Source | hl7.fhir.us.qicore#current:QI-Core Implementation Guide (v4.0.1) |
resourceType | StructureDefinition |
id | qicore-devicenotrequested |
canonical | http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-devicenotrequested |
version | 6.0.0-ballot |
status | active |
publisher | http://www.hl7.org/Special/committees/cqi/index.cfm |
name | QICoreDeviceNotRequested |
title | QICore Device Not Requested |
date | 2019-07-11 |
experimental | false |
description | Profile of DeviceRequest for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors. |
jurisdictions | us |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | DeviceRequest |
derivation | constraint |
base | http://hl7.org/fhir/StructureDefinition/DeviceRequest |
Usages | (none) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceRequest | C | DeviceRequest | dnr-1: to indicate what device was not requested, either at least one coding in the code or a notDoneValueSet extension shall be provided | |
doNotPerformReason | S | 1..1 | CodeableConcept |
Extension
URL: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-doNotPerformReason Binding: QICore Negation Reason Codes ( extensible ): The reason the event did not occur or was not performed |
modifierExtension:doNotPerform | ?! S | 1..1 | Extension | |
value[x] | S | 1..1 | boolean | Fixed Value: true |
status | S | |||
intent | S | |||
code[x] | S C | 1..1 | CodeableConcept | Binding: todo ( preferred ) |
doNotPerformValueSet | S C | 0..1 | canonical ( ValueSet ) |
What was not done URL: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-notDoneValueSet |
subject | S | Reference (QICore Patient) | ||
authoredOn | S | 1..1 | ||
Documentation for this format |
Produced 08 Sep 2023