Code
|
Display
|
Definition
|
BMD
|
Bone Mineral Densitometry |
An acquisition device, process or method that performs bone mineral densitometry by X-Ray, including dual-energy X-Ray absorptiometry (DXA) and morphometric X-Ray absorptiometry (MXA). |
EOG
|
Electrooculography |
An acquisition device, process or method that performs electrooculography. |
SM
|
Slide Microscopy |
An acquisition device, process or method that performs slide microscopy. |
OP
|
Ophthalmic Photography |
An acquisition device, process or method that performs ophthalmic photography. |
FILMD
|
Film Digitizer |
A device, process or method that performs film digitization. |
WSD
|
Workstation |
A networked computer equipped with a display and software for performing specific types of work, generally intended to be operated by a single user. |
ECG
|
Electrocardiography |
An acquisition device, process or method that performs electrocardiography. |
GM
|
General Microscopy |
An acquisition device, process or method that performs general microscopy. |
XA
|
X-Ray Angiography |
An acquisition device, process or method that performs X-Ray angiography. |
XC
|
External-camera Photography |
An acquisition device, process or method that performs photography with an external camera. |
DMS
|
Dermoscopy |
An acquisition device, process or method that performs imaging of the surface of the skin using epiluminescence microscopy. |
IVUS
|
Intravascular Ultrasound |
An acquisition device, process or method that performs intravascular ultrasound. |
CR
|
Computed Radiography |
An acquisition device, process or method that performs computed radiography. |
COMP
|
Computation Server |
A device, process or method that performs computation as a service; includes radiotherapy planning. |
MCD
|
Media Creation Device |
A device, process or method that creates DICOM interchange media. |
CT
|
Computed Tomography |
An acquisition device, process or method that performs computed tomography. |
PA
|
Photoacoustic |
An acquisition device, process or method that performs imaging by means of tissue excitation through the absorption of short light pulses and detection of the resultant acoustic emission. |
OSS
|
Optical Surface Scanner |
An acquisition device, process or method that performs optical surface scanning. |
TG
|
Thermography |
An acquisition device, process or method that performs thermography. |
LEN
|
Lensometry |
An acquisition device, process or method that performs lensometry. |
OPTENF
|
Ophthalmic Tomography En Face |
An acquisition device, process or method that creates en face tomography images of the eye based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded. |
HD
|
Hemodynamic Waveform |
An acquisition device, process or method that records hemodynamic waveforms. |
OCT
|
Optical Coherence Tomography |
An acquisition device, process or method that uses an interferometric, non-invasive optical tomographic technique to image 2D slices and 3D volumes of tissue using visible and near visible frequencies. |
M3D
|
3D Manufacturing Modeling System |
A device, process or method that produces data (models) for use in 3D manufacturing. |
BDUS
|
Ultrasound Bone Densitometry |
An acquisition device, process or method that performs ultrasound bone densitometry. |
DG
|
Diaphanography |
An acquisition device, process or method that performs diaphanography. |
PT
|
Positron emission tomography |
An acquisition device, process or method that performs positron emission tomography (PET). |
EPS
|
Cardiac Electrophysiology |
An acquisition device, process or method that performs cardiac electrophysiology. |
LS
|
Laser Scan |
An acquisition device, process or method that performs laser surface scanning. |
PRINT
|
Hard Copy Print Server |
Hard Copy Print Server; includes printers with embedded DICOM print server. |
PX
|
Panoramic X-Ray |
An acquisition device, process or method that performs panoramic X-Rays. |
OPM
|
Ophthalmic Mapping |
An acquisition device, process or method that measures corneal topography, corneal or retinal thickness, and other similar parameters that are typically displayed as maps. |
OPTBSV
|
Ophthalmic Tomography B-scan Volume Analysis |
An acquisition device, process or method that performs B-scan volume analysis of tomography images of the eye based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded. |
OPV
|
Ophthalmic Visual Field |
An acquisition device, process or method that measures visual fields and perform visual perimetry. |
DX
|
Digital Radiography |
An acquisition device, process or method that performs digital radiography. |
OPT
|
Ophthalmic Tomography |
An acquisition device, process or method that performs tomography of the eye that is based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded. |
MG
|
Mammography |
An acquisition device, process or method that performs mammography. |
US
|
Ultrasound |
An acquisition device, process or method that performs ultrasound. |
EMG
|
Electromyography |
An acquisition device, process or method that performs electromyography. |
IVOCT
|
Intravascular Optical Coherence Tomography |
An acquisition device, process or method that performs intravascular optical coherence tomography |
DSS
|
Department System Scheduler |
A department-based information system (for instance, Radiology or Laboratory) that provides functions related to the management of orders received from external systems or through the department system’s user interface. This definition matches that of the DSS/OF Actor in the IHE Scheduled Workflow (SWF) Profile. |
LOG
|
Procedure Logging |
A device, process or method that performs procedure Logging; includes cath lab logging. |
MR
|
Magnetic Resonance |
An acquisition device, process or method that performs magnetic resonance imaging. |
IO
|
Intra-oral Radiography |
An acquisition device, process or method that performs intra-oral radiography. |
CAD
|
Computer Assisted Detection/Diagnosis |
An image processing device, process or method that performs computer assisted detection or diagnosis. |
EEG
|
Electroencephalography |
An acquisition device, process or method that performs electroencephalography. |
RTIMAGE
|
RT Image |
An acquisition device, process or method that performs radiotherapy imaging; includes portal imaging. |
VA
|
Visual Acuity |
An acquisition device, process or method that measures visual acuity. |
RESP
|
Respiratory Waveform |
A device, process or method that produces waveforms of electrical signals from the patient’s respiratory system. |
ES
|
Endoscopy |
An acquisition device, process or method that records images during endoscopy. |
AR
|
Autorefraction |
An acquisition device, process or method that measures autorefraction. |
POS
|
Position Sensor |
A device or sensor measuring the orientation of the patient’s body. |
RG
|
Radiographic imaging |
An acquisition device, process or method that performs radiographic imaging (conventional film/screen). |
RF
|
Radiofluoroscopy |
An acquisition device, process or method that performs radiofluoroscopy. |
KER
|
Keratometry |
An acquisition device, process or method that performs keratometry. |
ARCHIVE
|
Archive |
A device, process or method that stores images and other objects for a prolonged period of time. |
CAPTURE
|
Image Capture |
An acquisition device, process or method that performs image capture, includes video capture. |
STAIN
|
Automated Slide Stainer |
A device, process or method that applies, in an automated manner, a stain, or reagent, to microscopy slides in preparation for imaging. |
OAM
|
Ophthalmic Axial Measurements |
An acquisition device, process or method that measures the axial length of the eye. |
NM
|
Nuclear Medicine |
An acquisition device, process or method that performs nuclear medicine imaging. |
RT
|
Radiation Therapy Device |
A device, process or method that delivers radiation therapy; includes linear accelerator, proton therapy. |
BI
|
Biomagnetic Imaging |
An acquisition device, process or method that performs biomagnetic imaging. |
SRF
|
Subjective Refraction |
An acquisition device, process or method that records subjective refraction. |