StructureDefinition-cz-observation-imaging

Sourcencez.cz.fhir.imaging#current:CZ Imaging IG (v4.0.1)
resourceTypeStructureDefinition
idcz-observation-imaging
canonicalhttps://www.ncez.mzcr.cz/standards/fhir/imaging/StructureDefinition/cz-observation-imaging
version0.5.0
statusdraft
publisherNárodní centrum elektronického zdravotnictví
nameCZ_ObservationImaging
titleObservation Imaging (CZ)
date2022-09-27T16:57:45+01:00
descriptionCzech profile for an observation in a imaging result report
jurisdictionscz
fhirVersion4.0.1
kindresource
abstractfalse
sdTtypeObservation
derivationconstraint
basehttp://hl7.org/fhir/StructureDefinition/Observation
Usages
Name Flags Card. Type Description & Constraints doco
. . Observation Observation
. . . language S
. . . identifier S
. . . partOf
. . . status S
. . . category S 1..
. . . . Slices for coding S 1 .. Slice: Unordered, Open by value:$this
. . . . . coding:observation-category S 1..1 Required Pattern: At least the following
. . . . . . system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
. . . . . . code 1..1 code Symbol in syntax defined by the system
Fixed Value: imaging
. . . code S Binding: todo ( required )
. . . subject S Reference ( Group | Device | Location | Patient (CZ)) In the initial iteration of the Czech interoperability project: this is Patient (CZ).
. . . effective[x] S C 1.. mii-img-1: Datetime must be at least to day
. . . . effective[x]:All Types Content/Rules for all Types
. . . . . ClinicallyRelevantTime S 0..1 Coding Extension - Clinically Relevant Time
URL: https://www.ncez.mzcr.cz/fhir/img/StructureDefinition/CZ_ClinicallyRelevantTime
Binding: ValueSet - Clinically Relevant Time ( required )
. . . . effectiveDateTime dateTime
. . . . effectivePeriod Period
. . . issued S
. . . performer S Reference ( CareTeam | RelatedPerson | Patient (CZ) | Organization (CZ) | Practitioner Role (CZ) | Practitioner (CZ)) In the initial iteration of the Czech interoperability project: this is Organization (CZ) or Practitioner (CZ)
. . . value[x] S
. . . dataAbsentReason S
. . . interpretation S
. . . note S
. . . bodySite S
. . . method S
. . . specimen S Reference (Specimen Imaging (CZ))
. . . referenceRange S
. . . hasMember S Reference ( QuestionnaireResponse | MolecularSequence | Observation Imaging (CZ)) In the initial iteration of the Czech interoperability project: this is ObservationImaging (CZ)
. . . derivedFrom S Reference ( DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Observation Imaging (CZ)) In the initial iteration of the Czech interoperability project: this can be ObservationLaboratory (CZ) or Media
. . . Slices for component S Slice: Unordered, Open by value:code.coding.code
. . . . component:relativeTimeQualifier 0..1 If a testing code does not include a time interval but needs one to qualify the code.
. . . . . code
. . . . . . coding
. . . . . . . system 1.. Fixed Value: http://snomed.info/sct
. . . . . . . code 1.. Fixed Value: 118578006
. . . . . . . display 1.. Fixed Value: Relative time
. . . . . value[x] 1.. Quantity UCUM
. . . . component:substanceAmountQualifier 0..1 If a testing code does not include a substance amount but needs one to qualify the code
. . . . . code
. . . . . . coding
. . . . . . . system 1.. Fixed Value: http://snomed.info/sct
. . . . . . . code 1.. Fixed Value: 118555000
. . . . . . . display 1.. Fixed Value: Substance amount
. . . . . value[x] 1.. Quantity UCUM
. . . . component:productNameQualifier 0..1 If a testing code does not include a product name but needs one to qualify the code
. . . . . code
. . . . . . coding
. . . . . . . system 1.. Fixed Value: http://snomed.info/sct
. . . . . . . code 1.. Fixed Value: 774167006
. . . . . . . display 1.. Fixed Value: Product name
. . . . . value[x] 1..
. . . . . . valueCodeableConcept CodeableConcept
. . . . . . valueString string

doco Documentation for this format

Produced 08 Sep 2023