Source | hl7.fhir.au.core#current:AU Core Implementation Guide (v4.0.1) |
resourceType | StructureDefinition |
id | au-core-diagnosticresult-imag |
canonical | http://hl7.org.au/fhir/core/StructureDefinition/au-core-diagnosticresult-imag |
version | 0.2.1 |
status | draft |
publisher | HL7 Australia |
name | AUCoreDiagnosticImagingResult |
title | AU Core Diagnostic Imaging Result Observation |
date | 2023-09-04T10:42:08+00:00 |
description | This profile sets minimum expectations for an Observation resource to record, search, and fetch diagnostic imaging results associated with a patient. It is based on the [AU Base Diagnostic Imaging Result](http://build.fhir.org/ig/hl7au/au-fhir-base/StructureDefinition-au-imagingresult.html) profile and identifies the *additional* mandatory core elements, extensions, vocabularies and value sets that **SHALL** be present in the Observation when conforming to this profile. It provides the floor for standards development for specific uses cases in an Australian context. |
copyright | Used by permission of HL7 International, all rights reserved Creative Commons License. HL7 Australia© 2022+; Licensed Under Creative Commons No Rights Reserved. |
jurisdictions | au |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org.au/fhir/StructureDefinition/au-imagingresult |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | AUBaseDiagnosticImagingResult | au-core-obs-05: If there is no component or hasMember element then at least value or data absent reason shall be present | |
identifier | S | |||
status | S |
preliminary | final | amended + Binding: todo ( required ) |
||
category | S | |||
code | S | |||
subject | S | Reference (AU Core Patient) | ||
effective[x] | S C |
Date, and optionally time, the imaging study was performed au-core-obs-01: Date shall be at least to day |
||
performer | S | Reference (AU Core Practitioner | AU Core PractitionerRole | AU Core Organization | AU Core Patient | AU Core RelatedPerson) | ||
value[x] | S C | |||
dataAbsentReason | S C | |||
interpretation | S | |||
note | S | |||
bodySite | S C | 1.. |
Binding:
todo
( extensible
) au-core-obs-04: If a coded body site is provided, at least one code shall be from SNOMED CT |
|
method | S | |||
referenceRange | S | |||
low | S | |||
high | S | |||
type | S | |||
text | S | |||
hasMember | S | Reference (AU Core Diagnostic Imaging Result Observation) | Individual observations in a group, study, or panel | |
reference | 1.. | |||
component | S C | au-core-obs-06: The component shall at least have a value or a data absent reason | ||
code | S | |||
value[x] | S C | |||
dataAbsentReason | S C | |||
Documentation for this format |
Produced 08 Sep 2023