StructureDefinition-PhdRtsaObservation

Sourcehl7.fhir.uv.phd#current:Personal Health Device Implementation Guide (v4.0.1)
resourceTypeStructureDefinition
idPhdRtsaObservation
canonicalhttp://hl7.org/fhir/uv/phd/StructureDefinition/PhdRtsaObservation
version1.0.0
statusdraft
publisherHL7 International - Health Care Devices Work Group
namePhdRtsaObservation
date2017-06-02T14:29:52.39367-04:00
descriptionStructureDefinition for Observation Resources representing measurement data coming from a medical device where the measurement is a waveform.
jurisdictionsuv
fhirVersion4.0.1
kindresource
abstractfalse
sdTtypeObservation
derivationconstraint
basehttp://hl7.org/fhir/uv/phd/StructureDefinition/PhdBaseObservation
Usages(none)
Name Flags Card. Type Description & Constraints doco
. . Observation PhdBaseObservation
. . . meta 1..
. . . . Slices for profile 1 .. Slice: Unordered, Open by value:value
. . . . . profile:phdProfile 1..1 Fixed Value: http://hl7.org/fhir/uv/phd/StructureDefinition/PhdRtsaObservation
. . . category:vitalSignsCategory Required by the FHIR specification if the measurement value is a vital sign
. . . . Slices for coding 1 .. Slice: Unordered, Open by value:system
. . . . . coding:vitalSigns 1..1 Required Vital Signs category code system entry
. . . . . . system 1.. Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
. . . . . . code 1.. Fixed Value: vital-signs
. . . valueSampledData SampledData
. . . . origin 1.. Scaling intecept value and units
. . . . . value 1.. Intercept value (with implicit precision)
. . . . . system 1.. The UCUM coding system
Fixed Value: http://unitsofmeasure.org
. . . . . code 1..
. . . . factor 1.. The scale factor
. . . . dimensions Number of rtsa sample points at each time point
. . . . data
. . . dataAbsentReason Populated when the Measurement-Status indicates invalid, not unavailable, or msmt ongoing
. . . . Slices for coding 1 .. Slice: Unordered, Open by value:system
. . . . . coding:FhirDefault 1..1
. . . . . . system 1.. Fixed Value: http://terminology.hl7.org/CodeSystem/data-absent-reason
. . . . . . code 1..
. . . Slices for referenceRange Slice: Unordered, Open by value:low.system
. . . . referenceRange:scaleAndReferenceRange ..1 Provides the scale factors as sent by the 20601 device
. . . . . low 1..
. . . . . . value 1..
. . . . . . system 1.. Fixed Value: http://unitsofmeasure.org
. . . . . . code 1..
. . . . . high 1..
. . . . . . value 1..
. . . . . . system 1.. Fixed Value: http://unitsofmeasure.org
. . . . . . code 1..

doco Documentation for this format

Produced 06 Apr 2023