Source | hl7.cda.us.ccdar2dot2#current:Consolidated CDA Release 2.1 StructureDefinition Publication (v5.0.0) |
resourceType | StructureDefinition |
id | 2.16.840.1.113883.10.20.22.4.2 |
canonical | http://hl7.org/fhir/cda/ccda/StructureDefinition/2.16.840.1.113883.10.20.22.4.2 |
version | 2.2 |
status | active |
publisher | Health Level Seven |
name | ResultObservation |
title | Result Observation |
date | 2021-11-24T17:43:01+00:00 |
description | This template represents the results of a laboratory, radiology, or other study performed on a patient. The result observation includes a statusCode to allow recording the status of an observation. Pending results (e.g., a test has been run but results have not been reported yet) should be represented as active ActStatus. |
jurisdictions | us |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/cda/StructureDefinition/Observation |
Usages |
|
Name | Flags | Card. | Type |
Description & Constraints
![]() |
---|---|---|---|---|
![]() ![]() |
||||
![]() ![]() ![]() |
1..1 | Required Pattern: OBS | ||
![]() ![]() ![]() |
1..1 | Required Pattern: EVN | ||
![]() ![]() ![]() |
Slice: Unordered, Open by value:extension, value:root | |||
![]() ![]() ![]() ![]() |
1..1 | |||
![]() ![]() ![]() ![]() ![]() |
1..1 | Required Pattern: 2.16.840.1.113883.10.20.22.4.2 | ||
![]() ![]() ![]() ![]() ![]() |
1..1 | Required Pattern: 2015-08-01 | ||
![]() ![]() ![]() |
1..* | |||
![]() ![]() ![]() |
C | 1..1 | 1198-19212: This code **SHOULD** be a code from the LOINC that identifies the result observation. If an appropriate LOINC code does not exist, then the local code for this result **SHALL** be sent (CONF:1198-19212). | |
![]() ![]() ![]() |
1..1 | |||
![]() ![]() ![]() ![]() |
1..1 | Binding: Result Status ( required ) | ||
![]() ![]() ![]() |
1..1 | Represents the biologically relevant time of the measurement (e.g., the time a blood pressure reading is obtained, the time the blood sample was obtained for a chemistry test). | ||
![]() ![]() ![]() |
C | 1..1 |
1198-32610:
If Observation/value is a CD (**xsi:type="CD"**) the value **SHOULD** be SNOMED-CT (CONF:1198-32610). 1198-31866: A coded or physical quantity value **MAY** contain zero or more [0..*] translations, which can be used to represent the original results as output by the lab (CONF:1198-31866). 1198-31484: If Observation/value is a physical quantity (**xsi:type="PQ"**), the unit of measure **SHALL** be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 **DYNAMIC** (CONF:1198-31484). |
|
![]() ![]() ![]() |
0..* | |||
![]() ![]() ![]() ![]() |
1..1 | Binding: Observation Interpretation (HL7) ( required ) | ||
![]() ![]() ![]() |
0..1 | |||
![]() ![]() ![]() |
0..1 | |||
![]() ![]() ![]() |
0..* | http://hl7.org/fhir/cda/StructureDefinition/Author | ||
![]() ![]() ![]() |
0..* | |||
![]() ![]() ![]() ![]() |
1..1 | |||
![]() ![]() ![]() ![]() ![]() |
0 .. 0 | |||
![]() ![]() ![]() ![]() ![]() |
1..1 | |||
![]() |
Produced 08 Sep 2023