Source | hl7.fhir.mi.base#current:MI Base (v4.0.1) |
resourceType | StructureDefinition |
id | MIBaseRespiratoryRateProfile |
canonical | http://iop.ezcaretech.com/fhir/mi/base/StructureDefinition/MIBaseRespiratoryRateProfile |
version | 0.1.0 |
status | draft |
publisher | MKJ |
name | MIBaseRespiratoryRateProfile |
title | MIBaseRespiratoryRateProfile |
date | 2023-08-09T08:51:01+00:00 |
description | MI Base RespiratoryRate Profile |
jurisdictions | kr |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://iop.ezcaretech.com/fhir/mi/base/StructureDefinition/MIBaseVitalSignsProfile |
Usages | (none) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | MIBaseVitalSignsProfile | |||
code |
호흡수 측정 코드 Required Pattern: At least the following |
|||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://loinc.org |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 9279-1 |
|
Slices for value[x] | Slice: Unordered, Open by type:$this | |||
value[x]:valueQuantity | S | 0..1 | Quantity | 호흡수 측정 결과 |
value | S | 1.. | 측정값(숫자) | |
unit | 측정 단위 텍스트 | |||
system | S | 1.. |
측정 단위 코드체계 식별자 Fixed Value: http://unitsofmeasure.org |
|
code | S | 1.. |
측정 단위 코드값 Fixed Value: /min |
|
Documentation for this format |
Produced 08 Sep 2023