Source | hl7.fhir.us.breastcancer#0.2.0:null (v3.0.2) |
resourceType | StructureDefinition |
id | oncology-MammaprintRecurrenceScore |
canonical | http://hl7.org/fhir/us/breastcancer/StructureDefinition/oncology-MammaprintRecurrenceScore |
version | 0.2.0 |
status | draft |
publisher | The HL7 Cancer Interoperability Group sponsored by Clinical Interoperability Council Work Group (CIC) |
name | MammaprintRecurrenceScoreProfile |
title | BC MammaprintRecurrenceScore Profile |
date | 2018-08-17T00:00:00+10:00 |
description | Breast cancer genomic signature assay for 10-year risk of distant recurrence score calculated by Mammaprint. In the United States, MammaPrint can only be used on cancers that are stage I or stage II, invasive, smaller than 5 centimeters, and estrogen-receptor-positive or -negative. Scores range from -1.0 to +1.0, with scores less than 0 indicating high risk, and scores greater than 0 indicating low risk. The is currently no LOINC code for Mammaprint test. |
jurisdictions | us |
fhirVersion | 3.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/us/core/StructureDefinition/us-core-observationresults |
Usages | (none) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | BC MammaprintRecurrenceScore Profile | |||
deltaflag | 0..1 | CodeableConcept |
Qualitative change or trend in the measurement
URL: http://hl7.org/fhir/StructureDefinition/observation-delta |
|
category | ||||
Slices for coding | 1 .. * |
Slice:
Unordered, Open by value:code
|
||
coding:Fixed_laboratory | Σ | 1..1 | Coding | |
system | Fixed Value: http://hl7.org/fhir/observation-category | |||
code | Fixed Value: laboratory | |||
code | ||||
Slices for coding | 1 .. * |
Slice:
Unordered, Open by value:code
|
||
coding:Fixed_C2827401 | Σ | 1..1 | Coding | MammaPrint |
system | Fixed Value: http://ncimeta.nci.nih.gov | |||
code | Fixed Value: C2827401 | |||
valueQuantity | Quantity | |||
dataAbsentReason | Binding: Data Absent Reason ( extensible ) | |||
interpretation | Binding: BC RecurrenceRiskScoreInterpretationVS ValueSet ( required ) | |||
bodySite | 0 .. 0 | |||
method | Binding: todo ( preferred ) | |||
specimen | 1..1 | Reference (BC BreastSpecimen Profile) | ||
device | 0 .. 0 | |||
referenceRange | ||||
appliesTo |
Binding:
Observation Reference Range Applies To Codes
( extensible
): Codes identifying the population the reference range applies to. |
|||
related | 0 .. 0 | |||
component | 0 .. 0 | |||
Documentation for this format |
Produced 06 Apr 2023