Source | hl7.fhir.us.home-lab-report#current:At-Home In-Vitro Test Report (v4.0.1) |
resourceType | StructureDefinition |
id | Observation-at-home-in-vitro-test-result |
canonical | http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Observation-at-home-in-vitro-test-result |
version | 1.0.0 |
status | active |
publisher | Orders and Observations |
name | ObservationAtHomeInVitroTestResult |
title | Observation - At-Home In-Vitro Test Result |
date | 2023-03-25T16:22:59+00:00 |
description | This profile constrains the US Core Laboratory Result Observation to At-Home In-Vitro Sample Tests. |
jurisdictions | us |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | USCoreLaboratoryResultObservationProfile | |||
id | S | 1.. | ||
Extension-at-home-in-vitro-test-proctored-info | 0..1 | (Complex) |
Extension - At-Home In-Vitro Test Proctored Information
URL: http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Extension-at-home-in-vitro-test-proctored-info |
|
status | Fixed Value: final | |||
code | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for each particular use case. | |||
subject | Reference (Patient - At Home In Vitro Test) | |||
effective[x] | S | 1.. | dateTime | |
issued | S | Test result date released | ||
performer | S | If the performer is not the patient being tested, specify the person performing the test. | ||
value[x] | S | 0.. | CodeableConcept | At-Home Test Result Value |
specimen | S | 1.. | Reference (Specimen - At-Home In-Vitro Test) | The Specimen SHALL be from at-home sample. |
device | S | 1.. | Reference (Device - At-Home In-Vitro Test) | The referenced device SHALL be at-home test device. |
hasMember | Reference (Observation - At-Home In-Vitro Test Result) | Multiplex Assay tests that serve as a single test to diagnose infection caused by multiple viruses (e.g. CDC Flu SC2 Multiplex Assay for SARS-CoV-2, influenza A, and/or influenza B viruses) should be recorded using multiple Observation.hasMember elements. | ||
Documentation for this format |
Produced 06 Apr 2023