URL | http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.type |
Version | |
Status | active |
Description | Cross-Version Extension for Device.type. Valid in versions R2, R3, R4, R4B This is a valid cross-version extension because the cardinality changed |
Context of Use
This extension may be used in the following contexts:
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Extension | The kind or type of device | |
![]() ![]() ![]() | ..0 | |||
![]() ![]() ![]() | 1.. | CodeableConcept | ||
![]() ![]() ![]() | "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.type" | |||
![]() |
{ "resourceType" : "StructureDefinition", "id" : "xv-r5-dev.type", "url" : "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.type", "name" : "XVerExtensionDevice.typeR5", "title" : "Cross-Version Extension for Device.type in R5", "status" : "active", "experimental" : false, "publisher" : "Health Level Seven International (Orders and Observations)", "contact" : [{ "telecom" : [{ "system" : "url", "value" : "http://hl7.org/fhir" }] }, { "telecom" : [{ "system" : "url", "value" : "http://www.hl7.org/Special/committees/orders/index.cfm" }] }], "description" : "Cross-Version Extension for Device.type. Valid in versions R2, R3, R4, R4B\r\n\r\nThis is a valid cross-version extension because the cardinality changed", "jurisdiction" : [{ "coding" : [{ "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm", "code" : "001" }] }], "fhirVersion" : "5.0.0", "kind" : "complex-type", "abstract" : false, "context" : [{ "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "4.3" }, { "url" : "endFhirVersion", "valueCode" : "4.3" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Device" }, { "type" : "extension", "expression" : "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device" }, { "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "4.0" }, { "url" : "endFhirVersion", "valueCode" : "4.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Device" }, { "type" : "extension", "expression" : "http://hl7.org/fhir/4.0/StructureDefinition/extension-Device" }, { "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "3.0" }, { "url" : "endFhirVersion", "valueCode" : "3.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Device" }, { "type" : "extension", "expression" : "http://hl7.org/fhir/3.0/StructureDefinition/extension-Device" }, { "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "1.0" }, { "url" : "endFhirVersion", "valueCode" : "1.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Device" }, { "type" : "extension", "expression" : "http://hl7.org/fhir/1.0/StructureDefinition/extension-Device" }], "type" : "Extension", "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension", "derivation" : "constraint", "differential" : { "element" : [{ "path" : "Extension", "short" : "The kind or type of device", "definition" : "The kind or type of device. A device instance may have more than one type - in which case those are the types that apply to the specific instance of the device.", "comment" : "Multiple device types are use when a device is categorized in more than one context – for example, hybrid devices in which the device is both of type gateway and sensor.", "min" : 0, "max" : "*", "isModifier" : false }, { "path" : "Extension.extension", "max" : "0" }, { "path" : "Extension.value[x]", "min" : 1, "type" : [{ "code" : "CodeableConcept" }] }, { "path" : "Extension.url", "fixedUri" : "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.type" }] } }