Code
|
Display
|
Definition
|
130160
|
Terminated due to unspecified injector failure |
The injector device detected an unspecified failure and automaticallyterminated the administration. |
130164
|
Syringe detached |
The injector device detected that a syringe was detached from the injector. |
130163
|
Syringe attached |
The injector device detected that a syringe was attached to the injector. |
130162
|
Keep vein open ended |
The injector device ended saline flow for the purpose of keeping vein open. |
130161
|
Keep vein open started |
The injector device started saline flow for the purpose of keeping vein open. |
130267
|
Manual hold started |
A manual intervention of the technologist initiated an injector hold/wait state. |
130266
|
Programmed hold started |
A programmed administration phase initiated an injector hold/wait state. |
130269
|
Terminated hold due to timeout |
The injector terminated injection processing from hold/wait after exceeding a time limit. |
130268
|
Manual resume from hold |
A manual intervention of the technologist has resumed injector fluid administration. It does not matter if the hold/wait state was initiated programmed or manually. |
130153
|
Flow rate above adjustment limit |
The injector device detected a flow rate above the adjustment limit, took compensating action and did not automatically terminate the administration. |
130175
|
Air detected |
The injector device detected air in the tubing or syringe before or during the Imaging Agent administration and did not automatically terminate the administration. |
130152
|
Flow rate above warning limit |
The injector device detected a flow rate above the warning threshold, generated a warning and did not automatically terminate the administration. |
130151
|
Pressure above adjustment limit |
The injector device detected a pressure above the adjustment limit, took compensating action and did not automatically terminate the administration. |
130150
|
Pressure above warning limit |
The injector device detected a pressure above the warning threshold, generated a warning and did not automatically terminate the administration. |
130157
|
Terminated due to flow rate above termination limit |
The injector device detected a flow rate above the termination limit and automatically terminated the administration. |
130179
|
Terminated due to consumable removal |
The injector device detected removal of a consumable from the injector device and terminated the administration. |
130156
|
Terminated due to pressure above termination limit |
The injector device detected a pressure above the termination limit and automatically terminated the administration. |
130178
|
Terminated due to critical battery level |
The injector device detected critical battery level and terminated the administration. |
130155
|
Fixed duration pause ended |
The device detected that a pause duration has been reached and the device resumed automatically. |
130177
|
Terminated by scanner |
The injector device received instruction from scanner to terminate the administration and terminated the administration. |
110501
|
Equipment failure |
Equipment failure prevented completion of procedure. |
130176
|
Terminated due to air detected |
The injector device detected air in the tubing or syringe and terminated the administration. |
130154
|
Terminated due to request from operator |
The injector device terminated the administration due to detection of an abort request by the operator. |
130159
|
Terminated due to injector communication loss |
The injector device detected a communication loss and automaticallyterminated the administration. |
130158
|
Terminated due to excessive duration pause |
The Injector device detected that a pause duration has exceeded limit and the injector device terminated the administration. |
110527
|
Resource inadequate |
Procedure discontinued due to necessary equipment, staff or other resource being inadequate to complete the procedure. |