Source | URL | Version | Realm | Type | Description |
---|---|---|---|---|---|
ObservationDefinition | |||||
hl7.fhir.uv.extensions.r4#1.0.0 | http://hl7.org/fhir/StructureDefinition/replaces|1.0.0 | 5.0.0 | uv | canonical | This indicates a separate conformance resource instance that is superseded by the current instance. |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-dicom-reference|1.0.0 | 4.0.1 | us | (complex) | A reference to a DICOM SOP Instance. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality|1.0.0 | 4.0.1 | us | (complex) | The modality and associated energy used for imaging in Image Guided Radiotherapy (IGRT) Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotheraphy-reason-for-revision-or-adaptation|1.0.0 | 4.0.1 | us | CodeableConcept | The reason a planned or prescribed radiotherapy treatment was revised, superceded, or adapted. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation|1.0.0 | 4.0.1 | us | boolean | This flag is true if the radiotherapy course of treatment involves reirradiation of targets or organs at risk that were already irradiated in previous courses. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-dose-planned-to-volume|1.0.0 | 4.0.1 | us | (complex) | Dose parameters planned for one radiotherapy volume. Profile Paths: ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-dose-prescribed-to-volume|1.0.0 | 4.0.1 | us | (complex) | Dose parameters prescribed for one radiotherapy volume. Profile Paths: ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope|1.0.0 | 4.0.1 | us | CodeableConcept, Quantity | The radiation energy used for radiotherapy. The energy spectrum is characterized
by the maximum energy, the maximum accelaration voltage, or the used isotope. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-delivered|1.0.0 | 4.0.1 | us | unsignedInt | The total number of fractions (treatment divisions) actually delivered for this volume. Profile Paths: Procedure |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-planned|1.0.0 | 4.0.1 | us | positiveInt | The number of planned fractions in this scope.
This extension SHALL only be present if the treatment is structured as countable fractions, for example in a Radiotherapy Planned Phase or in a Radiotherapy Treatment Plan. Profile Paths: ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-prescribed|1.0.0 | 4.0.1 | us | positiveInt | The number of prescribed fractions in this scope.
This extension SHALL only be present if the treatment is structured as countable fractions, for example in a Radiotherapy Phase Prescription. Profile Paths: ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique|1.0.0 | 4.0.1 | us | CodeableConcept | Technique to manage respiratory motion with free-breathing. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose|1.0.0 | 4.0.1 | us | boolean | This flag is true if the dose is determined at a single point.
Point doses are often used to check dose at a specific point in a calculated 3D dose distribution.
Since point doses mostly have a technical role, high-level summaries may decide to exclude them from displays. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose|1.0.0 | 4.0.1 | us | boolean | This flag is true if the dose is the primary plan dose in a radiotherapy treatment plan.
For a single treatment plan, the primary plan dose serves as the main dose value for tracking delivered dose vs. planned dose.
In summaries over multiple treatment plans, the flag indicates that the dose is a primary plan dose in any of the summarized plans. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management|1.0.0 | 4.0.1 | us | CodeableConcept | Method applied to manage respiratory motion. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type|1.0.0 | 4.0.1 | us | CodeableConcept | Radiotherapy Treatment Applicator Type. Profile Paths: Procedure, ServiceRequest |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation|1.0.0 | 4.0.1 | us | boolean | This flag is true if the fractionation was uniform (i.e., treated with same modality and dose per fraction) and false if the fractionation was mixed. Treatment technique may vary in uniform fractionation.
If the fractionation was uniform, then the correspondence between the physical and biologically effective dose can be determined at the course level.
If the fractionation was not uniform, then the correspondence between the physical and biologically effective dose has to be determined per the phase level.
The flag was introduced to support determination of whether fractionation was uniform when viewing the Radiotherapy Course Summary (without first checking the details of each treatment phase).
This is important in registry use cases to efficiently assess whether checking phase level information is needed. Profile Paths: Procedure |
hl7.fhir.us.codex-radiation-therapy#current | http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-volume-extension|1.0.0 | 4.0.1 | us | Reference | Extension providing a reference to a RadiotherapyVolume Profile Paths: Observation |
hl7.fhir.uv.dx-pq#current | http://hl7.org/fhir/uv/dx-pq/StructureDefinition/Extension-qualified-value-text-dxpq|0.1.0 | 5.0.0 | uv | string | |
hl7.fhir.uv.livd#current | http://hl7.org/fhir/uv/livd/StructureDefinition/ext-device|0.3.0 | 4.0.1 | uv | Reference | Add a reference from the ObservationDefinition to the Device. Profile Paths: ObservationDefinition |
hl7.fhir.uv.livd#current | http://hl7.org/fhir/uv/livd/StructureDefinition/ext-vendorReferenceIdentifier|0.3.0 | 4.0.1 | uv | Identifier | Add a vendor reference identifier to ObservationDefinition. Profile Paths: ObservationDefinition |
ObservationDefinition.qualifiedValue | |||||
hl7.fhir.uv.dx-pq#current | http://hl7.org/fhir/uv/dx-pq/StructureDefinition/Extension-qualified-value-display-dxpq|0.1.0 | 5.0.0 | uv | string | |
hl7.fhir.uv.dx-pq#current | http://hl7.org/fhir/uv/dx-pq/StructureDefinition/Extension-qualified-value-text-dxpq|0.1.0 | 5.0.0 | uv | string | |
ObservationDefinition.qualifiedValue.appliesTo.text, ObservationDefinition.title | |||||
hl7.fhir.uv.dx-pq#current | http://hl7.org/fhir/uv/dx-pq/StructureDefinition/Extension-test-comment-dxpq|0.1.0 | 5.0.0 | uv | string |