Source | fhir.argonaut.r2#1.0.0:Argonaut Data Query Implementation Guide (v1.0.2) |
resourceType | StructureDefinition |
id | argo-vitalsigns |
canonical | http://fhir.org/guides/argonaut/StructureDefinition/argo-vitalsigns |
status | draft |
publisher | Argonaut Project |
name | Argonaut Vital Signs Observation Profile |
date | 2016-10-18T00:00:00+11:00 |
fhirVersion | 1.0.2 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/StructureDefinition/Observation |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0.. | Observation |
Argonaut Vital Signs Observation Profile arg-2: If there is no component or related element then either a value[x] or a data absent reason must be present |
status | S | 1..1 | code | Binding: Observation Status ( required ) |
category | S | 1..1 | CodeableConcept | Required Pattern: At least the following |
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://hl7.org/fhir/observation-category |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: vital-signs |
|
userSelected | 1..1 | boolean |
If this coding was chosen directly by the user Fixed Value: false |
|
code | S | 1..1 | CodeableConcept |
Coded Responses from C-CDA Vital Sign Results Binding: Argonaut Vital Sign Codes ( extensible ): This identifies the vital sign result type. |
subject | S | 1..1 | Reference (Argonaut Patient Profile) | |
effective[x] | S C | 1..1 |
Often just a dateTime for Vital Signs arg-1: Datetime must be at least to day. |
|
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
valueQuantity | S | 0..1 | Quantity |
Vital Sign Value recorded with UCUM Binding: Argonaut Vital Signs Units ( extensible ): Common UCUM units for recording Vital Signs |
value | S | 1..1 | decimal | |
unit | S | 1..1 | string | |
system | S | 1..1 | uri | Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. |
dataAbsentReason | S | 0..1 | CodeableConcept | Binding: todo ( extensible ) |
related | S | 0..* |
Used when reporting systolic and diastolic blood pressure. |
|
type | S | 1..1 | code | Fixed Value: has-member |
target | S | 1..1 | Reference (Argonaut Vital Signs Observation Profile) | |
component | S C | 0..* |
Used when reporting systolic and diastolic blood pressure. arg-3: If there is no a value a data absent reason must be present |
|
code | S | 1..1 | CodeableConcept |
Binding:
Argonaut Vital Sign Codes
( extensible
): This identifies the vital sign result type. |
valueQuantity | S | 0..1 | Quantity |
Vital Sign Value recorded with UCUM Binding: Argonaut Vital Signs Units ( extensible ): Common UCUM units for recording Vital Signs |
value | S | 1..1 | decimal | |
unit | S | 1..1 | string | |
system | S | 1..1 | uri | Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. |
dataAbsentReason | S | 0..1 | CodeableConcept | Binding: todo ( extensible ) |
Documentation for this format |