Source | hl7.cda.us.ccda#current:Consolidated CDA Release 2.1 StructureDefinition Publication (v5.0.0) |
resourceType | StructureDefinition |
id | 2.16.840.1.113883.10.20.22.4.135 |
canonical | http://hl7.org/cda/us/ccda/StructureDefinition/2.16.840.1.113883.10.20.22.4.135 |
version | 2.1 |
status | active |
publisher | Health Level Seven |
name | MedicalEquipmentOrganizer |
title | Medical Equipment Organizer |
date | 2023-08-24T14:33:15+00:00 |
description | This template represents a set of current or historical medical devices, supplies, aids and equipment used by the patient. Examples are hearing aids, orthotic devices, ostomy supplies, visual aids, diabetic supplies such as syringes and pumps, and wheelchairs. Devices that are applied during a procedure (e.g., cardiac pacemaker, gastrosomy tube, port catheter), whether permanent or temporary, are represented within the Procedure Activity Procedure (V2) template (templateId: 2.16.840.1.113883.10.20.22.4.14.2). |
jurisdictions | us |
fhirVersion | 5.0.0 |
kind | logical |
abstract | false |
sdTtype | http://hl7.org/cda/stds/core/StructureDefinition/Organizer |
derivation | constraint |
base | http://hl7.org/cda/stds/core/StructureDefinition/Organizer |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Organizer | C | CDAR2.Organizer |
XML Namespace:
urn:hl7-org:v3 This logical model cannot be the target of a reference 1098-32380: Either Non-Medicinal Supply Activity (V2) (templateId:2.16.840.1.113883.10.20.22.4.50:2014-06-09) **OR** Procedure Activity Procedure (V2) (templateId:2.16.840.1.113883.10.20.22.4.14:2014-06-09) **SHALL** be present (CONF:1098-32380). |
|
classCode | 1..1 | Fixed Value: CLUSTER | ||
moodCode | 1..1 | |||
Slices for templateId | 1 .. | Slice: Unordered, Open by value:root | ||
templateId:primary | 1..1 | |||
root | 1..1 | Required Pattern: 2.16.840.1.113883.10.20.22.4.135 | ||
id | 1..* | |||
code | 0..1 | This code can represent a category of devices. The code is strictly optional, and is not currently limited to any value set or code system. Implementers may use it if they wish to provide optional coded information about this grouping of medical equipment. | ||
statusCode | 1..1 | The organizer is a collection of statuses for contained entries. The organizer remains active until all contained entries are done. | ||
code | 1..1 | Binding: Result Status ( required ) | ||
effectiveTime | 1..1 | The effectiveTime can be used to show the time period over which the patient will be using the set of equipment. The organizer would probably not be used with devices applied in or on the patient. | ||
low | 1..1 | |||
high | 1..1 | |||
Slices for component | Slice: Unordered, Open by profile:supply, profile:procedure | |||
component:nonMedicalSupply | 0..* | |||
supply | 1..1 | http://hl7.org/cda/stds/core/StructureDefinition/Supply | ||
component:procedureActivity | 0..* | |||
supply | 1..1 | http://hl7.org/cda/stds/core/StructureDefinition/Procedure | ||
Documentation for this format |