StructureDefinition-2.16.840.1.113883.10.20.22.4.2

Sourcehl7.cda.us.ccda#current:Consolidated CDA Release 2.1 StructureDefinition Publication (v5.0.0)
resourceTypeStructureDefinition
id2.16.840.1.113883.10.20.22.4.2
canonicalhttp://hl7.org/cda/us/ccda/StructureDefinition/2.16.840.1.113883.10.20.22.4.2
version2.1
statusdraft
publisherHealth Level Seven
nameResultObservationV4
titleResult Observation (V4)
date2023-08-24T14:33:15+00:00
descriptionThis template represents the results of a laboratory, radiology, or other study performed on a patient. The result observation includes a statusCode to allow recording the status of an observation. Pending results (e.g., a test has been run but results have not been reported yet) should be represented as active ActStatus.
jurisdictionsus
fhirVersion5.0.0
kindlogical
abstractfalse
sdTtypehttp://hl7.org/cda/stds/core/StructureDefinition/Observation
derivationconstraint
basehttp://hl7.org/cda/stds/core/StructureDefinition/Observation
Usages
Name Flags Card. Type Description & Constraints doco
. . Observation CDAR2.Observation XML Namespace: urn:hl7-org:v3
This logical model cannot be the target of a reference
. . . classCode 1..1 classCode
Fixed Value: OBS
. . . moodCode 1..1 moodCode
Fixed Value: EVN
. . . Slices for templateId 1 .. Slice: Unordered, Open by value:root, value:extension
. . . . templateId:templateId1 1..1 templateId
. . . . . root 1..1 root
Required Pattern: 2.16.840.1.113883.10.20.22.4.2
. . . . . extension 1..1 extension
Required Pattern: 2023-05-01
. . . id 1..* id
. . . code C 1..1 code
4537-19212: This code **SHOULD** be a code from the LOINC that identifies the result observation. If an appropriate LOINC code does not exist, then the local code for this result **SHALL** be sent (CONF:4537-19212).
. . . statusCode 1..1 statusCode
. . . . code 1..1 code
Binding: Result Status ( required )
. . . effectiveTime 1..1 Represents the clinically relevant time of the measurement (e.g., the time a blood pressure reading is obtained, the time the blood sample was obtained for a chemistry test).
. . . value C 1..1 value
4537-31484: If Observation/value is a physical quantity (**xsi:type="PQ"**), the unit of measure **SHOULD** be selected from ValueSet **UnitsOfMeasureCaseSensitive urn:oid:2.16.840.1.113883.1.11.12839 DYNAMIC** (CONF:4537-31484).
4537-31866: A coded or physical quantity value **MAY** contain zero or more [0..*] translations, which can be used to represent the original results as output by the lab (CONF:4537-31866).
4537-32610: If Observation/value is a CD (**xsi:type="CD"**) the value **SHOULD** be SNOMED-CT (CONF:4537-32610).
. . . interpretationCode 0..* interpretationCode
Binding: Observation Interpretation (HL7) ( required )
. . . methodCode 0..1 methodCode
. . . targetSiteCode 0..1 targetSiteCode
. . . specimen 0..* specimen
. . . . specimenRole 1..1 specimenRole
. . . . . specimenPlayingEntity 1..1 specimenPlayingEntity
. . . . . . code 1..1 code
Binding: Specimen type ( preferred )
. . . author 0..* http://hl7.org/cda/stds/core/StructureDefinition/Author author
. . . referenceRange 0..* referenceRange
. . . . observationRange 1..1 observationRange
. . . . . code 0 .. 0
. . . . . value 1..1 value

doco Documentation for this format