Source | nictiz.fhir.nl.stu3.zib2017#2.2.15:Nictiz FHIR NL STU3 Zib2017 (v3.0.2) |
resourceType | StructureDefinition |
id | zib-LaboratoryTestResult-Observation |
canonical | http://nictiz.nl/fhir/StructureDefinition/zib-LaboratoryTestResult-Observation |
version | 2.1.12 |
status | active |
publisher | Nictiz |
name | Zib LaboratoryTestResult Observation |
title | HCIM LaboratoryTestResult Observation |
description | A LaboratoryTestResult as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) version 4.1, release 2017. |
copyright | CC0 |
fhirVersion | 3.0.2 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://fhir.nl/fhir/StructureDefinition/nl-core-observation |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | nl-core-observation | LaboratoryTestResult | ||
context | Encounter during which this observation is made | |||
comment | Comment or ResultInterpretation | |||
related | RelatedResults | |||
target | Reference ( QuestionnaireResponse | Sequence | HCIM LaboratoryTestResult Observation) | |||
identifier | Identifier | |||
basedOn | Fulfills plan, proposal or order including requester information. | |||
status | TestUitslagStatus | |||
Slices for extension | Slice: Unordered, Open by value:url | |||
TestResultStatus | 0..1 | CodeableConcept |
TestResultStatus URL: http://nictiz.nl/fhir/StructureDefinition/code-specification |
|
valueCodeableConcept:valueCodeableConcept |
Binding:
ResultaatStatusCodelijst
( extensible
): TestResultStatusCodelist |
|||
Slices for category | 1 .. | Slice: Unordered, Open by value:$this | ||
category:LaboratoryTestResultCode | 1..1 |
LaboratoryTestResultCode Required Pattern: At least the following |
||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://snomed.info/sct |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 49581000146104 |
|
coding | ||||
display | ||||
category:ResultType | ..1 |
ResultType Binding: ResultaatTypeCodelijst ( required ): ResultaatTypeCodelijst |
||
code | TestCode or PanelOrBattery | |||
subject | Patient | |||
effective[x] | TestDateTime | |||
value[x] | TestResult | |||
interpretation | ||||
Slices for coding | C | 1 .. |
Slice:
Unordered, Open by value:system
zib-LaboratoryTestResult-Observation-1: If a value from the HCIM ValueSet 'InterpretatieVlaggenCodelijst' is present a mapped code from the FHIR ValueSet 'Observation Interpretation Codes' is also expected. A ConceptMap is available that maps the HCIM values to the FHIR values. |
|
coding:ObservationInterpretation |
Binding:
Observation Interpretation Codes
( required
): Observation Interpretation Codes |
|||
system | 1.. | Fixed Value: http://hl7.org/fhir/v2/0078 | ||
code | 1.. | |||
coding:InterpretatieVlaggenCodelijst |
ResultFlags Binding: InterpretatieVlaggenCodelijst ( required ): InterpretatieVlaggenCodelijst |
|||
system | 1.. | Fixed Value: http://snomed.info/sct | ||
code | 1.. | |||
method |
TestMethod Binding: TestmethodeCodelijst ( extensible ): SNOMED CT (2.16.840.1.113883.6.96): All values |
|||
specimen | Reference (HCIM LaboratoryTestResult Specimen | HCIM LaboratoryTestResult Specimen Isolate) | Specimen | ||
device | Reference (HCIM MedicalDevice Product) | |||
referenceRange | Reference | |||
low | ReferenceRangeLowerLimit | |||
high | ReferenceRangeUpperLimit | |||
component | LaboratoryTest | |||
code |
TestCode Binding: TestCodeCodelijst ( extensible ): LOINC (2.16.840.1.113883.6.1): All values |
|||
value[x] | TestResult | |||
interpretation |
ResultFlags Binding: InterpretatieVlaggenCodelijst ( extensible ): InterpretatieVlaggenCodelijst |
|||
Documentation for this format |
Produced 08 Sep 2023