.
122171 Coronary lesion > = 50% stenosis Finding of Coronary lesion with greater than 50% stenosis.
122172 Acute MI Present Finding of Acute Myocardial Infarction Presence as indication for interventional procedure.
122173 ST Elevation Onset DateTime DateTime of first determination of elevated ECG ST segment, as indication of Myocardial Infarction.
122175 Number of lesion interventions attempted Number of lesion interventions attempted during current procedure.
122176 Number of lesion interventions successful Number of lesion interventions successful during current procedure, where the residual post intervention stenosis is less than or equal to 50% of the arterial luminal diameter, TIMI Flow is 3 and the minimal decrease in stenosis was 20%.
122177 Procedure Result Overall success of interventional procedure.
122178 Lesion Intervention Information Lesion Intervention Information, report section.
122179 Peri-procedural MI occurred Indication that Myocardial Infarction occurred during current procedure.
122180 CK-MB baseline Creatine Kinase-MB value at baseline (start of procedure).
122181 CK-MB peak Creatine Kinase-MB highest value measured during procedure.
122182 R-R interval Time interval between ECG R-wave peaks in subsequent cardiac cycles.
122183 Blood temperature Blood temperature.
122185 Blood Oxygen content Blood Oxygen content.
122187 Blood Carbon dioxide saturation Blood Carbon dioxide saturation.
122188 Pulmonary Arterial Content (FCpa) Pulmonary Arterial Content (FCpa).
122189 Pulmonary Venous Content (FCpv) Pulmonary Venous Content (FCpv).
122190 Max dp/dt/P Max dp/dt/P.
122191 Ventricular End Diastolic pressure Ventricular End Diastolic pressure.
122192 Indicator appearance time Elapsed time from injection of an indicator bolus until it is observed at another location.
122193 Maximum pressure acceleration Maximum pressure acceleration.
122194 Ventricular Systolic blood pressure Ventricular Systolic blood pressure.
122195 Pulse Strength Pulse Strength; palpable strength of systolic flow.
122196 C wave pressure The secondary peak pressure in the atrium during atrial contraction.
122197 Gradient pressure, average Gradient pressure, average.
122198 Gradient pressure, peak Gradient pressure, peak.
122199 Pressure at dp/dt max Pressure at dp/dt max.
122201 Diastolic blood velocity, mean Diastolic blood velocity, mean.
122202 Diastolic blood velocity, peak Diastolic blood velocity, peak.
122203 Systolic blood velocity, mean Systolic blood velocity, mean.
122204 Systolic blood velocity, peak Systolic blood velocity, peak.
122205 Blood velocity, mean Blood velocity, mean.
122206 Blood velocity, minimum Blood velocity, minimum.
122207 Blood velocity, peak Blood velocity, peak.
122208 x-descent pressure Venous or atrial pressure minimum during ventricular systole, after A-wave.
122209 y-descent pressure Venous or atrial pressure minimum when tricuspid valve opens during diastole, after V-wave.
122210 z-point pressure Atrial pressure upon closure of tricuspid and mitral valves.
122211 Left Ventricular ejection time Left Ventricular ejection time.
122212 Left Ventricular filling time Left Ventricular filling time.
122213 Right Ventricular ejection time Right Ventricular ejection time.
122214 Right Ventricular filling time Right Ventricular filling time.
122215 Total Pulmonary Resistance Total Pulmonary Resistance.
122216 Total Vascular Resistance Total Vascular Resistance.
122217 Coronary Flow reserve Coronary Flow reserve.
122218 Diastolic/Systolic velocity ratio Diastolic/Systolic velocity ratio.
122219 Hyperemic ratio Hyperemic ratio.
122220 Hemodynamic Resistance Index Hemodynamic Resistance Index.
122221 Thorax diameter, sagittal Thorax diameter, sagittal.
122222 Procedure Environmental Characteristics Environmental characteristics in the procedure room.
122223 Room oxygen concentration Oxygen concentration in the procedure room.
122224 Room temperature Temperature in the procedure room.
122225 Room Barometric pressure Barometric pressure in the procedure room.
122227 Left to Right Flow Left to Right Flow.
122228 Right to Left Flow Right to Left Flow.
122229 Arteriovenous difference Arteriovenous oxygen content difference.
122230 10 Year CHD Risk Framingham Study 10 Year CHD Risk.
122231 Comparative Average10 Year CHD Risk Framingham Study Comparative Average10 Year CHD Risk.
122232 Comparative Low10 Year CHD Risk Framingham Study Comparative Low10 Year CHD Risk.
122233 LDL Cholesterol Score Sheet for Men Framingham Study LDL Cholesterol Score Sheet for Men.
122234 LDL Cholesterol Score Sheet for Women Framingham Study LDL Cholesterol Score Sheet for Women.
122235 Total Cholesterol Score Sheet for Men Framingham Study Total Cholesterol Score Sheet for Men.
122236 Total Cholesterol Score Sheet for Women Framingham Study Total Cholesterol Score Sheet for Women.
122237 Corrected Sinus Node Recovery Time Corrected Sinus Node Recovery Time.
122238 Max volume normalized to 50mmHg pulse pressure Max volume normalized to 50mmHg pulse pressure.
122239 Oxygen Consumption Oxygen Consumption.
122240 BSA = 0.003207*WT^(0.7285-0.0188​*log(WT))*HT^0.3 Body Surface Area computed from patient height and weight: BSA = 0.003207*WT[g]^(0.7285-0.0188​​*log(WT[g]))*HT[cm]^0.3 [Boyd E, The growth of the surface area of the human body. Minneapolis: University of Minnesota Press, 1935, eq. (36) ].
122241 BSA = 0.007184*WT^0.425​*HT^0.725 Body Surface Area computed from patient height and weight: BSA = 0.007184*WT[kg]^0.425​*HT[cm]^0.725 [Dubois and Dubois, Arch Int Med 1916 17:863-71].
122242 BSA = 0.0235*WT^0.51456​*HT^0.42246 Body Surface Area computed from patient height and weight: BSA = 0.0235*WT[kg]^0.51456​​*HT[cm]^0.42246[Gehan EA, George SL, 'Estimation of human body surface area from height and weight', Cancer Chemother Rep 1970 54:225-35].
122243 BSA = 0.024265*WT^0.5378​*HT^0.3964 Body Surface Area computed from patient height and weight: BSA = 0.024265*WT[kg]^0.5378​*HT[cm]^0.3964[Haycock G.B., Schwartz G.J., Wisotsky D.H. 'Geometric method for measuring body surface area: A height weight formula validated in infants, children and adults.' The Journal of Pediatrics 1978 93:1:62-66].
122244 BSA = (HT*WT/36)^0.5 Body Surface Area computed from patient height and weight: BSA = (HT[m]*WT[kg]/36)^0.5[Mosteller, R.D. 'Simplified Calculation of Body Surface Area.' N Engl J Med 1987 Oct 22;317(17):1098].
122245 BSA = 1321+0.3433*WT Body Surface Area computed from patient weight:BSA = 1321 + 0.3433 * WT[kg] (for pediatrics 3-30 kg) [Current, J.D. 'A Linear Equation For Estimating The Body Surface Area In Infants And Children', The Internet Journal of Anesthesiology. 1998. 2:2].
122246 BSA = 0.0004688*WT^(0.8168-0.0154​*log(WT)) BSA = 0.0004688*(1000*WT)^(0.8168-0.0154​*log(1000*WT))Where (WT is weight in kilogram)Units = m2Boyd, Edith. The Growth of the Surface Area of the Human Body(originally published in 1935 by the University of Minnesota Press), Greenwood Press, Westport, Connecticut, 1975, p. 102.Equation (35).
122247 VO2male = BSA (138.1 - 11.49 * loge(age) + 0.378 * HRf) Equation for estimated oxygen consumption: VO2male = BSA (138.1 - 11.49 * loge(age) + 0.378 * HRf).
122248 VO2female = BSA (138.1 - 17.04 * loge(age) + 0.378 * HRf) Equation for estimated oxygen consumption: VO2female = BSA (138.1 - 17.04 * loge(age) + 0.378 * HRf).
122249 VO2 = VeSTPD * 10 * (FIO2 - FE02) Equation for estimated oxygen consumption: VO2 = VeSTPD * 10 * (FIO2 - FE02).
122250 VO2 = 152 * BSA Equation for estimated oxygen consumption: VO2 = 152 * BSA.
122251 VO2 = 175 * BSA Equation for estimated oxygen consumption: VO2 = 175 * BSA.
122252 VO2 = 176 * BSA Equation for estimated oxygen consumption: VO2 = 176 * BSA.
122253 Robertson & Reid table Robertson & Reid Table for estimated oxygen consumption.
122254 Fleisch table Fleisch table for estimated oxygen consumption.
122255 Boothby table Boothby table for estimated oxygen consumption.
122256 if (prem age< 3days) P50 = 19.9 Estimate of Oxygen partial pressure at 50% saturation for premature infants less than 3 days old: P50 = 19.9.
122257 if (age < 1day) P50 = 21.6 Estimate of Oxygen partial pressure at 50% saturation for infants less than 1 day old: P50 = 21.6.
122258 if (age < 30day) P50 = 24.6 Estimate of Oxygen partial pressure at 50% saturation for infants less than 30 days old: P50 = 24.6.
122259 if (age < 18y) P50 = 27.2 Estimate of Oxygen partial pressure at 50% saturation for patients less than 18 years old: P50 = 27.2.
122260 if (age < 40y) P50 = 27.4 Estimate of Oxygen partial pressure at 50% saturation for patients less than 40 years old: P50 = 27.4.
122261 if (age > 60y) P50 = 29.3 Estimate of Oxygen partial pressure at 50% saturation for patients more than 60 years old: P50 = 29.3.
122262 Area = Flow / 44.5 * sqrt(Gradient[mmHg]) Cardiac valve area computed from flow and pressure gradient: Area = Flow / 44.5 * sqrt(Gradient[mmHg]) [Gorlin and Gorlin, Am Heart J, 1951].
122263 MVA = Flow / 38.0 * sqrt(Gradient[mmHg]) Mitral valve area computed from flow and pressure gradient: Mitral valve Area = Flow / 38.0 * sqrt(Gradient[mmHg]) [Gorlin and Gorlin, Am Heart J, 1951].
122265 BMI = Wt / Ht ^ 2 Body Mass Index computed from weight and height: BMI = Wt/Ht^2.
122266 BSA = 0.007358*WT^0.425​*HT^0.725 Body Surface Area computed from patient height and weight: BSA = 0.007358*WT[kg]^0.425​*HT[cm]^0.725(for East Asian adult, aged 15+ years) [Kanai Izumi, Masamitsu Kanai, 'Clinical examination method summary'].
122267 BSA = 0.010265*WT^0.423​*HT^0.651 Body Surface Area computed from patient height and weight: BSA = 0.010265*WT[kg]^0.423​*HT[cm]^0.651 (For East Asian child aged 12-14 years).
122268 BSA = 0.008883*WT^0.444​*HT^0.663 Body Surface Area computed from patient height and weight: BSA = 0.008883*WT[kg]^0.444​*HT[cm]^0.663 (For East Asian child aged 6-11 years).
122269 BSA = 0.038189*WT^0.423​*HT^0.362 Body Surface Area computed from patient height and weight: BSA = 0.038189*WT[kg]^0.423​*HT[cm]^0.362 (For East Asian child aged 1-5 years).
122270 BSA = 0.009568*WT^0.473​*HT^0.655 Body Surface Area computed from patient height and weight: BSA = 0.009568*WT[kg]^0.473​*HT[cm]^0.655 (For East Asian child aged 0-12 months).
122271 Skin Condition Warm Skin Condition Warm.
122272 Skin Condition Cool Skin Condition Cool.
122273 Skin Condition Cold Skin Condition Cold.
122274 Skin Condition Dry Skin Condition Dry.
122275 Skin Condition Clammy Skin Condition Clammy.
122276 Skin Condition Diaphoretic Skin Condition Diaphoretic.
122277 Skin Condition Flush Skin Condition Flush.
122278 Skin Condition Mottled Skin Condition Mottled.
122279 Skin Condition Pale Skin Condition Pale.
122281 Airway unobstructed Airway unobstructed.
122282 Airway partially obstructed Airway partially obstructed.
122283 Airway severely obstructed Airway severely obstructed.
122288 Not Visualized Anatomy could not be visualized for the purpose of evaluation.
122291 Quantitative Arteriography Report Quantitative Arteriography Report.
122292 Quantitative Ventriculography Report Quantitative Ventriculography Report.
122301 Guidewire crossing lesion unsuccessful Guidewire crossing lesion unsuccessful.
122302 Guidewire crossing lesion successful Guidewire crossing lesion successful.
122303 Angioplasty balloon inflated Angioplasty balloon inflated.
122304 Angioplasty balloon deflated Angioplasty balloon deflated.
122305 Device deployed Device deployed.
122306 Stent re-expanded Stent re-expanded.
122307 Object removed Object removed.
122308 Radiation applied Radiation applied.
122309 Radiation removed Radiation removed.
122310 Interventional device placement unsuccessful Interventional device placement unsuccessful.
122311 Interventional device placed Interventional device placed.
122312 Intervention performed Intervention performed.
122313 Interventional device withdrawn Interventional device withdrawn.
122319 Catheter Size Catheter Size.
122320 Injectate Temperature Injectate Temperature.
122321 Injectate Volume Injectate Volume.
122322 Calibration Factor Factor by which a measured or calculated value is multiplied to obtain the estimated real-world value.
122325 IVUS Report Intravascular Ultrasound Report.
122330 EEM Diameter External Elastic Membrane (EEM) diameter measured through the center point of the vessel. Center point of the vessel is defined as the center of gravity of the EEM area. The EEM is a discrete interface at the border between the media and the adventitia.
122331 Plaque Plus Media Thickness The distance from intimal leading edge to the external elastic membrane along any line passing through the luminal center, which is defined as the center of gravity of the lumen area.
122332 Lumen Perimeter Planimetered perimeter of the lumen.
122333 EEM Cross-Sectional Area Vessel area measured at the External Elastic Membrane (EEM), a discrete interface at the border between the media and the adventitia.
122334 Plaque plus Media Cross-Sectional Area Area within the EEM occupied by atheroma, regardless of lumen compromise. Plaque plus Media Area = EEM cross-sectional area - vessel lumen cross-sectional area.
122335 In-Stent Neointimal Cross-Sectional Area Measurement of in-stent restenosis. In-Stent Intimal Area = Stent cross-sectional area - vessel lumen cross-sectional area.
122336 Vascular Volume measurement length Longitudinal extent of the Vascular Volume Measurement. This is the distance from the distal edge to the proximal edge of the Volume measurement.
122337 Relative position Longitudinal distance from the closest edge of a fiducial feature or reference location to the start of the vascular measurement. This value will be a positive if the measurement is distal to the fiducial feature or reference location, or negative if the measurement is proximal to the fiducial feature or reference location.
122339 Stent Volume Obstruction In-Stent Neointimal Volume / Stent Volume.
122340 Fiducial feature Reference, normally anatomical, which is used for locating the position of a measurement.
122341 Calcium Length Longitudinal calcium length measurement.
122343 Lumen Eccentricity Index Measurement of vessel lumen eccentricity. Lumen Eccentricity Index = (maximum vessel lumen diameter - minimum vessel lumen diameter) / maximum vessel lumen diameter. Lumen diameters are measured through the center point of the lumen, which is defined as the center of gravity of the lumen area.
122344 Plaque plus Media Eccentricity Index Plaque plus Media Eccentricity Index = (maximum Plaque plus media thickness - minimum Plaque plus media thickness) / maximum Plaque plus media thickness.
122345 Remodeling Index Measurement of increase or decrease in EEM area that occurs during the development of atherosclerosis. Remodeling Index = Lesion EEM area / reference EEM area.
122346 Stent Symmetry Index Measurement of stent circularity. Stent Symmetry Index = (maximum stent diameter - minimum stent diameter) / maximum stent diameter.
122347 Stent Expansion Index Measurement of stent area relative to the reference lumen area. Stent Expansion Index = Minimum stent area / reference vessel lumen cross-sectional area.
122348 Lumen Shape Index Measurement of vessel lumen eccentricity. Lumen Shape Index = (2p * sqrt(Vessel lumen cross-sectional area / p) / Lumen Perimeter) 2Reference: Tobis & Yock, "Intravascular Ultrasound Imaging", Chapter 7.
122350 Lumen Diameter Ratio Lumen diameter ratio = minimum vessel lumen diameter / maximum vessel lumen diameter, measured at the same cross section in the vessel. Lumen diameters are measured through the center point of the lumen, which is defined as the center of gravity of the lumen area.
122351 Stent Diameter Ratio Stent diameter ratio = Minimum stent diameter / Maximum stent diameter, measured at the same cross section in the vessel. Stent diameters are measured through the center point of the stent, which is defined as the center of gravity of the stent area.
122352 EEM Diameter Ratio EEM diameter ratio = minimum EEM diameter / maximum EEM diameter. Measured at the same cross section in the vessel.
122354 Plaque Burden Fractional area within the External Elastic Membrane (EEM) occupied by atheroma. Plaque Burden = (EEM area - vessel lumen cross-sectional area) / EEM area.
122355 Arc of Calcium Angular measurement of a Calcium deposit with the apex located at the center of the lumen, which is defined as the center of gravity of the lumen area.
122356 Soft plaque Plaque characterized by low density or echogenicity.
122357 In-Stent Neointima Abnormal thickening of the intima within the stented segment.
122360 True Lumen Lumen surrounded by all three layers of the vessel-intima, media, and adventitia.
122361 False Lumen A channel, usually parallel to the true lumen, which does not communicate with the true lumen over a portion of its length.
122363 Plaque Rupture Plaque ulceration with a tear detected in a fibrous cap.
122364 Stent Gap Length of gap between two consecutive stents.
122367 T-1 Worst Worst stenosis - the stenosis with the smallest lumen size within a vessel segment.
122368 T-2 Secondary 2nd most severe stenosis within a vessel segment.
122369 T-3 Secondary 3rd most severe stenosis within a vessel segment.
122370 T-4 Secondary 4th most severe stenosis within a vessel segment.
122371 EEM Volume External Elastic Membrane (EEM) volume measured within a specified region. The EEM is a discrete interface at the border between the media and the Adventitia.
122372 Lumen Volume Lumen volume measured within a specified region.
122374 In-Stent Neointimal Volume The amount of plaque between the lumen and stent, within the stent region; In-stent restenosis. In-Stent Neointimal Volume = Stent Volume - Lumen Volume.
122375 Native Plaque Volume The amount of plaque between the stent and the EEM, within the stent region. Native Plaque Volume = EEM Volume - Stent Volume.
122376 Total Plaque Volume Total amount of plaque between the EEM and the Lumen, over the entire region that is measured. Total Plaque Volume = EEM Volume - Lumen Volume.
122380 Proximal Reference Proximal reference segment measurement site. Typically the site with the largest lumen proximal to a stenosis but within the same segment (usually within 10 mm of the stenosis with no major intervening branches).
122381 Distal Reference Distal reference segment measurement site. Typically the site with the largest lumen distal to a stenosis but within the same segment (usually within 10 mm of the stenosis with no major intervening branches).
122382 Site of Lumen Minimum Site of the smallest lumen in a vessel.
122383 Entire Pullback Measurement region that encompasses the entire vessel imaged in a single pullback acquisition.
122384 Stented Region Measurement region occupied by the stent.
122385 Proximal Stent Margin Region starting at the proximal edge of the Stent and extending several millimeters (usually 5 mm) proximal to the Stent edge.
122386 Distal Stent Margin Region starting at the distal edge of the Stent and extending several millimeters (usually 5 mm) distal to the Stent edge.
122387 Dissection Classification Classification of dissections in a vessel.
122388 Intra-stent Dissection Separation of neointimal hyperplasia from stent struts, usually seen only after treatment of in-stent restenosis.
122389 Vulnerable Plaque Plaque with a thin cap fibrous atheroma that is at increased risk of rupture and thrombosis (or re-thrombosis) and rapid stenosis progression.
122390 Eroded Plaque Plaque erosions with no structural defect (beyond endothelial injury) or gap in the plaque.
122391 Relative Stenosis Severity Stenosis severity classifications of multiple lesions in a vessel.
122393 Restenotic Lesion A finding of a previously treated lesion in which stenosis has reoccurred.
122394 Fibro-Lipidic Plaque Loosely packed bundles of collagen fibers with regions of lipid deposition present. Region is cellular and no cholesterol clefts or necrosis are present. Somemacrophage infiltration. Increase in extra cellular matrix.
122395 Necrotic-Lipidic Plaque Area within the plaque with very low echogenicity separated from the lumen and surrounded by more echogenic structures (fibrous cap). Highly lipidic necrotic region with remnants of foam cells and dead lymphocytes present. No collagen fibers are visible and mechanical integrity is poor. Cholesterol clefts and micro calcifications are visible.
122397 Adventitial Dissection Separation of the layers of an artery involving the adventitia
122398 Intimal Dissection Separation of the layers of an artery involving the intima. Dissection limited to the intima or atheroma, and not extending to the media.
122399 Medial Dissection Separation of the layers of an artery involving the media. Dissection in the arterial Media, extending into the media.
122400 Simultaneously Acquired The referenced information was acquired simultaneously with the information in the object in which the reference occurs.
122401 Same Anatomy Information acquired for the same anatomic region.
122402 Same Indication Information acquired for the same indication.
122403 For Attenuation Correction The referenced information was used to correct the data for differential attenuation through different anatomic tissue.
122404 Reconstructed Value estimated for a vessel in the absence of a stenosis.
122405 Algorithm Manufacturer Manufacturer of application used.
122406 Left Atrial Ejection Fraction by Angiography Left Atrial Ejection Fraction by Angiography.
122407 Left Atrial ED Volume Left Atrial End Diastolic Volume.
122408 Left Atrial ES Volume Left Atrial End Systolic Volume.
122410 Contour Realignment Contour repositioning of End Diastolic relative to End Systolic contour.
122411 Threshold Value The minimum standard deviation to define the hypokinesis and hyperkinesis.
122417 Regional Abnormal Wall Motion Report of differentiation of wall motion compared to normal.
122421 Calibration Object Object used for Calibration.
122422 Calibration Method Method used for Calibration.
122423 Calibration Object Size Size of calibration object.
122428 Area Length Method Method how long axis is positioned.
122429 Volume Method Model for cardiac chamber volume calculation.
122430 Reference Method Method to define original diameter of the artery.
122431 Regression Slope ED Relation between calculated End Diastolic volume and ventricular End Diastolic volume. The specific meaning is dependent on volume method used.
122432 Regression Offset ED Correction factor for the calculated End Diastolic volume and ventricular End Diastolic volume. The specific meaning is dependent on volume method used.
122433 Regression Slope ES Relation between calculated End Systolic volume and ventricular End Systolic volume. The specific meaning is dependent on volume method used.
122434 Regression Offset ES Correction factor for the calculated End Systolic volume and ventricular End Systolic volume. The specific meaning is dependent on volume method used.
122435 Regression Volume Exponent Exponent of volume in regression formula.
122438 Reference Points Container for spatial locations or coordinates used for calculation.
122445 Wall Thickness Average thickness of the chamber wall in the current view.
122446 Wall Volume Volume of the chamber wall estimated from the current view.
122447 Wall Mass Mass of the chamber wall (myocardium).
122448 Wall Stress Peak systolic stress of chamber wall.
122449 Centerline Wall Motion Analysis Method to calculate wall motion [example: Sheehan, 1986].
122450 Normalized Chord Length The length between End Diastolic and End Systolic contour perpendicular on the centerline normalized by a method dependent ventricular perimeter length. The centerline is the line equidistant between the End Diastolic and End Systolic contour [example: Sheehan, 1986].
122451 Abnormal Region The report of the boundaries of the abnormal (hyperkinetic, hypokinetic, a-kinetic) regions associated with the territory of the artery [example: Sheehan, 1986].
122452 First Chord of Abnormal Region The chord number specifying the begin of abnormal region [example: Sheehan, 1986].
122453 Last Chord of Abnormal Region The chord number specifying the end of abnormal region [example: Sheehan, 1986].
122459 Territory Region Severity Severity at the regional abnormality extent [example: Sheehan, 1986].
122461 Opposite Region Severity Severity at the opposite regional abnormality extent [example: Sheehan, 1986].
122464 LAD Region in RAO Projection Based on a total number of chords of 100 and RAO project the range of chords belonging to this circumferential extent lies between 5 - 85. [Sheehan, 1986].
122465 RCA Region in ROA Projection Based on a total number of chords of 100 and RAO project the range of chords belonging to this circumferential extent lies between 25 - 85. [Sheehan, 1986].
122466 Single LAD Region in RAO Projection Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 10 - 66 (hypokinetic) and 67 - 80 (hyperkinetic). [Sheehan, 1986].
122467 Single RCA Region in RAO Projection Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 51 - 80 (hypokinetic) and 10 - 50 (hyperkinetic). [Sheehan, 1986].
122468 Multiple LAD Region in RAO Projection Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 10 - 58 (hypokinetic) and 59 -80 (hyperkinetic). [Sheehan, 1986].
122469 Multiple RCA Region in RAO Projection Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 59 - 80 (hypokinetic) and 10 - 58 (hyperkinetic). [Sheehan, 1986].
122470 LAD Region in LAO Projection Based on a total number of chords of 100 and LAO projection the range of chords belonging to this regional extent lies between 50 -100 (hypokinetic) and 20 - 49 (hyperkinetic). [Sheehan, 1986].
122471 RCA Region in LAO Projection Based on a total number of chords of 100 and LAO projection the range of chords belonging to this regional extent lies between 19 - 67 (hypokinetic) and 68 - 100 (hyperkinetic). [Sheehan, 1986].
122472 CFX Region in LAO Projection Based on a total number of chords of 100 and LAO projection the range of chords belonging to this regional extent lies between 38 -74 (hypokinetic) and 75 - 100 (hyperkinetic). [Sheehan, 1986].
122473 Circular Method Method based on assumption that the image object is circular.
122474 Densitometric Method Method based on the gray value distribution of the image.
122475 Center of Gravity End Systolic contour realigned to End Diastolic contour based on the center of gravity.
122476 Long Axis Based End Systolic contour realigned to End Diastolic contour based on the mid point of the long axis. The long axis end points are defined as the posterior and apex.
122477 No Realignment No Contour Realignment applied.
122480 Vessel Lumen Cross-Sectional Area Calculated Vessel Lumen Cross-Sectional Area based on the referenced method.
122481 Contour Start Location of the beginning of a contour.
122482 Contour End Location of the end of a contour.
122485 Sphere Sphere visible in an image, which is used as a calibration or marker object.
122486 Geometric Isocenter Object of interest in isocenter of image and pixel separation is calculated from geometric data.
122487 Geometric Non-Isocenter Object of interest not in isocenter of image and pixel separation is calculated from geometric data and out of isocenter distances.
122488 Calibration Object Used Object used for calibration.
122489 Curve Fitted Reference Application dependent method to calculate the reference diameter based on the multiple diameter values.
122490 Interpolated Local Reference Application dependent method to calculate reference by interpolation, based on the diameter of two or more user defined reference positions.
122491 Mean Local Reference Application dependent method to calculate by averaging the reference, based on the diameter of one or more user defined reference positions.
122493 Radial Based Wall Motion Analysis Method to calculate wall motion based on the lengths of the radials in the predefined regions [Ingels].
122495 Regional Contribution to Ejection Fraction Contribution of Region to global Ejection factor based on radial or landmark based wall motion method.
122496 Radial Shortening The reduction of area between End Systolic and End Diastolic based on radial wall motion analysis.
122497 Landmark Based Wall Motion Analysis Method to calculate wall motion based on the move of landmarks on the wall [Slager].
122498 Slice Contribution to Ejection Fraction Contribution to the ejection fraction of a specific slice region [Slager].
122499 Frame to Frame Analysis Method to calculate volumes of heart chambers for every image in a range.
122501 Area of closed irregular polygon The area is derived by considering a set of coordinates as a closed irregular polygon, accounting for inner angles.The exact method, such as by decomposition into triangles or quadrilaterals, is not specified, since it does not affect the numeric result, apart from the effect of numeric precision during computation of intermediate results.
122502 Area of a closed NURBS The area is derived by using a set of coordinates as control points for a Non Uniform Rational B-Spline (NURBS).
122503 Integration of sum of closed areas on contiguous slices method for volume Method of integrating the sum of the areas on adjacent slices across the slice interval to derive a total volume; each area is defined by a regular planar shape or by considering a set of coordinates as a closed irregular polygon, accounting for inner angles.
122505 Calibration Procedure used to calibrate measurements or measurement devices.
122507 Left Contour Left contour of lumen (direction proximal to distal).
122508 Right Contour Right contour of lumen (direction proximal to distal).
122509 Diameter Graph Ordered set of diameters values derived from contours (direction proximal to distal).
122510 Length Luminal Segment Length Luminal Segment.
122511 Graph Increment Increment value along X-axis in Diameter Graph.
122516 Site of Maximum Luminal Location of the maximum lumen area in a lesion or vessel.
122517 Densitometric Luminal Cross-sectional Area Graph Ordered set of cross-sectional Vessel Lumen Cross-Sectional Area values derived from contours (direction proximal to distal) based on densitometric method.
122528 Position of Proximal Border Position of proximal border of segment relative to the contour start (proximal end of analysis area).
122529 Position of Distal Border Position of distal border of segment relative to the contour start (proximal end of analysis area).
122542 Plaque Area Longitudinal cross sectional area of plaque.
122544 Diameter Symmetry Symmetry of stenosis (0 = complete asymmetry, 1 = complete symmetry).
122545 Area Symmetry Symmetry of plaque (0 = complete asymmetry, 1 = complete symmetry).
122546 Inflow Angle The average slope of the diameter function between the position of the minimum luminal diameter and the position of the proximal border of the segment.
122547 Outflow Angle The average slope of the diameter function between the position of the minimum luminal diameter and the position of the distal border of the segment.
122548 Stenotic Flow Reserve The relation between coronary pressure and coronary flow.
122549 Poiseuille Resistance Poiseuille Resistance at the location of the stenosis.
122550 Turbulence Resistance Turbulence Resistance at the location of the stenosis.
122551 Pressure Drop at SFR Pressure drop over the stenosis at maximum heart output.
122554 Segmentation Method Method for selection of vessel sub-segments.
122555 Estimated Normal Flow Estimate of the volume of blood flow in the absence of stenosis.
122558 Area Length Kennedy Area Length method defined by Kennedy [Kennedy, 1970].
122559 Area Length Dodge Area Length method defined by Dodge [Dodge, 1960].
122560 Area Length Wynne Area Length method defined by Wynne [Wynne].
122562 Multiple Slices Volume method based on multiple slice.
122563 Boak Volume method defined by Boak [Boak].
122564 TS Pyramid Volume method defined by Ferlinz [Ferlinz].
122565 Two Chamber Volume method defined by Graham [Graham].
122566 Parallelepiped Volume method defined by Arcilla [Arcilla].
122572 BSA^1.219 Corrected Body Surface area for indexing the hemodynamic measurements for a pediatric patient.
122574 Equidistant method Method for selecting sub-segments that are all of the same length.
122575 User selected method Manually selected start and end of sub-segment.
122582 Left ventricular posterobasal segment Left ventricular posterobasal segment.
122600 Cardiovascular Analysis Report Report of a Cardiovascular Analysis, typically from a CT or MR study.
122601 Ventricular Analysis Ventricular Analysis.
122602 Myocardial Perfusion Analysis Myocardial Perfusion Analysis.
122603 Calcium Scoring Analysis Calcium Scoring Analysis.
122604 Flow Quantification Flow Quantification Analysis.
122605 Vascular Morphological Analysis Vascular Morphological Analysis.
122606 Vascular Functional Analysis Vascular Functional Analysis.
122607 Thickening Analysis Analysis of myocardial wall thickening.
122608 Absolute Values Of Ventricular Measurements Section Heading for absolute values of ventricular measurements.
122609 Normalized Values Of Ventricular Measurements Results of normalizing ventricular measurements.
122611 Reference Point Reference Point of a measurement.
122612 Central breathing position Central breathing position between inspiration and expiration.
122616 Peak Ejection Rate Peak of the ventricular ejection rate.
122617 Peak Ejection Time Time of the peak of ventricular ejection.
122618 Peak Filling Rate Peak of the fluid filling rate.
122619 Peak Filling Time Time interval until time of peak filling from a given reference point.
122620 Papillary Muscle Excluded Papillary muscle was excluded from the measurement.
122621 Papillary Muscle Included Papillary muscle was included in the measurement.
122624 Wall Thickness Ratio end-systolic to end-diastolic The ratio of the end-systolic wall thickness compared to the end-diastolic wall thickness.
122627 Curve Fit Method The method to smooth a ventricular volume as a function of time.
122628 Baseline Result Correction Baseline correction used in the calculation of the results.
122631 Signal Earliest Peak Time The time in a dynamic set of images at which the first peak of the signal is observed for the analyzed myocardial wall segments.
122633 Signal Increase Start Time This is the time at which the signal begins to increase.
122634 Signal Time to Peak Time interval between the beginning of the signal increase to the time at which the signal intensity reaches its first maximum in a dynamic set of images.
122635 MR Perfusion Peak Peak of the MR perfusion signal.
122636 MR Perfusion Slope Signal intensity as a function of time. It is the change in the signal intensity divided by the change in the time.
122637 MR Perfusion Time Integral MR perfusion time integral from baseline (foot time) to earliest peak.
122638 Signal Baseline Start First time point in a dynamic set of images used in the calculation of the baseline signal intensity for each myocardial wall segment.
122639 Signal Baseline End Last time point in a dynamic set of images used in the calculation of the baseline signal intensity for each myocardial wall segment.
122640 Image Interval The time delta between images in a dynamic set of images.
122642 Velocity Encoding Minimum Value The minimum velocity encoded by the phase encoding gradient.
122643 Velocity Encoding Maximum Value The maximum velocity encoded by the phase encoding gradient.
122645 Net Forward Volume Forward volume-reverse volume.
122650 Area Based Method Area Based Method for estimating volume or area.
122651 Diameter Based Method Diameter Based Method for estimating volume, area or diameter.
122652 Volume Based Method Volume Based Method for estimating volume.
122655 NASCET A method of diameter measurements according to NASCET (North American Symptomatic Carotid Endarterectomy Trial).
122656 ECST A method of diameter measurements according to ECST (European Carotid Surgery Trial).
122657 Agatston Score Threshold Agatston Score Threshold.
122658 Calcium Mass Threshold Calcium Mass Threshold.
122659 Calcium Scoring Calibration Calcium Scoring Calibration.
122660 Calcium Volume Calcium Volume.
122661 Calcium Mass Calcium Mass.
122664 Late Contrast Enhancement Delayed hyperenhancement of a tissue observed in an image acquired after injection of contrast media.
122665 Time interval since injection of contrast media Time interval since injection of contrast media.
122666 Time relative to R-wave peak Time relative to R-wave peak.
122667 Blood velocity vs. time of cardiac cycle Relationship between blood velocity and time relative to R-wave peak.
122668 Time interval since detection of contrast bolus Time interval since detection of contrast bolus.
122670 Papillary Muscle Included/Excluded Indicates if the papillary muscle was included or excluded in the measurement.
122675 Anterior-Posterior Anterior to Posterior direction.
122680 endoleak Persistent flow of blood into the stent-grafting.
122683 Stent Fracture Fracture of a stent.
122684 Stent Disintegration Disintegration of a stent.
122685 Stent Composition Material that a stent consists of.
122686 Parent Vessel Finding Finding about the characteristics of the parent vessel of a vessel.
122687 Site of Lumen Maximum Site of Maximal lumen diameter of a vessel.
122698 X-Concept The physical domain (time, space, etc.) to the horizontal axis of the graphical presentation.
122699 Y-Concept The physical domain (time, space, etc.) to the vertical axis of the graphical presentation.
122700 Indications for Pharmacological Stress Indications for Pharmacological Stress.
122701 Procedure time base Reference time for measurement of elapsed time in a procedure.
122702 Treadmill speed Treadmill speed.
122703 Treadmill gradient Treadmill gradient.
122704 Ergometer power Ergometer power.
122705 Pharmacological Stress Agent Dose Rate Pharmacological Stress Agent Dose Rate.
122706 Rating of Perceived Exertion Rating of Perceived Exertion.
122707 Number of Ectopic Beats Number of ectopic beats during a period of collection.
122708 Double Product Heart rate times systolic blood pressure.
122709 Activity workload Physical activity workload (intensity) measurement.
122710 Time since start of stage Elapsed time at stage.
122711 Exercise duration after stress agent injection Exercise duration after stress agent injection.
122712 Imaging Start DateTime Imaging Start DateTime.
122713 Attenuation correction method Attenuation correction method.
122715 Pharmacological Stress Agent Dose Pharmacological Stress Agent Dose.
122716 Maximum Power Output Achieved Maximum power output achieved during course of procedure.
122717 Peak activity workload Peak physical activity intensity measurement during course of procedure.
122718 Peak Double Product Peak Double Product measurement during course of procedure.
122720 OSEM algorithm Ordered subsets expectation maximization reconstruction algorithm.
122721 Chang method Chang attenuation correction method.
122726 Algorithmic attenuation correction Attenuation correction not based on image-based attenuation maps.
122727 NM transmission attenuation correction NM transmission attenuation correction.
122728 CT-based attenuation correction CT-based attenuation correction.
122729 No Attenuation Correction No attenuation correction.
122730 Bazett QTc Algorithm Bazett QT Correction Algorithm; QT/(RR ^ 0.5); Bazett HC. "An analysis of the time-relations of electrocardiograms" Heart7:353-370 (1920).
122731 Hodges QTc Algorithm Hodges QT Correction Algorithm; QT + 1.75 (heart rate-60); Hodges M, Salerno Q, Erlien D. "Bazett's QT correction reviewed. Evidence that a linear QT correction for heart rate is better." J Am Coll Cardiol1:694 (1983).
122732 Fridericia QTc Algorithm Fridericia QT Correction Algorithm; QT/(RR ^ 0.333); Fridericia LS. "The duration of systole in the electrocardiogram of normal subjects and of patients with heart disease" Acta Med Scand53:469-486 (1920).
122733 Framingham QTc Algorithm Framingham QT Correction Algorithm; QT + 0.154 (1- RR); Sagie A, Larson MG, Goldberg RJ, et al. "An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study)." Am J Cardiol70:797-801(1992).
122734 Borg RPE Scale Borg Rating of Perceived Exertion Scale, range 6:20.
122735 Borg CR10 Scale Borg category ratio scale, open ended range with nominal range 0:10.
122739 Overall study quality Quality of a study for the purpose for which it was created.
122740 Excellent image quality Quality of an image is excellent for the purpose for which it was created.
122741 Good image quality Quality of an image is good for the purpose for which it was created.
122742 Poor image quality Quality of an image is poor for the purpose for which it was created.
122743 Body habitus attenuation Image attenuation due to body physique (overweight).
122744 Breast attenuation Image attenuation due to breast tissue.
122745 Diaphragmatic attenuation Image attenuation due to diaphragm.
122748 False positive defect finding Finding of a defect is incorrect.
122750 Non-diagnostic - low heart rate ECG is non-diagnostic due to low heart rate.
122751 Non-diagnostic - resting ST abnormalities ECG is non-diagnostic due to resting ST abnormalities.
122752 Non-diagnostic - ventricular pacing or LBBB ECG is non-diagnostic due to ventricular pacing or Left Bundle Branch Block.
122753 Non-diagnostic ECG ECG is non-diagnostic for presence of acute coronary syndrome.
122755 Strongly positive Strongly positive finding.
122756 Strongly positive - ST elevation Strongly positive finding - ST elevation.
122757 ST Depression - Horizontal Finding of ST segment depression with no slope.
122758 ST Depression - Upsloping Finding of ST segment depression with upslope.
122759 ST Depression - Downsloping Finding of ST segment depression with downslope.
122760 Stress test score Stress test score.
122762 Number of diseased vessel territories Number of diseased vessel territories.
122764 Weight exceeds equipment limit Patient weight exceeds equipment limit.
122768 Difference in Ejection Fraction Difference in Ejection Fraction.
122769 Difference in ED LV Volume Difference in End Diastolic Left Ventricular Volume.
122770 Ratio of achieved to predicted maximal oxygen consumption Ratio of achieved to predicted maximal oxygen consumption.
122771 Ratio of achieved to predicted functional capacity Ratio of achieved to predicted functional capacity.
122772 Aerobic index Workload (Watts) at target heart rate divided by body weight.
122773 ST/HR Index ST depression at peak exercise divided by the exercise-induced increase in heart rate [Kligfield P, Ameisen O, Okin PM. "Heart rate adjustment of ST segment depression for improved detection of coronary artery disease." Circulation 1989;79:245-55.].
122775 Agreement with prior findings Agreement with prior findings.
122776 Disagreement with prior findings Disagreement with prior findings.
122781 Rest thallium/stress technetium procedure Nuclear Medicine Rest thallium/stress technetium procedure.
122782 Rest technetium/stress technetium 1 day procedure Nuclear Medicine Rest technetium/stress technetium 1 day procedure.
122783 Rest technetium/stress technetium 2 day procedure Nuclear Medicine Rest technetium/stress technetium 2 day procedure.
122784 Stress technetium/rest technetium 1 day procedure Nuclear Medicine Stress technetium/rest technetium 1 day procedure.
122785 NM Myocardial Viability procedure Nuclear Medicine Myocardial Viability procedure.
122791 PET Myocardial Perfusion, Rest only Positron Emission Tomography Perfusion Imaging procedure, rest only.
122792 PET Myocardial Perfusion, Stress only Positron Emission Tomography Perfusion Imaging procedure, stress only.
122793 PET Myocardial Perfusion, Rest and Stress Positron Emission Tomography Perfusion Imaging procedure, rest and stress.
122795 PET Myocardial Viability, Rest only Positron Emission Tomography Myocardial Viability procedure, rest only.
122796 PET Myocardial Viability, Stress only Positron Emission Tomography Myocardial Viability procedure, stress only.
122797 PET Myocardial Viability, Rest and Stress Positron Emission Tomography Myocardial Viability procedure, rest and stress.
122799 Anginal Equivalent Group of symptoms heralding angina pectoris that does not include chest pain (dyspnea, diaphoresis, profuse vomiting in a diabetic patient, or arm or jaw pain).
123001 Radiopharmaceutical Active ingredient (molecular) used for radioactive tracing.
123003 Radiopharmaceutical Start DateTime DateTime of radiopharmaceutical administration to the patient for imaging purposes.
123004 Radiopharmaceutical Stop DateTime Ending DateTime of radiopharmaceutical administration to the patient for imaging purposes.
123005 Radiopharmaceutical Volume Volume of radiopharmaceutical administered to the patient.
123006 Radionuclide Total Dose Total amount of radionuclide administered to the patient at Radiopharmaceutical Start Time.
123007 Radiopharmaceutical Specific Activity Activity per unit mass of the radiopharmaceutical at Radiopharmaceutical Start Time.
123009 Radionuclide Syringe Counts Pre-injection syringe acquisition count rate.
123010 Radionuclide Residual Syringe Counts Syringe acquisition count rate following patient injection.
123011 Contrast/Bolus Agent Contrast or bolus agent.
123012 Pre-Medication Medication to be administered at the beginning of the Scheduled Procedure Step.
123014 Target Region Anatomic Region to be imaged.
123015 Imaging Direction Direction of imaging (includes view, transducer orientation, patient orientation, and/or projection).
123016 Imaging Conditions Imaging condition for refinement of protocol (includes secondary posture, instruction, X-Ray / electron beam energy or nuclide, and ultrasound modes), as used in JJ1017 v3.0.
123019 Caudal 10 degree distal-cranioproximal oblique Caudal 10 degree distal-cranioproximal oblique radiographic projection, defined per Smallwood et al.
123101 Neighborhood Analysis Surface processing utilizing predefined weighting factors (i.e., kernels) applied to different data values depending on their location relative to other data values within the data domain. Includes Low Pass, High Pass, Gaussian, Laplacian, etc.
123102 Adaptive Filtering Surface processing applied non-uniformly utilizing a priori knowledge of the system and/or relative locations of the data values within the data domain. Example: Neighborhood analysis where weighting factors are modified continuously based on predefined criteria.
123103 Edge Detection Surface processing through the exploitation of discontinuities in the data values within their domain. Includes Gradient filters.
123104 Morphological Operations Surface processing based on the connectivity of values based on the shape or structure of the data values within their domain. Includes erode, dilate, etc.
123105 Histogram Analysis Surface processing applied to the distribution of the data values. Includes thresholding, Bayesian Classification, etc.
123106 Multi-Scale/Resolution Filtering Surface processing accomplished through varying the data domain size. Include deformable models.
123107 Cluster Analysis Surface processing accomplished by combining data values based on their relative location within their domain or value distribution. Includes K- and C-means, Fuzzy Analysis, Watershed, Seed Growing, etc.
123108 Multispectral Processing Surface processing accomplished through the weighted combination of multiple sets of data. Includes Principle Component Analysis, linear and non-linear weighed combinations, etc.
123109 Manual Processing Surface processing accomplished through human interaction. Region drawing.
123110 Artificial Intelligence Surface processing using Artificial Intelligence techniques, such as Machine Learning, Neural Networks, etc.
123111 Deformable Models Surface processing using Deformable Model techniques, such as Point Distribution Models, Level Sets, Simplex Meshes, etc.
125000 OB-GYN Ultrasound Procedure Report Document Title of OB-GYN procedure report.
125001 Fetal Biometry Ratios Report section for assessment of fetal growth using ratios and indexes.
125002 Fetal Biometry Report section for assessment of fetal growth.
125003 Fetal Long Bones Report section for assessment of fetal growth by long bone measurements.
125004 Fetal Cranium Report section for assessment of fetal cranium growth.
125005 Biometry Group Biometric assessment of.
125006 Biophysical Profile Report section for assessment of biophysical observations that evaluate fetal well-being according to Manning, Antepartum Fetal Evaluation: Development of a Fetal Biophysical Profile Score, Am. J Obstet Gynecol, 1980;136:787.
125007 Measurement Group A grouping of related measurements and calculations that share a common context.
125008 Fetus Summary Report section for fetus specific procedure summary observations.
125009 Early Gestation Report section for assessment of early gestation fetus.
125010 Identifier A name to differentiate between multiple instances of some item.
125011 Pelvis and Uterus Report section for assessment of pelvis and uterus.
125012 Growth Percentile rank The rank of a measured growth indicator relative to a normal distribution expressed as a percentage.
125013 Growth Z-score The rank of a measured growth indicator relative to a normal distribution expressed as the dimensionless quantity z = (x-m) /s where (x-m) is the deviation of the value x, from the distribution mean, m, and s is the standard deviation of the distribution.
125015 Fetus Characteristics Fetus characteristics (findings section title).
125016 Fetal Measurements Fetal Measurements (findings section title).
125021 Frame of Reference Identity There is a defined equivalence between the Frame of Reference of the Registration SOP instance and the Frame of Reference of the referenced images.
125022 Fiducial Alignment The registration is based on fiducials that represent patient or specimen features identified in each set of data.
125023 Acquisition Equipment Alignment Registration based on a-priori knowledge of the acquisition geometry. This is not an object registration as in fiducial registration. Rather, it specifies a known spatial relationship.
125024 Image Content-based Alignment Computed registration based on global image information.
125025 Visual Alignment Registration by visually guided manipulation.
125026 Image Content and Fiducial Based Alignment The registration is based on fiducials that represent patient or specimen features identified in each data set in combination with global image information.
125027 Deformed for Registration Values are derived by sampling data from a Source Image into a Registered Reference Coordinate System based on a Deformable Spatial Registration Instance.
125028 Source Deformable Spatial Registration Deformable Spatial Registration Instance used for image deformation.
125030 Inter-Hemispheric Plane A plane fiducial that specifies the location of the plane separating the two hemispheres of the brain.
125031 Right Hemisphere Most Anterior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the anterior limit of the right brain hemisphere.
125032 Right Hemisphere Most Posterior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the posterior limit of the right brain hemisphere.
125033 Right Hemisphere Most Superior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the superior limit of the right brain hemisphere.
125034 Right Hemisphere Most Inferior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the inferior limit of the Right brain hemisphere.
125035 Left Hemisphere Most Anterior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the anterior limit of the left brain hemisphere.
125036 Left Hemisphere Most Posterior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the posterior limit of the left brain hemisphere.
125037 Left Hemisphere Most Superior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the superior limit of the left brain hemisphere.
125038 Left Hemisphere Most Inferior A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the inferior limit of the left brain hemisphere.
125040 Background That which is not part of an object.
125041 Registration Input A segment for use as an input to an image registration process.
125100 Vascular Ultrasound Procedure Report Root Document Title for ultrasound vascular evidence reports (worksheets).
125101 Vessel Branch The particular vessel branch, such as the inferior, medial or lateral.
125102 Graft Type A descriptor or elaboration of the type of graft.
125105 Measurement Orientation A modifier to a 2D distance measurement to describe its orientation.
125106 Doppler Angle The angle formed between the Doppler beam line and the direction of blood flow within a region of interest in the body defined by the sample volume.
125107 Sample Volume Depth The depth of the center of the Doppler sample volume measured from skin line along the Doppler line.
125195 Pediatric Cardiac Ultrasound Report Pediatric Cardiac Ultrasound Report (document title).
125196 Fetal Cardiac Ultrasound Report Fetal Cardiac Ultrasound Report (document title).
125197 Adult Congenital Cardiac Ultrasound Report Adult Congenital Cardiac Ultrasound Report (document title).
125200 Adult Echocardiography Procedure Report Document title of adult echocardiography procedure (evidence) report.
125201 Illustration of Finding An image that is a pictorial representation of findings. The concept is typically used as a purpose of reference to an image, such as a depiction of myocardium segments depicting wall motion function.
125202 LV Wall Motion Score Index The average of all scored (non-zero) Left Ventricle segment wall motion scores.
125203 Acquisition Protocol A type of clinical acquisition protocol for creating images or image-derived measurements. Acquisition protocols may be specific to a manufacturer's product.
125204 Area-length biplane Method for calculating left ventricular volume from two orthogonal views containing the true long axis (usually the apical 4 and 2 chamber views). Volume = [pL1 / 6] * [(4A1) ¸ (pL1) ] * [(4A2) ¸ (pL2) ].
125205 Area-Length Single Plane Method for calculating left ventricular volume from a view containing the true long axis (usually the apical 4-chamber view). Volume = [8(A)2]¸[3pL].
125206 Cube Method (formula) for calculating left ventricle volumes and function derivatives (EF, SV, SI, etc.) that estimates the volume as the cube of diameter.
125207 Method of Disks, Biplane Method of calculating volume based on the summation of disk volumes. The disk axis is parallel to the left ventricular long axis and using a disk diameter averaged from the two chamber and four chamber views.
125208 Method of Disks, Single Plane Method of calculating volume based on the summation of disk volumes. The disk axis is parallel to the left ventricular long axis with disk diameter taken from the four-chamber view.
125209 Teichholz Method (formula) for calculating left ventricle volumes and function derivatives (EF, SV, SI, etc.) Volume = [7.0/(2.4+D) ]*D3.
125210 Area by Pressure Half-Time Mitral valve area (cm2) by Pressure Half-time = 220 (cm2.ms) / PHT (ms).
125211 Biplane Ellipse Area = P/4 X d1 X d2d1 = anterior/posterior axisd2 = medial/lateral axisHagen-Ansert, Sandra L., Textbook of Diagnostic Ultrasound, ed. 3, The C.V.Mosby Co., 1989, p. 73. .
125212 Continuity Equation For conduits in series ("in continuity"), volume flow is equal: A1*V1 = A2*V2. where V is the velocity.
125213 Continuity Equation by Mean Velocity For conduits in series ("in continuity"), volume flow is equal: A1*V1 = A2*V2. where V is the mean velocity.
125214 Continuity Equation by Peak Velocity For conduits in series ("in continuity"), volume flow is equal: A1*V1 = A2*V2. where V is the peak velocity.
125215 Continuity Equation by Velocity Time Integral For conduits in series ("in continuity"), volume flow is equal: A1*V1 = A2*V2. where V is the velocity time integral.
125216 Proximal Isovelocity Surface Area Utilizes aliasing velocity (by color Doppler) of flow into an orifice (often regurgitant or stenotic) to measure instantaneous flow rate, orifice area, and flow volume.The instantaneous flow rate = (2πr2vav) * (απ) where vav is the constant velocity known as aliasing velocity at radius r, vpis the peak velocity at the orifice, and α is the angle in radians of the constant velocity surface.Estimated Orifice area = Flow rate / vp, where vp is the peak velocity at the orifice and the flow rate is the PISA peak flow rate.The volume flow is then the product of the orifice area and Velocity Time Integral.
125217 Full Bernoulli ΔP = 4*(V12 - V22).
125218 Simplified Bernoulli ΔP = 4*V2.
125219 Doppler Volume Flow Volume flow = Conduit CSA * (Velocity Time Integral).
125220 Planimetry Direct measurement of an area by tracing an irregular perimeter.
125221 Left Ventricle Mass by M-mode Mass = 1.04 * [(ST+LVID+PWT)3 - LVID3] * 0.8+ 0.6. Mass unit is grams and length in cm.
125222 Left Ventricle Mass by Truncated Ellipse Mass = 1.05P ((b + t)2 X (2/3 (a + t) + d - d3 /3(a + t)2) - b2 (2/3a + d - d3 /3a2))a = Semi-major axis from widest minor axis radius to apex.b = Short axis radius calculated from short axis cavity areat = Myocardial thickness calculated from short axis epicardial and cavity areasd = Truncated semi-major axis from widest short axis diameter to plane of mitral annulus.Mass unit is grams and length in cm.Schiller NB et al: Recommendations for quantification of the left ventricle by two-dimensional echocardiography, American Society of Echocardiography 2:364, 1989. .
125223 4 Point Segment Finding Scale A four point, echocardiographic numeric scoring scheme of myocardium segments based on evaluation of wall motion and ventricle morphology. Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography, Journal of the American Society of Echocardiography, 2:358-367, 1989.
125224 5 Point Segment Finding Scale A five point, echocardiographic numeric scoring scheme of myocardium segments based on evaluation of wall motion and ventricle morphology. Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography, Journal of the American Society of Echocardiography, 2:358-367, 1989.
125225 5 Point Segment Finding Scale With Graded Hypokinesis A five point, echocardiographic numeric scoring scheme of myocardium segments based on evaluation of wall motion and ventricle morphology, with severity of hypokinesis graded. Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography, Journal of the American Society of Echocardiography, 2:358-367, 1989.
125226 Single Plane Ellipse Method of estimating volume from a planar ellipse. Equivalent to Biplane Ellipse with an assumption that the ellipse in the orthogonal plane has identical major and minor diameters.
125227 Modified Simpson Modified Simpson's Method of estimating ventricular volume, based on the method of disks with paired apical views.Schiller NB, et al. "Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms". J Am Soc Echocardiogr.1989 2(5):358-367. Sep-Oct.
125228 Bullet Method Bullet method of estimating ventricular volume.Volume = 5/6 * L * SL: Left ventricle long axis lengthS: Left ventricle area, SAX view at level of Mitral Valve.
125230 Power Doppler Color coded ultrasound images of blood flow, which depict the amplitude, or power, of Doppler signals.
125231 3D mode Volumetric ultrasound imaging
125233 Start of drug dose administration Onset of administration of dose of a drug.
125234 Start of contrast agent administration Onset of contrast agent administration.
125235 Destruction of microbubbles Destruction of ultrasonic contrast microbubbles by a high-energy ultrasound pulse.
125236 Onset of exercise Instant at which exercise begins.
125237 Cessation of exercise Instant at which exercise ends.
125238 Onset of stimulation Instant at which stimulation begins.
125239 Cessation of stimulation Instant at which stimulation ends.
125240 Line scan pattern Ultrasound transducer scan pattern in which information is gathered along a line.
125241 Plane scan pattern Ultrasound transducer scan pattern in which information is gathered within a plane.
125242 Volume scan pattern Ultrasound transducer scan pattern in which information is gathered within a volume.
125251 Non-imaging Doppler ultrasound transducer geometry Ultrasound transducer geometry characterized by a single scan line used for PW or CW Doppler scanning.
125252 Linear ultrasound transducer geometry Ultrasonic transducer geometry characterized by parallel lines.
125253 Curved linear ultrasound transducer geometry Ultrasonic transducer geometry characterized by radial lines normal to the outside of a curved surface.
125254 Sector ultrasound transducer geometry Ultrasonic transducer geometry characterized by lines originating from a common apex.
125255 Radial ultrasound transducer geometry Ultrasonic transducer geometry characterized by lines emanating radially from a single point.
125256 Ring ultrasound transducer geometry Ultrasonic transducer geometry characterized by a circular ring of transducer elements.
125257 Fixed beam direction Ultrasonic steering technique consisting of a single beam normal to the transducer face steered by the orientation of the probe.
125258 Mechanical beam steering Ultrasonic steering technique consisting of mechanically directing the beam.
125259 Phased beam steering Ultrasonic steering technique consisting of electronically-steered beams.
125261 External Transducer Transducer is designed to be placed onto the surface of the subject.
125262 Transesophageal Transducer Transducer is designed for insertion into the esophagus.
125263 Endovaginal Transducer Transducer is designed for insertion into the vagina.
125264 Endorectal Transducer Transducer is designed for insertion into the rectum.
125265 Intravascular Transducer Transducer is designed for insertion via a catheter.
125266 Endocavitary Transducer Transducer is designed for insertion into either the vaginal cavity or the rectal cavity.
125270 Left Ventricle Mass by Area Length method to measure the mass of the Left Ventricle via the ASE area-length method at end diastole.LV Mass = 1.05*(5/6*(A1*(L+t)) - 5/6*(A2*L))A1 = Left Ventricle epicardial SAX area at the level of the papillary muscle tips at end diastole.A2 = Left Ventricle endocardial SAX area cavity area at the level of the papillary muscle tips at end diastole.L = Left Ventricle apical view long axis length at end diastole.t = Myocardial thickness can be computed as:t = sqrt (A1/3.14) - sqrt (A2/3.14)Reference:1) Schiller, N.B., et al. "Recommendations for Quantification of the LV by Two-dimensional Echocardiography." J Am Soc Echo, Vol. 2, No. 5: 358-367, Sep-Oct 1989.2) Reichek, N., et al. "Anatomic Validation of Left Ventricular Mass Estimates from Clinical Two-dimensional Echocardiography: Initial Results." Circulation, Vol. 67, No. 2: 348-52, February 1983.
125271 Left Ventricle Mass by M-mode - adjusted by Height Equation = Left Ventricle Mass by M-mode (in gram) / (Height (in meter)) ^2.7Reference:Giovanni De Simone, et al. "Effect of Growth on Variability of Left Ventricular Mass: Assessment of Allometric Signals in Adults and Children and Their Capacity to Predict Cardiovascular Risk". New York, New York and Cincinnati, Ohio.
125272 Left Ventricle Mass by Truncated Ellipse - adjusted by Height Equation = Left Ventricle Mass by Truncated Ellipse / Height^2.7Reference:Giovanni De Simone, et al. "Effect of Growth on Variability of Left Ventricular Mass: Assessment of Allometric Signals in Adults and Children and Their Capacity to Predict Cardiovascular Risk". New York, New York and Cincinnati, Ohio.
125273 Left Ventricle Mass by Area Length - adjusted by Height Equation = Left Ventricle Mass by Area Length / Height^2.7Reference:Giovanni De Simone, et al. "Effect of Growth on Variability of Left Ventricular Mass: Assessment of Allometric Signals in Adults and Children and Their Capacity to Predict Cardiovascular Risk". New York, New York and Cincinnati, Ohio.
125301 Pre-coordinated Measurements Measurements that are described by a single pre-coordinated code.
125302 Post-coordinated Measurements Measurements that are described by a collection of (generally atomic) post-coordinated codes.
125303 Adhoc Measurements Measurements taken in an ad hoc fashion without any coordinated semantics.
125304 Untrackable Measurement The source system of the measurement does not maintain a persistent pre-coordinated code by which different instances of the measurement can be associated and tracked over multiple procedures.
125305 Finding Observation Type The type of observation made at the finding site, e.g., whether it is an observation of the structure of the finding site, an observation of the behavior of the finding site, or an observation of the blood flow at the finding site.
125306 Measurement Type The type of derivation used to obtain the measurement value. E.g. whether it is taken directly, formed as a ratio, normalized against an index, or calculated using a more elaborate equation.
125307 Measured Property The property that is being measured.Examples include mass, diameter, peak blood velocity.
125308 Measurement Divisor The measurement which is the denominator of a measurement that is divided. This applies to measurements such as ratios or indexed values.
125309 Short Label A brief label, suitable for display on a screen or report. (Not suitable for matching).
125310 Staged Measurements Measurements that need to be associated with a specific stage in a procedure or acquisition protocol.
125311 Structure of the Finding Site The subject of a measurement is the physical structure of the Finding Site, such as the mass or diameter.
125312 Behavior of the Finding Site The subject of a measurement is the behavior of the Finding Site, such as the velocity or duration of motion.
125313 Indexed The measurement has been normalized by dividing it by an index value (such as Body Surface Area).
125314 Fractional Change The measurement is a change value expressed as a fraction of its baseline value. E.g. cardiac ejection fraction or fractional shortening.
125315 Calculated The measurement is calculated by incorporating one or more measured values into an equation other than a ratio, fractional change or indexed calculation.
125316 Directly measured The measurement is a direct output of the measurement tool.
125317 Right Ventricle Outflow Tract, Distal The distal portion (at the Pulmonic Valve) of the Right Ventricle Outflow Tract.
125318 Right Ventricle Outflow Tract, Proximal The proximal portion (subvalvular) of the Right Ventricle Outflow Tract.
125319 Right Ventricle Anterior Wall The anterior wall of the right ventricle of the heart.
125320 Electromechanical Delay The period of time between the onset of muscle activation and the onset of force or motion.
125321 Pre-ejection Period The period between onset of ventricular contraction and the beginning of antegrade blood flow out of the ventricle.
125322 Atrial Diastolic Filling (D-wave) The period of atrial diastolic filling.
125323 AR-wave The period of retrograde flow into the pulmonary vein during atrial contraction.
125324 Full Cardiac Cycle The period of the entire cardiac cycle. E.g. from End Systole of one heartbeat to End Systole of the next heartbeat.
125325 Dyssynchrony Index The standard deviation over 12 left ventricle myocardial segments of the time to peak myocardial sustained systolic velocity of each segment.See Yu, et al., Circulation, 2002; 105: 438-445
125326 Effective Orifice Area The effective area of an orifice (such as the mitral valve orifice) during bloodflow through the orifice.
125327 Excursion Distance The distance traversed by some tissue over a defined period.
125328 Maximum Orifice Area The maximum area of an orifice opening over a defined period.
125329 Peak Blood Pressure The peak pressure of blood over a defined period at a defined location.
125330 Peak Tissue Velocity The peak velocity of some tissue over a defined period
125331 PISA Radius The radius of the proximal isovelocity surface area (PISA) of fluid flow approaching an orifice. It is commonly used to evaluate cardiac valve regurgitation.
125332 Regurgitation Jet Area A cross-sectional area of a regurgitation jet, taken perpendicular to the primary flow.
125333 Regurgitation Jet Width A width of a regurgitation jet taken perpendicular to the primary flow.
125334 Vena Contracta Width The width of the vena contracta of a fluid flow.
125901 CARDIOsphere CARDIOsphere™ ultrasonic contrast agent produced by POINT Biomedical.
125902 Echovist Echovist® ultrasonic contrast agent produced by Schering AG.
125903 Imagify Imagify™ ultrasonic contrast agent produced by Accusphere Inc.
125904 Levovist Levovist® ultrasonic contrast agent produced by Schering AG.
125905 Sonazoid Sonazoid™ ultrasonic contrast agent produced by Daiichi Pharmaceutical / General Electric.
125906 SonoVue SonoVue™ ultrasonic contrast agent produced by Bracco Diagnostics.
125907 Targestar-B Targestar™-B ultrasonic contrast agent produced by Targeson LLC.
125908 Targestar-P Targestar™-P ultrasonic contrast agent produced by Targeson LLC.
126000 Imaging Measurement Report A structured report containing the quantitative results of human or machine analysis of images.
126001 Oncology Measurement Report A structured report containing the quantitative results of human or machine analysis of images for oncology evaluation.
126002 Dynamic Contrast MR Measurement Report A structured report containing the quantitative results of human or machine analysis of DCE-MR.
126003 PET Measurement Report A structured report containing the quantitative results of human or machine analysis of PET images.
126010 Imaging Measurements Measurements made on images
126011 Derived Imaging Measurements Measurements derived from measurements made on images.
126020 Multiparametric MRI An MRI procedure in which multiple parameters including diffusion, dynamic contrast and T2 are measured.
126021 Multiparametric MRI of prostate An MRI procedure of the prostate in which multiple parameters including diffusion, dynamic contrast and T2 are measured.
126022 Multiparametric MRI of whole body An MRI procedure of the whole body in which multiple parameters including diffusion, dynamic contrast and T2 are measured.
126029 LWH method for volume of ellipsoid Method of calculation of the volume of an ellipsoid as length * width * height * π / 6.
126030 Sum of segmented voxel method for volume Method of summing the volumes of all the voxels (and partial voxels if the segment contains partially occupied voxels) included in the segment to derive a total volume.
126031 Peak Value Within ROI Maximum average gray value that is calculated from a 1 cubic centimeter sphere placed within the region of interest.See Wahl RL, Jacene H, Kasamon Y, Lodge MA. From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors. Journal of Nuclear Medicine. 2009;50(Suppl 1):122S - 150S.
126032 Metabolic Volume The volume of a lesion (e.g., a tumor) ascertained through information about its metabolic activity (e.g., SUV on PET).Abbreviated "MV". Synonymous with Metabolic Tumor Volume (MTV).
126033 Total Lesion Glycolysis The total activity of a lesion obtained as the product of its volume and its glycolytic activity (on FDG-PET).The volume may be defined on the same modality (e.g., the MV on FDG-PET by some thresholding or other technique) or on another spatially registered modality (e.g., the lesion outline segmented on CT or MR).Does not apply to other radiopharmaceuticals than those involved in glucose metabolism.Abbreviated TLG. Synonymnous with "Tumor Lesion Glycolysis".
126034 Glycolysis The amount glycolytic activity summed across all voxels in a defined region or within a defined range of SUV (on FDG-PET).
126035 Total Lesion Proliferation The total activity of a lesion obtained as the product of its volume and its proliferative activity (on FLT-PET).The volume may be defined on the same modality (e.g., the MV on FDG-PET by some thresholding or other technique) or on another spatially registered modality (e.g., the lesion outline segmented on CT or MR).Does not apply to other radiopharmaceuticals than those involved in cellular proliferation.Abbreviated TLP. Synonymnous with "Tumor Lesion Proliferation".
126036 Proliferative Activity The amount proliferative activity summed across all voxels in a defined region or within a defined range of SUV (on FLT-PET).
126037 Standardized Added Metabolic Activity (SAM) A background-corrected, partial volume independent version of TLG.SAM is calculated by drawing a volume of interest (VOI1) around the tumour and a larger VOI (VOI2) around VOI1. Subtracting the background activity in VOI2-VOI1 from VOI1 yields SAM.See Mertens et al. "Standardized added metabolic activity (SAM): a partial volume independent marker of total lesion glycolysis in liver metastases". Eur J Nucl Med Mol Imaging (2012) 39:1441-1448.
126038 Standardized Added Metabolic Activity (SAM) Background The background value (VOI2-VOI1) used to calculate Standardized Added Metabolic Activity (SAM).SAM is calculated by drawing a volume of interest (VOI1) around the tumour and a larger VOI (VOI2) around VOI1. Subtracting the background activity in VOI2-VOI1 from VOI1 yields SAM.See Mertens et al. "Standardized added metabolic activity (SAM): a partial volume independent marker of total lesion glycolysis in liver metastases". Eur J Nucl Med Mol Imaging (2012) 39:1441-1448.
126039 Lesion to Background SUV Ratio The ratio of the SUV within a tumor to the SUV of a pre-defined background region.A more general concept than Tumor to Background Ratio (TBR).
126040 Background for Lesion to Background SUV Ratio The SUV of a pre-defined background region used to compute Lesion to Background SUV Ratio.
126050 Fractal Dimension A statistical index of complexity comparing how detail in a fractal pattern changes with the scale at which it is measured; a ratio of the change in detail to the change in scale.
126051 Skewness Measure of the asymmetry of the probability distribution of a real-valued random variable about its mean.
126052 Kurtosis Measure of the peakedness of the probability distribution of a real-valued random variable.
126060 Joint Entropy of GLCM The zero order entropy of a Gray Level Co-occurrence Matrix (GLCM). A measure of disorder. Abbreviated ENT.See Fcm.joint.entr in .
126061 Root Angular Second Moment of GLCM The square root of the Angular Second Moment (ASM) of a Gray Level Co-occurrence Matrix (GLCM). A measure of orderliness.See .
126062 Inverse Difference Moment of GLCM The Inverse Difference Moment (homogeneity) of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated IDM.See Fcm.inv.diff.mom in .
126063 Contrast of GLCM The sum of squares of a Gray Level Co-occurrence Matrix (GLCM). A measure of gray level variations. Abbreviated CON.See Fcm.contrast in .
126064 Dissimilarity of GLCM The dissimilarity of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated DIS.See Fcm.dissimilarity in .
126065 Angular Second Moment of GLCM The Angular Second Moment of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated ASM.See Fcm.energy in .
126066 Correlation of GLCM A measure of the linear dependency of gray levels on those of neighbouring pixels of a Gray Level Co-occurrence Matrix (GLCM). Abbreviated COR.See Fcm.corr in .
126067 Gray Level Co-occurrence Matrix A tabulation of how often different combinations of pixel values (gray levels) occur in an image. Abbreviated GLCM.See .
126070 Subject Time Point Identifier An identifier of a specific time point in a continuum, which is unique within an appropriate local context (such as an entire organization, system or treatment protocol), which identifies the time point for a specific patient.
126071 Protocol Time Point Identifier An identifier of a specific time point in a continuum, which is unique within an appropriate local context (such as an entire organization, system or treatment protocol), which identifies the time point "slot" within a treatment protocol using the same value for all patients in the protocol.
126072 Time Point Type A pre-defined type of a specific time point in a continuum.
126073 Time Point Order A number indicating the order of a time point relative to other time points in the same continuum.
126074 Posttreatment The time after the treatment of interest.
126075 Eligibility For the purpose of determining eligibility for a protocol.
126080 RECIST 1.0 Response Evaluation Criteria in Solid Tumors version 1.0. See [RECIST] in Normative References.
126081 RECIST 1.1 Response Evaluation Criteria in Solid Tumors Version 1.1. See Eisenhauer et al. "New Response Evaluation Criteria in Solid Tumours: Revised RECIST Guideline (version 1.1)." European Journal of Cancer 45, no. 2 (n.d.): 228-47. doi:10.1016/j.ejca.2008.10.026.
126100 Real World Value Map used for measurement A reference to the Real World Value Map applied to the stored image pixel values before their use for a measurement
126200 Image Library Group A container that groups common information about a set of images used as evidence to produce a report.
126201 Acquisition Date The date the acquisition of data started
126202 Acquisition Time The time the acquisition of data started
126203 PET Radionuclide Incubation Time The time between the start of injection of the PET radionuclide and the start of acquisition of the PET data.
126220 R2-Coefficient Coefficient of determination, R2. An indication of goodness of fit.
126221 Chi-square Pearson's Χ2 test.
126222 D-W Durbin-Watson statistic for detecting serial correlation in residuals.See .
126223 AIC Akaike information criterion. A measure of the balance between goodness of fit and number of free parameters.See Akaike H. A new look at the statistical model identification. IEEE Transactions on Automatic Control. 1974 Dec;19(6):716-23. .
126224 BIC Bayesian information criterion. A measure of the balance between goodness of fit and model complexity.See .
126300 Perfusion analysis by Stable Xenon CT technique Perfusion analysis by Stable Xenon CT technique
126301 Perfusion analysis by IV Iodinated Contrast CT technique Perfusion analysis by IV Iodinated Contrast CT technique
126302 Perfusion analysis by Arterial Spin Labeling MR technique Perfusion analysis by Arterial Spin Labeling (ASL) MR technique
126303 Perfusion analysis by Susceptibility MR technique Perfusion analysis by Susceptibility (T2*) MR technique
126310 Least Mean Square (LMS) deconvolution Least Mean Square (LMS) deconvolution
126311 Singular Value Decomposition (SVD) deconvolution Singular Value Decomposition (SVD) deconvolution
126312 Ktrans Ktrans, the volume transfer constant of a tracer diffusion kinetic model, specifically the volume transfer constant between blood plasma and extravascular extracellular space (EES)See Tofts et al, "Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols", Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999.
126313 kep kep, the rate constant between extravascular extracellular space (EES) and blood plasmaSee Tofts et al, "Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols", Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999.
126314 ve ve, the fractional (not absolute) volume of extravascular extracellular space (EES) per unit volume of tissueSee Tofts et al, "Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols", Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999.
126320 IAUC The initial area under the contrast agent concentration-time curve
126321 IAUC60 The initial area under the contrast agent concentration-time curve at 60 seconds after the onset time
126322 IAUC90 The initial area under the contrast agent concentration-time curve at 90 seconds after the onset time
126323 IAUC180 The initial area under the contrast agent concentration-time curve at 180 seconds after the onset time
126324 IAUCBN The initial area under the contrast agent concentration-time curve, normalized with the corresponding arterial input function, such that IAUCBN = IAUC / IAUCAIF.
126325 IAUCBN60 The initial area under the contrast agent concentration-time curve at 60 seconds after the onset time, normalized with the corresponding arterial input function, such that IAUC60BN = IAUC60 / IAUC60AIF.
126326 IAUCBN90 The initial area under the contrast agent concentration-time curve at 90 seconds after the onset time, normalized with the corresponding arterial input function, such that IAUC90BN = IAUC90 / IAUC90AIF.
126327 AUCBN180 The initial area under the contrast agent concentration-time curve at 180 seconds after the onset time, normalized with the corresponding arterial input function, such that IAUC180BN = IAUC180 / IAUC180AIF.
126330 tau_m τm. The mean intracellular water lifetime (τi). Used in the Shutter-Speed Model (SSM) of tracer kinetics.
126331 vp vp. The fractional (not absolute) blood plasma volume per unit volume of tissue.See Tofts et al, "Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols", Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999.
126340 Standard Tofts Model A tracer diffusion kinetic model in which the permeability is assumed to be isodirectional.See P. Tofts, "Modeling tracer kinetics in dynamic Gd-DTPA MR imaging", Journal of Magnetic Resonance Imaging, vol. 7, pp. 91-101, 1997.Mathematically equivalent to the model proposed by Kety in a non-MRI context, hence sometimes refered to as the Tofts-Kety (TK) model. See Kety SS. The Theory and Applications of the Exchange of Inert Gas at the Lungs and Tissues. Pharmacological Reviews. 1951 Mar 1;3(1):1-41.
126341 Extended Tofts Model A tracer diffusion kinetic model in which the permeability is not assumed to be isodirectional, and which includes the contribution of tracer in the blood plasma to the total tissue concentration.See P. Tofts, "Modeling tracer kinetics in dynamic Gd-DTPA MR imaging", Journal of Magnetic Resonance Imaging, vol. 7, pp. 91-101, 1997.
126342 Model-free concentration-time quantitification A semiquantitative analysis of the contrast-enhancement concentration versus time curve that avoids the use of a pharmacokinetic model.
126343 First Pass Leakage Profile (FPLP) Model A tracer diffusion kinetic model that accounts for the tumor leakage profile during the first pass of contrast.See Li, Ka-Loh, Xiao Ping Zhu, John Waterton, and Alan Jackson. "Improved 3D Quantitative Mapping of Blood Volume and Endothelial Permeability in Brain Tumors." Journal of Magnetic Resonance Imaging 12, no. 2 (2000): 347-357. doi:​10.1002/​1522-2586(200008)12:​2<347::AID-JMRI19>​3.0.CO;2-7.
126344 Shutter-Speed Model (SSM) A tracer diffusion kinetic model that does not assume that intercompartmental water molecule exchange is infinitely fast.See Li, Xin, Wei Huang, Thomas E. Yankeelov, Alina Tudorica, William D. Rooney, and Charles S. Springer. "Shutter-Speed Analysis of Contrast Reagent Bolus-Tracking Data: Preliminary Observations in Benign and Malignant Breast Disease." Magnetic Resonance in Medicine 53, no. 3 (2005): 724-29. doi:10.1002/mrm.20405.
126345 Gamma Capillary Transit Time (GCCT) Model A tracer diffusion kinetic model that mathematically unifies the Tofts, Extended Tofts, Adiabatic Tissue Homogeneity, and Two Compartment Exchange modelsSee Schabel MC. A unified impulse response model for DCE-MRI. Magnetic Resonance in Medicine. 2012;68(5):1632-46. doi:10.1002/mrm.24162.
126346 Adiabatic Tissue Homogeneity (ATH) Model An adiabatic approximation to the tissue homogeneity tracer diffusion kinetic model, which assumes that the tracer concentration in parenchymal tissue changes slowly relative to that in capillaries.See St. Lawrence KS, Lee T-Y. An Adiabatic Approximation to the Tissue Homogeneity Model for Water Exchange in the Brain: I. Theoretical Derivation. J Cereb Blood Flow Metab. 1998 Dec;18(12):1365-77. doi:10.1097/00004647-199812000-00011.
126347 Two Compartment Exchange (2CX) Model A tracer diffusion kinetic that incorporates the extracellular space of the lesion as a peripheral compartment, connected to the central (plasma) compartment by linear exchange processes in both directions.See Brix G, Semmler W, Port R, Schad LR, Layer G, Lorenz WJ. Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging. Journal of Computer Assisted Tomography. 1991;15(4):621-8.
126350 T1 by Multiple Flip Angles T1 measurement by Multiple Flip Angles (MFA) (variable saturation) method
126351 T1 by Inversion Recovery T1 measurement by Inversion Recovery (IR) method
126352 T1 by Fixed Value Calculation was performed using a fixed value of T1 rather than a measured value. The value could be encoded as the value of (126353, DCM, "T1 Used For Calculation").
126353 T1 Used For Calculation The fixed value of T1 used for a calculation.
126360 AIF Ignored No Arterial Input Function was used.
126361 Population Averaged AIF A population-averaged Arterial Input Function.
126362 User-defined AIF ROI An Arterial Input Function computed from a user-defined Region of Interest.
126363 Automatically Detected AIF ROI An Arterial Input Function computed from an automatically detected Region of Interest.
126364 Blind Estimation of AIF A data-driven blind source separation (BSS) algorithm that estimates AIF from individuals without any presumed AIF model and initialization. See Lin, Yu-Chun, Tsung-Han Chan, Chong-Yung Chi, Shu-Hang Ng, Hao-Li Liu, Kuo-Chen Wei, Yau-Yau Wai, Chun-Chieh Wang, and Jiun-Jie Wang. "Blind Estimation of the Arterial Input Function in Dynamic Contrast-Enhanced MRI Using Purity Maximization." Magnetic Resonance in Medicine 68, no. 5 (November 1, 2012): 1439-49. doi:10.1002/mrm.24144.
126370 Time of Peak Concentration The time at which the concentration-time curve achieves its peak for the first time. Used as a concept name for a value or as a method.
126371 Bolus Arrival Time The nominal time at which arrival of a contrast bolus is detected, which is used as a reference point for subsequent calculations. Used as a concept name for a value or as a method. No specific computational method is implied by this general definition. Abbreviated BAT.
126372 Time of Leading Half-Peak Concentration The time at which the concentration-time curve achieves half of its peak density for the first time. Used as a concept name for a value or as a method.
126373 Temporal Derivative Exceeds Threshold A method of determining BAT that involves computing the temporal derivative of the concentration-time curve and selecting the time when the temporal derivative exceeds a specified threshold. See Shpilfoygel Med Phys 2008. doi:10.1118/1.1288669.
126374 Temporal Derivative Threshold A threshold applied to the temporal derivative of the concentration-time curve.
126375 Maximum Slope The maximum rate of signal intensity change within a measured region of a time-activity curve. See Boonsirikamchai, Piyaporn, Harmeet Kaur, Deborah A. Kuban, Edward Jackson, Ping Hou, and Haesun Choi. "Use of Maximum Slope Images Generated From Dynamic Contrast-Enhanced MRI to Detect Locally Recurrent Prostate Carcinoma After Prostatectomy: A Practical Approach." American Journal of Roentgenology 198, no. 3 (March 1, 2012): W228-W236. doi:10.2214/AJR.10.6387.
126376 Maximum Difference The maximum degree of signal intensity change within a measured region of a time-activity curve. See Boonsirikamchai, Piyaporn, Harmeet Kaur, Deborah A. Kuban, Edward Jackson, Ping Hou, and Haesun Choi. "Use of Maximum Slope Images Generated From Dynamic Contrast-Enhanced MRI to Detect Locally Recurrent Prostate Carcinoma After Prostatectomy: A Practical Approach." American Journal of Roentgenology 198, no. 3 (March 1, 2012): W228-W236. doi:10.2214/AJR.10.6387.
126377 Tracer Concentration Tracer concentration in tissue.
126380 Contrast Longitudinal Relaxivity The degree to which a paramagnetic contrast agent can enhance the proton longitudinal relaxation rate constant (R1, 1/T1), normalized to the concentration of the contrast agent. Also referred to as r1. Typically expressed in units of l/mmol/s.
126390 Absolute Regional Blood Flow The absolute flow rate of blood perfusing a region as volume per mass per unit of time. The mass divisor may be approximated by a measurement of volume assuming a tissue density of 1.
126391 Absolute Regional Blood Volume The absolute volume of blood perfusing a region as volume per mass. The mass divisor may be approximated by a measurement of volume assuming a tissue density of 1.
126392 Oxygen Extraction Fraction The percent of the oxygen removed from the blood by tissue during its passage through the capillary network. For example, as measured by blood oxygenation level dependent (BOLD) MR. See He, Xiang, and Dmitriy A. Yablonskiy. "Quantitative BOLD: Mapping of Human Cerebral Deoxygenated Blood Volume and Oxygen Extraction Fraction: Default State." Magnetic Resonance in Medicine 57, no. 1 (2007): 115-26.
126393 R1 The longitiudinal relaxation rate constant for the decay of longitiudinal magnetization caused by spin-lattice relaxation. The inverse of longitudinal relaxation time, i.e., R1 = 1/T1.
126394 R2 The transverse relaxation rate constant for the decay of transverse magnetization caused by spin-spin relaxation. The inverse of transverse relaxation time, i.e., R2 = 1/T2.
126395 R2* The transverse relaxation rate constant for the decay of transverse magnetization caused by a combination of spin-spin relaxation and magnetic field inhomogeneity. The inverse of transverse relaxation time, i.e., R2* = 1/T2*.
126396 Magnetic Susceptibility Magnetic Susceptibility is a measure of the amount of magnetization induced in a material when placed in an external magnetic field. It is the quantity encoded as the voxel intensity in Quantitative Susceptibility Map (QSM) images.It is a dimensionless quantity, usually recorded with units of parts per millions (ppm).See Liu T, Wisnieff C, Lou M, Chen W, Spincemaille P, Wang Y. Nonlinear formulation of the magnetic field to source relationship for robust quantitative susceptibility mapping. Magnetic Resonance in Medicine. 2013;69(2):467-76. .See Wang Y, Liu T. Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker. Magnetic Resonance in Medicine. 2015;73(1):82-101. .
126397 Relative Regional Blood Flow The relative flow rate of blood perfusing a region. Obtained by dividing the absolute flow rate of blood perfusing a region by the absolute flow rate of blood perfusing a reference region.
126398 Relative Regional Blood Volume The relative volume of blood perfusing a region. Obtained by dividing the absolute volume of blood perfusing a region by the absolute volume of blood perfusing a reference region.
126400 Standardized Uptake Value A ratio of locally measured radioactivity concentration versus the injected radioactivity distributed evenly throughout the whole body.This general concept encompasses all specific methods of calculating the whole body volume of distribution, such as using body weight, lean body mass, body surface area, etc.
126401 SUVbw Standardized Uptake Value calculated using body weight. The patient size correction factor for males and females is body weight.Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at
126402 SUVlbm Standardized Uptake Value calculated using lean body mass by James method. The patient size correction factor for males is 1.10 * weight - (120 or 128) * (weight/height) ^2, and for females is 1.07 * weight - 148 * (weight/height) ^2.Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at , except that either 120 or 128 may be used as the multiplier parameter for males).Unfortunately, Sugawara used a parameter of 120 rather than 128, propagating an error in Morgan DJ, Bray KM. Lean Body Mass as a Predictor of Drug Dosage: Implications for Drug Therapy. Clinical Pharmacokinetics. 1994;26(4):292-307, which misquoted the original LBM definition that used 128 in James WPT, Waterlow JC. Research on Obesity: A Report of the DHSS/MRC Group. London: Her Majesty’s Stationery Office; 1976. Implementations differ in whether they have used 120 or 128 when using this code. See Kelly M. SUV: Advancing Comparability and Accuracy. Siemens; 2009. Available from: .
126403 SUVbsa Standardized Uptake Value calculated using body surface area. The patient size correction factor for males and females is weight^ 0.425 * height^0.725 * 0.007184.Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at
126404 SUVibw Standardized Uptake Value calculated using ideal body weight. The patient size correction factor for males is 48.0 + 1.06 * (height - 152) and for females is 45.5 + 0.91 * (height - 152).Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at
126405 SUVlbm(Janma) Standardized Uptake Value calculated using lean body mass by Janmahasatian method. The patient size correction factor for males is 9.27E3 * weight / (6.68E3 + 216 * weight / (height^2)) and for females is 9.27E3 * weight / (8.78E3 + 244 * weight / (height^2)).Defined in Janmahasatian et al. Quantification of Lean Bodyweight. Clin Pharmacokinet. 2005 Oct 1;44(10):1051-65. at and its role in SUVlbm(Janma) calculation is discussed in Tahari et al. Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging. Journal of Nuclear Medicine. 2014 Sep 1;55(9):1481-4. at .
126406 SUVlbm(James128) Standardized Uptake Value calculated using lean body mass by James method, using the originally published 128 multiplier for males. The patient size correction factor for males is 1.10 * weight - 128) * (weight/height) ^2, and for females is 1.07 * weight - 148 * (weight/height) ^2.
126410 SUV body weight calculation method Method of calculating Standardized Uptake Value using body weight. The patient size correction factor for males and females is body weight.Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at
126411 SUV lean body mass calculation method Method of calculating Standardized Uptake Value using lean body mass. The patient size correction factor for males is 1.10 * weight - (120 or 128) * (weight/height) ^2, and for females is 1.07 * weight - 148 * (weight/height) ^2.Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at Unfortunately, Sugawara used a parameter of 120 rather than 128, propagating an error in Morgan DJ, Bray KM. Lean Body Mass as a Predictor of Drug Dosage: Implications for Drug Therapy. Clinical Pharmacokinetics. 1994;26(4):292-307, which misquoted the original LBM definition that used 128 in James WPT, Waterlow JC. Research on Obesity: A Report of the DHSS/MRC Group. London: Her Majesty’s Stationery Office; 1976. Implementations differ in whether they have used 120 or 128 when using this code. See Kelly M. SUV: Advancing Comparability and Accuracy. Siemens; 2009. Available from: .
126412 SUV body surface area calculation method Method of calculating Standardized Uptake Value using body surface area. The patient size correction factor for males and females is weight^ 0.425 * height^0.725 * 0.007184.Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at
126413 SUV ideal body weight calculation method Method of calculating Standardized Uptake Value using ideal body weight. The patient size correction factor for males is 48.0 + 1.06 * (height - 152) and for females is 45.5 + 0.91 * (height - 152).Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at
126414 SUV lean body mass calculation Janmahasatian method Janmahasatian method of calculating Standardized Uptake Value using lean body mass. The patient size correction factor for males is 9.27E3 * weight / (6.68E3 + 216 * weight / (height^2)) and for females is 9.27E3 * weight / (8.78E3 + 244 * weight / (height^2)).Defined in Janmahasatian et al. Quantification of Lean Bodyweight. Clin Pharmacokinet. 2005 Oct 1;44(10):1051-65. at and its role in SUVlbm(Janma) calculation is discussed in Tahari et al. Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging. Journal of Nuclear Medicine. 2014 Sep 1;55(9):1481-4. at .
126415 SUV lean body mass calculation method using 128 multiplier James method of calculating Standardized Uptake Value using lean body mass with the originally published 128 multiplier for males. The patient size correction factor for males is 1.10 * weight - 128) * (weight/height) ^2, and for females is 1.07 * weight - 148 * (weight/height) ^2.
126500 Pittsburgh compound B C^11^ A beta-amyloid PET radiotracer that is an analog of thioflavin T.
126501 Florbetaben F^18^ A beta-amyloid PET radiotracer.
126502 T807 F^18^ A PHF-tau PET radiotracer.
126503 Flubatine F^18^ A nicotinic α4β2 receptor (nAChR) PET radiotracer.
126509 Lutetium^177^ n-acetylaspartylglutamate A radioconjugate consisting of n-acetylaspartylglutamate labeled with lutetium Lu 177 used as a radiotracer.
126510 Monoclonal Antibody (mAb) ^64^Cu A Cu 64 Monoclonal Antibody (mAb) PET Radiotracer.
126511 Monoclonal Antibody (mAb) ^89^Zr A Zr 89 Monoclonal Antibody (mAb) PET Radiotracer.
126512 Trastuzumab ^89^Zr A Zr 89 Trastuzumab PET Radiotracer.
126513 Cetuximab ^89^Zr A Zr 89 Cetuximab PET Radiotracer.
126514 J591 ^89^Zr A Zr 89 J591 PET Radiotracer.
126515 cU36 ^89^Zr A Zr 89 cU36 PET Radiotracer.
126516 Bevacizumab ^89^Zr A Zr 89 Bevacizumab PET Radiotracer.
126517 cG250-F(ab')(2) ^89^Zr A Zr 89 cG250-F(ab')(2) PET Radiotracer.
126518 R1507 ^89^Zr A Zr 89 R1507 PET Radiotracer.
126519 E4G10 ^89^Zr A Zr 89 E4G10 PET Radiotracer.
126520 Df-CD45 ^89^Zr A Zr 89 Df-CD45 PET Radiotracer.
126600 ^44^Scandium ^44^Scandium
126601 ^51^Manganese ^51^Manganese
126602 ^70^Arsenic ^70^Arsenic
126603 ^90^Niobium ^90^Niobium
126604 ^191m^Iridium ^191m^Iridium
126605 ^43^Scandium ^43^Scandium
126606 ^152^Terbium ^152^Terbium
126607 ^52m^Manganese ^52m^Manganese
126700 ATSM Cu^60^ A Cu 60 ATSM PET radiotracer.
126701 ATSM Cu^61^ A Cu 61 ATSM PET radiotracer.
126702 ATSM Cu^62^ A Cu 62 ATSM PET radiotracer.
126703 Choline C^11^ A C 11 Choline PET radiotracer.
126704 Fallypride C^11^ A C 11 Fallypride PET radiotracer.
126705 Fallypride F^18^ An F 18 Fallypride PET radiotracer.
126706 FLB 457 C^11^ A C 11 FLB 457 PET radiotracer.
126707 Fluorotriopride F^18^ An F 18 Fluorotriopride PET radiotracer.
126708 Fluoromisonidazole (FMISO) F^18^ An F 18 Fluoromisonidazole PET radiotracer.
126709 Glutamine C^11^ A C 11 Glutamine PET radiotracer.
126710 Glutamine C^14^ A C 14 Glutamine PET radiotracer.
126711 Glutamine F^18^ An F 18 Glutamine PET radiotracer.
126712 Flubatine F^18^ An F 18 Flubatine PET radiotracer.
126713 2FA F^18^ An F 18 2FA PET radiotracer.
126714 Nifene F^18^ An F 18 Nifene PET radiotracer.
126715 CLR1404 I^124^ An I 124 cancer targeted phospholipid ether PET radiotracer.
126716 CLR1404 I^131^ An I 131 cancer targeted phospholipid ether PET radiotracer.
126717 THK5351 F^18^ A PET radiotracer used for tau brain imaging.See Harada R, Okamura N, Furumoto S, Furukawa K, Ishiki A, Tomita N, et al. 18F-THK5351: A Novel PET Radiotracer for Imaging Neurofibrillary Pathology in Alzheimer Disease. Journal of Nuclear Medicine. 2016 Feb 1;57(2):208-14. doi:10.2967/jnumed.115.164848
126718 Flurpiridaz F^18^ A PET radiotracer used for myocardial perfusion imaging.See Yu M, Nekolla SG, Schwaiger M, Robinson SP. The Next Generation of Cardiac Positron Emission Tomography Imaging Agents: Discovery of Flurpiridaz F-18 for Detection of Coronary Disease. Seminars in Nuclear Medicine. 2011 Jul;41(4):305-13. doi:10.1053/j.semnuclmed.2011.02.004See SNMMI. Flurpiridaz.
126719 RO6924963 ^11^C A PET radiotracer used for tau brain imaging.See Wong DF, Comley R, Kuwabara H, Rosenberg PB, Resnick SM, Ostrowitzki S, et al. First in-human PET study of 3 novel tau radiopharmaceuticals: [11C]RO6924963, [11C]RO6931643, and [18F]RO6958948. J Nucl Med. 2018 May 4; doi:10.2967/jnumed.118.209916.
126720 RO6931643 ^11^C A PET radiotracer used for tau brain imaging.See Wong DF, Comley R, Kuwabara H, Rosenberg PB, Resnick SM, Ostrowitzki S, et al. First in-human PET study of 3 novel tau radiopharmaceuticals: [11C]RO6924963, [11C]RO6931643, and [18F]RO6958948. J Nucl Med. 2018 May 4; doi:10.2967/jnumed.118.209916.
126721 Obinituzimab ^89^Zr A Zr 89 Obinituzimab PET Radiotracer.
126722 Benralizumab ^89^Zr A Zr 89 Benralizumab PET Radiotracer.
126723 Ocaratuzumab ^89^Zr A Zr 89 Ocaratuzumab PET Radiotracer.
126724 Glembatumumab vedotin ^89^Zr A Zr 89 Glembatumumab vedotin PET Radiotracer.
126725 Pinatuzumab vedotin ^89^Zr A Zr 89 Pinatuzumab vedotin PET Radiotracer.
126726 Polatuzumab vedotin ^89^Zr A Zr 89 Polatuzumab vedotin PET Radiotracer.
126727 Blinatumomab ^89^Zr A Zr 89 Blinatumomab PET Radiotracer.
126728 Pegdinetanib ^89^Zr A Zr 89 Pegdinetanib PET Radiotracer.
126729 AGN-150998 ^89^Zr A Zr 89 AGN-150998 PET Radiotracer.
126730 MEDI-551 ^89^Zr A Zr 89 MEDI-551 PET Radiotracer.
126731 GA201 ^89^Zr A Zr 89 GA201 PET Radiotracer.
126732 Ecromeximab ^89^Zr A Zr 89 Ecromeximab PET Radiotracer.
126733 Roledumab ^89^Zr A Zr 89 Roledumab PET Radiotracer.
126734 XmAb5574 ^89^Zr A Zr 89 XmAb5574 PET Radiotracer.
126735 Brentuximab ^89^Zr A Zr 89 Brentuximab PET Radiotracer.
126736 Panitumumab ^89^Zr A Zr 89 Panitumumab PET Radiotracer.
126737 Rituximab ^89^Zr A Zr 89 Rituximab PET Radiotracer.
126738 Mogamulizumab ^89^Zr A Zr 89 Mogamulizumab PET Radiotracer.
126739 Ublituximab ^89^Zr A Zr 89 Ublituximab PET Radiotracer.
126740 Margetuximab ^89^Zr A Zr 89 Margetuximab PET Radiotracer.
126741 SAR3419 ^89^Zr A Zr 89 SAR3419 PET Radiotracer.
126742 Ranibizumab ^89^Zr A Zr 89 Ranibizumab PET Radiotracer.
126746 cMAb U36 ^89^Zr A Zr 89 cMAb U36 PET Radiotracer.
126747 DN30 ^89^Zr A Zr 89 DN30 PET Radiotracer.
126748 Fresolimumab ^89^Zr A Zr 89 Fresolimumab PET Radiotracer.
126749 TRC105 ^89^Zr A Zr 89 TRC105 PET Radiotracer.
126750 7E11 ^89^Zr A Zr 89 7E11 PET Radiotracer.
126751 7D12 ^89^Zr A Zr 89 7D12 PET Radiotracer.
126752 28H1 ^89^Zr A Zr 89 28H1 PET Radiotracer.
126753 Nanocolloidal albumin ^89^Zr A Zr 89 nanocolloidal albumin PET Radiotracer.See Heuveling et al. Pilot Study on the Feasibility of PET/CT Lymphoscintigraphy with 89Zr-Nanocolloidal Albumin for Sentinel Node Identification in Oral Cancer Patients. J Nucl Med. 2013 Apr;54(4):585-9. doi:10.2967/jnumed.112.115188. http://jnm.snmjournals.org/content/54/4/585.long
126754 Anti-B220 ^89^Zr A Zr 89 Anti-B220 PET Radiotracer.
126755 RO5323441 ^89^Zr A Zr 89 RO5323441 PET Radiotracer.
126756 RO542908 ^89^Zr A Zr 89 RO542908 PET Radiotracer.
126757 RO6958948 ^18^F A PET radiotracer used for tau brain imaging.See Wong DF, Comley R, Kuwabara H, Rosenberg PB, Resnick SM, Ostrowitzki S, et al. First in-human PET study of 3 novel tau radiopharmaceuticals: [11C]RO6924963, [11C]RO6931643, and [18F]RO6958948. J Nucl Med. 2018 May 4; doi:10.2967/jnumed.118.209916.
126758 PSMA-1007 F^18^ A PET radiotracer targeting PMSA used for prostate cancer imaging.See Giesel FL, Hadaschik B, Cardinale J, Radtke J, Vinsensia M, Lehnert W, et al. F-18 labelled PSMA-1007: biodistribution, radiation dosimetry and histopathological validation of tumor lesions in prostate cancer patients. Eur J Nucl Med Mol Imaging. 2017 Apr 1;44(4):678–88. doi:10.1007/s00259-016-3573-4.
126759 PSMA-617 Ga^68^ A PET radiotracer targeting PMSA used for prostate cancer imaging.See Afshar-Oromieh A, Hetzheim H, Kratochwil C, Benesova M, Eder M, Neels OC, et al. The Theranostic PSMA Ligand PSMA-617 in the Diagnosis of Prostate Cancer by PET/CT: Biodistribution in Humans, Radiation Dosimetry, and First Evaluation of Tumor Lesions. J Nucl Med. 2015 Nov 1;56(11):1697–705. doi: 10.2967/jnumed.115.161299.
126760 Df-FK ^89^Zr A Zr 89 Df-FK peptide PET Radiotracer.See Jacobsen O et al. MicroPET Imaging of Integrin αvβ3 Expressing Tumors Using 89Zr-RGD Peptides. Mol Imaging Biol. 2011 Dec; 13(6): 1224-1233. doi:10.1007/s11307-010-0458-y. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3137711/
126761 Df-FK-PEG(3) ^89^Zr A Zr 89 Df-FK-PEG(3) peptide PET Radiotracer.See Jacobsen O et al. MicroPET Imaging of Integrin αvβ3 Expressing Tumors Using 89Zr-RGD Peptides. Mol Imaging Biol. 2011 Dec; 13(6): 1224-1233. doi:10.1007/s11307-010-0458-y. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3137711/
126762 Df-[FK](2) ^89^Zr A Zr 89 Df-[FK](2) peptide PET Radiotracer.See Jacobsen O et al. MicroPET Imaging of Integrin αvβ3 Expressing Tumors Using 89Zr-RGD Peptides. Mol Imaging Biol. 2011 Dec; 13(6): 1224-1233. doi:10.1007/s11307-010-0458-y. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3137711/
126763 Df-[FK](2)-3PEG(4) ^89^Zr A Zr 89 Df-[FK](2)-3PEG(4) peptide PET Radiotracer.See Jacobsen O et al. MicroPET Imaging of Integrin αvβ3 Expressing Tumors Using 89Zr-RGD Peptides. Mol Imaging Biol. 2011 Dec; 13(6): 1224-1233. doi:10.1007/s11307-010-0458-y. http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3137711/
126764 Iodinated I^125^ DPA-713 An I125 translocator protein (TSPO) SPECT tracer.See Wang H, Pullambhatla M, Guilarte TR, Mease RC, Pomper MG. Synthesis of [125I]IodoDPA-713, a New Probe for Imaging Inflammation. Biochem Biophys Res Commun. 2009 Nov 6;389(1):80–3. doi:10.1007/​10.1016/​j.bbrc.2009.08.102http://​www.ncbi.nlm.nih.gov/​pmc/​articles/​PMC2764231/
126765 DPA-713 ^11^C A C11 translocator protein (TSPO) PET tracer.See Endres CJ, Pomper MG, James M, Uzuner O, Hammoud DA, Watkins CC, et al. Initial Evaluation of 11C-DPA-713, a Novel TSPO PET Ligand, in Humans. J Nucl Med. 2009 Aug;50(8):1276–82. doi:10.2967/​jnumed.109.062265http://www.ncbi.nlm.nih.gov/​pmc/​articles/​PMC2883612/
126766 DPA-714 ^18^F An F18 translocator protein (TSPO) PET tracer.See Vicidomini C, Panico M, Greco A, Gargiulo S, Coda ARD, Zannetti A, et al. In vivo imaging and characterization of [18F]DPA-714, a potential new TSPO ligand, in mouse brain and peripheral tissues using small-animal PET. Nuclear Medicine and Biology. 2015 Mar 1;42(3):309–16. doi:10.1016/​j.nucmedbio.2014.11.009
126801 IEC61217 Patient Support Continuous Yaw Angle Patient Support isocentric rotation (in the IEC FIXED REFERENCE Coordinate System) as defined by . DICOM represents this value as a Continuous Rotation Angle in degrees.
126802 IEC61217 Table Top Continuous Pitch Angle Pitch of the Table Top (in the IEC TABLE TOP Coordinate System) as defined by . DICOM represents this value as a Continous Rotation Angle in degrees.
126803 IEC61217 Table Top Continuous Roll Angle Roll of the Table Top (in the IEC TABLE TOP Coordinate System) as defined by . DICOM represents this value as a Continous Rotation Angle in degrees.
126804 IEC61217 Table Top Eccentric Axis Distance Eccentric axis offset, in mm (in the IEC PATIENT SUPPORT Coordinate System) as defined by .
126805 IEC61217 Table Top Continuous Eccentric Angle Table Top eccentric rotation (in the IEC TABLE TOP ECCENTRIC Coordinate System) as defined by . DICOM represents this value as a Continuous Rotation Angle in degrees.
126806 IEC61217 Table Top Lateral Position Lateral displacement of the table top, in mm (in the IEC TABLE TOP Coordinate System) as defined by .
126807 IEC61217 Table Top Longitudinal Position Longitudinal displacement of the table top, in mm (in the IEC TABLE TOP Coordinate system) as defined by .
126808 IEC61217 Table Top Vertical Position Vertical displacement of the table top, in mm (in the IEC TABLE TOP Coordinate System) as defined by .
126809 IEC61217 Gantry Continuous Roll Angle Rotation of the gantry (around the Y-axis of the IEC FIXED REFERENCE Coordinate System) as defined by . DICOM represents this value as a Continuous Rotation Angle in degrees.
126810 IEC61217 Gantry Continuous Pitch Angle Pitch angle of rotation of the gantry around the X-axis of the IEC GANTRY Coordinate System. This parameter is not specifically defined by , but is consistent with . DICOM represents this value as a Continuous Rotation Angle in degrees.
126811 IEC61217 Gantry Continuous Yaw Angle Yaw angle of rotation of the gantry around the Z-axis of the IEC GANTRY Coordinate System This parameter is not specifically defined by , but is consistent with . DICOM represents this value as a Continuous Rotation Angle in degrees.
126830 left first The body position of the imaging subject relative to the imaging equipment is with the subject's left side positioned towards the front of the equipment viewed from the front
126831 right first The body position of the imaging subject relative to the imaging equipment is with the subject's right side positioned towards the front of the equipment viewed from the front
126832 posterior first The body position of the imaging subject relative to the imaging equipment is with the subject's posterior (dorsal) side positioned towards the front of the equipment viewed from the front
126833 anterior first The body position of the imaging subject relative to the imaging equipment is with the subject's anterior (ventral) side positioned towards the front of the equipment viewed from the front
126850 ILCR The International Laboratory Code Registry (ILCR) of the Institute of Laboratory Animal Research (ILAR). See .
127001 Preclinical Small Animal Imaging Acquisition Context A description of the conditions present during acquisition of images of small animals during preclinical research.
127005 Animal handling during specified phase The conditions present related to the handling of an animal during a specified phase.
127006 Phase of animal handling A specified phase of handling of an animal (e.g., transport, preparation).
127010 Biosafety conditions A description of biosafety conditions (e.g., present during small animal handling for research).
127011 Reason for biosafety controls The reason that biosafety controls are in place.
127040 Heating conditions A description of heating conditions (e.g., present during small animal handling for research).
127050 Circadian effects A description of Circadian effects (e.g., present during small animal handling for research).
127060 Nose cone A form of face mask that fits over the nose used for delivery of inhalational anesthesia (usually for small animals)
127061 Nasal cannula Cannula inserted in the nose used for delivery of inhalational anesthesia or other inhaled gases.
127070 Retro-orbital route A route of administration of a substance via the retro-orbital venous sinus.Yardeni T et al. (2011). Retro-orbital injections in mice. Lab Animal, 40(5), 155-160. doi:10.1038/laban0511-155.
127101 In home cage The phase of handling of an animal that provides their normal environment between procedures.
127102 During transport The phase of handling of an animal that is transport between environments.
127103 Staging prior to imaging The phase of handling of an animal that is staging prior to an imaging procedure (e.g., after removal from their home environment and transport cage, and awaiting preparation, induction or imaging). During this phase the animals are not subject to intervention (e.g., injection, catheterization) (cf. 127104, DCM, "Preparation for imaging")).
127104 Preparation for imaging The phase of handling of an animal that is preparation prior to an imaging procedure that involves handling and intervention (e.g., such as injection, catheterization) (cf. 127103, DCM, "Staging prior to imaging")).
127110 Housing role The phase of handling of an animal during which the housing conditions are applicable.
127120 Animal housing The manner in which animals are housed.
127121 Animal room type The room type in which racks of animal cages are housed.
127122 Animal room identifier The identifier of the room in which racks of animal cages are housed.
127125 Housing manufacturer The manufacturer of the animal housing.
127126 Housing rack product name The manufacturer's product name of the animal housing rack.
127127 Housing rack product code The manufacturer's product code of the animal housing rack.
127128 Housing unit product name The manufacturer's product name of the animal housing unit (or bottom of unit if separate lid).
127129 Housing unit product code The manufacturer's product code of the animal housing unit (or bottom of unit if separate lid).
127130 Housing unit lid product name The manufacturer's product name of the animal housing unit lid.
127131 Housing unit lid product code The manufacturer's product code of the animal housing unit lid.
127140 Number of racks per room The number of animal housing racks per room.
127141 Number of housing units per rack The number of animal housing units per rack.
127142 Housing unit location in rack The location of the housing unit in the rack.
127143 Number of animals within same housing unit The number of animals in a single housing (e.g., in a single cage, or in an animal carrier for imaging).
127144 Sex of animals within same housing unit The sex of multiple animals contained in a single housing (cage).
127145 Sex of handler The sex of the animal handler(s).
127146 Mixed sex A group consisting of individuals of both sexes (both males and females).
127150 Total duration in housing The total period of time that a subject spends in specified housing conditions.
127151 Housing change interval The period of time between changes of housing conditions.
127152 Manual handling interval The period of time between episodes of manual handling of the subject.
127153 Housing unit movement A description of the manner in which the housing unit is moved (e.g., how a cage is transported).
127160 Housing unit width The width of the housing unit (e.g., cage).
127161 Housing unit height The height of the housing unit (e.g., cage).
127162 Housing unit length The length of the housing unit (e.g., cage).
127170 Housing individually ventilated Whether or not the housing unit (e.g., cage) is individually ventilated.
127172 Air changes How frequently the entire volume of air within a defined space is replaced (e.g., within an animal cage).
127175 Housing unit reuse Whether or not the housing unit has been previously used for different animals.
127177 Unused The device (e.g., animal housing unit aka. cage) has not previously been used for different animals.
127178 Reused The device (e.g., animal housing unit aka. cage) has previously been used for different animals.
127180 Bedding manufacturer The manufacturer of the bedding material.
127181 Bedding product name The manufacturer's product name of the bedding material.
127182 Bedding product code The manufacturer's product code of the bedding material.
127183 Bedding volume The volume of bedding material.
127184 Bedding mass The mass of bedding material.
127185 Bedding depth The depth of bedding material.
127190 Enrichment material Material provided to enrich the environment of a small animal for the purpose of reducing stress, improving health and/or improving reproducibility of results.
127191 Enrichment manufacturer The manufacturer of the material provided to enrich the environment of a small animal.
127192 Enrichment material present Whether or not material is provided to enrich the environment of a small animal for the purpose of reducing stress, improving health and/or improving reproducibility of results.
127193 Exerciser device present Whether or not an exerciser device is present.
127195 Shelter type The type of shelter provided for small animals within their housing.
127196 Shelter manufacturer The manufacturer of the small animal shelter.
127197 Shelter product name The manufacturer's product name of the small animal shelter.
127198 Shelter product code The manufacturer's product code of the small animal shelter.
127200 Feed manufacturer The manufacturer of the feed.
127201 Feed product name The manufacturer's product name of the feed.
127202 Feed product code The manufacturer's product code of the feed.
127205 Feed source The source of animal feed.
127210 Feedback temperature regulation Temperature is regulated by feedback from a temperature sensor used to control an active heating or cooling device.
127214 Total duration of light-dark cycle The total duration of single light-dark cycle (e.g., usually 24 hours).
127215 Lights on time of day The time of day when the lights are turned on.
127220 Igloo Igloo shaped small animal shelter
127221 Red translucent igloo Red translucent igloo-shaped small animal shelter
127230 Aspen chip bedding Animal bedding material made from aspen chips.
127231 Aspen shaving bedding Animal bedding material made from aspen shavings.
127232 Corn cob bedding Animal bedding material made from (milled) corn cobs.
127233 Paper-based bedding Animal bedding material made from paper.
127234 Pine chip bedding Animal bedding material made from pine chips.
127235 Pine shaving bedding Animal bedding material made from pine shavings.
127240 Carrier temperature sensor A device for measuring the temperature of the carrier (holder) used for small animal imaging as a means of monitoring or regulating the animal's temperature (e.g., a non-magnetic thermocouple embedded in or attached to the carrier for MRI).
127250 Forced air heater A method or device that uses forced hot air to maintain the body temperature of a subject.
127251 Heated imaging device An imaging device that contains an integrated method of temperature regulation for maintaining the body temperature of the imaging subject.
127252 Heated patient support A device that physically supports the patient and contains an integrated method of temperature regulation for maintaining the body temperature of the imaging subject (e.g., the carrier used for imaging a small animal such as a mouse).
127253 Heated water blanket A blanket that uses circulating hot water to maintain the body temperature of a subject.
127254 Pre-heated pad A pad that is pre-heated before use that is used to maintain the body temperature of a subject (e.g., pre-heated in a microwave or autoclave).
127255 Unheated No mechanism is used to maintain the body temperature of a subject.
127270 NIH31 NIH Open Formula Rat and Mouse Ration - 18% Crude Protein Autoclavable.Specification at .
127271 NIH07 NIH07 open-formula, natural-ingredient rodent diet.
127272 AIN76 AIN76 purified diet.
127273 AIN93G AIN93 growth diet.
127274 AIN93M AIN93 maintenance diet.
127290 Reverse osmosis purified water Water that has been purified by reverse osmosis.
127291 Reverse osmosis purified, HCl acidified water Water that has been purified by reverse osmosis and HCl acidified.
127300 Anesthesia Method Set Information about different anesthesia methods used during a procedure (from AQI Schema AnesthesiaMethodSetType.
127301 Anesthesia Method Information about a single anesthesia method used during a procedure (from AQI Schema AnesthesiaMethodType.
127302 Anesthesia Category Category of anesthesia technique used during a procedure (from AQI Schema AnesthesiaCategoryCodeType.
127303 Anesthesia SubCategory Details of anesthesia technique used during a procedure (from AQI Schema AnesthesiaMethodType.
127310 Airway Management Set Information about airway management used during a procedure (from AQI Schema AirwayManagementSetType.
127312 Airway Management Method Type of airway management used during a procedure (from AQI Schema AirwayManagementMethodCodeType.
127313 Airway Sub-Management Method Subtype of airway management of airway management used during a procedure (from AQI Schema AirwayManagementSubMethodCodeType.
127320 Medications Set Set of medications applied during the anesthesia (from AQI Schema MedicationsSetType.
127330 Carrier gas A gas that delivers an inhalational anesthetic to a subject (e.g., air, oxygen).
127370 Animal housing room A room for keeping and raising animals for observation or research (vivarium).
127371 Preparation room A room for preparing a subject (such as a research small animal) prior to a procedure (such as an imaging procedure).
127372 Imaging procedure room A room in which an imaging procedure is performed.
127390 Locally manufactured product A product that is locally manufactured (i.e., within the facility or institution).
127391 Food treat A food item that is out of the ordinary and provides pleasure.
127400 Exogenous substance A substance from a source external to a subject.
127401 Tissue of origin The tissue from which a substance originated.
127402 Taxonomic rank of origin The taxonomic rank value (e.g., genus, subgenus, species or subspecies) from which a substance originated.
127411 Strain An identifier of a group of animals that is genetically uniform.
127412 Strain description A description of a group of animals that is genetically uniform.
127413 Nomenclature A system of names or descriptions used in a particular field.
127414 Genetic modifications An identifier of a specific variation of a targeted gene or introduced transgene.
127415 Genetic modifications description A description of a specific variation of a targeted gene or introduced transgene.
127450 Stereotactic coordinates The three dimensional coordinates that identify a (usually small) target within the body.
127451 Position reference indicator The part of the imaging target that was used as a reference point associated with a specific Frame of Reference.The Position Reference Indicator may or may not coincide with the origin of the fixed frame of reference related to the Frame of Reference.For a Patient-related Frame of Reference, this is an anatomical reference point, often a well-known surface anatomical point.
127460 Tumor graft Tumor cells or tissue or other material obtained from a donor intended to be implanted in a research subject.
127801 Embryonic Kidney The kidney of an embryo.
127851 Human alpha synuclein preformed fibrils Preformed fibrils of human alpha synuclein.
127852 Mouse alpha synuclein preformed fibrils Preformed fibrils of mouse alpha synuclein.
127853 Human Tau preformed fibrils Preformed fibrils of human Tau.
127854 Mouse Tau preformed fibrils Preformed fibrils of mouse Tau.
127855 Non-ionic iodinated contrast agent An iodine containing X-Ray contrast agent that does not dissociate in water, therefore, is lower in osmolality, and has a significantly lower incidence of adverse reactions than ionic iodinated contrast agents.
127856 Heart valve flail Unrestricted motion of a heart valve.
127857 Glucose Measurement Date The date that a glucose measurement was performed.
127858 Glucose Measurement Time The time that a glucose measurement was performed.
127901 SPECT of whole body A nuclear medicine imaging procedure using a single photon emissive radionuclide with tomographic reconstruction, over an anatomical extent of the entire body.
127902 SPECT CT of whole body A nuclear medicine imaging procedure using a single photon emissive radionuclide with tomographic reconstruction combined with transmissive X-Ray computed tomography for attenuation compensation, over an anatomical extent of the entire body.
128001 Add Addendum to Report The task is to add an addendum to an existing report.
128002 Modality to Read The imaging study to be read involves the specified modality
128003 Reader Specialty The specialty of the reader of the imaging study
128004 Report Requested The type of report that is being requested.
128005 Final Report A final report is a report that is expected to contain all information and all the reportable findings.
128006 Abdominal Imaging Specialty A medical specialty concerned with abdominal imaging.
128007 Cardiac Imaging Specialty A medical specialty concerned with cardiac imaging.
128008 Head and Neck Imaging Specialty A medical specialty concerned with head and neck imaging.
128009 Musculoskeletal Imaging Specialty A medical specialty concerned with musculoskeletal imaging.
128010 Neurology Specialty A medical specialty concerned with neurology.
128011 Neuroradiologic Imaging Specialty A medical specialty concerned with neuroradiologic imaging.
128012 OB/Gyn Imaging Specialty A medical specialty concerned with obstetric and gynecologic imaging.
128013 Oncologic Imaging Specialty A medical specialty concerned with oncologic imaging.
128014 Oncology Specialty A medical specialty concerned with oncology.
128015 Thoracic Imaging Specialty A medical specialty concerned with thoracic imaging.
128016 Pediatric Imaging Specialty A medical specialty concerned with pediatric imaging.
128017 Vascular Imaging Specialty A medical specialty concerned with vascular imaging.
128040 FWP by GA, Campbell, 1991 Fetal body weight growth percentile estimated from gestational age by method of Campbell 1991.See Campbell WA, Nardi D, Vintzileos AM, Rodis JF, Turner GW, Egan JF. Transverse Cerebellar Diameter/Abdominal Circumference Ratio Throughout Pregnancy: A Gestational Age-Independent Method to Assess Fetal Growth. Obstetrics & Gynecology. 1991;77(6):893-6. Available at: .
128041 FWP by GA, Hadlock, 1991 Fetal body weight growth percentile estimated from gestational age by method of Hadlock 1991.See Hadlock FP, Harrist RB, Martinez-Poyer J. In utero analysis of fetal growth: a sonographic weight standard. Radiology. 1991 Oct 1;181(1):129-33. DOI:10.1148/radiology.181.1.1887021. Available at: .
128120 Plane through Superior Extent A plane passing through the superior extent (i.e., towards the head) of the referenced feature
128121 Plane through Inferior Extent A plane passing through the inferior extent (i.e., towards the feet) of the referenced feature
128122 Plane through Proximal Extent A plane passing through the proximal extent (i.e., towards the torso) of the referenced feature
128123 Plane through Distal Extent A plane passing through the distal extent (i.e., towards the end of the extremity) of the referenced feature
128124 Plane through Medial Extent A plane passing through the medial extent (i.e., towards the midline of the body) of the referenced feature
128125 Plane through Lateral Extent A plane passing through the lateral extent (i.e., away from the midline of the body) of the referenced feature
128126 Plane through Leftmost Extent A plane passing through the leftmost extent of the referenced feature
128127 Plane through Rightmost Extent A plane passing through the rightmost extent of the referenced feature
128128 Plane through Anterior Extent A plane passing through the anterior extent of the referenced feature
128129 Plane through Posterior Extent A plane passing through the posterior extent of the referenced feature
128130 Plane through Center A plane passing approximately through the center of the referenced feature
128137 Geometric Centerpoint The geometric center point of a feature, such as an organ, implanted device or morphologic anomaly.
128138 Center of Mass The center of mass of a feature, such as an organ, implanted device or morphologic anomaly
128139 Seed point Point in an image or space from which segmentation is initiated, e.g., by region growing.
128144 Impaired Renal Function The procedure is contraindicated for patients with impaired renal function.
128151 Laser Cross-hairs Positioning the patient based on alignment of laser cross-hairs.
128160 Acquired Volume The anatomical region represented in the acquired data.
128170 Abdominal Radiology Organizational department or section responsible for Abdominal Radiology
128171 Biomedical Engineering Organizational department or section responsible for Biomedical Engineering
128172 Cardiovascular Radiology Organizational department or section responsible for Cardiovascular Radiology
128173 Information Technology Organizational department or section responsible for Information Technology
128174 Medical Physics Organizational department or section responsible for Medical Physics
128175 Musculoskeletal Radiology Organizational department or section responsible for Musculoskeletal Radiology
128177 Pediatric Radiology Organizational department or section responsible for Pediatric Radiology
128179 Thoracic Radiology Organizational department or section responsible for Thoracic Radiology
128180 For RT Workflow Instances available as input for a general radiotherapeutic workflow.
128181 Diagnostic Source Images Instances used to make a diagnosis.
128182 Segmentation Result Instances created during a segmentation session.
128183 Registration Result Instances created during a spatial registration.
128184 Pre-Planning Result Instances created during preparation prior to planning.
128185 RT Prescription Result Instances created for prescription of a radiotherapeutic treatment.
128186 Dose Calculation Image Series Image instances that represent an image series that is intended to be the primary input for the dose calculation. Any parameters required for dose calculation (such as electron density) is derived from this series.
128187 Coordinate Alignment Image Series Image instances that represent an image series from which the display coordinate system for a radiotherapeutic treatment planning is derived. Typically this series does not provide the parameters required for the dose calculation.
128188 RT Treatment Simulation Result Instances created during the simulation of a radiotherapeutic treatment delivery session. May also include input objects actually used.
128189 RT Planning Result Instances created during the planning of a radiotherapeutic treatment. May also include input objects actually used.
128190 Dosimetric Result Instances created during the creation of the dosimetric result of a radiotherapeutic treatment plan. May also include input objects actually used.
128191 Patient Setup Verification Result Instances created during the verification of the patient’s treatment position. May also include input objects actually used.
128192 RT Treatment Session Result Instances created during the treatment session. May also include input objects actually used.
128193 RT Treatment Course Summary Instances created during a treatment course. May also include input objects actually used.
128194 RT Treatment QA Result Instances created during evaluation of the treatment delivery quality. May also include input objects actually used.
128195 For Diagnosis Instances available to make a diagnosis.
128196 For Segmentation Instances available for segmentation.
128197 For RT Prescription Instances available for prescribing a radiotherapeutic treatment delivery.
128198 For RT Treatment Planning Instances available for creating a radiotherapeutic treatment plan.
128199 For Plan Comparison Instances available for comparing plans.
128200 For RT Plan Summation Instances available to combine radiotherapeutic plans or doses.
128201 For Physician Review Instances available for review by a physician.
128202 For Physicist Review Instances available for review by a physicist.
128203 For Tumor Board Instances available for review of a tumor board.
128204 For Plan Quality Assurance Instances available to perform quality assurance of a radiotherapeutic treatment delivery plan.
128205 For Machine Quality Assurance Instances available to perform quality assurance of one of the hardware or software components involved in a radiotherapeutic treatment delivery.
128206 For Patient Setup Verification Instances available for verification of the patient treatment position.
128207 For Clinical Trial Submission Instances available for submission for a clinical trial study.
128208 For Tumor Registry Instances available for submission to a tumor registry.
128209 RT Workflow Input Used Instances used as an input of a general radiotherapeutic workflow.
128210 RT Prescription Input Used Instances used for prescribing a radiotherapeutic treatment delivery.
128211 RT Treatment Planning Input Used Instances used to create a radiotherapeutic treatment plan.
128212 RT Plan Summation Input Used Instances used to combine radiotherapeutic plans or doses.
128213 Physician Review Input Used Instances used for review by a physician.
128214 Physicist Review Input Used Instances used for review by a physicist.
128215 Plan Quality Assurance Input Used Instances used to perform quality assurance of a radiotherapeutic treatment delivery plan.
128216 Machine Quality Assurance Input Used Instances used to perform quality assurance of one of the hardware or software components involved in a radiotherapeutic treatment delivery.
128217 Patient Setup Verification Input Used Instances used during verification of the patient treatment position.
128218 Diagnosis Input Used Instances used to make a diagnosis.
128219 Contouring Input Used Instances used for segmentation.
128220 Plan Comparison Input Used Instances used for comparing plans.
128221 Tumor Board Input Used Instances used for review of a tumor board.
128222 Tumor Registry Input Used Instances submitted to a tumor registry.
128223 Clinical Trial Submission Input Used Instances submitted to a clinical trial study.
128224 Source measurement Measurement used as the source for derivation.
128225 Source report Report used as the source for derivation.
128226 Source raw data Raw Data used as the source for derivation.
128227 Source real world value map Real world value map used as the source for derivation.
128230 Pulse Sequence Name Name of an MR pulse sequence for annotation purposes. Potentially vendor-specific name.
128250 Structural image for image processing A structural image used for image processing.
128251 Flow image for image processing A flow image used for image processing.
128252 OCT-A amplitude decorrelation OCT angiography method that de-correlates the amplitudes between two consecutive B-scans from the narrowed spectral bands was computed, and all the decorrelation values within certain repeated B-scans were averaged to visualize blood vessels. Methods and algorithms for optical coherence tomography-based angiography: a review and comparison. Anqi Zhang ; Qinqin Zhang ; Chieh-Li Chen ; Ruikang K. Wang (2015). See http://biomedicaloptics.spiedigitallibrary.org/​article.aspx?​articleid=​2464650#​QuantitativeComparisons.
128253 OCT-A complex variance OCT angiography method based on variations in the complex (amplitude and phase) OCT signal from repeated B-scans at the same location. There are a number of factors that may cause a change in the OCT signal frequency relative to the signal due to static tissue background. These factors include, for example, the Doppler effect that induces optical frequency shift and the change in backscattering due to the particles that are moving in and out of the OCT-probe volume during imaging. The changes in signal frequency cause the changes in both the amplitude and the phase of the OCT signal. Comparison of the complex (amplitude and phase) signal from repeated B-scans at the same location provides an image that has higher contrast in areas of erythrocyte motion. This method is referred to as OCT-based micro-angiography - complex (OMAGC).
128254 OCT-A speckle variance OCT angiography method that analyzes the temporal or spatial statistics of the intensity of speckle from OCT images and identifies blood vessels.
128255 OCT-A correlation mapping OCT angiography method that differentiates flow regions. Static regions usually have high correlation values while flow regions have lower correlation values.
128256 Doppler OCT-A OCT angiography method that utilizes the Doppler phase resolved information to provide the velocity of flow. Sometimes referred to as the phase variance method.
128257 Retina depth encoded vasculature flow Image using pseudo colors to illustrate multiple OPTENF images obtained at various depth levels within the retina from the OPT flow volume.
128258 Retina depth encoded structural reflectance map Image using pseudo colors to illustrate multiple OPTENF images obtained at various depth levels within the retina from the OPT structural volume.
128259 Retina vasculature flow Image that illustrates the vasculature flow within the entire retina. Generated from the OPT flow volume with pixels approximately from inner limiting membrane (ILM) to photoreceptor inner segment/ellipsoid region (ISe).
128260 Retina structural reflectance map Image that illustrates the OCT structural reflectance within the entire retina. Generated from the OPT structural volume with pixels approximately from inner limiting membrane (ILM) to photoreceptor inner segment/ellipsoid region (ISe).
128261 Vitreous vasculature flow Image that illustrates the vasculature flow within the vitreous. Generated from the OPT flow volume with pixels approximately from a selected location anterior to ILM, to ILM. This space/potential space is referred clinically as the Vitreo-retinal Interface (VRI).
128262 Vitreous structural reflectance map Image that illustrates the OCT structural reflectance within the vitreous. Generated from the OPT structural volume with pixels approximately from a selected location that is anterior to ILM, to ILM. This space/potential space is referred clinically as the Vitreo-retinal Interface (VRI).
128263 Radial peripapillary vasculature flow Image that illustrates the OCT vasculature flow within the RNFL around the optic disk. Generated from the OPT flow volume with pixels approximately from ILM to the outer boundary of the RNFL.
128264 Radial peripapillary structural reflectance map Image that illustrates the OCT structural reflectance within the RNFL around the optic disk. Generated from the OPT structural volume with pixels approximately from ILM to the outer boundary of the RNFL.
128265 Superficial retina vasculature flow Image that illustrates the vasculature flow within the anterior layers of retina. Generated from the OPT flow volume with pixels approximately from ILM to ganglion cell layer/inner plexiform layer (GCL/IPL).
128266 Superficial retina structural reflectance map Image that illustrates the OCT structural reflectance within the anterior layers of retina. Generated from the OPT structural volume with pixels approximately from ILM to ganglion cell layer/inner plexiform layer (GCL/IPL).
128267 Middle inner retina vasculature flow Image that illustrates the vasculature flow in the capillaries that connect the superficial and deeper capillary beds. Generated from the OPT flow volume with pixels approximately at the level of the IPL. Sometimes referred to as the intermediate retina flow.
128268 Middle inner structural reflectance map Image that illustrates the OCT structural reflectance in the capillaries that connect the superficial and deeper capillary beds. Generated from the OPT structural volume with pixels approximately at the level of the IPL. Sometimes referred to as the intermediate retina flow.
128269 Deep retina vasculature flow Image that illustrates the vasculature flow at the level of the plexiform layers within the retina. Generated from the OPT flow volume with pixels approximately from inner plexiform layer (IPL) to outer plexiform layer (OPL).
128270 Deep retina structural reflectance map Image that illustrates the structural reflectance at the level of the plexiform layers within the retina. Generated from the OPT structural volume with pixels approximately from inner plexiform layer (IPL) to outer plexiform layer (OPL).
128271 Outer retina vasculature flow Image that illustrates the vasculature flow at the level of the posterior layers of the retina (outer retina). Generated from the OPT flow volume with pixels approximately in the translucent layers, from OPL to ISe. Sometimes referred to as flow in the deep avascular structure. Note For normal eyes, this image would not show detectable vascular flow.
128272 Outer retina structural reflectance map Image that illustrates the structural reflectance at the level of the posterior layers of the retina (outer retina). Generated from the OPT structural volume with pixels approximately in the translucent layers, from OPL to ISe.
128273 Choriocapillaris vasculature flow Image that illustrates the vasculature flow at the level of the chroriocapillaris. Generated from the OPT flow volume with pixels approximately below the retinal pigment epithelium (RPE) encompassing the thickness of choriocapillaris.
128274 Choriocapillaris structural reflectance map Image that illustrates the structural reflectance at the level of the chroriocapillaris. Generated from the OPT structural volume with pixels approximately below the retinal pigment epithelium (RPE) encompassing the thickness of choriocapillaris.
128275 Choroid vasculature flow Image that illustrates the vasculature flow at the level of the choroid. Generated from the OPT flow volume with pixels approximately below RPE, encompassing the thickness of choroid.
128276 Choroid structural reflectance map Image that illustrates the structural reflectance at the level of the choroid. Generated from the OPT structural volume with pixels approximately below RPE, encompassing the thickness of choroid.
128277 Whole eye vasculature flow Image that illustrates the vasculature flow at the entire posterior segment, including retina and choroid. Generated from the OPT flow volume with pixels encompassing the entire OCT scan.
128278 Whole eye structural reflectance map Image that illustrates the structural reflectance from the entire posterior segment, including retina and choroid. Generated from the OPT structural volume with pixels encompassing the entire OCT scan.
128279 Cube B-scan pattern A series of densely spaced, parallel B-scans of the same length covering an area.
128280 Raster B-scan pattern A series of sparsely spaced, parallel B-scans of the same length covering an area.
128281 Line B-scan pattern A single line B-scan.
128282 Radial B-scan pattern A series of B-scans arranged in a radial pattern of the same length covering an area.
128283 Cross B-scan pattern A pair of horizontal and vertical B-scans in a cross pattern.
128284 Circle B-scan pattern A single circular pattern B-scan.
128285 Concentric circle B-scan pattern A series of concentric circular pattern B-scans with various diameters.
128286 Circle-raster B-scan pattern A series of concentric circular pattern B-scans with various diameters combined with a series of raster B-scan patterns.
128287 Circle-radial B-scan pattern A series of concentric circular pattern B-scans with various diameters combined with a series of radial B-scan patterns.
128288 Grid B-scan pattern A series of vertical and horizontal B-scans.
128289 Outer surface of RNFL Retinal surface located approximately at the outer boundary of the retinal nerve fiber layer (RNFL).
128290 Outer surface of GCL Retinal surface approximately at the outer boundary of the Ganglion Cell Layer (GCL).
128291 Outer surface of IPL Retinal surface located approximately at the outer boundary of the Inner Plexiform Layer (IPL).
128292 Outer surface of INL Retinal surface located approximately at the outer boundary of the Inner Nuclear Layer (INL).
128293 Outer surface of OPL Retinal surface located approximately at the outer boundary of the Outer Plexiform Layer (OPL).
128294 Outer surface of HFL Retinal surface located approximately at the outer boundary of the Henle Fiber Layer (HFL) when present.
128295 Surface between Inner and Outer Segments of the photoreceptors Retinal surface approximately located at the boundary between the Inner Segments and Outer Segments of the photoreceptors.
128296 Surface of the interdigitating zone between retina and RPE Retinal surface located approximately at the retina-RPE interdigitating zone when present.
128297 Anterior surface of the RPE Retinal surface located approximately at the anterior surface of the Retinal Pigment Epithelium (RPE).
128298 Surface of the center of the RPE Retinal surface located approximately at the center of the Retinal Pigment Epithelium (RPE).
128299 Posterior surface of the RPE Retinal surface located approximately at the posterior surface of the Retinal Pigment Epithelium (RPE).
128300 Outer surface of the BM Retinal surface located approximately at the outer boundary of the Bruch’s Membrane (BM).
128301 Surface of the choroid-sclera interface Retinal surface located approximately at the choroid-sclera interface (SC).
128302 Outer surface of the CC Retinal surface located approximately at the outer boundary of the choriocapillaris (CC).
128303 OCT B-scan analysis Values are derived from performing analysis on OCT B-scans
128304 OCT-A one-sided ratio (lesser) OCT angiography method that utilizes a one-sided ratio on a pixel by pixel basis between various combinations of B-scan repetitions. The ratio is inverted when necessary such that values are less than or equal to one. Individual ratio calculations are averaged or combined across eligible frame combinations for each pixel in the OCT image.
128305 OCT-A one-sided ratio (greater) OCT angiography method that utilizes a one-sided ratio on a pixel by pixel basis between various combinations of B-scan repetitions. The ratio is inverted when necessary such that values are greater than or equal to one. Individual ratio calculations are averaged or combined across eligible frame combinations for each pixel in the OCT image.
128401 Patient Radiation Dose Report Report title for the report of estimated absorbed energy from ionizing radiation to a patient.
128402 Radiation Dose Estimate Estimate of absorbed energy from ionizing radiation.
128403 Radiation Dose Estimate Name Name used to identify a radiation dose estimate.
128404 Anthropomorphic Model A mathematical description of a patient model for estimating radiation dose that describes or is thought of as having a human form or human attributes.
128405 Breast Thickness Thickness of the breast.
128406 BREP Radiation Transport Model Boundary based representation of the model for the estimation of radiation transport and absorbed dose in materials.
128407 DgN Normalized Mean Glandular Dose (DgN) is the conversion value used to calculate the absorbed dose from radiation to the fibroglandular tissue component of the breast from the exposure in air.
128408 Patient AP Dimension The size of a patient in the anterior-posterior dimension.
128409 Patient Lateral Dimension The size of a patient in the lateral dimension.
128410 SSDE Conversion Factor Conversion factor for Size Specific Dose Estimate (SSDE) calculations from CTDIvol.
128411 Backscatter Scattering of radiation in a direction opposite to that of the incident radiation.
128412 Radiation Dose Estimate Representation The description of the representation of the estimated absorbed energy to an organ, a set of organs or the whole body, e.g., surface segmentation, mesh, parametric map, RT dose , Secondary Capture SOP Instances, etc.
128413 Distribution Representation The form of the representation used to describe the distribution of the radiation dose.
128414 Radiation Dose Representation Data The absorbed energy data estimated by the method.
128415 Radiation Dose Estimate Methodology The methodology and parameters used to estimate the radiation dose to an organ, the whole body or a phantom.
128416 SR Instance Used Reference to an SR instance used.
128417 Patient Model Type The type of model used to define the shape, size, location of objects, etc. to represent a patient or phantom for use in radiation transport analysis.
128418 Simple Object Model A simple object (e.g., cylinder) used to model a patient or organ.
128420 Radiation Transport Model Type The type of model used to estimate energy transport and absorbed dose in materials.
128421 Geometric Radiation Transport Model A model that uses geometrical shapes for the estimation of radiation transport and absorbed dose in materials.
128422 Voxelized Radiation Transport Model A model that uses volumetric elements for the estimation of radiation transport and absorbed dose in materials.
128423 Mesh Radiation Transport Model A model that uses a mesh structure representation for the estimation of radiation transport and absorbed dose in materials.
128424 NURBS Radiation Transport Model A model that uses surfaces of a non-uniform rational B-spline (NURBS) based representation for the estimation of radiation transport and absorbed dose in materials.
128425 Patient Radiation Dose Model Data The data from the model used to estimate radiation dose to a patient or organ.
128426 Patient Radiation Dose Model Reference Rationale or reference to the methodology for the model used in the estimation of radiation dose.
128427 Patient Model Demographics The demographics for which the patient model used by the radiation dose estimation method is intended.
128428 Model Minimum Age The minimum age used in the patient model in the radiation dose estimation method.
128429 Event UID Used Unique Identifier of an event used.
128430 Model Maximum Age The maximum age used in the patient model in the radiation dose estimation method.
128431 Beam Block A material placed in the radiation beam that is used to completely attenuate the beam in a specific region of the field of view.
128433 Tissue Air Ratio Ratio of the absorbed dose at a given depth in tissue to the absorbed dose at the same point in air.
128434 Radiation Dose Estimate Parameters The parameters used in the algorithms for determining the radiation dose to a patient, organs, or any material.
128436 Radiation Dose Composite Parameters Reference to the SOP Instance that describes the parameters and values used in the algorithms for determining the radiation dose to a patient, organs, or any material.
128437 Model Patient Sex The sex used in the patient model in the radiation dose estimation method.
128438 Model Minimum Weight The minimum weight used in the patient model in the radiation dose estimation method.
128439 Model Minimum Height The minimum height used in the patient model in the radiation dose estimation method.
128441 Model Maximum Weight The maximum weight used in the patient model in the radiation dose estimation method.
128442 Model Maximum Height The maximum height used in the patient model in the radiation dose estimation method.
128444 Spatial Registration Reference Reference to the Spatial Registration instance or Deformable Spatial Registration instance.
128446 Registration Method Name of the method used to register the frame of reference for two or more sets of data.
128447 Spatial Fiducials Reference to Spatial Fiducials SOP Instance.
128452 Correction Factor A factor used to make an adjustment to a calculation to account for deviations.
128453 Curve Fit Parameter A value used in a mathematical function to create a curve or a function that approximates a set of data.
128455 Homogeneity Factor A value used to describe the uniformity or composition of data or a material that relates to the same degree of variability.
128456 Patient Model Registration The spatial registration used in the patient model in the radiation dose estimation method.
128457 X-Ray Beam Attenuator Attenuator in the radiation beam that may alter the estimated radiation dose to the patient, organs, or phantoms.
128458 Attenuator Category The type of object in the radiation beam that may alter the estimated radiation dose to the patient, organs, or phantoms.
128459 Table The table a patient is sitting, standing, or lying on and that is in the radiation beam such that it may alter the estimated radiation dose to the patient, organs, or phantoms.
128460 Table Core The core material of a table a patient is sitting, standing, or lying on and that is in the radiation beam such that it may alter the estimated radiation dose to the patient, organs, or phantoms.
128461 Table Outer Liner The outer shell of a table a patient is sitting, standing, or lying on and that is in the radiation beam such that it may alter the estimated radiation dose to the patient, organs, or phantoms.
128462 Table Pad The padding on a table a patient is sitting, standing, or lying on and that is in the radiation beam such that it may alter the estimated radiation dose to the patient, organs, or phantoms.
128464 Radiation Dose Estimation Parameter Type Parameters used in mathematical, simulation, or empirical calculations for radiation dose estimation.
128465 Equivalent Attenuator Material The equivalent material used to estimate the reduction in radiation intensity.
128468 Attenuator Description An explanation of the actual attenuator material used in the estimation of radiation dose.
128469 Equivalent Attenuator Thickness The thickness of a specified material that provides the same attenuation as the actual attenuator.
128470 X-Ray Attenuator Model Data The stored data from the model used to represent the X-Ray beam attenuator.
128472 X-Ray Beam Attenuator Model Model of the attenuator used in the estimation of radiation dose.
128474 X-Ray Beam Attenuator Model Reference Reference to the methodology or rationale for the model of the beam attenuator used in the estimation of radiation dose.
128475 X-Ray Beam Attenuator Model Registration Spatial registration of the beam attenuator model.
128476 Radiation Dose Estimate Method The container for the radiation dose estimation methods and parameters.
128477 Radiation Dose Estimate Method Type Type of method used to estimate the radiation dose to a patient, organs or phantoms.
128479 Tabular Data Algorithm Algorithms that use a table of values indexed by a key.
128480 Analytical Algorithm Algorithms that use mathematical models that have a deterministic result.
128481 Empirical Algorithm Algorithms that use mathematical models that use parameters derived from observation.
128482 Radiation Dose Estimate Method Reference A reference to the methodology or rationale for the estimation methodology used for the estimation of radiation dose.
128484 Isodose Representation of radiation dose of equal intensity as a surface, curve, or line.
128485 Skin Dose Map Representation of radiation dose intensity at the surface on the skin.
128487 3D Dose Map Representation of radiation dose as a 3D shape or object.
128488 Dose Gradient Representation of the change in radiation dose with respect to the change in another variable. Often represented as a change with respect to time or distance.
128492 Physical Support Material that is in radiation beam that is used to provide physical support to the patient or other objects.
128494 Patient Segmented Model A model for estimating radiation dose defined from the actual patient anatomy or characteristics.
128496 Dose Point Cloud Radiation dose represented as a distribution of points.
128497 Measured Radiation Dose The measured amount of energy that is deposited in a material by ionizing radiation.
128500 Patient Radiation Dose Model A computational representation of a human body or other object used to simulate the attenuation of radiation in human tissue.
128511 Reference to Uncertainty Determination Method A reference to the methodology used to determine the uncertainty in the estimation of radiation dose.
128512 Equivalent Dose Absorbed dose to a tissue or organ multiplied by a quality factor to normalize the dose to the type of radiation that is depositing the dose.
128513 Absorbed Dose Energy from ionizing radiation absorbed per unit mass.
128522 Normalization Factor A factor that is used to make an adjustment to a calculation to normalize the data.
128523 Offset Factor A factor that is used to make an adjustment to a calculation to translate or move the data in a defined manner.
128526 Tissue Fraction The amount of a specific tissue content, either mass or volume, in a material.
128527 Distance Correction A correction factor for a measurement of distance or location.
128528 Conversion Factor A numerical ratio to express a measurement from one unit to another unit.
128531 Maximum Absorbed Radiation Dose The largest absorbed radiation dose amount estimated.
128532 Minimum Absorbed Radiation Dose The smallest absorbed radiation dose value estimated.
128533 Mean Absorbed Radiation Dose The average value of the absorbed radiation dose estimated.
128534 Mode Absorbed Radiation Dose The absorbed radiation dose value estimated that occurs most frequently.
128535 Maximum Equivalent Radiation Dose The largest equivalent radiation dose value estimated.
128536 Minimum Equivalent Radiation Dose The smallest equivalent radiation dose value estimated.
128537 Mean Equivalent Radiation Dose The average value of the equivalent radiation dose estimated.
128538 Mode Equivalent Radiation Dose The equivalent radiation dose value estimated that occurs most frequently.
128539 Median Absorbed Radiation Dose The central value of the absorbed radiation dose estimated.
128540 Median Equivalent Radiation Dose The central value of the equivalent radiation dose estimated.
128551 Is Repeated Acquisition This acquisition of data (e.g., for constructing an image) is a repeat of an earlier acquisition that was for some reason unsatisfactory.
128552 Reason for Repeating Acquisition The reason that data (e.g., for constructing an image) was acquired again.
128553 Patient motion The acquired data is unsatisfactory because the patient moved.
128554 Suboptimal contrast timing The acquired data is unsatisfactory because the contrast timing was not adequate.
128601 Appropriate for the indications The protocol is appropriate for the indications recorded in the protocol instance.
128602 Consistent with labeling of the device The protocol is consistent with the regulatory product labeling of the device recorded in the protocol instance.
128603 Approved for use at the institution The protocol is approved for use at the institution recorded in the protocol instance.
128604 Approved for use in the clinical trial The protocol is approved for use in the clinical trial recorded in the protocol instance.
128605 Approved for use on pregnant patients The protocol is specifically approved for use on pregnant patients.
128606 Appropriate for the device The protocol is appropriate for execution on the device recorded in the protocol instance (which may identify an individual device by serial number or may identify a family of devices). I.e. the protocol has incorporated model-specific parameters and optimizations as necessary.
128607 Inside operational limits of the device The protocol specifies parameters that are within the operational limits of the device recorded in the protocol instance. I.e. execution of the protocol is not expected to damage or exceed the operational limits of the device.
128608 Optimized for the device instance The protocol is optimized for the characteristics of the specific instance of the device recorded in the protocol instance. I.e. the protocol has incorporated model-specific parameters and optimizations as necessary.
128609 Disapproved for any use The protocol is explicitly disapproved, or approval of the protocol has been withdrawn.
128610 Deprecated protocol The protocol is no longer to be used. E.g. it has been replaced by another protocol.
128611 Approved for experimental use The protocol is approved for use in experimental procedures.
128612 Disapproved for experimental use The protocol is disapproved for use in experimental procedures.
128613 Eligible for reimbursement The protocol is understood to be eligible for reimbursement by a given payer.
128614 Eligible for reimbursement on per patient basis The protocol is understood to be eligible for reimbursement on a per patient basis by a given payer.
128615 Ineligible for reimbursement The protocol is understood to be ineligible for reimbursement by a given payer.
128617 Disapproved for use on pregnant patients The protocol is explicitly disapproved for use on pregnant patients.
128618 Inappropriate for the device The protocol is inappropriate for execution on the device recorded in the protocol instance (which may identify an individual device by serial number or may identify a family of devices).
128619 Outside operational limits of the device The protocol specifies parameters that are not within the operational limits of the device recorded in the protocol instance. I.e. execution of the protocol may damage or exceed the operational limits of the device.
128620 Not optimized for the device instance The protocol is not optimized for the characteristics of the specific instance of the device recorded in the protocol instance.
128621 Inappropriate for the indications The protocol is inappropriate for the indications recorded in the protocol instance.
128622 Inconsistent with labeling of the device The protocol is inconsistent with the regulatory product labeling of the device recorded in the protocol instance.
128623 Disapproved for use at the institution The protocol is disapproved for use at the institution recorded in the approval instance.
128624 Disapproved for use in the clinical trial The protocol is disapproved for use in the clinical trial recorded in the protocol instance.
128670 Head of Radiology The senior ranking radiologist in the organization
128671 Chair of Protocol Committee The chair of a committee tasked with reviewing and approving protocols in the organization.
128673 Administrator of Radiology Department The administrative head of a department that provides radiology services.
128674 Lead Radiologic Technologist The senior ranking radiologic technologist in the organization.
128675 Head of Cardiology The senior ranking cardiologist in the organization.
128676 Representative of Protocol Committee A representative of a committee tasked with reviewing and approving protocols in the organization.
128677 Representative of Ethics Committee A representative of a committee tasked with evaluating medical ethics. E.g. Institutional Review Board.
128701 3D Gel A volume of gel that changes physical characteristics when exposed to ionizing radiation.
128702 Diode Array A number of semiconductor devices that generates current when exposed to ionizing radiation. The devices are arranged systematically in a regular pattern.
128703 Ion Chamber Array A number of devices that measures charge from the ions produced in a medium when exposed to ionizing radiation. The devices are arranged systematically in a regular pattern.
128704 Diode A semiconductor device that generates current when exposed to ionizing radiation.
128705 Liquid Ion Chamber An ion chamber that uses a liquid as the medium.
128706 OSLD Optically Stimulated Luminescent Dosimeter. It is a crystal that when exposed to green light, emits blue light in proportion to the amount of ionizing radiation it has been exposed to.
128707 Ion Chamber A device that measures charge from the ions produced in a medium when exposed to ionizing radiation.
128708 Diamond Detector A semiconductor detector that uses diamond as the medium.
128709 RPLGD A radiophotoluminescence glass dosimeter. It is a solid state cumulative radiation dosimeter usually made of silver-activated phosphate glass. The silver atoms act as radiophotoluminescence centers excited by ionizing radiation. The number of centers excited is proportional to the absorbed dose to the RPLGD.
128710 For Teaching File Export Instances that have been selected for export to a teaching file.
128711 For Clinical Trial Export Instances that have been selected for export for a clinical trial.
128712 Additional Teaching File Information The title of a document containing additional teaching file information.
128713 For Research Collection Export Instances that have been selected for export to a research collection.
128714 For Publication Export Instances that have been selected for export for publication.
128715 Delay export until final report is available Delay export until final report is available.
128716 Delay export until clinical information is available Delay export until clinical information is available.
128717 Delay export until confirmation of diagnosis is available Delay export until confirmation of diagnosis is available.
128718 Delay export until histopathology is available Delay export until histopathology is available.
128719 Delay export until other laboratory results are available Delay export until other laboratory results are available.
128720 Delay export until patient is discharged Delay export until patient is discharged.
128721 Delay export until patient dies Delay export until patient dies.
128722 Delay export until expert review is available Delay export until expert review is available.
128723 Teaching File Category The category that describes the subject matter of a teaching file.
128724 Level of Difficulty The level of difficult that the material represents.
128725 Primary level The teaching material is of a primary level of difficulty.
128726 Intermediate level The teaching material is of an intermediate level of difficulty.
128727 Advanced level The teaching material is of an advanced level of difficulty.
128728 Musculoskeletal imaging subject matter The subject matter pertains to musculoskeletal imaging.
128729 Pulmonary imaging subject matter The subject matter pertains to pulmonary imaging.
128730 Cardiovascular imaging subject matter The subject matter pertains to cardiovascular imaging.
128731 Gastrointestinal imaging subject matter The subject matter pertains to gastrointestinal imaging.
128732 Genitourinary imaging subject matter The subject matter pertains to genitourinary imaging.
128733 Neuroimaging subject matter The subject matter pertains to neuroimaging .
128734 Vascular and interventional imaging subject matter The subject matter pertains to vascular and interventional imaging.
128735 Nuclear medicine imaging subject matter The subject matter pertains to nuclear medicine imaging.
128736 Ultrasound imaging subject matter The subject matter pertains to ultrasound imaging.
128737 Pediatric imaging subject matter The subject matter pertains to pediatric imaging.
128738 Breast imaging subject matter The subject matter pertains to breast imaging.
128739 UDI The entire Human Readable Form of the Unique Device Identifier as defined by the Issuing Agency.
128740 Longitudinal Temporal Offset from Event An offset in time from a particular event of significance. In the context of a clinical trial, this is often the time since enrollment, or the baseline imaging study.
128741 Longitudinal Temporal Event Type The type of event to which a temporal offset is relative.
128750 Equipment Landmark A well-known landmark of the equipment that is visible by the operator.
128751 Center of Table Head An equipment landmark on the X-Ray Table head located on the table top plane, centered in the left-right direction of the table.
128752 Equipment Landmark X Position The X coordinate of the Equipment Landmark in the Table Coordinate System.
128753 Equipment Landmark Z Position The Z coordinate of the Equipment Landmark in the Table Coordinate System.
128754 Patient Location Fiducial A patient fiducial used to establish the patient location relative to equipment.
128756 Equipment Landmark to Patient Fiducial Z Distance The distance in the Z direction from the Equipment Landmark to the Patient Location Fiducial in the Table Coordinate System. Positive when the direction from the Equipment Landmark to the Patient Location Fiducial lies in the positive Z direction.
128757 Positioner Isocenter Primary Angle Angle in the XY plane of the isocenter reference system between the Y axis and a plane containing the Z axis and the X-Ray center beam (deg).
128758 Positioner Isocenter Secondary Angle Angle, in the plane containing the Z axis of the isocenter reference system and the X-Ray center beam, between the XY plane and the X-Ray center beam (deg).
128759 Positioner Isocenter Detector Rotation Angle Rotation of the X-Ray detector plane (deg).
128760 Positioner Isocenter Primary End Angle Position of the X-Ray center beam in the isocenter reference system in the X direction (deg) at the end of an irradiation event.
128761 Positioner Isocenter Secondary End Angle Position of the X-Ray center beam in the isocenter reference system in the Z direction (deg) at the end of an irradiation event.
128762 Positioner Isocenter Detector Rotation End Angle Rotation of the X-Ray detector plane (deg) at the end of an irradiation event.
128763 Table Head Tilt End Angle Angle of the head-feet axis of the table (deg) relative to the horizontal plane at the end of an irradiation event.
128764 Table Horizontal Rotation End Angle Rotation of the table in the horizontal plane (deg) at the end of an irradiation event.
128765 Table Cradle Tilt End Angle Angle of the left-right axis of the table (deg) relative to the horizontal plane at the end of an irradiation event.
128766 Table X Position to Isocenter X position of the Table Reference Point with respect to the Isocenter (mm).
128767 Table Y Position to Isocenter Y position of the Table Reference Point with respect to the Isocenter (mm).
128768 Table Z Position to Isocenter Z position of the Table Reference Point with respect to the Isocenter (mm).
128769 Table X End Position to Isocenter X position of the Table Reference Point with respect to the Isocenter (mm) at the end of an irradiation event.
128770 Table Y End Position to Isocenter Y position of the Table Reference Point with respect to the Isocenter (mm) at the end of an irradiation event.
128771 Table Z End Position to Isocenter Z position of the Table Reference Point with respect to the Isocenter (mm) at the end of an irradiation event.
128772 Reference Basis The anatomical feature or point of reference on which the reference location is based.
128773 Reference Geometry Characterizes the geometry of the reference location (e.g., a plane or point).
128774 Person Observer's Login Name Login name (user ID) of human observer who created the observations.
128775 Identifier within Person Observer's Role An alphanumeric designator of an individual within a role.
128776 Gray Level Run Length Matrix The tabulation of gray level run lengths in a particular direction in an image. Abbreviated GLRLM.See .
128777 Gray Level Size Zone Matrix A tabulation of counts of the number of groups of connected voxels with a specific discretized gray level value and size. Abbreviated GLSZM.See .
128778 Gray Level Distance Zone Matrix A tabulation of counts of the number of groups (or zones) of linked voxels that share a specific discretised grey level value and possess the same distance to ROI edge. Abbreviated GLDZM.See .
128779 Neighbourhood Grey Tone Difference Matrix A matrix containing the sum of grey level differences of pixels/voxels with a discretised grey level and average discretised grey level of neighbouring pixels/voxels within a specified Chebyshev distance. Abbreviated NGTDM.See .
128780 Neighbouring Grey Level Dependence Matrix A tabulation of the counts of dependent (within a specified coarseness parameter) neighbouring discretised grey levels within a specified Chebyshev distance. Abbreviated NGLDM.See .
128781 Joint Maximum of GLCM The probability corresponding to the most common gray level co-occurrence in the GLCM. Abbreviated MAX.See Fcm.joint.max in .
128782 Joint Average of GLCM The gray level weighted sum of joint probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.joint.avg in .
128783 Joint Variance of GLCM The sum of squares of the difference from the joint average of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.joint.var in .
128784 Difference Average of GLCM The average for the diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.diff.avg in .
128785 Difference Variance of GLCM The variance for the diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.diff.var in .
128786 Difference Entropy of GLCM The entropy for the diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.diff.entr in .
128787 Sum Average of GLCM The average for the cross-diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.sum.avg in .
128788 Sum Variance of GLCM The variance for the cross-diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.sum.var in .
128789 Sum Entropy of GLCM The entropy for the cross-diagonal probabilities of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.sum.entr in .
128790 Inverse Difference of GLCM The inverse difference of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.inv.diff in .
128791 Inverse Difference Normalized of GLCM The normalized inverse difference of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.inv.diff.norm in .
128792 Inverse Difference Moment Normalized of GLCM The normalized inverse difference moment of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.inv.diff.mom.norm in .
128793 Inverse Variance of GLCM The inverse variance of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.inv.var in .
128794 Autocorrelation of GLCM The autocorrelation of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.auto.corr in .
128795 Cluster Tendency of GLCM The cluster tendency of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.clust.tend in .
128796 Cluster Shade of GLCM The cluster shade of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.clust.shade in .
128797 Cluster Prominence of GLCM The cluster prominence of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.clust.prom in .
128798 First Measure of Information Correlation of GLCM The first measure of information correlation of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.info.corr.1 in .
128799 Second Measure of Information Correlation of GLCM The second measure of information correlation of a Gray Level Co-occurrence Matrix (GLCM).See Fcm.info.corr.2 in .
128801 Short Runs Emphasis A measure of the distribution of short runs in a gray level run length matrix. Abbreviated SRE.See Frlm.sre in .
128802 Long Runs Emphasis A measure of the distribution of long runs in a gray level run length matrix. Abbreviated LRE.See Frlm.lre in .
128803 Low Gray Level Run Emphasis A measure of the distribution of low gray level values in a gray level run length matrix. Abbreviated LGRE.See Frlm.lgre in .
128804 High Gray Level Run Emphasis A measure of the distribution of high gray level values in a gray level run length matrix. Abbreviated HGRE.See Frlm.hgre in .
128805 Short Run Low Gray Level Emphasis A measure of the joint distribution of short runs and low gray level values in a gray level run length matrix. Abbreviated SRLGE.See Frlm.srlge in .
128806 Short Run High Gray Level Emphasis A measure of the joint distribution of short runs and high gray level values in a gray level run length matrix. Abbreviated SRHGE.See Frlm.srhge in .
128807 Long Run Low Gray Level Emphasis A measure of the joint distribution of long runs and low gray level values in a gray level run length matrix. Abbreviated LRLGE.See Frlm.lrlge in .
128808 Long Run High Gray Level Emphasis A measure of the the joint distribution of long runs and high gray level values in a gray level run length matrix. Abbreviated LRHGE.See Frlm.lrhge in .
128809 Gray Level Nonuniformity in Runs A measure of the similarity of gray level values throughout the image in a gray level run length matrix. Abbreviated RLM.GLNU.See Frlm.glnu in .
128810 Gray Level Nonuniformity in Runs Normalized A normalized measure of the similarity of gray level values throughout the image in a gray level run length matrix.See Frlm.glnu.norm in .
128811 Run Length Nonuniformity A measure of the the similarity of the length of runs throughout the image in a gray level run length matrix. Abbreviated RLNU.See Frlm.rlnu in .
128812 Run Length Nonuniformity Normalized A normalized measure of the the similarity of the length of runs throughout the image in a gray level run length matrix.See Frlm.rlnu.norm in .
128813 Run Percentage A measure of the homogeneity and distribution of runs of an image in a specific direction in a gray level run length matrix. Abbreviated RPC.See Frlm.r.perc in .
128814 Gray Level Variance in Runs The variance in runs for the gray levels in a gray level run length matrix.See Frlm.gl.var in .
128815 Run Length Variance The variance in runs for run lengths in a gray level run length matrix.See Frlm.rl.var in .
128816 Run Entropy The entropy of runs in a gray level run length matrix.See Frlm.rl.entr in .
128821 Small Zone Emphasis A feature that emphasizes small zones from a gray level size zone matrix. Abbreviated SZE.See Fszm.sze in .
128822 Large Zone Emphasis A feature that emphasizes large zones from a gray level size zone matrix. Abbreviated LZE.See Fszm.lze in .
128823 Low Gray Level Zone Emphasis A feature that emphasizes low gray level zones from a gray level size zone matrix. Abbreviated LGZE.See Fszm.lgze in .
128824 High Gray Level Zone Emphasis A feature that emphasizes high gray level zones from a gray level size zone matrix. Abbreviated LGZE.See Fszm.hgze in .
128825 Small Zone Low Gray Level Emphasis A feature that emphasizes small zone sizes and low gray levels from a gray level size zone matrix. Abbreviated SZLGE.See Fszm.szlge in .
128826 Small Zone High Gray Level Emphasis A feature that emphasizes small zone sizes and high gray levels from a gray level size zone matrix. Abbreviated SZHGE.See Fszm.szhge in .
128827 Large Zone Low Gray Level Emphasis A feature that emphasizes large zone sizes and low gray levels from a gray level size zone matrix. Abbreviated LZLGE.See Fszm.lzlge in .
128828 Large Zone High Gray Level Emphasis A feature that emphasizes large zone sizes and high gray levels from a gray level size zone matrix. Abbreviated LZHGE.See Fszm.lzhge in .
128829 Gray Level Nonuniformity of Zone Counts The distribution of zone counts over the gray values in a gray level size zone matrix. Abbreviated SZM.GLNU.See Fszm.glnu in .
128830 Gray Level Nonuniformity of Zone Counts Normalized The normalized distribution of zone counts over the gray values in a gray level size zone matrix.See Fszm.glnu.norm in .
128831 Zone Size Nonuniformity The distribution of zone counts over the different zone sizes in a gray level size zone matrix. Abbreviated ZSNU.See Fszm.zsnu in .
128832 Zone Size Nonuniformity Normalized The normalized distribution of zone counts over the different zone sizes in a gray level size zone matrix.See Fszm.zsnu.norm in .
128833 Zone Percentage The fraction of the number of realised zones relative to the maximum number of potential zones in a gray level size zone matrix. Abbreviated ZPERC.See Fszm.z.perc in .
128834 Gray Level Variance in Zones The variance ithe variance in zone counts for the gray levels in a gray level size zone matrix.See Fszm.gl.var in .
128835 Zone Size Variance The variance in zone counts for the different zone sizes in a gray level size zone matrix.See Fszm.zs.var in .
128836 Zone Size Entropy The entropy of zone sizes in a gray level size zone matrix.See Fszm.zs.entr in .
129001 Eligibility Reader Person who looks at and interprets medical images against defined criteria for the purpose of establishing eligibility of the subject of said images to be enrolled in a research experiment or a clinical trial.
129002 Designator Person who designates locations on medical images (such as the location of lesions) for other persons or devices to measure or interpret.
129003 Image Quality Controller Person who reviews medical images to evaluate the compliance of said images with quality criteria.
129004 Results Quality Controller Person who reviews results derived from medical images to evaluate the compliance of said results with quality criteria.
129010 Edited Model A reference to a predecessor model that has been edited to produce the current model.For example: inclusion of more organs, completion of a partial segmentation, insertion of a bisection plane to allow interior inspection, or addition of support material.
129011 Component Model A reference to a predecessor model that contributed to the creation of the current combined model.This includes simple assembly of discrete pieces as well as more complex combination. For example: by Boolean mathematical and similar operations.
129012 Educational Intent Intended for educational purposes.For example: patient or care-giver education/informed consent, or training residents and fellows.
129013 Planning Intent Intended to be used to assist with procedure planning
129014 Tool Fabrication Intended to be used to manufacture a patient-matched tool that is employed during a medical procedure.For example: drill/cutting guides, immobilizers, radiation shields, and plate bending templates.
129015 Prosthetic Fabrication Intended to be used to manufacture a fully external prosthetic/orthotic
129016 Implant Fabrication Intended to be used to manufacture a wholly or partially internal implant
129017 Simulation Intent Intended to be used for simulation and/or practice of a surgery or other medical procedure. "Simulation" is not used for patient-matched simulation, as this would be covered by "Diagnostic Intent" or "Planning Intent".
129018 US 3D CAM model A 3D manufacturing model derived from ultrasound imaging.
129019 Mixed Modality 3D CAM model A 3D manufacturing model derived from images from multiple different modalities.
129020 Photogrammetric Imaging 3D CAM model A 3D manufacturing model derived from measurements made from photographs.
129021 Laser Scanning 3D CAM model A 3D manufacturing model derived from laser scanning measurements.
129100 Fat fraction The fraction of fat present, derived using Dixon or other techniques.
129101 Water/fat in phase Water/Fat In Phase signal, derived using Dixon or other techniques.
129102 Water/fat out of phase Water/Fat Out of phase signal, derived using Dixon or other techniques.
129103 Water fraction The fraction of water present, derived using Dixon or other techniques.
129104 Perfusion image analysis Analysis of perfusion images.
129105 Diffusion image analysis Analysis of diffusion images.
129106 Diffusion tractography Estimation of the course of fiber tracts by analysis of anisotropic diffusion.
129201 Image used for Treatment Planning Images that have been used in the treatment planning process.
129202 Image used for Dose Calculation Images that have been used for dose calculation in the treatment planning process.
129203 Image Acquired during Treatment Images that have been acquired during a treatment session.
129204 Image used as Reference Image for Treatment Images that are used in a treatment session as reference images to position the patient.
129210 Registration used in Planning Registrations that have been used in the treatment planning process
129211 Registration created during Treatment Registrations that have been created in the execution of a treatment session
129301 Coil Marker A coil-shaped marker visible in an image.
129303 Cylinder Marker A cylinder-shaped marker visible in an image.
129305 Wire Marker A thread or rod-shaped marker visible in an image.
129306 Transponder Marker A marker that receives a radio signal and transmits a response.
129308 MR Marker A marker containing a substance that produces a distinctive signal on MR images.
129309 Infrared Reflector Marker Infrared reflecting external marker, e.g., attached to skin or stereotactic frame.
129310 Visible Reflector Marker Visible light reflecting external marker, e.g., attached to skin or stereotactic frame.
129320 Effective Atomic Number The average atomic number for a compound or mixture of materials. There are a variety of methods for estimating this value for a given compound.
129321 Modified Hounsfield Unit Modified pixel values within the Hounsfield Unit Value range.
129322 Value-based Image Each real-world value mapped pixel represents a certain value for a specified material (the exact interpretation of the value range has to be defined by the user).
129323 Material Specific Image Each real-world value mapped pixel value represents a property the attenuation of a material such as attenuation, concentration or density.
129324 Material Removed Image Image with the attenuation contribution of one or more materials removed. For pixels that did not contain any of the removed material(s), the pixel values are unchanged.
129325 Material Highlighted Image Image where pixel values have been modified to highlight a certain target material by partially suppressing the background and/or by enhancing the modified material.
129326 Material Suppressed Image Image where pixel values have been modified to partially suppress the modified material (opposite to Material Highlighted image).
129327 Material Recalculated Image Image where pixels are recalculated by a vendor-specific method.
129328 Volume Occupancy Image Each real-world value mapped pixel represents a fraction, by volume, occupied by the material.
129329 Mass Occupancy Image Each real-world value mapped pixel represents a fraction, by mass, occupied by the material.
130001 Minimum Surface Radiation Dose An objective to achieve a radiation dose which is greater than or equal to the specified radiation dose at the surface of a volume.
130002 Maximum Surface Radiation Dose An objective to achieve a radiation dose which is less than or equal to the specified radiation dose at the surface of a volume.
130003 Minimum Radiation Dose An objective to achieve a radiation dose which is greater than or equal to the specified radiation dose throughout a volume.
130004 Maximum Radiation Dose An objective to achieve a radiation dose which is less than or equal to the specified radiation dose throughout a volume.
130005 Minimum Mean Radiation Dose An objective to achieve a mean radiation dose over the volume which is greater than or equal to the specified radiation dose.
130006 Maximum Mean Radiation Dose An objective to achieve a mean radiation dose over the volume which is less than or equal to the specified radiation dose.
130007 Minimum Equivalent Uniform Dose An objective to achieve an equivalent uniform dose (EUD) which is greater than or equal to the specified radiation dose.
130008 Maximum Equivalent Uniform Dose An objective to achieve an equivalent uniform dose (EUD) which is less than or equal to the specified radiation dose.
130009 Prescription Radiation Dose An objective to achieve a radiation dose which is equal to the specified radiation dose throughout the volume.
130010 Minimum Conformity Index An objective to achieve a conformity index which is greater than or equal to the specified conformity index for a radiation dose which is equal to the specified radiation dose throughout the volume.Minimum Conformity Index as defined in , page 335.
130011 Minimum Healthy Tissue Conformity Index An objective to achieve a healthy tissue conformity index which is greater than or equal to the specified healthy tissue conformity index for a radiation dose which is equal to the specified radiation dose throughout the volume.Minimum Healthy Tissue Conformity Index as defined in , page 335.
130012 Minimum Conformation Number An objective to achieve a conformation number which is greater than or equal to the specified conformation number greater for a radiation dose which is equal to the specified radiation dose throughout the volume.Minimum Conformation Number as defined in , page 335.
130013 Maximum Homogeneity Index An objective to achieve a homogeneity index which is less than or equal to the specified homogenity index for a radiation dose which is equal to the specified radiation dose throughout the volume.Maximum Homogeneity Index as defined in , page 335.
130014 Minimum Percent Volume at Radiation Dose An objective to achieve a radiation dose which is greater than or equal to the specified radiation dose for at least a specified volume percentage.
130015 Maximum Percent Volume at Radiation Dose An objective to achieve a radiation dose which is less than or equal to the specified radiation dose for at least a specified "volume percentage.
130016 Minimum Absolute Volume at Radiation Dose An objective to achieve a radiation dose which is greater than or equal to the specified radiation dose for at least a specified volume size.
130017 Maximum Absolute Volume at Radiation Dose An objective to achieve a radiation dose which is less than or equal to the specified radiation dose for at least a specified volume size.
130018 Minimize Meterset An objective to minimize the total Meterset.
130019 Specified Radiation Dose The radiation dose value for a Dosimetric Objective.
130020 Specified Volume Size The specified volume size of an anatomical region in a Dosimetric Objective.
130021 Specified Volume Percentage The percentage which represents a fractional parameter used by a Dosimetric Objective.
130022 Radiation Characteristics Note Free text note describing characteristics of the radiation.
130023 Beam Shaping Note Free text note describing the devices and techniques used to shape the radiation beam.
130024 Treatment Planning Note Free text note to describe suggestions or advice to treatment planning.
130025 Special Procedure Note Free text note describing additional activities that address individual patient needs.
130026 Patient Positioning Note Free text note describing the process to position the patient for the procedure.
130027 4D Radiation Treatment Note Free text note describing management of patient motion during the radiation treatment.
130028 Patient Setup Note Free text note describing the setup of the patient on the patient support device(s).
130029 Previous Treatment Note Free text note describing previously delivered treatments.
130030 Planning Imaging Note Free text note describing the intended use of images for planning.
130031 Delivery Verification Note Free text note describing how delivery is to be verified.
130032 Simulation Note Free text note describing preferred simulation procedures.
130033 Radiation Therapy Particle Particle used for Radiotherapy treatment.
130034 RT Beam Energy Energy of the Radiotherapy treatment beam.
130035 Patient Positioning Procedure Note Free text note describing the procedure "for acquiring and applying information about patient position.
130036 QA Process Note Free text note describing the Quality Assurance Process for the treatment of the patient.
130037 Ion Therapy Particle Particle for a radiotherapeutic treatment using beams of energetic protons, positive ions or other particles.
130038 Brachytherapy Isotope Isotope for a radiotherapeutic treatment where a decaying radiation source is placed inside or next to a target area, called Brachytherapy.
130039 Adaptive Radiation Therapy Note Free text note describing how adaptive radiotherapy is to be performed.
130040 Teletherapy Isotope Isotope for a radiotherapeutic treatment where a decaying radiation source is placed outside the body.
130041 RT Target Volume containing tissues to be irradiated to a specified radiation dose, typically encompassing a tumor, and possibly including surrounding subclinical disease, and margin(s) to account for uncertainties in patient positioning and organ motion.
130042 RT Dose Calculation Structure Non-target structure or volume used when calculating the radiation dose, e.g., during an optimzation process. This may be a structure whose proximity to the target and/or radiosensitivity restrict the radiation dose deliverable to the target.
130043 RT Geometric Information Points or volumes used as spatial references, e.g., treatment or imaging device isocenter or fiducial markers.
130044 Fixation or Positioning Device Device used to reproducibly position or limit the motion of a patient or portion of a patient during treatment.
130045 Brachytherapy Device Device used to deliver Brachtherapy treatments. This includes both devices containing radioactive sources (seeds, eye plaques) and devices used to position radioactive sources (source applicators, channels etc.).
130046 Non-specific Volume A volume that does not represent a named physical entity.
130047 External Body Structure A volume representing the external shape of the patient body used in radiotherapeutic procedures.
130048 Unclassified Volume A volume that does not correspond to an identifiable physical entity and has user specified boundaries.
130049 CTV Nodal Clinical Target Volume encompassing diseased lymph node(s) , with margin to include surrounding sub-clinical disease as defined in .
130050 CTV Primary Clinical Target Volume encompassing primary tumor(s) , with margin to include surrounding sub-clinical disease as defined in .
130051 GTV Nodal Gross Tumor Volume encompassing diseased lymph nodes as defined in .
130052 GTV Primary Gross Tumor Volume encompassing primary tumor(s) as defined in .
130053 PTV Nodal Planning Target Volume encompassing a nodal CTV, with margin to account for uncertainty in patient positioning and organ motion as defined in .
130054 PTV Primary Planning Target Volume encompassing a primary CTV, with margin to account for uncertainty in patient positioning and organ motion as defined in .
130055 Entire Body Target Volume Entire Body as a target volume for radiotherapy treatment. The usual term for a treatment technique irradiating this target is Full Body Irradiation.
130056 ITV Internal Target Volume encompassing the CTV, with margin to account for internal motion, often delineated using multiple images, e.g., acquired over a breathing cycle, cardiac cycle, etc, as defined in .
130057 Planning Organ At Risk Volume Volume encompassing the Organ At Risk (Planning organ at Risk Volume (PRV)) with margin to account for uncertainty in patient positioning and organ motion as defined in .
130058 Avoidance Volume Volume to which delivered radiation dose should be minimized or limited as defined in .
130059 Treated Volume Volume enclosed by an isodose surface appropriate to achieve the purpose of treatment (e.g., tumor eradication or palliation) as defined in .
130060 Organ At Risk Normal tissue that receives undesired radiation and may be damaged by the radiation treatment as defined in . The treatment is typically planned to limit the radiation dose to such an organ.
130061 Radiation Dose Shaping Volume A volume used to express dosimetric constraints for shaping the radiation dose distribution.
130062 Conformality Shell A volume surrounding the target to achive a high radiation dose gradient using a low radiation dose constraint.
130063 Radiation Dose Normalization Point A point for which a specific radiation dose value is chosen. The rest of the radiation dose distribution is normalized against" this value.
130064 Radiation Dose Reference Point A point at which the radiation dose is observed.
130065 Dose Calculation Bounding Volume Volume for which radiation dose is calculated.
130066 Radiation Interaction Volume Volume in which the interaction of radiation with matter is taken into account.
130067 Patient Anatomy Model The external boundary of patient tissue without additional devices.
130068 Extended Patient Anatomy Model The external boundary of patient tissue plus devices that may be attached or adjacent to the body (such as Bolus, Patient Support Devices, Patient Immobilization Devices).
130069 Patient Setup Point Point at which the patient is initially positioned prior to any other positioning procedure.
130070 Room Laser Patient Setup Point A reference point used for patient setup based on room lasers.
130071 Moveable Laser Patient Setup Point A reference point used for patient setup based on movable lasers.
130072 Reference Acquisition Point A reference point at which patient position verification references are acquired.
130073 Isocentric Treatment Location Point A point representing the machine isocenter.
130074 Specified Conformity Index The Conformity Index for a Dosimetric Objective as defined in , page 335.
130075 Specified Healthy Tissue Conformity Index The Healthy Tissue Conformity Index for a Dosimetric Objective as defined in , page 335.
130076 Specified Conformation Number The Conformation Number for a Dosimetric Objective as defined in , page 335.
130077 Specified Homogeneity Index The Homogeneity Index for a Dosimetric Objective as defined in , page 335.
130078 Brachytherapy Source Applicator Source applicator used in brachytherapy treatment delivery
130079 Brachytherapy Channel Shield Channel shield device used in brachytherapy treatment delivery
130080 Brachytherapy Channel Channel device used in brachytherapy treatment delivery
130081 Unclassified Combination A logical combination of two or more volumes for which the combination is not classified.
130082 Relative Mass Density Ratio of the mass density of a material relative to the mass density of water.
130083 Relative Electron Density Ratio of the electron density of a material relative to the electron density of water.
130084 Effective Z The average atomic number of a material.
130085 Effective Z per A Ratio of effective atomic number to mass (AMU -1) for a material.
130086 Relative Linear Stopping Power Ratio of the linear stopping power of a material to the linear stopping power of water.
130087 Reference Energy An energy value which qualifies a quantity or parameter whose value is defined in respect to this energy.
130088 Linear Cell Kill Factor Linear Cell Kill Factor (α) as defined in J. Deacon et al (Rad. Onc 2(4) : 317-323, 1984), page 318-
130089 Quadratic Cell Kill Factor Quadratic Cell Kill Factor (β) as defined in J. Deacon et al (Rad. Onc 2(4) : 317-323, 1984), page 318.
130090 High Dose Fraction Linear Cell Kill Factor High Dose Fraction Linear Cell Kill Factor (γ) as defined in Frederick W. McKenna et (J. Med. Phys, 36(2) : 100-106, 2011), page 102.
130091 Half-time for Tissue Repair Half-time for Tissue Repair as defined in R Singh R, et al. (Medical Dosimetry 28(4) : 225-259, 2003), page 256.
130092 High Dose Fraction Transition Dose High Dose Fraction Transition Dose as defined in Astrahan, M. (Med. Phys., 35(9) : 4161-4172, 2008), page 4164.
130093 Atomic Number The atomic number of an element, i.e. the number of protons found in the nucleus of an atom.
130094 Elemental Composition Atomic Mass Fraction The fractional weight of the element in a compound.
130095 alpha gEUD Value Tissue-specific parameter that describes the volume effect of radiation dose delivered to a volume.See AAPM Report 166 (http://www.aapm.org/pubs/reports/RPT_166.pdf) for additional information.
130096 Single Fraction A treatment consisting of a single treatment fraction, e.g., for stereotactic treatments.
130097 Standard Fractionation A treatment consisting of a one treatment fraction per day, typically 1.8-2.0 Gy per treatment fraction.
130098 Hypo-fractionation A treatment consisting of a reduced number of treatment fractions relative to a standard fractionation, typically with a higher radiation dose per fraction.
130099 Hyper-fractionation A treatment consisting of an increased number of fractions relative to a standard fractionation, typically two per day with smaller radiation dose per fraction.
130100 Continuous Temporary A treatment consisting of a continuous delivery using a temporary implant.
130101 Continuous Permanent A treatment consisting of a continuous delivery using a permanent implant.
130102 Static Beam A treatment technique in which the field shape and the source position do not change during delivery.
130103 Arc Beam A treatment technique in which the field shape does not change during delivery while the source position follows an arc.
130104 Conformal Arc Beam A treatment technique in which the field shape changes during delivery while the source position follows an arc.
130105 Step and Shoot Beam A treatment technique in which the field shape does not change during an exposure. Several field shapes may be used in different exposures at the same source position.
130106 Sliding Window Beam A treatment technique in which the field shape continously changes during an exposure at the same source position.
130107 VMAT A treatment technique in which the field shape, gantry speed and radiation dose rate changes during delivery while the source position follows an arc.Volumetric Modulated Arc Therapy (VMAT).
130108 Helical Beam A treatment technique in which the field shape continously changes during delivery while the source position follows a continous arc in parallel to a simultaneous patient support movement.
130109 Topographic Beam A treatment technique in which the field shape and the source position do not change during" delivery while the patient support is moving.
130110 Headframe A device attached to the tabletop that is also screwed into the skull of the patient's head to position and orient the head in a prescribed geometry relative to the tabletop. The device is commonly known as a "halo".
130111 Head Mask A device that is placed over the patient's face and attached to the tabletop to prevent the patient from moving relative to the tabletop.
130112 Head and Neck Mask A device that is placed over the patient's face and neck and attached to the tabletop to prevent the patient from moving relative to the tabletop.
130113 Mold A device that is modified by pressure (molded) to fit another object (such as the patient"s anatomy) and then used to control the reproducibility of the patient"s treatment position.
130114 Cast A device that is fabricated from a mold of another object (like the patient"s anatomy) and then used to control the reproducibility of the patient"s treatment position.
130116 Breast Board A device placed on the tabletop to support the chest and arms of a patient in a prescribed position and orientation.
130117 Body Frame A device placed beneath a patient to support the whole body in a prescribed position and orientation relative to the table top.
130118 Vacuum Mold A device placed beneath a patient to support a body part in a prescribed position and orientation relative to the table top. It is commonly a bag containing low density polystyrene spheres that becomes semi-hard when vacuum is applied conforming to the bottom surface of the patient.
130119 Whole Body Pod A device placed beneath a patient to support the whole body in a prescribed position and orientation relative to the table top. It is commonly shaped like a hollow half cylinder. The space between the patient and the wall is commonly filled with a dual component foam that hardens conforming to the bottom surface of the patient.
130120 Rectal Balloon A flexible fluid container inserted into the rectum to maintain an immovable geometry during treatment.
130121 Vaginal Cylinder An intracavity cylinder inserted into the vagina to achieve greater radiation dose control and radiation dose shaping. Radioactive sources are inserted into the cylinder for treatment.
130123 Aperture Block A device, typically made of a low temperature alloy, such as Lipowitz"s metal, that provides an opening in a beam block with constant attenuation across an area of the beam to prevent or reduce radiation dose delivery to normal tissues.
130124 Accessory Tray A device placed into a machine slot or an applicator to which accessories are attached.
130125 Radiotherapy Applicator A device placed into a radiotherapy machine slot which provide slot to add other devices and/or to limit the beam.
130126 Radiation transport-based methods A category of methods for the calculation of effective dose that are based on radiation transport and are used to predict the Relative Biological Effectiveness of an ion beam based on the quality of the radiation used.[Wambersie A, RBE, reference RBE and clinical RBE: Applications of these concepts in hadron therapy, Strahlentherapie und Onkologie 1999 June, 175(2) : 39-43][Paganetti H, et al., Relative biological effectiveness (RBE) values for proton beam therapy, Int J Rad. Onc Biol Phys, 2002 June; 53(2) : 407-421]
130127 Fractionation-based or temporally-based methods A category of methods for the calculation of effective dose that are based on Fractionation or temporal patterns and are used to predict the Biologically Effective Dose.[Thames HD, Hendry JH. Fractionation in radiotherapy. New York: Taylor & Francis; 1987][Barendsen, G.W (1982) Dose fractionation, dose rate and iso-effect relationships for normal tissue responses, Int. J. Radiat. Oncol. Biol. Phys. 8 (11) : 1981-1997.]
130128 Local Effect Model The Local Effect Model (LEM) method used to predict the Relative Biological Effectiveness of dose delivered using ion beams.[Grun, R. Friedrich, T. Elasasser, T. Kramer, M. Zink, K. Karger, C. P. Durante, M. Engenhard-Cabillic, R. Scholz, M. (2012) "Impact of enhancements in the local effect model (LEM) on the predicted RBE-weighted target dose distribution in carbon ion therapy" Physics in Medicine and Biology 57: 7261 - 7274.]
130129 Microdosimetric Kinetic Model The Microdosimetric Kinetic Model (MKM) " used to predict the Relative Biological Effectiveness of dose delivered using ion beams.[Inaniwa, T. Furukawa, T. Kase, Y. Matsufuji, N. Toshito, T. Matsumoto, Y. Furusawa, Y. Node, K. (2010) "Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model" Physics in Medicine and Biology 55: 6721 - 6737.]
130130 Equivalent 2-Gray Fractions Model The linear quadratic model usedto compute the equivalent Biologically Effective Dose (BED) delivered in 2 Gray dose fractions.[Fowler JF. The linear-quadratic formula and progress in fractionated radiotherapy. Br J Radiol. 1989 Aug; 62 (740) : 679-94.]
130131 Linear-Quadratic Model The linear quadratic model usedto compute the equivalent Biologically Effective Dose (BED) delivered at an infinitely low dose-rate.[Fowler JF, Br J Radiol. 1989; 62: 679-694]
130132 Linear-Quadratic Model with Time Factor The modified linear quadratic model with time factor method usedto compute the equivalent Biologically Effective Dose (BED) delivered at an infinitely low dose-rate, taking into account tumor repopulation during treatment.[Fowler JF, Semin. Radiat. Oncol. 1992; 2(1) : 16-21]
130133 Linear-Quadratic-Linear Model The linear-quadratic-linear dose-response model usedto compute the equivalent Biologically Effective Dose (BED) delivered at an infinitely low dose-rate, taking into account linear cell survival with high dose fractions.[Astrahan M, Med.Phys. 2008; 35: 4161-4172]
130134 Linear-Quadratic Model for Low-Dose Rate Brachytherapy The linear-quadratic dose-response model modified for low-dose rate brachytherapy used to compute the equivalent Biologically Effective Dose (BED) delivered at an infinitely low dose-rate.[Sing R, Al-Hallaq H, Med.Dosim. 2003; 28(4) : 225-259]
130135 Historical RT Prescription A Radiotherapy prescription prescribed prior to the current prescription.
130136 RT Prescription Input Images Image Instances available as input for prescribing a Radiotherapy treatment prescription.
130137 RT Treatment Planning Input Images Image Instances available as input for planning a Radiotherapy treatment plan.
130138 Multiple Fixed Sources A treatment technique using multiple decaying radiation sources at fixed spatial locations.
130139 Synchronized Robotic Treatment A treatment technique using a robotic delivery device with real-time motion tracking and compensation.
130140 Non-Synchronized Robotic Treatment A treatment technique using a robotic delivery device without real-time motion tracking and compensation.
130141 ^3^Helium nucleus Ionized helium atom with 2 protons and 1 neutron.
130142 ^4^Helium nucleus Ionized helium atom with 2 protons and 2 neutrons.
130143 ^12^Carbon nucleus Ionized carbon atom with 6 protons and 6 neutrons.
130144 ^16^Oxygen nucleus Ionized oxygen atom with 8 protons and 8 neutrons.
130150 Pressure above warning limit The injector device detected a pressure above the warning threshold, generated a warning and did not automatically terminate the administration.
130151 Pressure above adjustment limit The injector device detected a pressure above the adjustment limit, took compensating action and did not automatically terminate the administration.
130152 Flow rate above warning limit The injector device detected a flow rate above the warning threshold, generated a warning and did not automatically terminate the administration.
130153 Flow rate above adjustment limit The injector device detected a flow rate above the adjustment limit, took compensating action and did not automatically terminate the administration.
130154 Terminated due to request from operator The injector device terminated the administration due to detection of an abort request by the operator.
130155 Fixed duration pause ended The device detected that a pause duration has been reached and the device resumed automatically.
130156 Terminated due to pressure above termination limit The injector device detected a pressure above the termination limit and automatically terminated the administration.
130157 Terminated due to flow rate above termination limit The injector device detected a flow rate above the termination limit and automatically terminated the administration.
130158 Terminated due to excessive duration pause The Injector device detected that a pause duration has exceeded limit and the injector device terminated the administration.
130159 Terminated due to injector communication loss The injector device detected a communication loss and automaticallyterminated the administration.
130160 Terminated due to unspecified injector failure The injector device detected an unspecified failure and automaticallyterminated the administration.
130161 Keep vein open started The injector device started saline flow for the purpose of keeping vein open.
130162 Keep vein open ended The injector device ended saline flow for the purpose of keeping vein open.
130163 Syringe attached The injector device detected that a syringe was attached to the injector.
130164 Syringe detached The injector device detected that a syringe was detached from the injector.
130165 Total Keep Vein Open Volume Administered Total volume of flush delivered by the keep vein open function of the injector.
130168 Automatic Programmed Administration Phase An administration phase where fluid is being delivered by an injector system according to the programmed instructions.
130169 Automatic Programmed Delay Phase An administration phase where fluid delivery is stopped by the injector system until a programmed time elapses.
130170 Automatic with Manual Hold Phase An administration phase where the fluid is delivered automatically by an injector system and stopped under manual control by the operator.
130171 Automated Manual Inject Phase An administration phase where the fluid is delivered by the injector system under manual control by the operator.
130172 Manually Triggered Injection Information Information only available if injection was triggered manually.
130173 Automated Administration An administration mode where the fluid is delivered by a mechanical injector system.
130174 Manual Administration An administration mode where the substance is delivered manually
130175 Air detected The injector device detected air in the tubing or syringe before or during the Imaging Agent administration and did not automatically terminate the administration.
130176 Terminated due to air detected The injector device detected air in the tubing or syringe and terminated the administration.
130177 Terminated by scanner The injector device received instruction from scanner to terminate the administration and terminated the administration.
130178 Terminated due to critical battery level The injector device detected critical battery level and terminated the administration.
130179 Terminated due to consumable removal The injector device detected removal of a consumable from the injector device and terminated the administration.
130181 Administration Mode A code that specifies how the Imaging Agent is administered to the patient.
130182 Planned Imaging Agent Administration Procedure Report A report of the planned patient-specific Imaging Agent administration steps.
130183 Imaging Agent Information Description of a specific Imaging Agent that was planned or was administered.
130184 Osmolality at 37C Number of osmoles of solute per kilogram of solvent at 37°C.
130185 Osmolarity at 37C Number of osmoles of solute per liter (L) at 37°C.
130186 Viscosity at 37C A measure of a resistance of a fluid to gradual deformation by stress, measured at 37°C.
130187 Imaging Agent Warmed Indicates if an Imaging Agent was warmed prior to the administration procedure.
130188 Contrast Transverse Relaxivity The degree to which a paramagnetic contrast agent can enhance the proton transverse relaxation rate constant (R2, 1/T2), normalized to the concentration of the contrast agent.Also referred to as r2. Typically expressed in units l/mmol/s.
130189 Is Ionic Indicates whether the Imaging Agent is Ionic or non-ionic.
130190 Dosing Factor Indicates normalized dose of Imaging Agent per kg of patient weight. Typically recommended by the vendor.For e.g,. grams Iodine per Kg (gI / Kg).
130191 Imaging Agent Component Usage Information about use of Imaging Agent component(s).
130192 Imaging Agent Administration Steps Information about list of administration steps for administering Imaging Agent.
130193 Pressure Limit A limit set at the power injector device indicating the maximum allowed pressure planned for administering the Imaging Agent.
130194 Time after the start of injection Time after the start of injection of a delivered Imaging Agent administration.
130195 Imaging Agent Administration Step An individual administration step in the Imaging Agent administration plan.
130196 Imaging Agent Administration Step Identifier Identifies a step in an Imaging Agent administration plan.
130197 Imaging Agent Administration Delay Time difference between the nominal start of the administration step and the actual start of Imaging Agent administration.
130198 Scan Delay Time delay for start of image acquisition after start of Imaging Agent administration.
130199 Imaging Agent Administration Steps Description Description of Imaging Agent administration plan.
130200 Imaging Agent Administration Protocol Name Protocol name for Imaging Agent administration.
130202 Imaging Agent Administration Phase Information about a delivery phase of an Imaging Agent administration step.
130203 Imaging Agent Administration Phase Identifier Identifies a phase in an Imaging Agent administration step.
130204 Imaging Agent Administration Phase Type Type of phase in an Imaging Agent administration step.
130205 Initial Volume of Imaging Agent in Container The volume of the Imaging Agent in an Imaging Agent container before administration.
130206 Residual Volume of Imaging Agent in Container The volume of the Imaging Agent remaining in the Imaging Agent container after administration.
130207 Rise Time Time for the injector to build up from zero to the set pressure.
130208 Starting Flow Rate of administration Flow rate at the start of an administration of the Imaging Agent.
130209 Ending Flow Rate of administration Flow rate at the end of an administration of the Imaging Agent.
130210 Bolus Shaping Curve A vendor-specific code indicating the shape of the flow rate curve within an administration phase.
130211 Imaging Agent Administration Completion Status The status of the Imaging Agent administration procedure at completion as reported by the automated injector or by the administering person.
130212 Imaging Agent Administration Adverse Events Information about adverse events occurring during administration of an Imaging Agent.
130214 Estimated Extravasation Volume The estimated volume lost at the injection site.The estimation includes extravasation, paravenous administration and leakage at the injection site.
130215 Adverse Event Detection DateTime Date and Time when an adverse event was noticed by the observer.
130216 Referenced Imaging Agent Administration Step UID The unique identifier of the Imaging Agent administration step being referenced.
130217 Referenced Imaging Agent Administration Phase Identifier The identifier of an Imaging Agent administration phase being referenced.
130218 Programmable Injector Device An injector device that can be configured to execute a series of phases automatically.
130219 Number of Injector Heads Number of injector heads or pumps (single, dual or many) in an injector device.
130220 Administration discontinued Whether the agent administration was discontinued.
130221 Imaging Agent Volume per Unit of Presentation The volume of Imaging Agent in one unit of presentation. The capacity of the unit of presentation may be larger than this.
130222 Imaging Agent Administration Consumable Information about the Imaging Agent accessory or consumable used for performing the Imaging Agent administration.
130223 Imaging Agent Administration Consumable Type Type of consumable used for performing the Imaging Agent administration.
130224 Consumable is New If the consumable is installed newly during the preparation process for this Imaging Agent Administration.
130226 Planned Imaging Agent Administration Information about the Imaging Agent administration steps that is patient-specific.
130227 Performed Imaging Agent Administration Information about the Imaging Agent administration steps that were delivered to a patient.
130228 Contrast Volume Limit The maximum volume of contrast agent allowed to be administered.This is typically specified by the prescribing health care professional for patient safety and quality purposes.
130229 Flow Rate vs Time Graph depicting the measurement of flow rate of fluid against time.
130230 Pressure vs Time Graph depicting the measurement of pressure of fluid against time.
130231 Barcode Value The alphanumeric string from reading a barcode.
130232 Imaging Agent Administration Graph Information about two-dimensional graph data for a syringe or pump.
130233 Imaging Agent Administration Injector Events Information about events that occurred at an injector during an Imaging Agent administration.
130234 Imaging Agent Administration Injector Event Type Type of event that occurred at an injector during an Imaging Agent administration.
130235 Injector Event Detection DateTime Date and time when an injector event was detected.
130236 Planned Imaging Agent Administration SOP Instance Reference to a Planned Imaging Agent Administration SOP instance.
130237 Imaging Agent Administration Activity Information about the activity in an Imaging Agent administration phase. In an Automated Injection system this describes the activity of one of the pump or syringe units used.
130238 Imaging Agent Component Information about a component of an Imaging Agent.
130239 Component Volume Volume of one agent component in a mixture of multiple components.
130240 Total Phase Volume Administered Total volume administered by all syringes/pump actions during a single phase.
130241 Total Step Volume Administered Total volume administered by all syringes/pump actions within all phases during a single Step.
130242 Total number of manually triggered injections Total number of times that an injection was triggered manually.
130244 Peak Flow Rate in Phase Activity Peak flow rate value detected at a specific location (syringe or pump) during a specific activity of an administration phase.
130245 Peak Pressure in Phase Activity Peak pressure value detected at a location (syringe or pump) during a single administration phase activity.
130246 Imaging Agent Administration Performed Step UID Unique identification of a single performed Imaging Agent administration step actually delivered on a specific occasion
130247 Patency Test Injection An injection of an inactive agent to test for blockages or leakages in the delivery path, usually performed prior to an administration of an imaging or therapeutic agent.
130248 Transit Time Test Injection An injection of a bolus of Imaging Agent to determine the appropriate delay time for a diagnostic administration.
130249 Diagnostic Administration Administration of an Imaging Agent for the purpose of enhancing contrast in an image.
130250 Administration Step Type Type of step in an Imaging Agent administration. For example, a test administration or a diagnostic administration.
130251 Flush Administration Injection of an inactive fluid to clear the administration path of an active agent.
130252 Negative exponential A curve that decays exponentially from a specified start value, at a specified decay rate.
130253 Linear Curve A curve that changes linearly from a specified start value to a specified end value.Note: The start value and the end value may be the same, indicating a flat curve.
130254 Imaging Agent Identifier Identifies an Imaging Agent uniquely within a set of Imaging Agents. The Imaging Agent may be a single component or a mix of multiple components.
130255 Referenced Imaging Agent Identifier The identifier of an Imaging Agent being referenced.
130257 Consumable Catheter Type Type of catheter used for Imaging Agent administration.
130259 Contrast Reaction Prophylactic Agent A pharmaceutical agent administered as a pre-medication to prevent contrast reactions.
130261 Imaging Agent Administration Performed Phase UID Unique identification of a single Imaging Agent administration performed phase.
130262 Referenced Imaging Agent Administration Phase UID The unique identifier of the Imaging Agent administration performed phase being referenced
130263 Automatic Programmed Wait Phase A non time-determined administration phase that is not automatically terminated, where fluid delivery is stopped until manually resumed.
130264 Imaging Agent Administration Injector Phase Identifier The Imaging Agent Administration Injector Phase Identifier used for presenting this Phase to the User Interface of the injector. Not necessarily the same as the Imaging Agent Administration Phase Identifier of the IAASR Plan.
130265 Imaging Agent Administration Phase with Manual Hold Indicator for marking this phase as a Automated Administration Phase, which has undergone a manual hold during execution.
130266 Programmed hold started A programmed administration phase initiated an injector hold/wait state.
130267 Manual hold started A manual intervention of the technologist initiated an injector hold/wait state.
130268 Manual resume from hold A manual intervention of the technologist has resumed injector fluid administration. It does not matter if the hold/wait state was initiated programmed or manually.
130269 Terminated hold due to timeout The injector terminated injection processing from hold/wait after exceeding a time limit.
130290 Median Towards the mid-sagittal plane of the body.
130300 Skin of paraspinal area of the neck Structure of skin of paraspinal area of the neck.
130301 Skin of paraspinal area of the superior back Structure of skin of paraspinal area of the superior back.
130302 Skin of upper paraspinal region Structure of skin of upper paraspinal region.
130303 Skin of mid paraspinal region Structure of skin of mid paraspinal region.
130304 Skin of lower paraspinal region Structure of skin of lower paraspinal region.
130305 Skin of anterior helix of ear Structure of skin of anterior helix of ear.
130306 Skin of caruncle of eye Structure of skin of caruncle of eye.
130307 Skin of inferior helix of ear Structure of skin of inferior helix of ear.
130308 Skin of inferior posterior surface of the pinna Structure of skin of inferior posterior surface of the pinna.
130309 Skin of lateral part of dorsum of foot Structure of skin of lateral part of dorsum of foot.
130310 Skin of lower antihelix of ear Structure of skin of lower antihelix of ear.
130311 Skin of lower eyelid margin Structure of skin of lower eyelid margin.
130312 Skin of infraalar groove Structure of skin of infraalar groove.
130313 Skin of medial part of dorsum of foot Structure of skin of medial part of dorsum of foot.
130314 Skin of paranasal cheek Structure of skin of paranasal cheek.
130315 Skin of posterior helix of ear Structure of skin of posterior helix of ear.
130316 Skin of posterior lobule of the ear Structure of skin of posterior lobule of the ear.
130317 Skin of sole of forefoot Structure of skin of sole of forefoot.
130318 Skin of superior antihelix of ear Structure of skin of superior antihelix of ear.
130319 Skin of superior posterior helix of ear Structure of skin of superior posterior helix of ear.
130320 Skin of superior posterior surface of the pinna Structure of skin of superior posterior surface of the pinna.
130321 Skin of upper antihelix of ear Structure of skin of upper antihelix of ear.
130322 Skin of upper eyelid margin Structure of skin of upper eyelid margin.
130323 Skin of mid back Structure of skin of mid back.
130324 Functional condition present during acquisition A functional condition present during acquisition, such as phonation, weight bearing, voiding of the bladder or hemodynamic physiological challenges.
130330 Jaw Pair RT beam limiting device jaw pair
130331 Leaf Pairs RT beam limiting device multi-element leaf pairs
130332 Variable Circular Collimator A circular, aperture size adjustable beam limiting device for an RT treatment device.
130333 Single Leaves RT beam limiting device multi-element unpaired leaves
130334 X Orientation Oriented in the X direction of a defined coordinate system.
130335 Y Orientation Oriented in the Y direction of a defined coordinate system.
130340 Physical Compensator Physical RT external beam compensator to compensate for inhomogeneity.
130341 Total Body Irradiation RT Treatment irradiating the body of the Patient in part or in whole.
130342 Total Skin Irradiation RT Treatment irradiating the surface of the skin of the Patient in part or in whole.
126812 Isocentric Patient Support Continuous Pitch Angle Patient SupportContinuous Pitch Angle at the isocenter position about the x-axis of the Equipment Coordinate System.
126813 Isocentric Patient Support Continuous Roll Angle Patient Support Continuous Roll Angle at the isocenter position about the y-axis of the Equipment Coordinate System.
126814 Isocentric Patient Support Continuous Yaw Angle Patient Support Continuous Yaw Angle at the isocenter position about the z-axis of the Equipment Coordinate System.
126815 Isocentric Patient Support Lateral Position Patient Support Lateral Position along the x-axis of the Equipment Coordinate System.
126816 Isocentric Patient Support Longitudinal Position Patient Support Longitudinal Position along the y-axis of the Equipment Coordinate System.
126817 Isocentric Patient Support Vertical Position Patient Support Vertical Position along the z-axis of the Equipment Coordinate System.
130343 Electron Fixed Aperture A type of device (or cone) for electron treatments that attaches to the applicator carriage of an RT treatment device for the purpose of holding an aperture and a bolus close to the patient's skin. Several beam applicators may be available to reduce the weight of apertures lifted by therapists, decrease the aperture/bolus-to-skin distance, and reduce leakage radiation.
130344 Photon Fixed Aperture A type of device (or cone) for photon treatments that is attached to the radiation head of an RT treatment device into which beam modifiers are installed.
130345 Intraoperative Fixed Aperture A type of device which is used to delimit the radiation of an RT treatment device in case of an intraoperative radiotherapeutic treatment.
130346 Hard Wedge A physical device placed inside the radiation head used to modify the fluence distribution across the field.
130347 Motorized Wedge A physical device manually placed between the radiation head and the patient used to modify the fluence distribution across the field. It is motorized and can be inserted/extracted from the beam path.
130348 Dynamic Wedge An effective wedge generated by the movement of a jaw across the treatment field while delivering radiation.
130349 Graticule Mechanical grid to embed scaling information in a radiographic image
130350 Reticle Mechanical crosshair to embed a crosshair representing axes and scaling information in a radiographic image
130351 Image Detector An electronic radiographic imaging device
130352 Film Holder Mechanical device to hold imaging film
130353 Winston-Lutz Pointer A spherical mechanical indicator used for alignment
130354 Bowtie Filter A bowtie-shaped filter used in imaging
130355 Flattening Filter Beam Beam that uses a filter to produce a nearly uniform intensity profile.
130356 Non-Flattening Filter Beam Beam that does not use a filter to produce a nearly uniform intensity profile.
130357 Partial Flattening Filter Beam Beam that uses a filter to produce a nearly uniform region across part of the intensity profile.
128678 Physics Assistant A medical professional capable of developing a radiotherapy plan from a Physicians prescription and assisting in radiation machine calibration and other radiotherapy quality assurance work under supervision of a Medical Physicist.
130358 Nominal Radiation Source Location The point location defined as the nominal source of radiation.
130359 Treatment Machine Isocenter The center point of the treatment machine through which all beam central axes pass under all gantry angles.
130360 Fixed Laser Setup Point A fixed point at which initial patient setup is performed based on lasers.
130361 Radiotherapy Treatment Device A device delivering radiotherapy treatments.
130362 Head Node Set Set of Robotic Nodes that can be used for targets associated with the patient's head.
130363 Body Node Set Set of Robotic Nodes that can be used for targets within the patient's body, excluding the head.
130364 Trigeminal Node Set Set of Robotic Nodes that can be used for targets near the patient's trigeminal nerve.
130365 QA Node Pair Two Robotic Nodes for Quality Assurance, for example daily checks.
130366 QA Node Single Robotic Node for Quality Assurance.
130370 RTV Rendition DICOM objects communicated in time-synchronized flows using DICOM-RTV, intended for a simultaneous presentation.
130371 RTV Audio and Video Rendition Audio and Video DICOM objects communicated in time-synchronized flows using DICOM-RTV, intended for a simultaneous presentation.
130372 RTV Stereo Video Rendition Two Video DICOM objects communicated in time-synchronized flows using DICOM-RTV, intended for a stereo video.
130373 RTV Audio and Stereo Video Rendition Audio and two Video DICOM objects communicated in time-synchronized flows using DICOM-RTV, intended for a stereo video.
130400 Geometric purpose of region The purpose of defining a region.
130401 Visual explanation A visual explanation of how an algorithm produced its results.
130402 Class activation Values are derived using global average pooling in convolutional neural networks to produce a localization map highlighting the important regions in the image for predicting a class. The class activation map (CAM) indicates the discriminative image regions used by the network to identify a class.
130403 Gradient-weighted class activation Values are derived using the gradients of a target class flowing into the final convolutional layer of a convolutional neural network to produce a localization map highlighting the important regions in the image for predicting a class. The gradient-weighted class activation map (Grad-CAM) indicates the discriminative image regions used by the network to identify a class.
130404 Saliency Values are derived using a single back-propagation pass through a network to produce a localization map highlighting the spatial support of a given class in a given image.
130405 Patient-Attached Dose Control Object An object which is attached to the patient to attenuate the therapeutic dose (such as a Bolus or a lead shield).
130406 Non-uterine leiomyosarcoma A leiomyosarcoma (sarcoma containing large spindle cells of smooth muscle) occuring at a site other than the uterus.
130407 Bone and soft tissue Body structures of bone and soft tissue.
130408 Perivascular adipose tissue fat attenuation index A measure of weighted attenuation shifts within perivascular adipose tissue, computed as a weighted measure of attenuation in concentric layers of perivascular tissue around the arterial wall, capturing the respective perivascular attenuation gradients. Abbreviated "FAI".See Antoniades C, Kotanidis CP, Berman DS. State-of-the-art review article. Atherosclerosis affecting fat: What can we learn by imaging perivascular adipose tissue? Journal of Cardiovascular Computed Tomography. 2019 Mar 29;0(0). Available from: http://​www.journalofcardiovascularct.com/​article/​S1934-5925(18)30618-X/​abstract.
130410 Patient position A channel monitoring the patient’s position.
130411 Patient rotation longitudinal A channel monitoring the patient’s rotation around the body’s longitudinal (head – feet) axis.
130412 Patient elevation A channel monitoring the angle of elevation of the patient against horizontal.
130413 Hyperventilation begin Begin of deepened or accelerated breathing.
130414 Hyperventilation end End of deepened or accelerated breathing.
130415 Post-hyperventilation Point in time after end of hyperventilation.
130416 Airflow Thermistor Airflow measured by a thermistor sensor.
130417 Airflow Thermocouple Airflow measured by a thermocouple sensor.
130418 Airflow Nasal Prong Airflow measurement by a nasal prong.
130419 Airflow PVDF Airflow measurement by a nasal piezoelectric polyvinylidenefluoride sensor.
130420 Airflow CPAP Airflow measurement by a Continuous Positive Airway Pressure device.
130421 Airflow Airflow measured by an unspecified method or device.
130422 PAP Pressure Pressure delivered by a positive airway pressure device like a CPAP or BiPAP machine.
130423 PAP Leak Pressure Pressure of air leaking from a positive airway pressure device like a CPAP or BiPAP machine.
130424 PAP Tidal Volume Tidal volume during breathing when subject is using a positive airway pressure device like a CPAP or BiPAP machine.
130425 Esophageal Pressure Pressure in the esophagus measured by esophageal manometry.
130426 Respiratory Pressure Respiratory pressure measured with an unspecified method or device.
130427 Thoracic Respiratory Inductance Respiratory effort delivered by a respiratory inductance plethysmography (RIP) belt applied on the patient’s thorax.
130428 Abdominal Respiratory Inductance Respiratory effort delivered by a respiratory inductance plethysmography (RIP) belt applied on the patient’s abdomen.
130429 Thoracic Respiratory PVDF Respiratory effort delivered by a piezoelectric polyvinylidenefluoride sensor belt applied on the patient’s thorax.
130430 Abdominal Respiratory PVDF Respiratory effort delivered by a piezoelectric polyvinylidenefluoride sensor belt applied on the patient’s abdomen.
130431 Thoracic Respiratory Effort Respiratory effort measured by an unspecified method or device on the patient’s thorax.
130432 Abdominal Respiratory Effort Respiratory effort measured by an unspecified method or device on the patients abdomen.
130433 Respiratory Effort Respiratory effort measured by an unspecified method or device.
130434 CO2 Transcutaneous Partial pressure of carbon dioxide in the respiratory gases measured transcutaneously.
130435 CO2 Waveform End-tidal Main-stream Partial pressure of carbon dioxide measured in the end-tidal main-stream respiratory gases.
130436 CO2 Trend End-tidal Main-stream Partial pressure of carbon dioxide measured in the end-tidal main-stream respiratory gases averaged over time.
130437 CO2 Waveform End-tidal Side-stream Partial pressure of carbon dioxide measured in the end-tidal side-stream respiratory gases.
130438 CO2 Trend End-tidal Side-stream Partial pressure of carbon dioxide measured in the end-tidal side-stream respiratory gases averaged over time.
130439 CO2 Waveform Main-stream Partial pressure of carbon dioxide measured in the main-stream respiratory gases.
130440 CO2 Waveform Side-stream Partial pressure of carbon dioxide measured in the side-stream respiratory gases.
130441 CO2 Trend Main-stream Partial pressure of carbon dioxide measured in the main-stream respiratory gases averaged over time.
130442 CO2 Trend Side-stream Partial pressure of carbon dioxide measured in the side-stream respiratory gases averaged over time.
130443 CO2 Respiration Partial pressure of carbon dioxide in the respiratory gases measured using an unspecified method or device.
130444 RT Treatment with Ad Hoc Planning Radiotherapy treatment delivery where treatment parameters are defined at the treatment device, rather than specified by a treatment plan.
130445 Imaging Agent Administration Step Sequence Number The order in which Imaging Agent administration steps are planned to be performed.
130450 Operator decision to terminate treatment Decision was made by the operator of the equipment to discontinue treatment.
130451 Patient decision to terminate treatment Decision was made by the patient to discontinue treatment.
130452 Physician decision to terminate treatment Decision was made by the physician to discontinue treatment.
130453 Treatment Terminated Treatment delivery of this RT Radiation was terminated.
130454 Resolved by overriding Interlock An out-of-tolerance delivery parameter was accepted or re-specified and treatment delivery was continued.
130455 Resolved by repositioning Patient The patient was re-positioned and treatment delivery was continued.
130456 Bolus Present A bolus is confirmed to be present.
130457 Cone Present A cone is confirmed to be present.
130458 Block Present A block is confirmed to be present.
130459 Applicator Present An applicator is confirmed to be present.
130460 Headframe Present A headframe is confirmed to be present.
130461 Inappropriate Patient Orientation The patient could not be positioned on the patient positioning device in a way, that the shape of treatment area has an unacceptable orientation to match the intended target area.
130462 Inappropriate Patient Position The patient could not be positioned on the patient positioning device in a way, that the that the shape of treatment area radiated the intended target area.
130463 Machine Not Available The machine intended to be used for treatment was not available.
130464 Change in Patient Anatomy The patient´s anatomy is found to be inconsistent with the patient model used during planning to the extent that treatment delivery was impacted.
130465 Machine Calibration Adjustment A re-calibration of the treatment device impacted the treatment delivery.
130466 Unavailability of a Beam Modifier A planned Beam Modifier was not available at the time of treatment.
130467 Machine Capability License Expired A capability of the treatment device was not available because the corresponding license expired.
130468 Beam Targeting Tolerance Violation Beam targeting parameters have been adjusted in a way that violated a clinical tolerance.
130469 Meterset Tolerance Violation A Meterset value has been adjusted in a way that violated a clinical tolerance.
130470 Delivery Rate Tolerance Violation A Delivery Rate has been adjusted in a way that violated a clinical tolerance.
130471 Jaw Position Tolerance Violation Jaw positions exceeded the machine tolerance.
130472 MLC Position Tolerance Violation One or more MLC leave positions exceeded the machine tolerance.
130473 Source Position Tolerance Violation The Source Position angle exceeded the machine tolerance.
130474 Dose Rate Tolerance Violation The dose rate exceeded the machine tolerance.
130475 Primary Fluence Monitoring System Interlock An interlock triggered by failure of the primary system monitoring fluence.
130476 Secondary Fluence Monitoring System Interlock An interlock triggered by failure of the secondary system monitoring fluence.
130477 Timer Interlock An interlock triggered by a timer.
130478 Door Interlock An interlock triggered by a door being open.
130479 Patient Motion Interlock An interlock triggered by patient movement.
130480 Family history of non-melanoma skin cancer Information about non-melanoma skin cancers in blood relatives of the patient.
130481 Family history of melanoma in situ Information about in situ melanoma in blood relatives of the patient.
130482 History of non-melanoma skin cancer Information about non-melanoma skin cancers in the patient.
130483 Number of malignant melanomas The number of malignant melanomas the patient has had diagnosed.
130484 Number of melanomas in situ The number of in situ melanomas the patient has had diagnosed.
130485 Firm skin lesion A skin lesion that is firm on palpation.
130486 Raised skin lesion A lesion that is raised from the skin surface on palpation.
130487 Number of first-degree relatives affected by malignant melanoma The number of direct relatives (i.e., parent, sibling, offspring) who have malignant melanoma.
130488 Region in Space A continuous part of space, not necessarily associated with a particular image.
130489 Referenced Region of Interest Identifier A reference to an identifier of a Region of Interest.For example, the value of ROI Number (3006,0022) within an Item of Structure Set ROI Sequence (3006,0020) in an Instance of RT Structure Set Storage SOP Class.
130490 Centerline A path along the long axis of an elongated finding or feature, which is equidistant from its surface, such as along the center of the lumen of a vessel.
130491 Stimulation Mode Mode of stimulation used when applying stimulation techniques during procedure.
130492 Stimulus Sample Position The sample number where the first stimulation event takes place.
130493 Stimulus Time Offset The time offset where the stimulation starts, relative to the start time of the recorded waveform data.
130494 Number of Stimulus Events How many stimulation events took place.
130495 Frequency of Stimulus Events The frequency with which periodic stimulation occurs.
130500 Accumulated Dose Data Description of dosimetric-related values that can be summarized for the entire scope of accumulation.
130501 Irradiation Event Summary Data Description of dosimetric-related values that can be summarized for a single irradiation event.
130502 Reference Point Dosimetry Description of the reference point definition and accumulated dose values at the reference point.
130503 Is Rejected Acquisition This acquisition of data (e.g., for constructing an image) was for some reason unsatisfactory.
130504 Reason for Rejecting Acquisition The reason that data (e.g., for constructing an image) was rejected.
130505 Irradiation Details Description of the radiation dose characteristics independent of an irradiation event.
130506 RDSR Frame of Reference Origin The component that is used to define the origin of the RDSR RCS.
130507 RDSR Frame of Reference Description The description of the RDSR reference coordinate system. It should include a description of where the origin is, as well as the orientation of the coordinate system.
130508 Radiation Source Characteristics Description of the radiation source characteristics
130509 X-Ray Filter Thickness The thickness of the X-Ray filter
130510 Reported Value Type Describes if a reported value is a mean, median, maximum, minimum, etc.
130511 Radiation Technique Description of radiation technique details
130512 Filtration Description of a filter
130513 Attenuators Description of attenuators
130514 Radiation Output Description of the output measurement point dose accumulation timing and values.
130515 Air Kerma at Output Measurement Point The air kerma (in mGy) accumulated at the output measurement point during a given period of time.
130516 Radiation Field Area Description of the radiation field area and corresponding timing and source index.
130517 Radiation Field Outline A list of three-dimensional coordinates that describe the perimeter of the radiation field. The points shall be coplanar and are limited to describing either polygons or ellipses.
130518 Value Timing Specifies when a value was determined within a period of time.
130519 X-Ray Source Reference Coordinate System Description of the X-Ray source coordinate reference system and the transformation matrix that relates it to the RDSR reference coordinate system
130520 Transformation Matrix A transformation matrix that relates one coordinate system to another
130521 Center of Rotation The point about which an object rotates
130522 Rotation Plane Normal Point A point defining a vector relative to the center of rotation that defines a normal vector of the rotation plane
130523 Rotation Angle The angle about the center of rotation for a rotating object
130524 Beam Position Description of component positions described in the X-Ray source reference coordinate system
130525 Output Measurement Point Position The three-dimensional coordinate of the output measurement position. The output measurement position is described in the X-Ray source reference coordinate system.
130526 Reference Point Position The three-dimensional coordinate of the reference point position. The reference point position is described in the X-Ray source reference coordinate system. The reference point may be at the same position as the output measurement point.
130527 Identification of the Attenuator Textual identification for each attenuator described. The identifier is used to link the description of the attenuator to its position described in the beam position or attenuator position template. The identifier shall not change during the scope of accumulation described in 10040, and shall not be repeated.
130528 Attenuator Position Description of positions and corresponding timing for attenuators
130529 Patient Attenuation Characteristics Description of various patient attenuation characteristics that may be known by the system and may change during the course of the scope of accumulation
130530 Procedure Characteristics Description of various procedure characteristics that may change during a study and may be useful to aid in dosimetry or quality assurance
130531 Attenuator Characteristics Characteristics of an X-Ray attenuator used as either a filter or attenuating object in the X-Ray beam. Includes a description of actual or equivalent material, as well as thickness information.
130532 Duration of Time Period All the points in time throughout a defined period of time
130533 Beginning of Time Period The point in time at the beginning of a defined period of time
130534 End of Time Period The point in time at the end of a defined period of time
130535 Middle of Time Period The point in time at the middle of a defined period of time
130536 Room Origin The origin of the Frame of Reference is defined as part of the room in which the equipment is located
130537 Equipment Origin The origin of the Frame of Reference is defined as part of the equipment
130538 Patient Support Origin The origin of the Frame of Reference is defined as part of the patient support
130539 Isocenter Origin The origin of the Frame of Reference is defined as the isocenter of the imaging system
130540 Patient Coordinate System Origin The origin of the RDSR Frame of Reference is defined as the origin of the patient coordinate system in the images.
130541 10 cm Dosimetry Phantom A dosimetry phantom consisting of a 100 mm diameter polymethyl methacrylate (PMMA) cylinder. The phantom will be at least 140 mm in length. The phantom will be longer than the length of the sensitive volume of the radiation detector used for measurements. The phantom will have five holes just large enough to accept a radiation detector and will be parallel to the axis of symmetry: one hole at the center, and four holes with their centers 10 mm below the surface of the phantom at 90° intervals. For the holes not used during a measurement, properly fitting insert parts made of PMMA will be used.
130542 Magnetic field strength Nominal field strength of MR magnet.
130543 Endorectal coil used Indication of whether endorectal coil was used during MR examination.
130544 Endorectal coil type Type of the endorectal coil used during MR examination.
130545 Inflatable endorectal coil fill substance Substance used to fill endorectal coil in order to suppress distortion artifacts during MR examination.
130546 Cross-sectional scan plane orientation Orientation of the plane defining image acquisition.
130547 Dynamic contrast-enhanced temporal resolution Time between acquisition of imaging samples corresponding to the same tissue location during dynamic contrast-enhanced examination.
130548 Genitourinary History Clinical history of the patient related to the genitourinary health.
130549 Imaging Study Quality Assessment of the imaging study related to its quality, as defined by the compliance with the technical acquisition requirements or as perceived by the reader.
130550 Imaging Series Quality Assessment of a specific imaging series related to its quality, as defined by the compliance with the technical acquisition requirements or as perceived by the reader.
130551 Reporting system Standard or guideline used to perform structured evaluation of imaging study.
130552 Prostate MRI relevant procedure information Information relevant for evaluation of prostate MR imaging study.
130553 Prostate Imaging Findings Findings identified in prostate images
130554 Overall Prostate Finding Finding relating to the overall assessment of the prostate gland
130555 Localized Prostate Finding Finding relating to the localized entities within the prostate gland
130556 Prostate relational measurements Measurements relating localized findings to the prostate gland
130557 Distance from neurovascular bundle Distance between a finding and a neurovascular bundle
130558 Lesion capsular contact length Length of the portion of the lesion abutting the prostate capsule as observed in the image.
130559 Extra-prostatic Finding Finding identified in prostate MRI that is located outside of the prostate gland.
130560 PI-RADS Localized Abnormality Assessment Evaluation of a localized abnormality within the gland using Prostate Imaging Reporting and Data System (PI-RADS®) guidelines.
130561 PI-RADS T2WI Lesion Assessment Assessment of the lesions characteristics based on its appearance in T2-weighted MR images following the Prostate Imaging Reporting and Data System (PI-RADS®) guidelines.
130562 PI-RADS DWI Lesion Assessment Assessment of the lesions characteristics based on its appearance in diffusion-weighted MR images following the Prostate Imaging Reporting and Data System (PI-RADS®) guidelines.
130563 PI-RADS DCE Lesion Assessment Assessment of the lesions characteristics based on its appearance in Dynamic Contrast-enhanced MR images following the Prostate Imaging Reporting and Data System (PI-RADS®) guidelines.
130564 PI-RADS v2.0 Prostate Imaging Reporting and Data System (PI-RADS®) version 2.0. .
130565 PI-RADS v2.1 Prostate Imaging Reporting and Data System (PI-RADS®) version 2.1 .
130566 Diffusion-weighted Acquisition Highest b-value image Image from a diffusion-weighted acquisition corresponding to the highest b-value.
130567 Dynamic Contrast-Enhanced Acquisition Image acquisition that involves injection of a contrast agent into the bloodstream.
130568 Dynamic Contrast-Enhanced Acquisition Subtraction image Image obtained as a difference in image intensities between two phases of a dynamic contrast-enhanced acquisition.
130569 Utricle cyst Area of focal dilatation that occurs within the prostatic utricle.
130570 Protocol not followed Imaging protocol was not followed.
130571 Coil placement concern Based on image appearance, the coil was not placed correctly.
130572 Coil selection concern Incorrect coil was selected during MR acquisition.
130573 Study performed did not match request The imaging procedure performed did not correspond to what was requested.
130574 Incomplete study Study is missing data.
130575 Suboptimal patient preparation Some patient preparation procedures were not performed sufficiently with respect to what was expected.
130576 Anatomy coverage incomplete Coverage of the imaged anatomy is not complete.
130577 Poor FOV selection Choice of Field of View size or position is not fit for the purpose of the acquisition.
130578 Poor SNR Signal-to-noise characteristics are insufficient for the purpose of the acquisition.
130579 Poor contrast timing Timing of the contrast injection relative to the timing of the image acquisition was not properly selected.
130580 Inadequate contrast enhancement Contrast enhancement observed in the image is not sufficient for the purpose of the acquisition.
130581 Subtraction image missing The study lacks a sufficient set of subtraction images.
130582 Unwanted subtraction images Extra subtraction image sets are present that are incorrect or confusing.
130583 Expected b-value is missing Diffusion-weighted MR image obtained with an expected b-value is not present.
130584 Severe distortion in the area of interest Severe geometric distortions are present in the image, and are affecting the area of interest in the image.
130585 Expected ADC map is missing Apparent Diffusion parametric map image is missing, but was expected.
130586 Distortion artifact in the area of interest Geometric distortions are present in the image, and are affecting the area of interest in the image.
130587 No family history of prostate cancer There is no history of prostate cancer in the patient’s family.
130588 Pre-biopsy localization of prostate lesion The purpose of imaging is to identify and localize targets suspicious of the presence of prostate cancer prior to biopsy.
130589 Active surveillance of prostate cancer Continual monitoring of a patient with localized prostate cancer, with a view to curative intent, according to locally agreed pathways. After [Kuru 2013]
130590 Assess change The need to detect or measure the amount of change in the condition.
130591 Focal abnormality Abnormality localized at a focus, central point or locus.
130592 Non-focal abnormality Abnormality not localized to a single focus.
130593 Partially encapsulated Partially but not entirely surrounded (bounded) by a distinct tissue layer, such as a smooth low-signal line on MRI.
130594 Completely encapsulated Entirely surrounded (bounded) by a distinct tissue layer, such as a smooth low-signal line on MRI, in more than one spatial dimension (at least two imaging planes).
130595 ADC Hyperintense Having higher signal intensity (more intense, brighter) than background tissue on the apparent diffusion coefficient map.
130596 ADC Hypointense Having lower intensity (darker) than a reference background tissue on apparent diffusion coefficient map.
130597 Persistent delayed phase: Type 1 curve Continued increase of signal intensity over time.
130598 Plateau delayed phase: Type 2 curve Signal intensity does not change over time after its initial rise, flat; plateau refers to signal that varies <10% from the peak signal over the duration of the DCE MRI.
130599 Washout delayed phase: Type 3 curve Signal intensity decreases after its highest point after its initial rise.
130600 Positive DCE Focal, early enhancement corresponding to a focal peripheral zone of transition zone lesion on T2 and/or DWI MRI.
130601 Negative DCE Lack of early enhancement. Diffuse enhancement not corresponding to a focal lesion on T2 and/or DWI MRI. Focal enhancement corresponding to a BPH lesion.
130602 Early Contrast Enhancement Contrast-enhanced is observed in the early stage following contrast injection
130603 Diffuse Contrast Enhancement Contrast enhancement is non-focal and diffused over a region.
130604 Focal Contrast Enhancement Contrast enhancement is concentrated in a focal tissue area.
130605 Perfluorocarbon Class of organofluorine compounds containing only carbon and fluorine.
130606 ESUR 2012 prostate MRI acquisition requirements Prostate MRI technical acquisition requirements defined in .
130607 PI-RADS 2.0 prostate MRI acquisition requirements Prostate MRI technical acquisition requirements defined in PI-RADS® 2.0 .
130608 PI-RADS 2.1 prostate MRI acquisition requirements Prostate MRI technical acquisition requirements defined in PI-RADS® 2.1 .
130609 2D Shear Wave Elastography A high-speed ultrasound imaging technique that quantitatively assesses the stiffness/elasticity of tissue based on the tracking of the propagation of a shear-wave and measuring its velocity over a 2D area.
130610 3D Shear Wave Elastography A high-speed ultrasound imaging technique that quantitatively assesses the stiffness/elasticity of tissue based on the tracking of the propagation of a shear-wave and measuring its velocity over a 3D volume.
130611 Shear Wave Speed The velocity at which a shear-wave propagates through a substance or tissue. The shear wave speed (SWS) is correlated with the elasticity of the substance or tissue.
130612 Shear Wave Dispersion Slope The rate at which shear wave speed is attenuated with changes in the frequency of the shear wave. The dispersion slope is correlated with both the elasticity and the viscosity of the substance or tissue.
130613 ROI Depth Distance from the ultrasound probe surface to the geometric center of the ROI.
130614 Interquartile Range of population The width of the center range within which 50% of the measured values in a reference population fall. The IQR may also be described as the first quartile value subtracted from the third quartile value, or equivalently the 25th percentile value subtracted from the 75th percentile value.
130615 Interquartile Range to Median Ratio of population The interquartile range value of a population divided by the median value of the same population. IQR/M, which is one way to describe the variability of a set of measurements, is sometimes used as a metric of measurement quality.
130616 Point Shear Wave Elastography A high-speed ultrasound imaging technique that quantitatively assesses the stiffness/elasticity of tissue based on the tracking of the propagation of a shear-wave and measuring its velocity at a point.
130620 left ventricle apical anteroseptal segment A segment of wall of the left ventricle at the apical level whose circumferential extent aligns with that of the anteroseptal segments at the mid and basal levels.
130621 left ventricle apical inferoseptal segment A segment of wall of the left ventricle at the apical level whose circumferential extent aligns with that of the inferoseptal segments at the mid and basal levels.
130622 left ventricle apical inferolateral segment A segment of wall of the left ventricle at the apical level whose circumferential extent aligns with that of the inferolateral segments at the mid and basal levels.
130623 left ventricle apical anterolateral segment A segment of wall of the left ventricle at the apical level whose circumferential extent aligns with that of the anterolateral segments at the mid and basal levels.
130630 Isocentric Setup Method Method to position the patient such that the device isocenter is at a specific location in the patient. For a radiotherapeutic treatment, this allows rotational delivery of radiation treatment fields that maintain a focus on that location.
130631 Controlled SSD Setup Method Method to position the patient such that the distance between the radiation source and the patient skin is a specific value.
130632 TBI Setup Method Method to position the patient at an extended distance from the radiation source, typically 2-6 meters, to create a large treatment field for total body irradiation (TBI).
130633 Stereotactic Setup Method Method to position the patient using high-accuracy localization imaging from multiple angles. Typically combined with rigorous fixation to reduce patient motion.
130634 Skin Apposition Setup Method Method to position the patient using three-dimensional skin surface registration.
130635 Ocular Gaze Setup Method Method to set up the patient for ocular treatments by focusing the patient’s gaze on a particular location.
130636 Patient Shielding Procedure Preparation procedure to set up devices to shield parts of the patient from radiation.
130637 Patient Fixation Procedure Preparation procedure to set up devices to fixate parts of the patient. Fixation involves both preventing motion of the patient part and putting the patient part into an intended configuration.
130638 Patient Alignment Procedure Preparation procedure to orient and position parts of the patient with respect to a physical reference.
130639 Patient Motion Management Setup Procedure Preparation procedure for controlling or compensating for motion of parts of the patient.
130640 Cavity radiation shield Device to protect anatomical structures within a body cavity.
130641 Independent radiation shield A radiation shielding device that is not in contact with the patient or the treatment delivery device.
130642 Optical Distance Meter An optical distance measuring device.
130643 Mechanical Pointer A mechanical distance measuring device.
130644 Radiofrequency Transponder Radiofrequency-based positioning beacon that responds to interrogation.
130645 Infrared Marker A device that reflects infrared light. Often used to position patients.
130646 Radioactive Marker A device that emits radiation from a radioactive source. Often used to position patients.
130647 Thermal Imager A device that produces a temperature map.
130648 Combined Structured Light/Thermal Imager A device that projects a controlled pattern of light and captures data based on infrared and visible light measurements.
130649 Ocular Fixation Light A light to which the patient’s gaze is aligned.
130650 Coaching Device Device to help patients to follow certain instructions.
130651 Patient Distraction Device Device to hold the attention of the patient. May be used to reduce the anxiety or discomfort of the patient during a procedure.
130652 Collision checks Procedure to minimize risk of collision between a primary device, the patient, and associated devices.
130653 Breast Bridge Device used to position the breast.
130654 Abdominal Compression Belt Belt used to limit abdominal motion by compressing the abdomen.
130655 Abdominal Compression Arch Arch-shaped device used to limit abdominal motion by maintaining pressure on the abdomen.
130656 Head Fixation Board A board to which the patient’s head is fixed to prevent the patient from moving relative to the tabletop. Typically the patient’s head is fixed with a mask.
130657 Couch Index Label A label designating a specific location on an patient support table top.
130658 Fixation Device Angle Positioning angle on a fixation device with a single degree of angular freedom.
130659 Abdominal Compression Plate Position Number The number indicating the position of the plate of an abdominal compression device.
130660 Abdominal Compression Belt Length Length of the part of the abdominal compression belt being used to compress the abdomen.
130661 Abdominal Compression Belt Pressure Pressure applied to the abdomen by the abdominal compression belt.
130662 Referenced Patient Alignment Reference References to SOP Instances providing the basis for patient alignment. May contain the intended orientation. The basis for alignment is also referred to as the alignment reference.
130663 RT Radiation previously delivered The RT Radiation has been already delivered in a previous Treatment Session.
130664 Treatment unnecessary It has been assessed that the delivery of the Treatment is unnecessary to meet the current treatment goals.
130665 Treatment exceeds patient tolerance It has been assessed that the delivery of the Treatment would result in effects that exceed the physical or psychological tolerance of the patient.
130666 Radiotherapy Fiducial Fiducial defined or used during a radiotherapeutic procedure, e.g., treatment planning or positioning.
130670 Longitudinal Lagrangian Strain Lagrangian strain parallel to the reference contour (i.e. in the longitudinal direction) calculated as: SL(t)=(L(t) -L0)/L0, where L(t) is the length at a given point t in time and L0 is the reference length at the reference time t0.Strain values are negative with shortening. Due to the common convention of using end-diastole as the t0 reference time, echocardiography strain values are typically negative.
130671 Peak Longitudinal Lagrangian Strain Peak value of longitudinal Lagrangian strain during an identified interval, such as systole or a full cardiac cycle.
130672 Time to Peak Longitudinal Lagrangian Strain The time from the beginning of the interval to the time of the peak longitudinal Lagrangian strain.
130673 Mechanical Dispersion The standard deviation of the time to peak longitudinal strain value for different myocardial segments. Typically assessed over 18-segments of the left ventricle.
130674 Longitudinal Lagrangian Strain Rate Rate of change of longitudinal strain over time.
130675 Radial Lagrangian Strain Lagrangian strain in the wall of a cavity perpendicular to the longitudinal strain and towards the center of the cavity.
130676 Radial Lagrangian Strain Rate Rate of change of radial Lagrangian strain over time.
130677 Circumferential Lagrangian Strain Lagrangian strain tangential to the reference contour, perpendicular to the longitudinal strain, with positive values in the counterclockwise direction when viewed from the apex.
130678 Circumferential Lagrangian Strain Rate Rate of change of circumferential Lagrangian strain over time.
130679 2D Speckle Tracking A method of analyzing the motion of tissue, such as the heart muscle or blood, by using naturally occurring speckle patterns in 2D ultrasound imaging.
130680 3D Speckle Tracking A method of analyzing the motion of tissue, such as the heart muscle or blood, by using naturally occurring speckle patterns in 3D ultrasound imaging.
130681 Apical four chamber RV Focused A view obtained from the apical four chamber view by angling the beam medially toward the patient’s right shoulder to better include the right ventricle.
130682 Apical four chamber RV Modified A view obtained from the apical four chamber view by angling the beam laterally toward the patient’s left shoulder to better include the right ventricle.
130683 Endocardial Method A measurement method that uses a contour representing the estimated endocardial boundary.
130684 Epicardial Method A measurement method that uses a contour representing the estimated epicardial boundary.
130685 Myocardial Midlayer Method A measurement method that uses a contour representing the estimated mid-layer of the myocardium (between the endocardium and epicardium).
130686 LV End-systolic GLS Multiview Mean (Endocardial) The longitudinal Lagrangian strain of the left ventricle calculated as the arithmetic mean of LV End-systolic Global Longitudinal Strain 4CH (Endocardial), LV End-systolic Global Longitudinal Strain 2CH (Endocardial), and LV End-systolic Global Longitudinal Strain ALAX (Endocardial).
130687 LV End-systolic GLS 4CH (Endocardial) The longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical four chamber view at end systole using the endocardial method.The measurement may have been taken at any point in the respiration cycle.Sometimes abbreviated GLS4C.
130688 LV End-systolic GLS 2CH (Endocardial) The longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical two chamber view at end systole using the endocardial method.The measurement may have been taken at any point in the respiration cycle.Sometimes abbreviated GLS2C.
130689 LV End-systolic GLS ALAX (Endocardial) The longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical long axis view at end systole using the endocardial method.The measurement may have been taken at any point in the respiration cycle.Sometimes abbreviated GLSALAX.
130690 LV Peak Systolic GLS Multiview Mean (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle calculated as the arithmetic mean of LV Peak Systolic Global Longitudinal Strain 4CH (Endocardial), LV Peak Systolic Global Longitudinal Strain 2CH (Endocardial), and LV Peak Systolic Global Longitudinal Strain ALAX (Endocardial).
130691 LV Peak Systolic GLS 4CH (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical four chamber view during systole using the endocardial method.The measurement may have been taken at any point in the respiration cycle.
130692 LV Peak Systolic GLS 2CH (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical two chamber view during systole using the endocardial method.The measurement may have been taken at any point in the respiration cycle.
130693 LV Peak Systolic GLS ALAX (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical long axis view during systole using the endocardial method.The measurement may have been taken at any point in the respiration cycle.
130694 LV Peak GLS Multiview Mean (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle calculated as the arithmetic mean of LV Peak Global Longitudinal Strain 4CH (Endocardial), LV Peak Global Longitudinal Strain 2CH (Endocardial), and LV Peak Global Longitudinal Strain ALAX (Endocardial).
130695 LV Peak GLS 4CH (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical four chamber view over the cardiac cycle using the endocardial method.The measurement may have been taken at any point in the respiration cycle.
130696 LV Peak GLS 2CH (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical two chamber view over the cardiac cycle using the endocardial method.The measurement may have been taken at any point in the respiration cycle.
130697 LV Peak GLS ALAX (Endocardial) The peak longitudinal Lagrangian strain of the left ventricle measured along the entire myocardial length in 2D Speckle mode in the apical long axis view over the cardiac cycle using the endocardial method.The measurement may have been taken at any point in the respiration cycle.
130698 LV End-systolic Mechanical Dispersion The mechanical dispersion of the left ventricle in 2D Speckle mode at end systole.The measurement may have been taken using any view, using any segment model (16, 17 or 18-segment) and at any point in the respiration cycle.
130699 Mitral Valve Closure The point in time in a cardiac cycle when the mitral valve nominally finishes closing.
130700 Mitral Valve Opening The point in time in a cardiac cycle when the mitral valve nominally begins opening.
130701 Aortic Valve Closure The point in time in a cardiac cycle when the aortic valve nominally finishes closing.
130702 Aortic Valve Opening The point in time in a cardiac cycle when the aortic valve nominally begins opening.
130710 Fp9 EEG electrode placement on the head located inferior frontopolar, left.
130711 Fp10 EEG electrode placement on the head located inferior frontopolar, right.
130712 AF9 EEG electrode placement on the head located inferior anterior frontal, left.
130713 AF10 EEG electrode placement on the head located inferior anterior frontal, right.
130714 PO9 EEG electrode placement on the head located inferior parietooccipital, left.
130715 PO10 EEG electrode placement on the head located inferior parietooccipital, right.
130716 O9 EEG electrode placement on the head located inferior occipital, left.
130717 O10 EEG electrode placement on the head located inferior occipital, right.
130720 Coronary Artery Disease Assessment
130721 oronary Artery Disease Assessment Modifier
130722 Coronary Artery Disease Stenosis Assessment Modifier
130723 0 - Documented absence of CAD Degree of maximal coronary stenosis is 0%.
130724 1 - Minimal non-obstructive CAD Degree of maximal coronary stenosis is 1-24%.
130725 2 - Mild non-obstructive CAD Degree of maximal coronary stenosis is 25-49%.
130726 3 - Moderate stenosis Degree of maximal coronary stenosis is 50-69%.
130727 4 - Severe stenosis Degree of maximal coronary stenosis is 70-99%, or left main coronary stenosis is >50%, or coronary stenosis is >=70% in 3 vessels.
130728 4A - Severe stenosis Degree of maximal coronary stenosis is 70-99% stenosis.
130729 4B - Severe stenosis Left main coronary stenosis is >50% or coronary stenosis is >=70% in 3 vessels.
130730 5 - Total coronary occlusion Degree of maximal coronary stenosis is 100% (total occlusion).
130731 N - Non-diagnostic study No more than mild coronary stenosis in interpretable segments, and one or more vessel segments non-diagnostic.
130732 N - Non-diagnostic segments One or more vessel segments were non-diagnostic for coronary stenosis.
130733 S - Stent At least one coronary stent is present in the coronary system.
130734 G - Graft At least one coronary artery bypass graft is present.
130735 V - Vulnerable plaque Vulnerable plaque or high risk plaque features are present.
130736 Titanium alloy (Titanium Molybdenum-15 Zirconium-5 Aluminium-3) Wrought titanium 15-molybdenum 5-zirconium 3-aluminium alloy.
130737 RT Segment Material Material identifiers used during or for an RT planning process.
130738 Dose Limit Interlock An interlock triggered by reaching a predefined dose limit.
130739 Clearance Interlock An interlock triggered by the occurrence, or anticipation, of a physical collision caused by lack of separation distance between objects.
130740 Machine Clearance Interlock An interlock triggered by the occurrence, or anticipation, of a physical collision caused by lack of separation distance between machine and machine.
130741 Patient Clearance Interlock An interlock triggered by the occurrence, or anticipation, of a physical collision caused by lack of separation distance between machine and patient.
130742 Accessory Clearance Interlock An interlock triggered by the occurrence, or anticipation, of a physical collision caused by lack of separation distance between an accessory and the machine, patient or another accessory.An accessory can be e.g., an electron applicator or a stereotactic cone.
130743 Out of Tolerance Interlock An interlock triggered by an actual value being out of tolerance from the planned value.
130744 Interlock Resolved The interlock was resolved, and treatment delivery was continued.
130745 CT Dose Length Product Sub-Total The total dose length product for irradiation events within in the defined scope of accumulation that were computed using the same phantom.
130746 RT Registration Mark Marker used in a registration process.
130747 Isodose Volume A volume whose surface represents an isodose.
130748 Radiotherapy Dose Region Region defined by the spatial extent of a radiation dose.
130750 Quality control material image Images that contain quality control material for the current procedure.
130751 Tissue not of interest Tissue that is other than that which is of interest for the purpose of the task.
130752 Data Not Accessible from Storage Requested data cannot be read from storage media, e.g., data physically deleted, or storage media no longer available.
130753 Processed Key Object Selection The SOP Instance is a Key Object Selection Document, used for referenced object change management, that has had its directives processed and is no longer to be used (see .
130754 Replaced by Alternate Representation The SOP Instance has been replaced by a SOP Instance with an alternate encoding. The alternate encoding may utilize a different SOP Class or have different image quality characteristics (e.g., lossy compression).
130755 Reference Measurement Group A grouping of related measurements and calculations that share a common context and that serves as a reference against which similar measurement groups are compared.
130756 Particle Displacement Method A method for detecting a shear wave in ultrasound data based on the displacement of particles relative to their referenced baseline positions.
130757 Particle Velocity Method A method for detecting a shear wave in ultrasound data based on estimated particle velocity. Particle velocity is estimated from frame to frame particle displacement.
130758 Shear Wave Dispersion Slope Center Frequency The center frequency of the range over which the shear wave dispersion slope was assessed.
130759 Shear Wave Detection Method Method used to detect and characterize a shear wave motion signal in an ultrasound signal.
130760 Butterworth filter A signal processing filter of the Butterworth type.
130761 Chebyshev filter A signal processing filter of the Chebyshev type.
130762 Elliptic filter An elliptic signal processing filter.
130763 Bessel filter A signal processing filter of the Bessel type.
130764 Gaussian filter A signal processing filter of the Gaussian type
130765 K-type filter A K-type (constant k) signal processing filter.
130766 M-derived filter An M-derived (m-type) signal processing filter.
130767 Double-m-derived filter A double-m-derived (mm'-type) signal processing filter.
130768 Bode filter A signal processing filter of the Bode type.
130769 Zobel filter A signal processing filter of the Zobel type.
130770 FIR filter A finite impulse response (FIR) signal processing filter.
130771 CIC filter A cascaded integrator–comb (CIC) signal processing filter.
130772 IIR filter An infinite impulse response (IIR) signal processing filter.
130773 Biquad filter A biquadratic signal processing filter (second order recursive linear filter).
130774 Hz normalized Frequency in Hz divided by ½ of the sampling rate.
130775 Hz angular Frequency in Hz divided by ½ of the sampling rate and then multiplied by π (pi).
130776 Magnitude normalized Ratio of output magnitude to input magnitude, has no units and a value between 0-1.
130780 Specific observation subject class The type of entity that is the subject of a specific observation, such as a measurement or qualitative evaluation.
130781 Image frame A single two-dimensional pixel plane of an image.Usually used in the context of a multi-frame image.
130782 RT Patient Position Acquisition, Integrated Dose MV Acquisition of patient positioning information using continuous megavoltage acquisition during treatment delivery.
130783 RT Patient Position Acquisition, Film Cassette MV Acquisition of patient positioning information using a radiation-sensitive film suited for megavoltage radiation.
130784 RT Patient Position Acquisition, Film Cassette kV Acquisition of patient positioning information using a radiation-sensitive film suited for photon radiation.
130785 RT Patient Position Acquisition, Cone-Beam CT kV Acquisition of patient positioning information using kilovoltage Cone-Beam CT imaging.
130786 RT Patient Position Acquisition, Conventional CT kV Acquisition of patient positioning information using kilovoltage conventional CT imaging.
130787 RT Patient Position Acquisition, Cone-Beam CT MV Acquisition of patient positioning information using megavoltage Cone-Beam CT imaging.
130788 RT Patient Position Acquisition, Conventional CT MV Acquisition of patient positioning information using megavoltage conventional CT imaging.
130789 Nominal Imaging Source Location The point location defined as the nominal source of radiation used for imaging.
130790 RT Patient Positioning Reference Image Image(s) of the patient used to provide a reference for positioning of the patient for the planned treatment.
130791 Acquisition Initiation Type The type of method used to start the acquisition.
130792 Acquisition Initiation not defined The acquisition trigger is not specified. Acquisition may be initiated manually by the device operator.
130793 Acquisition Initiation before start of Radiation The acquisition is started before delivering the therapeutic radiation. It is expected that the therapeutic beam is not started before the acquisition is completed.
130794 Acquisition Initiation after end of Radiation The acquisition is started after delivering the therapeutic radiation.
130795 Acquisition Initiation by triggering parameter The acquisition is started when the triggering parameter reaches specific value(s).
130796 Incremental Acquisition Triggering Flag denoting whether the acquisition is to be repeated in regular intervals separated by a certain increment.
130797 Meterset A single parameter from which the absorbed dose delivered can be calculated through a calibration procedure with additional information.
130798 Source Continuous Roll Angle Angle in degrees about the Y-axis of the Equipment Coordinate System by which the source is rotated. A Continuous Rotation Angle is an angle in the range (-∞,+∞). Continuous Rotation Angle represent a rotation direction and magnitude. The magnitude is not limited to be between 0 and 360 degrees.
130799 Time after start of Radiation Time elapsed after the start of the delivery of an RT Radiation.
130800 Percentage of expected beam-on time of Radiation Delivered percentage of the duration of a Radiation at a given point in time. The denominator is the duration of time that the beam is expected to be on between the start and the end of the delivery of an RT Radiation. The numerator is the duration of time that the beam has been on since the start of the first beam-on. Both durations exclude “beam-hold” periods within the treatment delivery (e.g. during gated treatments).
130801 IEC61217 Imaging Source to Axis Distance Distance from the imaging source, in mm, to the gantry rotation axis of a IEC C-Arm Device. This parameter is not specifically defined by , but is consistent with
130802 IEC61217 X-Ray Image Receptor Radial Displacement from Isocenter X-Ray Image Receptor Radial Displacement From Isocenter, in mm (in the IEC GANTRY Coordinate System) as defined by .
130803 IEC61217 X-Ray Image Receptor Longitudinal Displacement X-Ray Image Receptor Longitudinal Displacement, in mm (in the IEC GANTRY Coordinate System) as defined by .
130804 IEC61217 X-Ray Image Receptor Lateral Displacement X-Ray Image Receptor Lateral Displacement, in mm (in the IEC GANTRY Coordinate System) as defined by .
130805 IEC61217 X-Ray Image Receptor Rotation X-Ray Image Receptor rotation (around the z-axis of the IEC X-RAY IMAGE RECEPTOR Coordinate System) as defined by . DICOM represents this value as a Continous Rotation Angle in degrees.
130806 Configured Lowest Imaging Energy Lowest energy for acquiring an image as configured on the device.
130807 Configured Default Imaging Energy Default energy for acquiring an image as configured on the device.
130808 Planar matrix ultrasound transducer geometry Ultrasonic transducer geometry characterized by multiple transducer elements arranged in a grid on a plane.
130809 Hemispherical ultrasound transducer geometry Ultrasonic transducer geometry characterized by multiple transducer elements arranged on a hemispherical surface.
130810 Single-side illumination The subject is illuminated from a single direction.
130811 Dual-side illumination The subject is illuminated from two distinct directions.
130812 Multi-side illumination The subject is illuminated from more than two (potentially a very large number of) distinct directions.
130813 Through-transducer illumination The subject is illuminated through the transducer. Light may pass through the transducer at one or more locations.
130814 Interstitial illumination The subject is illuminated internally. Light is delivered via a device (other than the transducer) inside the body.
130815 Piezocomposite Transducer Ultrasound Transducer that utilizes Piezo-composite crystalline structures.
130816 MEMS-based Transducer Ultrasound Transducer that utilizes Micro-electro-mechanical systems (MEMS)-based structures.
130817 Interferometric Transducer Ultrasound Transducer that utilizes interferometric detection systems.
130818 Uniform Speed of Sound Correction Mechanism for correction of data using a sound propagation model based on a single speed of sound, where the speed for the acoustic coupling medium (if present) is assumed to be the same as for the imaged object.
130819 Dual Speed of Sound Correction Mechanism for correction of data using a sound propagation model based on two speeds of sound, one for the acoustic coupling medium and one for the imaged object.
130820 Speed of Sound Map Correction Mechanism for correction of data using a sound propagation model based on a speed of sound map that defines the speed of sound on a per-pixel basis.
130821 Spherical Back Projection A family of algorithms for reconstructing an image from measured data by back-projection over spheres or parts of spheres. May include linear or nonlinear processing steps before and/or after the back-projection step. Includes methods termed ‘beamforming’ and ‘delay-and-sum’.
130822 Numerical Acoustic Model A family of algorithms for reconstructing an image from measured data by iteratively adjusting the image to minimize a cost function between the data and a numerical model or that uses non-iterative (e.g. time-reversal) methods, or that performs inversion of a forward model matrix.
130823 Blood Deoxygenation Level Signal intensity of a Blood Deoxygenation Level image.

Produced 08 Sep 2023