Source | hl7.fhir.us.codex-radiation-therapy#current:CodeX Radiation Therapy (v4.0.1) |
resourceType | StructureDefinition |
id | codexrt-radiotherapy-treatment-plan |
canonical | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-plan |
version | 1.0.0 |
status | draft |
publisher | HL7 Cross Group Projects Work Group |
name | RadiotherapyTreatmentPlan |
title | Radiotherapy Treatment Plan |
date | 2023-07-27T21:10:29+00:00 |
description | A Radiotherapy Treatment Plan resource describes the radiotherapy treatment that is planned to be delivered with a single treatment plan. |
jurisdictions | us |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | ServiceRequest |
derivation | constraint |
base | http://hl7.org/fhir/StructureDefinition/ServiceRequest |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
ServiceRequest | C | ServiceRequest |
codexrt-motion-management-none:
If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed.
They would also be 'none' or contradict the 'none'.
SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" |
|
Slices for extension | S | 1.. | Slice: Unordered, Open by value:url | |
modalityAndTechnique | S | 0..1 | (Complex) |
Radiotherapy Modality And Technique Extension
URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique |
radiotherapyEnergyOrIsotope | S | 0..* | Quantity |
Radiotherapy Energy or Isotope
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set ( required ) |
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept |
Radiotherapy Treatment Applicator Type
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set ( extensible ) |
imageGuidedRadiotherapyModality | S | 0..* | (Complex) |
Image Guided Radiotherapy Modality
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality |
radiotherapyFractionsPlanned | S | 1..1 | positiveInt |
Number of Planned Fractions
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-planned |
radiotherapyDosePlannedToVolume | S | 0..* | (Complex) |
Planned Dose to a Dose Reference
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-dose-planned-to-volume |
extension:fractions | .. 0 | |||
pointDose | S | 0..1 | boolean |
Point Dose
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
primaryPlanDose | S | 0..1 | boolean |
Primary Plan Dose
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
radiotherapyReasonForRevisionOrAdaptation | S | 0..* | CodeableConcept |
Reason for Revision or Adaptation
URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotheraphy-reason-for-revision-or-adaptation Binding: Radiotherapy Reason for Revision or Adaptation Value Set ( required ) |
respiratoryMotionManagement | S | 0..* | CodeableConcept |
Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set ( required ) |
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept |
Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set ( required ) |
radiotherapyDicomPlan | 0..1 | (Complex) |
DICOM Treatment Plan URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-dicom-reference |
|
Slices for identifier | S | 2 .. | Slice: Unordered, Open by value:use | |
identifier:displayName | S | 1..1 | The name that is displayed to the user. | |
use | 1.. | Required Pattern: usual | ||
system | S | 1.. | ||
value | S | 1.. | ||
identifier:official | S | 1..* |
A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
|
use | 1.. | Required Pattern: official | ||
system | S | 1.. | ||
value | S | 1.. | ||
Slices for basedOn | Slice: Unordered, Open by profile:$this.resolve() | |||
basedOn:plan-prescription | S | 0..1 | Reference (Radiotherapy Plan Prescription) | Radiotherapy Plan Prescription that this Treatment Plan fulfills. |
basedOn:planned-phase | S | 0..1 | Reference (Radiotherapy Planned Phase) | Radiotherapy Planned Phase that this Treatment Plan fulfills (in most cases together with other treatment plans). |
basedOn:planned-course | S | 0..1 | Reference (Radiotherapy Planned Course) | Radiotherapy Planned Course that this Treatment Plan fulfills (in most cases together with other treatment plans). |
replaces | S | Reference (Radiotherapy Treatment Plan) | Previous retired plan that is replaced by this plan | |
status | S | |||
intent | S | Required Pattern: filler-order | ||
Slices for category | S | 1 .. | Slice: Unordered, Open by pattern:$this | |
category:required | 1..1 | Required Pattern: At least the following | ||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://snomed.info/sct |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 108290001 |
|
display | 1..1 | string |
Representation defined by the system Fixed Value: Radiation oncology AND/OR radiotherapy |
|
doNotPerform | .. 0 | |||
code | S | 1.. | Required Pattern: At least the following | |
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://snomed.info/sct |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 1255724003 |
|
display | 1..1 | string |
Representation defined by the system Fixed Value: Radiotherapy treatment plan (regime/therapy) |
|
quantity[x] | .. 0 | |||
subject | S | Reference (US Core Patient Profile) | ||
asNeeded[x] | .. 0 | |||
requester | Reference (US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile) | |||
Slices for performer | S | Slice: Unordered, Open by profile:$this.resolve() | ||
performer:treatmentOrSeedDevice | S | 0..* | Reference (Radiotherapy Treatment Device | Radiotherapy Seed Device) |
Radiotherapy Treatment Device or Seed Device used as part of therapy. |
locationReference | S | Reference (US Core Location Profile) | ||
reasonCode | S | Binding: Cancer Disorder Value Set ( extensible ) | ||
reasonReference | S | Reference ( Condition ) | ||
specimen | .. 0 | |||
bodySite | S |
Body site that is treated with radiotherapy Binding: Radiotherapy Treatment Location Value Set ( required ) |
||
locationQualifier | 0..* | CodeableConcept |
General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set ( required ) |
|
lateralityQualifier | 0..1 | CodeableConcept |
Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set ( required ) |
|
Documentation for this format |
Produced 08 Sep 2023