ServiceRequest (21)

#NameSourceVerDescription
1Course Involves Reirradiationhl7.fhir.us.codex-radiation-therapy#currentR4This flag is true if the radiotherapy course of treatment involves reirradiation of targets or organs at risk that were already irradiated in previous courses.
2Coverage Informationhl7.fhir.us.davinci-crd#currentR4Captures assertions from a payer about whether the service is covered and/or requires prior authorization.
3Dose Planned to Volumehl7.fhir.us.codex-radiation-therapy#currentR4Dose parameters planned for one radiotherapy volume.
4Dose Prescribed to Volumehl7.fhir.us.codex-radiation-therapy#currentR4Dose parameters prescribed for one radiotherapy volume.
5Eltss_directedByhl7.fhir.us.eltss#currentR4Indicates whether the individual chose to self-direct the service.
6Energy or Isotopehl7.fhir.us.codex-radiation-therapy#currentR4The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope.
7Free-Breathing Motion Management Techniquehl7.fhir.us.codex-radiation-therapy#currentR4Technique to manage respiratory motion with free-breathing.
8Image Guided Radiotherapy Modalityhl7.fhir.us.codex-radiation-therapy#currentR4The modality and associated energy used for imaging in Image Guided Radiotherapy (IGRT)
9Number of Delivered Fractionshl7.fhir.us.codex-radiation-therapy#currentR4The total number of fractions (treatment divisions) actually delivered for this volume.
10Number of Planned Fractionshl7.fhir.us.codex-radiation-therapy#currentR4The number of planned fractions in this scope. This extension SHALL only be present if the treatment is structured as countable fractions, for example in a Radiotherapy Planned Phase or in a Radiotherapy Treatment Plan.
11Number of Prescribed Fractionshl7.fhir.us.codex-radiation-therapy#currentR4The number of prescribed fractions in this scope. This extension SHALL only be present if the treatment is structured as countable fractions, for example in a Radiotherapy Phase Prescription.
12Point Dosehl7.fhir.us.codex-radiation-therapy#currentR4This flag is true if the dose is determined at a single point. Point doses are often used to check dose at a specific point in a calculated 3D dose distribution. Since point doses mostly have a technical role, high-level summaries may decide to exclude them from displays.
13Primary Plan Dosehl7.fhir.us.codex-radiation-therapy#currentR4This flag is true if the dose is the primary plan dose in a radiotherapy treatment plan. For a single treatment plan, the primary plan dose serves as the main dose value for tracking delivered dose vs. planned dose. In summaries over multiple treatment plans, the flag indicates that the dose is a primary plan dose in any of the summarized plans.
14QICore Appropriateness Scorehl7.fhir.us.qicore#currentR4The appropriateness score for the requested action.
15QICore IsElectivehl7.fhir.us.qicore#currentR4Indicates whether this is an elective procedure.
16Radiotherapy Volume Extensionhl7.fhir.us.codex-radiation-therapy#currentR4Extension providing a reference to a RadiotherapyVolume
17Reason for Revision or Adaptationhl7.fhir.us.codex-radiation-therapy#currentR4The reason a planned or prescribed radiotherapy treatment was revised, superceded, or adapted.
18Reference to DICOM SOP Instancehl7.fhir.us.codex-radiation-therapy#currentR4A reference to a DICOM SOP Instance.
19Respiratory Motion Managementhl7.fhir.us.codex-radiation-therapy#currentR4Method applied to manage respiratory motion.
20Treatment Applicator Typehl7.fhir.us.codex-radiation-therapy#currentR4Radiotherapy Treatment Applicator Type.
21Uniform Fractionationhl7.fhir.us.codex-radiation-therapy#currentR4This flag is true if the fractionation was uniform (i.e., treated with same modality and dose per fraction) and false if the fractionation was mixed. Treatment technique may vary in uniform fractionation. If the fractionation was uniform, then the correspondence between the physical and biologically effective dose can be determined at the course level. If the fractionation was not uniform, then the correspondence between the physical and biologically effective dose has to be determined per the phase level. The flag was introduced to support determination of whether fractionation was uniform when viewing the Radiotherapy Course Summary (without first checking the details of each treatment phase). This is important in registry use cases to efficiently assess whether checking phase level information is needed.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Extension C D I D D D D D D I D C D C D C D C D C D C D C D D D D D D C D
Extension.extension C S C D (17) S C D (5) S C D (5) C C C S C (3) C C C C C S C C C S C D (3) C C C
Extension.extension.value[x] C D B M (16) C F (4) C F (4) B M (2) C (2)
Extension.extension.url F (16) F (4) F (4) F (2) F (2)
Extension.extension.extension S C D (19) C (4) C (4) C (2) C (2)
Extension.extension.extension.value[x] B M (3)
Extension.extension.extension.url F (3)
Extension.extension.extension.extension C (3)
Extension.url F F F F F F F F F F F F F F F F F F F F F
Extension.value[x] C C C S C B M (3) C B M C C C C C B M C C B M C C B M B M
Extension.value[x].code C
Extension.value[x].system C
Extension.value[x].value C
S: There is slicing defined in the element(s)
C: There is cardinality erstrictions defined in the element(s)
I: There is invariants defined in the element(s)
F: There is a fixed or pattern value defined in the element(s)
D: There is document provided in the element(s)
B: There is terminology bindings defined in the element(s)
M: At least one of the element(s) has must-support = true
(N): The number of elements if > 1

Produced 08 Sep 2023