Code
|
Display
|
Definition
|
109859
|
TG18-LPV50 Pattern |
The AAPM TG18-LPV50 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 50% background level of the maximum pixel value.See . |
109856
|
TG18-LPH50 Pattern |
The AAPM TG18-LPH50 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 50% positive contrast against 10% background level of the maximum pixel value.See . |
109855
|
TG18-LPH10 Pattern |
The AAPM TG18-LPH10 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 10% background level of the maximum pixel value.See . |
109858
|
TG18-LPV10 Pattern |
The AAPM TG18-LPV10 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 10% background level of the maximum pixel value.See . |
109857
|
TG18-LPH89 Pattern |
The AAPM TG18-LPH89 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 89% background level of the maximum pixel value.See . |
109852
|
TG18-RV89 Pattern |
The AAPM TG18-RV89 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 89% luminance level.See . |
109851
|
TG18-RV50 Pattern |
The AAPM TG18-RV50 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 50% luminance level.See . |
109854
|
TG18-CX Pattern |
The AAPM TG18-CX Pattern used to assess display resolution and resolution uniformity.See . |
109853
|
TG18-PX Pattern |
The AAPM TG18-PX Pattern used for the assessment of display resolution.See . |
109850
|
TG18-RV10 Pattern |
The AAPM TG18-RV10 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 10% luminance level.See . |
109908
|
BN05 Pattern |
The IEC BN05 Pattern is used as an alternative to the TG18-LN-05 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109907
|
BN04 Pattern |
The IEC BN04 Pattern is used as an alternative to the TG18-LN-04 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109909
|
BN06 Pattern |
The IEC BN06 Pattern is used as an alternative to the TG18-LN-06 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109904
|
BN01 Pattern |
The IEC BN01 Pattern is used as an alternative to the TG18-LN-01 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109903
|
GD Pattern |
The IEC GD Pattern used for geometrical image evaluation.See . |
109906
|
BN03 Pattern |
The IEC BN03 Pattern is used as an alternative to the TG18-LN-03 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109905
|
BN02 Pattern |
The IEC BN02 Pattern is used as an alternative to the TG18-LN-02 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109867
|
TG18-GQ Pattern |
The TG18-GQ Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GV except that is lacks the central low-contrast objects.See . |
109866
|
TG18-GVN Pattern |
The TG18-GVN Pattern used to assess display veiling. This pattern is identical to AAPM TG18-GV Pattern except that the large-diameter white circle is replaced with a black circle, creating a completely black pattern except for the presence of low-contrast targets.See . |
109869
|
TG18-GQB Pattern |
The TG18-GQB Pattern used for the quantitative assessment of veiling glare. This pattern is identical to AAPM TG18-GQ Pattern except eliminating the central black circle.See . |
109902
|
ANG Pattern |
The IEC ANG Pattern used for angular viewing evaluation.See . |
109868
|
TG18-GQN Pattern |
TG18-GQN Pattern used for the quantitative assessment of veiling glare. This pattern is identical to AAPM TG18-GQ Pattern except that the large-diameter white circle is replaced with a black circle, creating a completely black pattern except for the presence of low-contrast targets.See . |
109901
|
OIQ Pattern |
The IEC OIQ Pattern is used as an alternative to the TG18-QC Pattern.See . |
109863
|
TG18-NS50 Pattern |
The AAPM TG18-NS50 Pattern is AAPM TG18-RV50/RH50 with only difference being the absence of the single line at the center of the measurement area.See . |
109862
|
TG18-NS10 Pattern |
The AAPM TG18-NS10 Pattern is AAPM TG18-RV10/RH10 with only difference being the absence of the single line at the center of the measurement area.See . |
109865
|
TG18-GV Pattern |
The TG18-GV Pattern used to assess display veiling.See . |
109864
|
TG18-NS89 Pattern |
The AAPM TG18-NS89 Pattern is AAPM TG18-RV89/RH89 with only difference being the absence of the single line at the center of the measurement area.See . |
109861
|
TG18-AFC Pattern |
The AAPM TG18-AFC Pattern used to assess display noise.See |
109860
|
TG18-LPV89 Pattern |
The AAPM TG18-LPV89 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 89% background level of the maximum pixel value.See . |
109838
|
TG18-LN12-16 Pattern |
The 16th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109837
|
TG18-LN12-15 Pattern |
The 15th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109839
|
TG18-LN12-17 Pattern |
The 17th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109834
|
TG18-LN12-12 Pattern |
The 12th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109833
|
TG18-LN12-11 Pattern |
The 11th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109836
|
TG18-LN12-14 Pattern |
The 14th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109835
|
TG18-LN12-13 Pattern |
The 13th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109830
|
TG18-LN12-08 Pattern |
The 8th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109832
|
TG18-LN12-10 Pattern |
The 10th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109831
|
TG18-LN12-09 Pattern |
The 9th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109849
|
TG18-RH89 Pattern |
The AAPM TG18-RH89 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 89% luminance level.See . |
109848
|
TG18-RH50 Pattern |
The AAPM TG18-RH50 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 50% luminance level.See . |
109845
|
TG18-AD Pattern |
The AAPM TG18-AD Pattern used for visual evaluation of the reflection of ambient light from the display.See . |
109844
|
TG18-UNL80 Pattern |
The AAPM TG18-UNL80 Pattern is the AAPM TG-18 UN80 Pattern with added defining lines.See . |
109847
|
TG18-RH10 Pattern |
The AAPM TG18-RH10 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 10% luminance level.See . |
109846
|
TG18-MP Pattern |
The AAPM TG18-MP Pattern used for evaluation of Luminance response (bit-depth resolution).See . |
109841
|
TG18-UN10 Pattern |
The AAPM TG18-UN10 Pattern used for evaluation of luminance and color uniformity, and angular response.See . |
109840
|
TG18-LN12-18 Pattern |
The 18th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109843
|
TG18-UNL10 Pattern |
The AAPM TG18-UNL10 Pattern is the AAPM TG-18 UN10 Pattern with added defining lines.See . |
109842
|
TG18-UN80 Pattern |
The AAPM TG18-UN80 Pattern used for evaluation of luminance and color uniformity, and angular response.See . |
109819
|
TG18-LN8-15 Pattern |
The 15th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109816
|
TG18-LN8-12 Pattern |
The 12th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109815
|
TG18-LN8-11 Pattern |
The 11th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109818
|
TG18-LN8-14 Pattern |
The 14th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109817
|
TG18-LN8-13 Pattern |
The 13th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109812
|
TG18-LN8-08 Pattern |
The 8th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109933
|
DIN Resolution Pattern |
Test image "Bild 5" for displaying the spatial and contrast resolution as well as the line structure of imaging devices.See . |
109811
|
TG18-LN8-07 Pattern |
The 7th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109932
|
DIN Grayscale Pattern |
Test image "Bild 3" for the geometrical imaging properties of imaging devices.See . |
109814
|
TG18-LN8-10 Pattern |
The 10th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration series.See . |
109813
|
TG18-LN8-09 Pattern |
The 9th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109810
|
TG18-LN8-06 Pattern |
The 6th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109931
|
DIN Geometry Pattern |
Test image "Bild 2" for the gray-scale reproduction of imaging devices.See . |
109827
|
TG18-LN12-05 Pattern |
The 5th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109826
|
TG18-LN12-04 Pattern |
The 4th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109829
|
TG18-LN12-07 Pattern |
The 7th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109828
|
TG18-LN12-06 Pattern |
The 6th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109823
|
TG18-LN12-01 Pattern |
The 1st image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109822
|
TG18-LN8-18 Pattern |
The 18th image in the AAPM TG18-LN8- set used for DICOM grayscale calibration.See . |
109943
|
SMPTE Pattern |
A standard display test pattern.See .A pattern is available at . |
109825
|
TG18-LN12-03 Pattern |
The 3rd image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109824
|
TG18-LN12-02 Pattern |
The 2 nd image in the AAPM TG18-LN12 set used for DICOM grayscale calibration.See . |
109821
|
TG18-LN8-17 Pattern |
The 17th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109820
|
TG18-LN8-16 Pattern |
The 16th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109941
|
White Pattern |
An alternative to AAPM TG18-UN80, specified at 100% of maximum pixel value. |
109919
|
BN16 Pattern |
The IEC BN16 Pattern is used as an alternative to the TG18-LN-16 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109918
|
BN15 Pattern |
The IEC BN15 Pattern is used as an alternative to the TG18-LN-15 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109915
|
BN12 Pattern |
The IEC BN12 Pattern is used as an alternative to the TG18-LN-12 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109914
|
BN11 Pattern |
The IEC BN11 Pattern is used as an alternative to the TG18-LN-11 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109917
|
BN14 Pattern |
The IEC BN14 Pattern is used as an alternative to the TG18-LN-14 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109916
|
BN13 Pattern |
The IEC BN13 Pattern is used as an alternative to the TG18-LN-13 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109878
|
TG18-CH Image |
The AAPM TG18-CH Image is a reference anatomical PA chest image.See . |
109911
|
BN08 Pattern |
The IEC BN08 Pattern is used as an alternative to the TG18-LN-08 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109877
|
TG18-GA30 Pattern |
The TG18-GA30 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 30.See . |
109910
|
BN07 Pattern |
The IEC BN07 Pattern is used as an alternative to the TG18-LN-07 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109913
|
BN10 Pattern |
The IEC BN10 Pattern is used as an alternative to the TG18-LN-10 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109879
|
TG18-KN Image |
The AAPM TG18-KN Image is a reference anatomical knee image.See . |
109912
|
BN09 Pattern |
The IEC BN09 Pattern is used as an alternative to the TG18-LN-09 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109874
|
TG18-GA15 Pattern |
The TG18-GA15 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 15. |
109873
|
TG18-GA10 Pattern |
The TG18-GA10 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 10.See . |
109876
|
TG18-GA25 Pattern |
The TG18-GA25 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 25.See . |
109875
|
TG18-GA20 Pattern |
The TG18-GA20 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 20.See . |
109870
|
TG18-GA03 Pattern |
The TG18-GA03 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 3.See . |
109872
|
TG18-GA08 Pattern |
The TG18-GA08 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 8.See . |
109871
|
TG18-GA05 Pattern |
The TG18-GA05 Pattern This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 5.See . |
109809
|
TG18-LN8-05 Pattern |
The 5th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109808
|
TG18-LN8-04 Pattern |
The 4th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109805
|
TG18-LN8-01 Pattern |
The 1st image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109804
|
TG18-CT Pattern |
AAPM TG18-CT Pattern used for evaluation of luminance response.See . |
109807
|
TG18-LN8-03 Pattern |
The 3rd image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109806
|
TG18-LN8-02 Pattern |
The 2nd image in the AAPM TG18-LN8 set used for DICOM grayscale calibration.See . |
109801
|
TG18-QC Pattern |
AAPM TG18-QC Pattern used for evaluation of resolution, luminance, distortion, artifacts.See . |
109921
|
BN18 Pattern |
The IEC BN18 Pattern is used as an alternative to the TG18-LN-18 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109803
|
TG18-PQC Pattern |
AAPM TG18-PQC Pattern used for evaluation of resolution, luminance, contrast transfer for prints.See . |
109802
|
TG18-BR Pattern |
AAPM TG18-BR Pattern used for the evaluation of the display of low-contrast, fine-detail image structuresSee . |
109920
|
BN17 Pattern |
The IEC BN17 Pattern is used as an alternative to the TG18-LN-17 Pattern, to avoid the use of a cone or baffle with LCDs.See . |
109881
|
TG18-MM2 Image |
The AAPM TG18-MM2 Image is a reference anatomical mammogram image.See . |
109880
|
TG18-MM1 Image |
The AAPM TG18-MM1 Image is a reference anatomical mammogram image.See . |