Source | ch.fhir.ig.ch-crl#0.9.0:CH CRL (R4) (v4.0.1) |
resourceType | StructureDefinition |
id | ch-crl-observation-resectionmargininvasivetumour |
canonical | http://fhir.ch/ig/ch-crl/StructureDefinition/ch-crl-observation-resectionmargininvasivetumour |
version | 0.9.0 |
status | active |
publisher | Bundesamt für Gesundheit BAG |
name | CHCRLObservationResectionMarginInvasiveTumour |
title | CH CRL Observation Resection Margin Invasive Tumour |
date | 2022-02-04T14:14:21+01:00 |
description | Definition of the Observation for the resection margin invasive tumour |
copyright | CC-BY-SA-4.0 |
jurisdictions | ch |
fhirVersion | 4.0.1 |
kind | resource |
abstract | false |
sdTtype | Observation |
derivation | constraint |
base | http://hl7.org/fhir/StructureDefinition/Observation |
Usages |
|
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | Observation |
CH CRL Observation Resection Margin Invasive Tumour ch-crl-obs-1: Observation must have either value[x] or dataAbsentReason |
|
code | Required Pattern: At least the following | |||
coding | 1..* | Coding |
Code defined by a terminology system Fixed Value: (complex) |
|
system | 1..1 | uri |
Identity of the terminology system Fixed Value: http://fhir.ch/ig/ch-crl/CodeSystem/nkrs-variables |
|
code | 1..1 | code |
Symbol in syntax defined by the system Fixed Value: 6.3 |
|
display | 1..1 | string |
Representation defined by the system Fixed Value: Resection margin invasive tumour |
|
subject | 1.. | Reference (CH CRL Patient) | Patient | |
reference | 1.. | |||
effective[x] | 1 .. | Slice: Unordered, Open by type:$this | ||
effectiveDateTime | 1..1 | dateTime | ||
performer | Reference (CH CRL Practitioner | CH CRL Organization Department) | Practitioner if resident physician or Organization Department if hospital | ||
reference | 1.. | |||
valueQuantity | 0..1 | Quantity | The minimal width of the normal tissue between the tumour and the surgical margin of the resected tumour on primary site (microscopic distance between the outermost tumour cells and the cut edge of the specimen). Measurement in millimeter. | |
value | 1.. | |||
unit | 1.. | Required Pattern: millimeter | ||
system | 1.. | Required Pattern: http://unitsofmeasure.org | ||
code | 1.. | Required Pattern: mm | ||
dataAbsentReason | The minimal width of the normal tissue between the tumour and the surgical margin of the resected tumour on primary site is not applicable or unknown | |||
coding | C | 1.. | ch-crl-obs-3: The value for code must be either 'unknown' or 'not-applicable' | |
system | 1.. | Fixed Value: http://terminology.hl7.org/CodeSystem/data-absent-reason | ||
code | 1.. | If not applicable than 'value=not-applicable'. If not stated / not assessed than 'value=unknown'. | ||
display | 1.. | |||
Documentation for this format |
Produced 06 Apr 2023