Cross-Version Extension for DeviceMetric.measurementFrequency in R5

URLhttp://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceMetric.measurementFrequency
Version
Statusactive
Description

Cross-Version Extension for DeviceMetric.measurementFrequency. Valid in versions R2, R3, R4, R4B

This is a valid cross-version extension because it's counted as a new element

Context of Use

This extension may be used in the following contexts:


NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..1ExtensionIndicates how often the metric is taken or recorded
... extension ..0
... value[x] 1..Quantity
... url "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceMetric.measurementFrequency"

doco Documentation for this format

{
  "resourceType" : "StructureDefinition",
  "id" : "xv-r5-dvm.measurementFrequency",
  "url" : "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceMetric.measurementFrequency",
  "name" : "XVerExtensionDeviceMetric.measurementFrequencyR5",
  "title" : "Cross-Version Extension for DeviceMetric.measurementFrequency in R5",
  "status" : "active",
  "experimental" : false,
  "publisher" : "Health Level Seven International (Health Care Devices)",
  "contact" : [{
    "telecom" : [{
      "system" : "url",
      "value" : "http://hl7.org/fhir"
    }]
  },
  {
    "telecom" : [{
      "system" : "url",
      "value" : "http://www.hl7.org/Special/committees/healthcaredevices/index.cfm"
    }]
  }],
  "description" : "Cross-Version Extension for DeviceMetric.measurementFrequency. Valid in versions R2, R3, R4, R4B\r\n\r\nThis is a valid cross-version extension because it's counted as a new element",
  "jurisdiction" : [{
    "coding" : [{
      "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
      "code" : "001"
    }]
  }],
  "fhirVersion" : "5.0.0",
  "kind" : "complex-type",
  "abstract" : false,
  "context" : [{
    "extension" : [{
      "extension" : [{
        "url" : "startFhirVersion",
        "valueCode" : "4.3"
      },
      {
        "url" : "endFhirVersion",
        "valueCode" : "4.3"
      }],
      "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use"
    }],
    "type" : "element",
    "expression" : "DeviceMetric"
  },
  {
    "type" : "extension",
    "expression" : "http://hl7.org/fhir/4.3/StructureDefinition/extension-DeviceMetric"
  },
  {
    "extension" : [{
      "extension" : [{
        "url" : "startFhirVersion",
        "valueCode" : "4.0"
      },
      {
        "url" : "endFhirVersion",
        "valueCode" : "4.0"
      }],
      "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use"
    }],
    "type" : "element",
    "expression" : "DeviceMetric"
  },
  {
    "type" : "extension",
    "expression" : "http://hl7.org/fhir/4.0/StructureDefinition/extension-DeviceMetric"
  },
  {
    "extension" : [{
      "extension" : [{
        "url" : "startFhirVersion",
        "valueCode" : "3.0"
      },
      {
        "url" : "endFhirVersion",
        "valueCode" : "3.0"
      }],
      "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use"
    }],
    "type" : "element",
    "expression" : "DeviceMetric"
  },
  {
    "type" : "extension",
    "expression" : "http://hl7.org/fhir/3.0/StructureDefinition/extension-DeviceMetric"
  },
  {
    "extension" : [{
      "extension" : [{
        "url" : "startFhirVersion",
        "valueCode" : "1.0"
      },
      {
        "url" : "endFhirVersion",
        "valueCode" : "1.0"
      }],
      "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use"
    }],
    "type" : "element",
    "expression" : "DeviceMetric"
  },
  {
    "type" : "extension",
    "expression" : "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceMetric"
  }],
  "type" : "Extension",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension",
  "derivation" : "constraint",
  "differential" : {
    "element" : [{
      "path" : "Extension",
      "short" : "Indicates how often the metric is taken or recorded",
      "definition" : "The frequency at which the metric is taken or recorded. Devices measure metrics at a wide range of frequencies; for example, an ECG might sample measurements in the millisecond range, while an NIBP might trigger only once an hour. Less often, the measurementFrequency may be based on a unit other than time, such as distance (e.g. for a measuring wheel). The update period may be different than the measurement frequency, if the device does not update the published observed value with the same frequency as it was measured.",
      "min" : 0,
      "max" : "1",
      "isModifier" : false
    },
    {
      "path" : "Extension.extension",
      "max" : "0"
    },
    {
      "path" : "Extension.value[x]",
      "min" : 1,
      "type" : [{
        "code" : "Quantity"
      }]
    },
    {
      "path" : "Extension.url",