Source | hl7.fhir.uv.phd#current:Personal Health Device Implementation Guide (v4.0.1) |
resourceType | StructureDefinition |
id | PhdRtsaObservation |
canonical | http://hl7.org/fhir/uv/phd/StructureDefinition/PhdRtsaObservation |
version | 1.0.0 |
status | draft |
publisher | HL7 International - Health Care Devices Work Group |
name | PhdRtsaObservation |
date | 2017-06-02T14:29:52.39367-04:00 |
description | StructureDefinition for Observation Resources representing measurement data coming from a medical device where the measurement is a waveform. |
jurisdictions | uv |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBaseObservation |
Usages | (none) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | PhdBaseObservation | |||
meta | 1.. | |||
Slices for profile | 1 .. | Slice: Unordered, Open by value:value | ||
profile:phdProfile | 1..1 | Fixed Value: http://hl7.org/fhir/uv/phd/StructureDefinition/PhdRtsaObservation | ||
category:vitalSignsCategory | Required by the FHIR specification if the measurement value is a vital sign | |||
Slices for coding | 1 .. | Slice: Unordered, Open by value:system | ||
coding:vitalSigns | 1..1 | Required Vital Signs category code system entry | ||
system | 1.. | Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||
code | 1.. | Fixed Value: vital-signs | ||
valueSampledData | SampledData | |||
origin | 1.. | Scaling intecept value and units | ||
value | 1.. | Intercept value (with implicit precision) | ||
system | 1.. |
The UCUM coding system Fixed Value: http://unitsofmeasure.org |
||
code | 1.. | |||
factor | 1.. | The scale factor | ||
dimensions | Number of rtsa sample points at each time point | |||
data | ||||
dataAbsentReason | Populated when the Measurement-Status indicates invalid, not unavailable, or msmt ongoing | |||
Slices for coding | 1 .. | Slice: Unordered, Open by value:system | ||
coding:FhirDefault | 1..1 | |||
system | 1.. | Fixed Value: http://terminology.hl7.org/CodeSystem/data-absent-reason | ||
code | 1.. | |||
Slices for referenceRange | Slice: Unordered, Open by value:low.system | |||
referenceRange:scaleAndReferenceRange | ..1 | Provides the scale factors as sent by the 20601 device | ||
low | 1.. | |||
value | 1.. | |||
system | 1.. | Fixed Value: http://unitsofmeasure.org | ||
code | 1.. | |||
high | 1.. | |||
value | 1.. | |||
system | 1.. | Fixed Value: http://unitsofmeasure.org | ||
code | 1.. | |||
Documentation for this format |
Produced 06 Apr 2023