Source | hl7.fhir.us.cardx-htn#current:CardX Hypertension Management Use Case (v4.0.1) |
resourceType | StructureDefinition |
id | blood-pressure-panel |
canonical | http://hl7.org/fhir/us/cardx-htn/StructureDefinition/blood-pressure-panel |
version | 0.1.0 |
status | draft |
publisher | Clinical Interoperability Council |
name | BloodPressurePanel |
title | Blood Pressure Panel |
date | 2023-08-03T21:36:59+00:00 |
description | Blood Pressure Panel; a grouping of systolic and diastolic blood pressure components. |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/StructureDefinition/Observation |
Usages | (none) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | Observation | |||
Slices for extension | Slice: Unordered, Open by value:url | |||
bodyPosition | S | 0..1 | CodeableConcept |
Body Position URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
value[x] | Binding: Body Position value set ( extensible ) | |||
sleepStatus | S | 0..1 | CodeableConcept |
Sleep Status URL: http://hl7.org/fhir/us/cardx-htn/StructureDefinition/SleepStatusExt Binding: Sleep Status value set ( extensible ) |
exerciseAssociation | S | 0..1 | CodeableConcept |
Exercise Association URL: http://hl7.org/fhir/us/cardx-htn/StructureDefinition/ExerciseAssociationExt Binding: Exertion Phase value set ( extensible ) |
MeasurementSetting | S | 0..1 | CodeableConcept |
Measurement setting URL: http://hl7.org/fhir/us/cardx-htn/StructureDefinition/MeasurementSettingExt Binding: Measurement Setting value set ( extensible ) |
status | S | |||
code |
Blood pressure panel with all children optional Required Pattern: At least the following |
|||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://loinc.org |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 85354-9 |
|
subject | S | 1.. | Reference ( Patient ) | |
effective[x] | S | 1.. | ||
value[x] | .. 0 | |||
interpretation | ..1 | Binding: Numeric Result Interpretation value set ( extensible ) | ||
bodySite | S |
Binding:
Blood Pressure Measurement Body Location Precoordinated value set
( extensible
): A set of codes that describe where on/in the body an observation or procedure took place |
||
method | S |
Binding:
Blood Pressure Measurement Method value set
( extensible
): A set of codes that describe the method used to measure a blood pressure |
||
specimen | .. 0 | |||
device | S | Blood Pressure Device | ||
Slices for component | S | 2 .. |
Blood pressure components
Slice: Unordered, Open by value:code |
|
component:SystolicBP | 1..1 | Systolic Blood Pressure | ||
code | S |
Systolic blood pressure Required Pattern: At least the following |
||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://loinc.org |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 8480-6 |
|
value[x] | S | Quantity | ||
value | S | 1.. | ||
unit | S | 1.. | ||
system | S | 1.. | Fixed Value: http://unitsofmeasure.org | |
code | S | 1.. | Fixed Value: mm[Hg] | |
component:DiastolicBP | 1..1 | Diastolic Blood Pressure | ||
code | S |
Diastolic blood pressure Required Pattern: At least the following |
||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://loinc.org |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 8462-4 |
|
value[x] | S | Quantity | ||
value | S | 1.. | ||
unit | S | 1.. | ||
system | S | 1.. | Fixed Value: http://unitsofmeasure.org | |
code | S | 1.. | Fixed Value: mm[Hg] | |
Documentation for this format |
Produced 08 Sep 2023