StructureDefinition-pacio-fsc

Sourcehl7.fhir.us.pacio-fs#current:PACIO Functional Status Implementation Guide (v4.0.1)
resourceTypeStructureDefinition
idpacio-fsc
canonicalhttp://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fsc
version1.0.0
statusactive
publisherHL7 Patient Care Work Group
nameFunctionalStatusCollection
titlePACIO Functional Status Collection
date2021-11-03T18:56:23+00:00
descriptionA point in time collection of functional status observations for a patient. This profile is used for exchanging a set of observation data collected through the use of a structured resource (e.g. assessment tool, instrument, or screen).
jurisdictionsus
fhirVersion4.0.1
kindresource
abstractfalse
sdTtypeObservation
derivationconstraint
basehttp://hl7.org/fhir/StructureDefinition/Observation
Usages(none)
Name Flags Card. Type Description & Constraints doco
. . Observation Observation
. . . Slices for extension Slice: Unordered, Open by value:url
. . . event-location S 0..1 Reference (US Core Location Profile) An extension to indicate where the observation event occurred.
URL: http://hl7.org/fhir/us/pacio-fs/StructureDefinition/event-location
. . . device-use S 0..* Reference (Use of Device) An extension to indicate a record of assistive device usage by a patient during an assessment.
URL: http://hl7.org/fhir/us/pacio-fs/StructureDefinition/device-patient-used
. . . basedOn Currently not used in FunctionalStatusCollection.
. . . partOf Currently not used in FunctionalStatusCollection.
. . . status Should have the value 'final' when all the observatons are complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.
. . . Slices for category 1 .. A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.
Slice: Unordered, Open by pattern:coding
. . . . category:functioning 1..1 Binding: PACIO Functioning Category Value Set ( extensible )
. . . . . coding 1.. Required Pattern: At least the following
. . . . . . system 1..1 uri Identity of the terminology system
Fixed Value: http://hl7.org/fhir/us/pacio-fs/CodeSystem/pacio-cat-fs
. . . . . . code 1..1 code Symbol in syntax defined by the system
Fixed Value: functioning
. . . . . . display 1..1 string Representation defined by the system
Fixed Value: Functioning
. . . code For a Post-Acute Care structured assessment resource such as an instrument or screen, use a LOINC code to identify the instrument/screen name or panel/section title to indicate the kind of assessment.
Binding: LOINC Codes ( extensible )
. . . subject 1.. Reference (US Core Patient Profile) Should only reference a Patient resource.
. . . focus Currently not used in FunctionalStatusCollection.
. . . encounter Reference (US Core Encounter Profile)
. . . effective[x] 1.. Clinical relevant time for an assessment such as functional assessments performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).
. . . . effectiveDateTime dateTime
. . . . effectivePeriod Period
. . . issued Currently not used in FunctionalStatusCollection.
. . . performer 1.. Reference (US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile) The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.
. . . value[x] If used, should use the CodeableConcept datatype whenever possible to provide a suitable code to define the concept for the observation data. When capturing a collection of related observations, typically this field is not used. If the outcome of an assessment includes one or more summary scores, leave this field unused and use the 'hasMember' field to point to one or more Observation resources with each of which has a score provided in the 'value' field.
. . . dataAbsentReason Currently not used in FunctionalStatusCollection.
. . . interpretation Currently not used in FunctionalStatusCollection.
. . . bodySite Currently not used in FunctionalStatusCollection.
. . . method Currently not used in FunctionalStatusCollection.
. . . specimen Currently not used in FunctionalStatusCollection.
. . . device Currently not used in FunctionalStatusCollection.
. . . referenceRange Currently not used in FunctionalStatusCollection.
. . . hasMember S Reference (PACIO Functional Status) Each functional status observation in the collection.
. . . derivedFrom S Reference (SDC Questionnaire Response) Should point back to the SDC QuestionnaireResponse that this resource is derived from.
. . . component Currently not used in FunctionalStatusCollection.

doco Documentation for this format

Produced 06 Apr 2023