URL | http://hl7.org/fhir/4.0/StructureDefinition/extension-EvidenceVariable.identifier |
Version | |
Status | active |
Description | Cross-Version Extension for EvidenceVariable.identifier. Valid in versions R2, R3 This is a valid cross-version extension because it's counted as a new element |
Context of Use
This extension may be used in the following contexts:
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Extension | Additional identifier for the evidence variable | |
![]() ![]() ![]() | ..0 | |||
![]() ![]() ![]() | 1.. | Identifier | ||
![]() ![]() ![]() | "http://hl7.org/fhir/4.0/StructureDefinition/extension-EvidenceVariable.identifier" | |||
![]() |
{ "resourceType" : "StructureDefinition", "id" : "xv-r4-evv.identifier", "url" : "http://hl7.org/fhir/4.0/StructureDefinition/extension-EvidenceVariable.identifier", "name" : "XVerExtensionEvidenceVariable.identifierR4", "title" : "Cross-Version Extension for EvidenceVariable.identifier in R4", "status" : "active", "experimental" : false, "publisher" : "Health Level Seven International (Clinical Decision Support)", "contact" : [{ "telecom" : [{ "system" : "url", "value" : "http://hl7.org/fhir" }] }, { "telecom" : [{ "system" : "url", "value" : "http://www.hl7.org/Special/committees/dss/index.cfm" }] }], "description" : "Cross-Version Extension for EvidenceVariable.identifier. Valid in versions R2, R3\r\n\r\nThis is a valid cross-version extension because it's counted as a new element", "jurisdiction" : [{ "coding" : [{ "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm", "code" : "001" }] }], "fhirVersion" : "5.0.0", "kind" : "complex-type", "abstract" : false, "context" : [{ "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "3.0" }, { "url" : "endFhirVersion", "valueCode" : "3.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Basic" }, { "extension" : [{ "extension" : [{ "url" : "startFhirVersion", "valueCode" : "1.0" }, { "url" : "endFhirVersion", "valueCode" : "1.0" }], "url" : "http://hl7.org/fhir/StructureDefinition/version-specific-use" }], "type" : "element", "expression" : "Basic" }], "type" : "Extension", "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension", "derivation" : "constraint", "differential" : { "element" : [{ "path" : "Extension", "short" : "Additional identifier for the evidence variable", "definition" : "A formal identifier that is used to identify this evidence variable when it is represented in other formats, or referenced in a specification, model, design or an instance.", "comment" : "Typically, this is used for identifiers that can go in an HL7 V3 II (instance identifier) data type, and can then identify this evidence variable outside of FHIR, where it is not possible to use the logical URI.", "requirements" : "Allows externally provided and/or usable business identifiers to be easily associated with the module.", "min" : 0, "max" : "*", "isModifier" : false, "mapping" : [{ "identity" : "workflow", "map" : "Definition.identifier" }, { "identity" : "w5", "map" : "FiveWs.identifier" }, { "identity" : "objimpl", "map" : "no-gen-base" }] }, { "path" : "Extension.extension", "max" : "0" }, { "path" : "Extension.value[x]", "min" : 1, "type" : [{ "code" : "Identifier" }] }, { "path" : "Extension.url", "fixedUri" : "http://hl7.org/fhir/4.0/StructureDefinition/extension-EvidenceVariable.identifier" }] } }