StructureDefinition-2.16.840.1.113883.10.20.22.4.135

Sourcehl7.cda.us.ccda#current:Consolidated CDA Release 2.1 StructureDefinition Publication (v5.0.0)
resourceTypeStructureDefinition
id2.16.840.1.113883.10.20.22.4.135
canonicalhttp://hl7.org/cda/us/ccda/StructureDefinition/2.16.840.1.113883.10.20.22.4.135
version2.1
statusactive
publisherHealth Level Seven
nameMedicalEquipmentOrganizer
titleMedical Equipment Organizer
date2023-08-24T14:33:15+00:00
descriptionThis template represents a set of current or historical medical devices, supplies, aids and equipment used by the patient. Examples are hearing aids, orthotic devices, ostomy supplies, visual aids, diabetic supplies such as syringes and pumps, and wheelchairs. Devices that are applied during a procedure (e.g., cardiac pacemaker, gastrosomy tube, port catheter), whether permanent or temporary, are represented within the Procedure Activity Procedure (V2) template (templateId: 2.16.840.1.113883.10.20.22.4.14.2).
jurisdictionsus
fhirVersion5.0.0
kindlogical
abstractfalse
sdTtypehttp://hl7.org/cda/stds/core/StructureDefinition/Organizer
derivationconstraint
basehttp://hl7.org/cda/stds/core/StructureDefinition/Organizer
Usages
Name Flags Card. Type Description & Constraints doco
. . Organizer C CDAR2.Organizer XML Namespace: urn:hl7-org:v3
This logical model cannot be the target of a reference
1098-32380: Either Non-Medicinal Supply Activity (V2) (templateId:2.16.840.1.113883.10.20.22.4.50:2014-06-09) **OR** Procedure Activity Procedure (V2) (templateId:2.16.840.1.113883.10.20.22.4.14:2014-06-09) **SHALL** be present (CONF:1098-32380).
. . . classCode 1..1 Fixed Value: CLUSTER
. . . moodCode 1..1
. . . Slices for templateId 1 .. Slice: Unordered, Open by value:root
. . . . templateId:primary 1..1
. . . . . root 1..1 Required Pattern: 2.16.840.1.113883.10.20.22.4.135
. . . id 1..*
. . . code 0..1 This code can represent a category of devices. The code is strictly optional, and is not currently limited to any value set or code system. Implementers may use it if they wish to provide optional coded information about this grouping of medical equipment.
. . . statusCode 1..1 The organizer is a collection of statuses for contained entries. The organizer remains active until all contained entries are done.
. . . . code 1..1 Binding: Result Status ( required )
. . . effectiveTime 1..1 The effectiveTime can be used to show the time period over which the patient will be using the set of equipment. The organizer would probably not be used with devices applied in or on the patient.
. . . . low 1..1
. . . . high 1..1
. . . Slices for component Slice: Unordered, Open by profile:supply, profile:procedure
. . . . component:nonMedicalSupply 0..*
. . . . . supply 1..1 http://hl7.org/cda/stds/core/StructureDefinition/Supply
. . . . component:procedureActivity 0..*
. . . . . supply 1..1 http://hl7.org/cda/stds/core/StructureDefinition/Procedure

doco Documentation for this format

Produced 08 Sep 2023