StructureDefinition-2.16.840.1.113883.10.20.22.4.2

Sourcehl7.cda.us.ccdar2dot2#current:Consolidated CDA Release 2.1 StructureDefinition Publication (v5.0.0)
resourceTypeStructureDefinition
id2.16.840.1.113883.10.20.22.4.2
canonicalhttp://hl7.org/fhir/cda/ccda/StructureDefinition/2.16.840.1.113883.10.20.22.4.2
version2.2
statusactive
publisherHealth Level Seven
nameResultObservation
titleResult Observation
date2021-11-24T17:43:01+00:00
descriptionThis template represents the results of a laboratory, radiology, or other study performed on a patient. The result observation includes a statusCode to allow recording the status of an observation. Pending results (e.g., a test has been run but results have not been reported yet) should be represented as active ActStatus.
jurisdictionsus
fhirVersion4.0.1
kindresource
abstractfalse
sdTtypeObservation
derivationconstraint
basehttp://hl7.org/fhir/cda/StructureDefinition/Observation
Usages
Name Flags Card. Type Description & Constraints doco
. . Observation
. . . classCode 1..1 Required Pattern: OBS
. . . moodCode 1..1 Required Pattern: EVN
. . . Slices for templateId Slice: Unordered, Open by value:extension, value:root
. . . . templateId:primary 1..1
. . . . . root 1..1 Required Pattern: 2.16.840.1.113883.10.20.22.4.2
. . . . . extension 1..1 Required Pattern: 2015-08-01
. . . id 1..*
. . . code C 1..1 1198-19212: This code **SHOULD** be a code from the LOINC that identifies the result observation. If an appropriate LOINC code does not exist, then the local code for this result **SHALL** be sent (CONF:1198-19212).
. . . statusCode 1..1
. . . . code 1..1 Binding: Result Status ( required )
. . . effectiveTime 1..1 Represents the biologically relevant time of the measurement (e.g., the time a blood pressure reading is obtained, the time the blood sample was obtained for a chemistry test).
. . . value C 1..1 1198-32610: If Observation/value is a CD (**xsi:type="CD"**) the value **SHOULD** be SNOMED-CT (CONF:1198-32610).
1198-31866: A coded or physical quantity value **MAY** contain zero or more [0..*] translations, which can be used to represent the original results as output by the lab (CONF:1198-31866).
1198-31484: If Observation/value is a physical quantity (**xsi:type="PQ"**), the unit of measure **SHALL** be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 **DYNAMIC** (CONF:1198-31484).
. . . interpretationCode 0..*
. . . . code 1..1 Binding: Observation Interpretation (HL7) ( required )
. . . methodCode 0..1
. . . targetSiteCode 0..1
. . . author 0..* http://hl7.org/fhir/cda/StructureDefinition/Author
. . . referenceRange 0..*
. . . . observationRange 1..1
. . . . . code 0 .. 0
. . . . . value 1..1

doco Documentation for this format

Produced 08 Sep 2023